Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC 292 GROUND FLOOR D BLOCK SAI DHAM RAJ CITY LONI BANTHLA GHAZIABAD GHAZIABAD UTTAR PRADESH 201102 | GHAZIABAD | UTTAR PRADESH | 201102 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹43.2 L+₹5.9 L (15.7%)Rejected-Finance 1A BASEMENT 30 31 RAJA HOUSE NEHERU PLACE NEW DELHI | NEW DELHI | NEW DELHI | DELHI | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹43.9 L+₹6.6 L (17.8%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹47.6 L+₹10.3 L (27.7%)Rejected-Finance MANEGAON DIWAN BADA KHAMARIA JABALPUR M P PIN 482005 | JABALPUR | MADHYA PRADESH | 482005 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹47.8 L+₹10.5 L (28.1%)Rejected-Finance PLOT NO 81 SHANTAJI COLONY JANKI NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
8 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JABALPUR
HQ CWE JABALPUR OPPOSITE SUPPLY DEPOT SADAR 482001
PROVISION OF 02 X 200 KVA GEN SET FOR 506 ABW JABALPUR UNDER GE(EAST) JABALPUR
2023_MES_580295_1
82627/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JABALPUR
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE EAST JABALPUR
₹88,000
Yes
13 May 2023
10 Feb 2023
10 Mar 2023
10 Feb 2023
8 Mar 2023
24 Feb 2023
10 Feb 2023 - 23 Feb 2023
Amount
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth and getting out in soft/ loose soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M & L for sand cuhioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified and as directed. (Note :- Measurement shall be done after puning down of sand.)
Supplying and laying unreinforced precast cement concrete cable covers, Class LV, Type - 1 Flat, size 250mm x 150mm x 40 mm in trenches for cable protection, embossed with "LT 1100 Volts Electric" on the top surface complete all as specified and as directed .
M & L for PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate as in coping of pole including form work & finishing the surfaces even & smooth without using extra cement complete all as specified and directed.
S & F for 80 mm dia GI Pipe light grade for cable protection passing under road/floor or for fixing to poles complete all as specified and directed.
Supply, laying and testing XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor 120 Sqmm 3.5 core complete all as specified and as directed.
Supply, installation, commissioning and testing silent Diesel Engine driven generating set of capacity 200 KVA, 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator mountd on a common MS Chanel base plate frame complete with relay panel and switch gears for automatic starting on main failure, control panel as per IS-13364, CPRI approved specifications complete with foundation , battery with leads control panel with necessary meters and integral acoustic enclosure as recommended by Cental Pollution Control Board complete in all respect with and including accessoeries and components as specified below :-
(a) Diesel Driven Engine :- Fully automatic Electronic Engine, 6 cylinder, Inline, 4 stroke cycle, water cooled diesel engine suitable to develop matching BHP at 1500 RPM as per latest ISS/BSS, capable to take 10% over load for 1 hr after 12 hr of operation and will be suitable for tropical condition complete with and including following accessories ( Make : Kirloskar/Cummins/Ashoka Leyland/Greaves Ltd) (i) Heavy fly wheel and fly wheel housing complete with starting gear ring and to suit flexible coupling duly covered with mud guard. (ii) Dry type, Replaceable paper element air cleaner with restriction indicator (iii) Lubriating oil filter, fuel filter, fuel pre-filter. (iv) Anti vibration pads-quantity and type as recommended by Maufacturer. (v) Fuel injecting system with injection pump nozzles, governer (A1 class electronic governing) of suitable capacity. (vi) Electric start equipment. (vii) Battery rack made out of MS angle iron 40mm x 40mm x 5 mm & 150mm height. (viii) Dual fuel filter system: Pre-filter including water separator and Water In Fuel (WIF) sensor and main filter (ix) Standard integral set-mounted radiator system, designed and tested for 50°C ambient temperature (x) Full flow spin on lube oil filter, Plate type lube oil cooler, First fill of lube oil and coolant
(x) Lead acid storage maintenance free battery 12 volts of rating with suitable AH with charging alternator, Ammeter, as recommended by Manufacturer (Make : Exide/ Cummins), alongwith copper battery lead and connector. (xi) Standard safety device. Daily service fuel tank of capacity (as per Manufacturer design) with mechanical level indicator, detachable, strainer, drain cook, fuel outlet, air vent and locking arrangement etc, including fuel pipe connections. (xii) Exhaust silencer (Hospital Grade silencer) with exhaust piping of suitable size brought outside on top, of size 76.5mm dia and complete length of silencer and exhaust piping continuously wrapped with 12 mm dia asbestos rope and suitable anti-vibration arrangement around pipe passing through wall. (xiii) LCD display type control panel as per Maufacturer's instructions indicating KWH, KVA, PF, Volts, Amps, Hz, RPM, Hour of run, Oil pressure,Oil temperature, Coolant temperature, Fuel level, battery charging ammeter, battery charging lamp and indicator lamp (RYB), panel duly pre wired and displaying protection and safeties as under ;- (aa) Safety :- Auto shut down, visual & audio alarm for low lub oil pressue, low fuel level, canopy temperature. Also DG set with PC1.1 Controller.
(b) Alternator :- 200 KVA brushless type at 0.8 power factor, self regulated, self excited, screen protected, 3 phase with neutral 415 volts 50 Hz , 1500 RPM, 4 wire alternator with insulation class 'H', screen protected drip proof free from commutation problem as per IS : 13364/IS:2613/IS-4722 complete with automatic voltage regulator, having voltage regulation +/- 1% of set volts from No load to full load, SPDP enclosure including making cable connections and alternator control panel as supplied by manufacturer .( Make : Kirloskar/Cummins/Ashoka Leyland/Greaves Ltd) (c) PCC foundation complete as per Maufacturer's design including anti-vibration pads, necessary excavation & earth work in soft /loose soil , sand cushioning, grouting foundation etc. (d) Manufacturer's maintenance and operation manual of DG set- 02 Nos to be supplied. (e) Acoustic enclosure of suitable size to accommodate DG set 200 KVA, modular construction, fabricated out of 3 mm thick, cold annealed CRCA sheet duly epoxy painted, doors to be porvided with high quality EDPN gasket, duly epoxy painted. The canopy to be equipped with heavy duty fans of reputed Manufacturer for air circulation and cooling the canopy. Rock wool of requisite density to be used for insulation. Enclosure to be provided with one light point controlled with one switch for internal lighting. Noise level at one metre to be 75 decibels @ one mtr in line as per CPCB norms.
M & L for earthing complete with galvanized steel earth plate electrode 60cmx60 cmx 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level connecting to and including GI steel strip of size 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 40 mm dia medium grade pipe for protection of GI strip to the extent of 7.5 mtrs asearthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical plate ZNo 3 of SSR par - I (2009) including PCC foundation/chamber in mix 1:2:4 type B1 with angle iron frame CI frame, CI cover with provision of locking arrangement and 20 mm dia medium grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal ( for STP, DG Set body and Panels). Note :- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed to be included in unit rate quoted by the contractor.
MONA GENERATOR SEVICES PVT. LTD.
BHARADWAJ BROTHERS
M/S BHATIA CONSTRUCTIONS
shri krishna traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .