Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L1 | Accepted-AOC LOWEST TENDERER | |
| 2 | L2₹42.0 L+₹10.5 L (33.3%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-AOC GREATER THAN L1 | |
| 3 | L3₹47.6 L+₹16.0 L (50.8%)Rejected-AOC FLAT NO 404 A WING HILL SIDE RESIDENCY BEHIND KIRTI POLICE SOCIETY KATRAP BADLAPUR EAST DIST THANE MAHARASHTRA 451503 | 451503 | L3 | Rejected-AOC GREATER THAN L1 | |
| 4 | L4₹48.1 L+₹16.6 L (52.7%)Rejected-AOC 503 GIRIRAJ HEIGHT VAITY WADI L B S MARG NEAR HARINIWAS CIRCLE THANE 400 602 | THANE | MAHARASHTRA | 400602 | L4 | Rejected-AOC GREATER THAN L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical DOCUMENTS NOT FOUND CORRECT |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
1 Oct 2024, 6:00 pmClosed
Gaurav Tiwari, IDSE
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
REP MAINT TO GEYSERS AND ALL TYPE OF FANS AND REP MAINT TO INTERNAL ELECTRICAL WIRING AND ACCESSORIES INLCUDINDG EARTHING AND CONNECTED WORKS OTM AREA AT INS SHIVAJI LONAVLA
2024_MES_671071_1
GE/LONAVLA/8263/E8
Open Tender
Civil Works
Item Rate
210 days
GE (I) (NAVY) LONAVLA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹64,000
Yes
12 Dec 2024
3 Sept 2024
3 Oct 2024
3 Sept 2024
1 Oct 2024
18 Sept 2024
3 Sept 2024 - 17 Sept 2024
Amount
Taking down/maintenance for parts of geysers of any capacity /make after disconnecting the wire from existing power point and refixing the same after replacement of heating element, thermostate, geyser assembly, PVC pipe & anchor bolts (if required) complete including providing T-3 core copper conductor wire from power point to geyser input upto 1 mtr length complete all as directed by Engr -in- charge, Notes for Sr. item no. 1& 24 :- (i) Work shall be carried out at the site on routine basis , (ii) Spares for Geyser & ceiling fan (heating element, thermostate, ARV, NRV, PVC pipe, gasket,Bearing,blade,bush,down rod, clamp and anchor bolts will be measured and paid separately). (iii) Any unattended complaint of geyser not done with in 2 days, contractor shall be penalty Rs 200 on each complaint per day is applicable.Also contractor should convey the reason for not repair of Geyser/fan to concerned JE/Eng-in-charge.
Taking down and fixing on the site of old & unserviciable geyser after replacement of to verticle/horizontle tank of any Make, capacity 25 to 50 ltr all as specifide and directed .
S& F in replacement of cable PVC insulated 3 core 2.5 Sqmm with stranded copper conductor 1100Volts grade from socket /switch to geyser.
M&L for repair of geyser inner tank of 25/50 ltrs capacity by gas welding /brazing for water tightness and testing complete
Supply and fix in replacement of 20A SP/SPN plug and socket enclosure in sheet steel enclosures without SP/SPN MCB complete all as specified and directed.
Supply only in replacement of Geyser water storage tank vertical/horizental type capacity 25 ltr make of metal copper/stainless steel as specified and directed
Supply only in replacement of of Geyser water storage tank verticle/horizental type capacity 50 ltr make of metal copper/stainless steel as specified and directed
Taking down and refixing on the site after replacement of geyser (new generation) of any make and capacity including taking down old component and replace with new unservicable component like heating element, thermostate, neon lamps, NRV, ARV, gas welding /brazing and any other important part as required on site, to make it serviceable, complete all as specified and directed by Engr-in-Charge.
Taking down and refixing on the site after replacement of solar geyser of any make and capacity including providing heating element, thermostate, neon lamps, NRV, ARV, gas welding /brazing and any other important part of solar plate as required on site, to make it serviceable, complete all as specified and directed by Engr-in-Charge. Note for item No 08 and 09 all spare parts will be measured and paid seperately under relivent supply only item.
Supply only in replacement of Glass wool PF any colour complete all as directed by Engineer-in-Charge
Supply only in replacement of heating element triangle type 1500 watt , complete all as specified and directed by Engineer –in-Charge.
Supply only in replacement of heating element cup type1500 watt, complete all as specified and directed by Engineer –in-Charge
Supply only in replacement of heating element thread type 1500 watt , complete all as specified and directed by Engineer –in-Charge
Supply only in replacement of heating element triangle type 2000 watt , complete all as specified and directed by Engineer –in-Charge
Supply only in replacement of heating element cup type 2000 watt, complete all as specified and directed by Engineer –in-Charge
Supply only in replacement of heating element thread type 2000 watt, complete all as specified and directed by Engineer –in-Charge
Supply only in replacement of themostate for geyser, complete all as specified and directed by Engineer –in-Charge
Supply only in replacement of neon lamp for geyser yellow /red/green, complete all as specified and as directed by Engineer –in-Charge
Supply only in replacement of air realese valve for geyser as specified and as directed
Supply only in replacement of Non returned valve 15mm for geyser all specified and as directed
Supply and fixing in replacement of flexi PVC connection armoured type both side brass union type nuts 45/60/90cm length complete all as specified and directed.
Supply only in replacement of anchor bolts 75mm long made out of stain less steel complete all as specified and directed
Supply only in replacement of gasket rubber ring of Heater plate of any size geysers.
Supply and fix in replacement of new geyser assembly for any make/model/capacity of geysers including all necessary replacement of required to make it serviceable. complete all as specified and directed by Engr-in-Charge.
Taking down and dismantling of ceiling fan, segregation of unserviceable parts, cutting and removing out copper winding, cleaning the armature, rewinding of fan armature with appropriate gauge of super enamelled copper wire with necessary insulating materials such as vertex paper, cotton tape, PVC insulation tape, Rotter soft etc varnishing with approved grade of insulation varnish and heating up, re-assembling the fan complete with replacement of unserviceable spares parts, (spareparts will be measured & paid separately) including necessary lathe work for fixing of bush/bearing greasing the same with approved grade of grease, making all electrical connection and including supply and fixing the following items ( Split pin - 02 Nos, Connection block - 1 No and Insulation rubber bush. - 01 No) and including necessary transportion to workshop, for following sweeps of ceiling fan . (a) 1200MM
Fixing or hanging only ceiling fan after rewinding fan under item No. 25 above and , connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) all as specified and directed
Taking out defective /burnt winding of air ventilator/exhaust fan of various make of size 225 mm sweep working on 230 to 380 volts single phase /AC supply and Rewinding with supper enamiled new copper wire of apropriate Gauge including warnishing good quality varnish heating and re assembling the fan /testing /transpotation /placment/of connector flexible copper wire size 23/0.0040, 3 core up to one metre/reqd at site complete all as specifiede and directed.
All as Item No 28 above but for exhaust fan rewinding of size 250mm sweep
All as Item No 28 above but for exhaust fan rewinding of size 380mm sweep
All as Item No 28 above but for exhaust fan rewinding of size 450mm sweep
Fixing only exhaust fan after winding fan any height under item No. 28 to 31 above and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) all as specified and directed
Supply and fixing in replacement of exhaust fan (Plastic body) blade of size 250 to 300mm sweep.
Supply and fixing in replacement of (Plastic body) exhaust fan motor suitable for 250 to 300mm sweep exhaust fan.
Supply and fixing in replacement of exhaust fan (Plastic body) complete plastic body including louvers suitable for 250 to 300mm sweep exhaust fan.
Overhauling of ceiling fan of any make and sweep after opening and cleaning rotor bearing and stator properly and oiling/greasing of bearing/ bushes, reassmbling the same, fixing and connecting on its existing position and testing on completion all as specified and as directed including taking down.(Note- (i) Overhauling of ceiling fans will be carried out at AGE E/M Yard only. (ii) The spares required shall be measured and paid separately in the relevant items).
Taking down/Overhauling exhaust/wall mounted fan of any type and size after disconnecting the conection from exiting ceiling to connector and transpotation to work shop /cleanig externally dismantlling and examining the roter /stator /bearing/bushing etc for serviciablity /replacement oiling/replacing/defective part subsequntly oiling /greasing/assembling/ testing of proper functioning cheking for safety/ security and proper locking transporting back to building /site to workshop/hanging /fixing/and connecting /the electrical conection testing of noise free smooth runing etc.all as directed
Taking down of ceiling fan/exhaust fan of any size /sweep after disconecting the wire from existing ceilling rose and refixing the same after cleaning dust ,oiling, greasing & hanging clamps (if required) complete including providing flexible twin core copper conductor stranded cord from ceilling rose to connection of fan upto 1 mtr length complete all as directed by Engr -in- charge,Notes :- Works will be carried out at the site on routine basis.
Taking down old unservisable rusted ceiling fan blades and providing new ceilling fan blades with fixing new screw as appropriate shape /size suitable for ceilling fan of any make and 1200mm sweep size complete all as specified and directed.
All as per item No 39 above but size 1400 mm.
Taking down old unservisable rusted exhaust fan blades and providing new exhaust fan blades with fixing new screw as apporpriate shape /size suitable for exhaust fan of any make and size of sweep complete all as specified and directed.
Supply and fixing of stator and rotor assembly including body cell of ceiling fan for size 1200 mm sweep complete including carbon brush, wire, etc all as specified and directed by Engr in Charge.
Painting of ceiling fan/ 1200/1400 mm sweep/exhaust fan 225 to 450 mm sweep complete including fan blade down rod with synthetic enamelled paint of white tint including cleaning and removing dust and dirt and making smooth surface for painting including writing MES No complete all as specified.
Taking out worn out gun metal bush and supply and fix new gun mettal bush for various make of ceilling fan of size 1200 to 1400 mm sweep complete all as specifide and as directed (Make - MSP or eqvt as approved by GE).
Supply and fix bearing for ceiling fan (Bearing No.6201 Z Type).
Supply and fix bearing for ceiling fan (Bearing No.6202 Z Type).
Supply and fix bearing for ceiling fan (Bearing No.6203 Z Type).
Supply and fix bearing for ceiling fan (Bearing No.6204 Z Type).
Taking out defective capacitor and supply and fix new capocitor of 2.5 MFD 230 volts with conector(capacitor holder with nut) including PVC clamps nuts , as approved make for various make of ceilling fan complete all as specified as directed.
Taking out defective capacitor and supply and fix new capocitor of 4 MFDas approved make for various make of exhaust fan complete all as specified as directed.
Taking out defective capacitor and supply and fix new capocitor of 6 MFDas approved make for various make of exhaust fan complete all as specified as directed.
Supply only Split pin.
Supply, fixing in replacement and connecting up flexible copper cable twin core of 0.75 Sqmm.
Taking out rusted /defective down rod and supply and fix new down Rod of medium grade GI tubing 15mm bore having hole and threading at ends as per site requirement complete specified all as directed.
Removing broken /cracked Canopy of any make and type and supply and fix new canopy of existing make and size all as directed.
S&F in replacement of Rubber real for fans clamp complete all as per sample
Receiving complaints from JE incharge lodged by the user/occupants of electrification nature, rectification of the fault as per the compaint lodged by the user onward KWH meter in respect of main distribution board having switch board, fused, MCB distribution board in sheet metal enclosure, point wiring fixture for light/fan /bell /light or power sockets, metal clad plug socket complete repair to the extend by removing connections from the system, removing faults in (surface /concealed) wiring/ circuits, sunken boxes, Junction boxes, main switches, MCBs/DBs any type of utility light fittings, lamp holders, AC ceiling fan/exhaust fans and other connected fixtures of internal electrification including providing stores such as wires of appropriate size and conductor matching to existing one upto the height of 2 mtr, insulation tape, screws, nuts as per the site requirement to rectify the fault with regard to complaint lodged and refixing of fitting and fixture to their original position as dismentled complete all as directed at site to the entire satisfaction of Engineer -in- Charge. Note : (i) Any complaint which is left out/unattendent 2 days by the electrician by any reasons the same to be communicated to the JE incharge /AGE E/M with reason. (ii) New material/stores provided for completing the job shall be measured and paid for separetely under relevent items of sch 'A'. (iii) Contractor shall provide the all type of T & P to each electrician for attending the internal electric complaints. (iv) Contractor shall provide the complaint register and complaint slip serially numbered in duplicate as per sample. If complaint required online the contractor should provide A4 size paper and printer for printng complaints.The rate of such items included in this items. (v) Any unattended complaints not done in specified time limit. The contractor shall penalty Rs. 200/- on each complaints per day.
Supply only in replacement switch piano type 5 Amps one way AC 230 Volts.
Supply only in replacement switch piano type 5 Amps two way AC 230 Volts.
Supply only in replacement of bell push 5 Amps, AC 230 Volts.
Supply only in replacement switch/socket combination outlet 3 pin 5 Amps flush type (Multi purpose) piano type AC 230 Volts.
Supply only in replacement switch/socket combination outlet 2 in 1, 3 pin 5 Amps and 15 Amp flush type (Multi purpose) piano type AC 230 Volts.
Supply only in replacement of electronic dimmers, 450W, 250V flush type on the exiting phenolic laminated sheet etc. as reqd.
Supply only in replacement of stepped type electronic fan regulator, flush type on the exiting phenolic laminated sheet etc. as reqd.
Supply only in replacement switch modular type 6 Amps one way AC 230 Volts.
Supply only in replacement switch modular type 16 Amps one way AC 230 Volts.
Supply only in replacement modular type bell push 6 Amps, AC 230 Volts.
Supply only in replacement modular type socket 6 Amps 2/3 pin combined, AC 230 Volts.
Supply only in replacement modular type socket 6/16 Amps 2/3 pin combined, AC 230 Volts.
Supply only in replacement modular type fan regulator, AC 230 Volts.
Supply only in replacement modular white cover plate with frame, 2 module.
Supply only in replacement modular white cover plate with frame, 4 module.
Supply only in replacement modular white cover plate with frame, 8 module. Note:- for S No 65 to 73 contrator should provide modular electric assessories as per existing make/ model for replacement and as & when required.
Supply only in replacement of ceiling rose 65x50mm two to three terminal AC 230 volts complete all as specified.
Supply only buzzer,AC, 230 volts, single phase.
Supply only bell, ding dong, AC, 230 volts, single phase.
Supply only bell multi music type AC, 230 volts, single phase.
Supply only in replacement lamp holder insulated body with back plate batten/angle type for batten fittings.
Supply only in replacement sheet metal enclosures with plug socket single pole and neutral with two pin and earth plug and with one MCB of 20 Amps (SP) complete all as specified. Note:- Rate of MCB and plug top are included in the quoted rates.
Supply only in replacement of 30 Watt inverter LED street light fitting luminaire, energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08, including coneecting up with 2/3 core flexible coppper conductor cable, compete all as specified and directed by Engr-in-Charge. Make -HLSLD-ML04-30-CWL-INV-RTC-R Halonix/Shakti/Philips/ Havells
Supply only in replacement cable flexible PVC insulated twin core with copper conductor of size 23/0.0076
Supply only in replacement cable flexible PVC insulated twin core with copper conductor of size 40/0.0076
Supply only in replacement plug top 3 pin 5 amps AC 230 volts.
Supply only in replacement plug top 3 pin 15 Amps AC 230 volts.
Supply only PVC connector block two ways AC 230 volts suitable for fan/tube light fittings etc.
Supply only bakelite sheet not less than 3mm thick for mounting of switch sockets, fan regulators, etc. size 100x100mm or PVC rectangular Box of 100 mm x 100mm and 50 mm deep complete with screws and washers, etc. all as specified and directed by Engr-in-Charge.
Supply only bakelite sheet not less than 3mm thick for mounting of switch sockets, fan regulators, etc. size 175x100mm or PVC rectangular Box of 175 mm x 100mm and 50 mm deep complete with screws and washers, etc. all as specified and directed by Engr-in-Charge.
Supply only bakelite sheet not less than 3mm thick for mounting of switch sockets, fan regulators, etc. size 250x200mm or PVC rectangular Box of 250 mm x 200mm and 50 mm deep complete with screws and washers, etc. all as specified and directed by Engr-in-Charge.
Supply only bakelite sheet not less than 3mm thick for mounting of switch sockets, fan regulators, etc. size 200x150mm or PVC rectangular Box of 200 mm x 150mm and 50 mm deep complete with screws and washers, etc. all as specified and directed by Engr-in-Charge.
Supply only in replacement MCB SP, 6 to 32 Amps 10 KA single pole AC 230 volts complete all as specified
Supply only in replacement MCB SPN 6 to 40 Amps 10 KA AC 230 volts complete all as specified
Supply and fixing brass/copper thimble (lugs) bottle type suitable for MCBs with sub circuit wires complete all as specified
Supply only in replacement of rigid non metalic PVC conduit conduct including junction boxes terminal, tees bends, elbows reducers, bell mouth tube ends and fixing accessories such as complete, lock nuts, saddles pipe hook etc of size 20mm dia. complete all as specified and directed by Engineer in charge.
Supply only in replacement twin sub main cable with 2 x 4 Sqmm multistrand PVC insulated unsheathed copper conductor PVC cable including contineous earth wire 1 x 4 Sqmm copper conductor insulated unsheathed complete all as specified and directed by Engineer in charge as following:- (a) In PVC conduit(20mm)
(b) In PVC casing caping(25mm)
All as per srl item No 94 here in before but 2 x 6 sqmm copper cable as a sub main and 1 x 6 sqmm cable as a earth lead complete all as specified and directed by Engineer in charge. (a) In PVC conduit(20mm)
(b) In PVC casing caping(25mm)
Point wiring with 1.5 Sqmm (nominal area) copper conductor cable (Multi strand) PVC insulated and unsheathed in and incl PVC casing caping of adequate size with 3mm thick plastic laminated sheet cover of adequate size for one light or one fan /05 amp socket /bell controlled by one switch incl 1.5 Sqmm (nominal area) copper conductor cable (multi strand) PVC insulated and unsheathed with colour code earth wire to common earth dolly complete all as specified.
All as per srl item No 98 here in before but with 2.5 sqmm copper conductor cable (multistrand) complete all as specified and directed by Engineer in charge.
Supply only in replacement 20 Watt LED Tube Light (4 feet) Ultra bright, (single side connection) with very high efficacy & THD <15% best suited for installation in existing tubelight luminaire with G13 lamp holders to give glare free light. Make:- PHOTONNULTRAE2.01213T8SSTL20WLED865SPC Havells OR Equivalent to Halonix/Philips
Supply only in replacement of LED Batten 1x 20W, 220V, AC, with driver, holder excluding LED tube light mounted on square box of suitable size connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make:- REGALBATTENT8UPTO1X22WSSBSWHNW Havells OR Equivalent to Halonix/Philips
Supply only in replacement of sheet metal enclosure (Factory made) double door shutter type for distribution board (when MCBs are to be used) single pole and neutral 240 volts 8 way with 200 Amps rated busbar all as specified
All as per srl item No 102 here in before but 4 way SPN with 200 amps rated bus bar all as specified
All as per srl item No 102 here in before but 4 way TPN 415 volts all as specified
Supply only in replacement MCB TPN, 415 Volts, 63 Amps all as specified.
Supply only in replacement PVC casing caping and fixing accessories such as complete, lock nuts, saddles hook etc of adequate size complete all as specified and directed by Engineer in charge.
Supply only in replacement of 18 Watt LED 6500 K (PRIDE PLUS) inverter LED batten with square profile and polycarbonate channel. Lithium Ion battery with charging time 8hours-10 hours and back up time upto 4 hours mounted on square box of suitable size connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make:-SZSLBMX018-iBB Shakti/Philips/Havells
Supply and fixing in replacement spring loaded rotary type bipin holder suitable for LED tube light fittings.
Supply only in replacement invertor LED lights fitting 1x 10W (2 Ft), 220V, AC, LED batten with square profile and polycarbonate channel. Lithium Ion battery with charging time 8-10 hours and back up time upto 4 hours., mounted on square box of suitable size including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make:-SZSLBMX009-iBB Shakti/ Philips/Halonix/Havells
Supply only LED luminaire invertor 600 x 600mm, 36 watt, 220 volts AC recessed/ surface type fittings, epoxy powder coated CRCA sheet housing with electronic driver and tri-colour CCT with remote control, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.(Make:-HLFPR22-05-36-CW-R-RF-3CCT HALONIX/HAVELLS/BAJAJ/SHAKTI
Supply only invertor LED lamp 9 watt capacity complete all as specified and directed by Engineer-in-Charge..Make:- SZBLB22009 - iBB Shakti/havells/Halonix
Supply only invertor LED lamp 12 watt capacity complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of 20 Watt LED streetlight fitting luminaire, energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08, including coneecting up with 2/3 core flexible coppper conductor cable, compete all as specified and directed by Engr-in-Charge. Make:-SZPSLMM020 Shakti/Philips/ Halonix/Havells
Supply only in replacement of LED round shape 15 watt 220 volts AC recessed type with high efficacy PMMA diffuser soft glare free light complete with drivers, clamps and suitable size as per ground requirement complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.Make:-SZRDRMX015 Shakti/Philips/ Halonix/Havells
Supply only in replacement of invertor LED bulkhead 10 watt 220 volts AC with high efficacy PMMA diffuser soft glare free light complete with drivers, clamps complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make : CP No HLBH-15-10-CW-INV Halonix/ Philips/ Crompton/ Bajaj
Shree Ayyappa Engineering (BID ID -3111137)
M/S SOMANATH ENTERPRISES (BID ID -3124301)
United Engineers and Contractors (BID ID -3123543)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .