| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-Finance 272 VIKAS KUNJ VIKAS PURI NEW DELHI 110018 | WEST | DELHI | 110018 | ₹2.0 L | L1 | Accepted-Finance ok |
| 2 | L2₹2.4 LAccepted-Finance | ₹2.4 L | L2 | Accepted-Finance ok |
| 3 | L3₹2.8 LAccepted-Finance | ₹2.8 L | L3 | Accepted-Finance ok |
Tender Value
₹3.2 L
EMD Value
₹6,414
Closing Date
9 Feb 2026, 3:00 pmClosed
Assistant Engineer ( E )
Assistant Engineer ( E ) NWESD-II, PWD, Pitampura Police Lines,Delhi
Electrical work and SITC of window type ACs and providing fans, fittings at The office of community center(ICDS) wazirpur delhi -110052
2026_PWD_286012_1
175/EE(E)/AE(E)-II/NWED/PWD/ 2025-26
Open Tender
Electrical Works
30 days
Wazirpur
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹6,414
Yes
12 Feb 2026
2 Feb 2026
9 Feb 2026
2 Feb 2026
9 Feb 2026
2 Feb 2026
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. a) Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. a) 3 x 1.5 sq. Mm
b) 3 x 4 sq. mm
c) 6 x 4 sq. mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm
Supplying , Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll / rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. Sound level of up to 50dB inside the room is acceptable. The unit shall be in confirmation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 0C. The system shall be able to operate up to 50 0C (out door ambient temperature). a) 1.5 TR with fixed speed 5 Star BEE rating
Fabrication, Supplying & fixing of wire mesh protection frame work made out of 40 mm x 6 mm thick angle & "T" iron, strengthened with intermediate members of MS flat iron of size 30 mm x 5 mm thick welded at a distance of 30 cm horizontally & vertically and duly welded with wire mesh of size 75 mm x 25 mm made with 6 SWG wire on all sides and top i/c providing and fixing of double door gate with double locking arrangement (Two Nos. sliding bolts and One No godown lock) having 0.5 mtr long legs of 40 mm x 40 mm x 6 mm thick angle iron, duly grouted in cement concrete foundation ration 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate), up to suitable depth painting with one coat of red oxide & two coats of synthetic enamel paint of approval colour and shade etc complete as reqd.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. a)3 Module (100mmX75mm)
a) 6 Module (200mmX75mm)
c) 12 Module (200 mm x 150 mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 15/16 A switch
b) 6 pin 15/16 A socket outlet
d) 5/6 A switch
e) 3 pin 5/6 A socket outlet
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). a) 36 watt
SITC of wall fan 400 mm sweep oscillating type having plastic blade complete with all accessories such as front jaali i/c connection etc. as reqd
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 12 way, Double door
b) 16 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
b) Single pole and neutral
c) 63 A, 10 KA , SPN MCB (C-Curve)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required.
Providing and fixing Powder Fire Extinguisher (Stored Pressure type) Capacity 06 Kg duly ISI marked conforming to IS: 15683:2006, with IS 4308, ISI marked ABC powder complete with squeeze grip release valve, discharge pipe, locking arrangement, pressure gauge,operation manual and bracket. Operating Temperature: 30ºC to + 60ºC. complete including testing and commisioning etc as required.
Providing and fixing CO2 type Fire Extinguisher ISI marked conforming to IS: 15683. Capacity 4.5 Kg Complete with delivery hose horn, wheel type release valve, locking arrangement, operation manual and bracket. Operating Temperature:- 30ºC to +60ºC.testing and commisioning etc as required.
S/I/T/C of 1200 mm sweep BEE star rating energy efficient ISI marked ceiling fan capacitor type with double ball bearing suitable for operation of single phase AC supply with power Consumption of Max. 50W capable to deliver 220 CFM (min.), speed of 350 rpm (min.) i/c wiring the down rod of standard length (upto 30 cm) with 1.5 Sqmm FR PVC insulated copper conductor single core cable etc as reqd.
Supplying & fixing of 300-305 mm sweep 1400 RPM 230 Volt 1-ph 50 Hz AC heavy duty Exhaust fan in the existing opening including making good the damage, connection, testing and commissioning etc. as reqd.
Supplying, Installation, Testing & Commissioning of Water dispenser (with water storing bottle ) suitable for operation 230-240 Volt 50 Hz AC supply having heating and cooling capacity of minimum 3 litre/hour with storage compartment , auto shut off and capable of dispensing hot, normal and cold water etc. as required.
SITC of surface mounted IP65 rated LED bulkhead luminaire of nominal lumen output of 700 lumens with minimum efficacy of 100 lms/watt with glare free polycarbonate diffuser having colour temperature of 6500k, CRI>80 in aluminium housing body complete with all accessories with suitable LED driver etc. including PVC connector & PVC flexible conduit from light point to fitting and connection with 3 x 1.5 sq. mm copper wiring etc. complete as reqd.
Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). a) 100 watt
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi core cable in then existing surface/ recessed steel/ PVC conduit/channel as required. a) 3 core 4 sq. Mm
Credit for following old/dismantle material received from site i/c dismantling and removal from site. a) Assorted Cu wire
b) Assorted switch ,socket ,GI box,MCB,Regulator,Bell etc
c) Assorted DBs , Enclouser
d) Assorted LED Battens, Down lighter
e) Assorted Ceiling Fans/ Wall Fan/ Ex fan
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.61 MB
BOQ_378586.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid