Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-AOC 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L1 | Accepted-AOC Being Lowest bidder | |
| 2 | L2₹17.1 L+₹19,944.30 (1.18%)Rejected-Finance ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹18.4 L+₹1.5 L (8.61%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹37,000
Closing Date
14 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (South) Patiala
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender document
2020_MES_396367_1
GE(S)/PAT-46/NS/2020-21
Open Tender
Civil Works
Item Rate
180 days
Mil Stn Nabha And Mil Stn Sangrur.
Refer tender document
6 documents required · 6 mandatory
₹500
Yes
GE (South) Patiala
₹37,000
Yes
30 Dec 2020
19 Nov 2020
16 Dec 2020
19 Nov 2020
14 Dec 2020
26 Nov 2020
19 Nov 2020 - 25 Nov 2020
60 days
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for fdn, n.exc 10 sq m on plan and n.exc 1.5m in depth and getting out in soft/loose soil, complete all as specified and directed.
M&L cement concrete in foundation type B 2, 1:2:4 ( 40 mm graded stone aggregate) as in filling and mass concrete, complete all as specified and directed.
S & F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed to self tapping screws, complete all as specified and directed.
M&L for hollow sections as in main and cross beams, hip and jack rafters purlins, where connected to common rafters and running rails and guides for slinding doors, fixed with angle cleats or other connecting plates to Fe-290 (Gde E-165), complete all as specified and directed.
S&F mild steel plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections complete all as specified and directed.
Demolition of brick work including all quoins arches pillars etc built in cement mortar, complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone)as in fdn filling mass concrete complete all as specified and directed.
M&L Brick work with sub class B brick straight or curved on plan exc 6.00 m mean radious built in CM 1:6 complete all as specified and directed.
Material & labour for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4, complete all as specified and directed.
M & L 25mm thick PCC 1:2:4 B0 (12.5mm graded crushed stone aggregate ) as in Damp proof course to horizontal or vertical surfaces including necessary form work complete all as specified and directed.
M&L for RCC (nominal mix) type B1 (1:1.5:3 ) 20mm gradede stone aggreagate as in beams,contilever, bressummers, lintel over1.5mtr span, complete all as specified and directed.
M&L for RCC (nominal mix) type B1 (1:1.5:3 ) 20mm gradede stone aggreagate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.
Form work to soffits of suspended slabs such as roof slabs, floorslabs, landings and similar work;not exceeding 200mm thick(Horizontal or sloping), complete all as specified and directed.
M & L formwork to sides and soffits of floor or roof beams,beam haunchings, girders, bressumers, lintels, cantilever, shelves including supports, overhangs, etc also splys between floors and beams etc compete all as specified and directed.
Form work to sides of slab not exc 20cm wide for rough finish surface complete all as specified.
M&L for TMT steel bars 10 mm dia and over, cut tro length, bent to shape required, including cranking, bending spirally or hooping for coloum hooking end stand binding with miuld steel wire less than 0.9 mm dia complete all as specified and dierected.
All as per item above 16 but 08 mm dia and over upto and including 8 mm dia , complete all as specified and directed.
All as per item above 16 but 5 mm dia and over upto and including 10 mm dia bars as in stirrups, spacers and binders, complete all as specified and directed.
Returning, filling in trenches including shearing , leveling, watering in layers n.exc 25cm thick soft loose soil complete all as specified and directed.
Removal of excavated soil n.exc 50mtr distance and depositing where directed n.exc 1.5m above the starting point complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:4) mixed with water proofing compound on brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. NOTE : Water proofing compound shall be measured and paid separately.
M&L 10mm thick plaster on other than brick surface with CM 1:6 finished fair and even without using extra cement, complete all as specified and directed.
Supply only integral water proofing compound.
5mm thick cement plastering in cement mortar 1:3 on fair faces of concrete ceiling surfaces finished even & smooth without using extra cement complete all as specified and directed.
M&L for preparation of new wall surafaces plastered or unplastered and applying three coat white wash on undecorated surfaces complete all as specified and directed.
Preparation of new plastered or unplastered surfaces and applying three coats of white wash on ceiling surfaces complete all as specified and directed.
M&L for preparation of preparation of new plastered or un- plastered surfaces and walls including cornices, pilasters etc and applying Two Coats of cement base paint complete all as specified and as directed.
M & L for two coat of distemper with oil emulsion on wall including preparation of new plastered or unplastered surface including washing rubbing down and stoping of distempered and painted surface complete all as specified.
Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for hard core of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick broken stone, water and ramed to atrue surfaces complete all as specified and directed.
M & L for 100 mm thick PCC 1:4:8 , D2 (40mm graded crushed stone aggregate ) as in sub-base coarse complete all as specified and directed.
Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shade, over 15 mm thick screed bed or bedding layer of mortar for laying floor finishes in cm 1:6 complete all as specified and directed.
Glazed ceramic tiles in vertical surface 350x 250x 7 mm / 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match shade, 10mm thick rendering on brick work or concrete surfaces as backing coat in CM 1:4 surface prepare to receive wall, complete all as specified and directed.
M&L PCC 1:3:6 Type C-2 (using 40mm graded stone aggregate) as in plinth protection, foot path, paved area, etc finished even and fair without using extra cement 75mm thick complete all as specified and directed.
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory made solid panel pvc door shutter 30 mm thick (style) con-sisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be cov-ered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement suppling & fixing at site as per specification and drawing complete all as specified and directed.
M&L butt hinges medium grade cold rolled mild steel and fixed size of hinges 100 mm long size
S/F Aluminium anodised barrel tower bolt of extruded section and fixed 150 mm long.
S&F Aluminium handle cast type anodised 100 mm long.
Material and labour for Steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel, complete complete with one coat of red oxide primer, complete all as specified and directed.
Material and Labour for Pin headed frosted glass pane 3mm thick & glazing with oil putty in square in not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S&F 20mm bore GI water tubing medium grade laid in floors or fixed in wall with GI fittings, , complete all as specified and directed.
S&F15mm bore GI water tubing medium grade laid in floors or concealed in walls with GI fittings, complete all as specified and directed.
S&F PVC (SWR) 110mm dia single socketed in any length with rubber ring joints laid in trenches or in floor / wall all as per specified.
S&F PVC (SWR) 75mm dia single socketed in any length with rubber ring joints laid in trenches or in floor /wall all as per specified.
S&F PVC (SWR) 110mm dia bends in any radius, complete all as specified and directed.
S&F PVC (SWR) 110mm dia junction single T equal or un equal , complete all as specified and directed.
S&F in repair vitreous china wash down water closet (pedestal pattern) with plastic seat cover including PVC low level flushing cistern 10 ltrs capacity complete as directed by Engr-in-Charge.
S&F in repairs vitreous china squatting pan 'orissa' pattern size 580x470mm white with integral foot rest (excluding flushing cistern and flush pipe), complete all as specified and directed.
S&F cast iron P or S traps all as directed by Engineer-in-Charge.
Liquid Soap container of PTMT fixed with and incl chromium plated brass screwes and wooden/plastic cleats (miminum wight 105 gms)
S&F for 15mm dia of pipe bib taps cast copper alloy, fancy type, chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
S&F 15mm bore angle stop cock, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe, complete all as specified and directed.
S&F PVC low level flushing cistern of 10 ltrs capacity incl flush pipe, complete all as specified and directed.
S&F for PVC Connection pipe 15mm size with PTMT nuts of length 450 mm , complete all as specified and directed.
S&F vitreous china wash basin, size 550 x 400mm white including brackets, and waste coupling & pipe of 32mm dia, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed, complete all as specified and directed.
S & F vitrious china urinal, half stall type, white including spreader, flush pipe and waste pipe. CP waste coupling, complete all as specified and directed.
S&F 15mm bore self-closing taps, cast copper alloy chro-mium plated screwed for iron pipe and fixed, complete all as specified and directed.
S&f Vitreous china urinal partition wall white of size 310x700 mm, complete all as specified and directed.
S&F pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shqanks and flynuts, screwed for iron pipe 15mm dia complete all as specified.
S&F 15 mm dia stop valve cast copper alloy chromium plated screw down high pressure with crown or capastan head screwed both ends for iron pipe complete all as directed by Engr-in-Charge.
S&F Chromium plated shower rose of 125mm dia complete all as directed by Engineer-in-Charge, complete all as specified and directed.
S&F toilet paper holder, coloured vitreous china, box type, complete all as specified and directed.
S&F soap dish, vitreous china white, aprox size 160 X 160 X 90 mm, complete all as specified and directed.
S&F Glass shelves, with 12mm thick desher glass incl CP brackets with brass nuts 300 mm long, complete all as specified and directed.
S&F mirror of size 450x600x5mm thick with aluminium frame and mounted on 6mm ply confirming to IS, with two Nos of hanging hooks, complete all as specified and directed.
S&F CP towel rail 600mm long with brackets, chromium plated 20mm dia, complete all as specified and directed.
S&F CP Health faucet for EWC, complete all as specified and directed.
S&F PVC (SWR) 75mm dia floor trap plain with grating including jointing with solvent cement, complete all as specified and directed.
M & L for preparation of newly untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks, capacity in litres 500 (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, complete all as specified and directed.
Ball valve 20mm high pressure of PTMT with epoxy coatet alluminium rod & high density plastic ball screwed for iron pipe and fixed, complete all as specified and directed.
S&F 20mm gun metal, globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed, complete all as specified and directed.
M & L for precast cement concrete1:2:4 type B-1 using 20 mm stone aggregate as in manhole cover slabs round square or rectangular in shape and set in CM 1:4, complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement incl firms moulds, complete all as specified and directed.
Reinforced concrete pipes, class NP2 laid and jointed complete with collars bore in pipes 150mm , complete all as specified and directed
M & L for cement concrete bed (1:3:6) type C-2 using 40mm graded stone aggregate to drain pipe of 150 mm bore including packing under hunching against the site of pipe after they are laid and tested, complete all as specified and directed.
25 mm thick (average) cement screed in CM 1:4 on roof (tiled or concrete surfces) finishing even and fair all as specified, complete all as specified and directed.
Providing and laying 3mm (-0.2/+0.3) thick APP with mineral finish (Atactic Polyproplene Polymer) modified prefabricated five layer, weight not less than 3.6 Kg/sq.m water proofing membrane mineral finished, reinforced with non-woven polyster matt make as approved including of a coat of bitumen primer @ 0.40 ltr/sq.m by the same membrane manufacturer of density 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70 - 160 cps over the coat, 4mm th 5 layered APP membrane mineral finish shall be laid using butane torch and sealling all joints etc after the surface complete as per standard practice as per manufacturers instructions. The vital physical and chemical parameters of the membrane shall be as under - (i) Tensile strength in longitueinal and transverse direction as 600±150/400±150 N/5cms (ii) Tear strength in longitudinal and transverse direction as 300 / 200 N/. Softening point of membrane not less than 145 degree (iii) Penetration @25 C d 15-25mm (iv) Water Tightness 10 kPa (v) The laying of membrane shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed.
Applying one coat of bituminous primer confirming to IS-3384 @ 0.3 Ltr/Sqm, complete all as specified and directed.
Applying one coat of aluminium paint over APP membrane @ 0.50 litres per Sqm, complete all as specified and directed.
Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg per square metre including cleaning the surfaces, complete all as specified and directed.
M & L for PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation complete all as specified and directed.
M & L for PCC (1:3:6) type C-1 using 20mm graded aggregate as in coping including necessary form work all as specified and directed
M&L for 15 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using any extra cement complete all as specified and as directed.
PVC(SWR)vent cowl 110mm all as specified.
PCC 1 : 2 :4 type B-0 (using 12.5 mm graded stone aggregate) 40mm thick over in sub base/floor /hard standing etc all as specified.
M&L for point wiring with 1.50 sqmm in copper conductor cable ( multistrand) FRLS single core PVC insulated cable in PVC concealed conduit ( ISI Marked) with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLS controlled by one switch for one light/fan/sockets point/ exhaust fan, all as specified and directed by Engr-in-Charge in ceiling Portion surface conduit wiring to be done. Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth iii) Cutting chasing wherever required for concealing the conduit shall be part of Job at no extra cost iv) Making Good the disturbed surface matching with existing shall be part of Job.
All as per serial item No 88 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 1.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
S & F modular socket multipurpose 2/3 pin 6/16 Amps 2 module, , complete all as specified and directed.
M/L for modular switch piano type 6 Amps single pole one way, one module, complete all as specified and directed.
M/L for modular switch piano type 16 Amps single pole one way, one module, complete all as specified and directed.
Material and labour for ceiling rose surface type, 65 mm x 50 mm three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed by the Engineer-in-Charge.
S& F blank spacer plate for single module, complete all as specified and directed.
S&F sheet metal enclosure (for DB's when MCBs to be used), single pole and neutral double door, 4 way, 240 Volts, concealed in wall, including making good the distubed surface, complete all as specified and directed.
Supply and fix in replacement of MCB SP up to 6-32 Amp all as specified and directed.
Supply and fix in replacement of MCB SPN 6-32 Amp complete all as specified and directed.
Supply and fixing LED Regal batten (suitable for fixing 20 watt LED rod) upto 1x22W (Single side), complete all as specified and directed.
Supply and fixing LED tube light Photon ultra (1 x 20W Single side connection) 1x20W LED tube rod, complete all as specified and directed.
Supply and fix LED tube light fitting 10 watt complete with all accessories, complete all as specified and directed.
Supply and fix exhaust fan AC single phase 230Volts of size 300 mm sweep, heavy duty, 1400 RPM with metallic body, lowers complete opening in wall with suitable size for fixed Exhaust fan incl make in good to the disturbed surface MS bolts, grouted to wall and connecting up including provision in cable from connector to fan with flexible cable 24/0.2mm with copper conductor and necessary fitting arrangements complete all as specified and directed at site.
M&L drilling and tapping cast iron water mains (in position) for branch connections of internal dia 15 mm
Supply and Fixing testing and commissioning water cooler of capacity 60/120 ltrs fully stainless steel electric , 240 volts, 5 star rated, insulated fitted with stainless inner container and , fixed PCC platform incl PVC connections all as specified and directed
Supply and spread sand in trenches as sand cushioning to underground cable for protection with dry fine river sand and provide required cover after punning down complete all as specified and directed. (Note: Thickness of sand cushion after punning down will be measured and paid.)
Supply and laying well burnt sub class ‘B’ bricks ( designated 75) locally available best quality, laid dry in trenches for protection of underground cable all as specified and directed.
Taking up/down worn out/damaged/unserviceable xlpe /PVC insulated underground cable armoured, heavy duty with aluminium conductors of any size, 1100 Volt grade from trench/duct/pole/wall/pipes/rooftops etc. complete all as specified and directed.
Supply, laying, Jointing connecting LT UG cable XLPE insulated,PVC bedded galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm 2 core laid in trenches / on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed. .
All as per serial item No. 107 above but for 10 Sqmm 4 Core.
All as per serial item No. 107 above but for 16 Sqmm 4 Core.
All as per serial item No. 107 above but for 25 Sqmm 3.5 Core.
All as per serial item No. 107 above but for 35 Sqmm 3.5 Core.
All as per serial item No. 107 above but for 50 Sqmm 3.5 Core.
All as per serial item No. 107 above but for 70 Sqmm 3.5 Core
All as per serial item No. 107 above but for 95 Sqmm 3.5 Core.
Supply and laying GI tube light grade of 25mm bore, as in cable protection pipe including all fittings, laid in trench, complete all as directed. Note :- Earth work shall be paid seperately.
All as per serial item No. 115 above but for 40 mm bore
All as per serial item No. 115 above but for 80 mm bore
Material and labour for cutting of road/ hard standing n exc 20cm width and n exc 60cm in depth for laying of cable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1 to match with existing surface complete all as directed.
b) Outgoing (i) MCCB 315 Amps rating and 36 KA rupturing capacity - 02Nos (iI) MCCB 250 Amps rating and 36 KA rupturing capacity - 02Nos (iIi) MCCB 63 Amps rating and 36 KA rupturing capacity - 01Nos
(b) Outgoing (i) MCCB 250 Amps rating and 36 KA rupturing capacity - 02Nos (ii) MCCB 200 Amps rating and 36 KA rupturing capacity - 02Nos (iii) MCCB 160 A rating and 25 KA repturing capacity - 02 (iv) MCCB 63 Amps rating and 36 KA rupturing capacity - 01Nos
Outcoming (i) MCCB 250 Amps rating and 36 KA rupturing capacity - 02Nos (ii) MCCB 150 Amps rating and 36 KA rupturing capacity - 01Nos (iii) MCCB 63 Amps rating and 36 KA rupturing capacity - 01Nos
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized iron 25 x 4 mm strip as earthing lead by means of galvanized steel bolts, nuts check nuts and washers and other end connected with to Transformer ,DG set,Panel Board etc as directed including funnel, 20mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1with 8mm dia cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, including earth work as required complete all as shown in electrical plate No 5 of MES Schedule Part I and testing complete all as specified and as directed.
Supply & fixing Earth continuity conductor or Main earthing Lead Fixed to wall on suitable procelain insulators of size 25 x 3 mm Aluminium Strip including all as directed .
NARINDER KUMAR SONS
R D Bansal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .