Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹33.8 L+₹3.9 L (13.0%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹34.4 L+₹4.5 L (14.9%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹38.2 L+₹8.2 L (27.5%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
12 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
COMPREHENSIVE MAINT WORKS OF MH BHOPAL 21 CGSR 755 I TPT ASC SUPPLY DEPOT CTO COLONY IN BAIRAGARH AREA UNDER GE BHOPAL
2024_MES_665914_1
8304/E8
Open Tender
Civil Works
Item Rate
183 days
BHOPAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹90,000
Yes
19 Oct 2024
13 Jul 2024
14 Sept 2024
13 Jul 2024
12 Sept 2024
27 Jul 2024
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Taking down cement plaster on brick or stone wall etc including raking out joints, hacking for key, scrubbing down with water or cement lime plaster any description complete all as specified and directed.
M&L for 15mm thick rendering in cm 1:4 faces of brick or concrete surfaces (External surfaces) mixed with water proofing compound @ 3% by weight of cement, finished fair, even and smooth without using any extra cement complete all as specified and directed. Note :- (i) Water Proofing compound shall be measured and paid seperately. (ii) Rate is inclusive of scaffolding upto height of 12 m.
M&L for 15mm thick rendereing brick or concrete surface in CM 1:6 finishing the surface fair & even without using extra cement complete all as specified and directed.
M&L for 5mm thick rendering in cement mortar 1:3 on concrete surfaces as in ceiling including finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
Supply only integral water profing compound complete all as specified and directed.
Dismantling structural steel work including purlins, trusses etc. complete all as specified and directed.
Dismantling of timber scantling in fillets, rails, posts, rafters, purlins etc 40 sqcm and over in section, in any posotion for unframed works complete all as specified and directed.
S&F steel work in tubular/angle trusses including special shaped washers, purlins, rafters, posts etc complete all as specified and directed.
Dismantling of asbestos cement/FRP/Galvatume sheets (Corrugated, semi corrugated, etc) sheets including ridges in roof covering complete all as specified and directed.
S&F of pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall fixed with L or J hook 6 to 8mm dia with bitumineous washers etc to protect of seapage and leakage complete all as specified and directed.
M&L for applying heritage/texture finish of approved design/colour over cement plaster on wall and finished complete all as specfied and directed. Note :- Each stage i.e. preparation of surfaces, application of primer, application of first coat, application of second coat will be got passed.
M&L for dampness rectification in toilet area/corridor area filling tile joints with epoxy grout clearing all tile joints with grinder and removing existing cement grout, cleaning the surface to remove all foreign material applying masking tape around to joints filling tile joints with epoxy grout removing the tape & cleaning tiles with thinner & acid to make it stain free complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed.
M&L for machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing and including 20mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
All as per item 14.00 here-in-before but in skirting over 15mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including point ing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for rounding to edges of stone one edge such as in steps, cooking platform and other similar situation complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the permises complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7mm to 8mm thick (square /rectangular ) area of each tile exceeding 0.11 sqm but not exceeing 0.18 sqm in floors over and including 15mm thick screed in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles compelte all as specified and directed
M&L for non skid ceramic coloured tiles 7mm to 8mm thick (square /rectangular ) area of each tile exceeding 0.11 sqm but not exceeing 0.18 sqm in skirting over and including 10mm thick screed in CM 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles compelte all as specified and directed
M&L for glazed tiles , coloured 300x450 x 6 to 7 mm thick as in skirting/dado, over and including 10mm thick rendering in CM 1:4, set & jointed in neat cement slurry & pointed in white or coloured cement complete all as specifeid and directed .
M&L for vitrified ceramic tile light shade 8-10 mm thick (square /rectangular) polished, area of each tile not exceeding 0.36 sqm as in floors/skirting, over and including 20mm thick screed bed in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles compelete all as specified and directed.
M&L for vitrified ceramic tile light shade 8-10mm thick (Square /rectangular ) polixhed , area of each tile not exceeding 0.36 sqm on vertical surfaces such as skirting dado and risers to steps etc over & including 10mm thick rendering in CM 1:4 set & jointed in neat cement slurry & pointed in white or coloured cement to match complete all as specified and directed.
M&L for water proofing treatment to sunken surfaces of slab including in following sequence complete all as specified and directed:- (a) Slope correction providing PCC 1:1.5:3,type B0 (using 12.5mm graded stone aggregate), average thickness 25mm, mixed graded stone aggregate, mixed with integral water proffing compound "DITCHTMENT DM' manufactured by Dr fixit Pidiproof LW +, of M/s Pidilite Industries or STP No 1 (Liquid) of M/S STP Ltd as approved by GE, in proportions as suggested by manufacturer. (b) Applying evenly a priming coat of bituminous primer confirming to IS-3384 @ 0.7 Kg per Sqm on prepared surfaces. (c) Applying evenly a coat of hot blown bitumen of grade 85/25 @ 1.5kg/sqm on the primer surfaces. (d) Laying 150 micron thick black polyethence film on the suface with 10mm overlaps sealed and bounded the surface. (e) Applying evenly a coat of hot bown of grade 85/25 @ 1.5 kg per sqm on the surfaces. (f) 72 hrs testing of treatment for water thightness by ponding of water.
M&L for dampness rectification on wall area in following sequence complete all as specified and directed:- (i) Surface Preparation:- Removing existing putty/plaster/POP surface from the affected wall with wire brush/grinder/hammer etc up to brick level. (ii) Coating:- Applying two coats of Dr Fixit Pidifin 2k/Equivalent (a two component, anti-fungal, acrylic waterproofing coating) over cleaned surface with brush and allowing it to dry for 24 hours . (iii) Finishing the surface:- Applying plaster & putty over the treated surface with waterproofing compound mixed with putty & plaster to provide proper finish after that painting can be done after proper curing.
Taking up or down 15mm bore GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
S&F of 15mm GI tube, medium grade, with all necessary fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
Taking up or down 20 mm bore GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
S&F of 20 mm GI tube, medium grade, with all necessary fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
Cutting chases, pinning in, making good to facings in brick wall where required and pointing in cement mortar 1:3 to ends cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 20 cm girth complete all as specified and directed.
S&F in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm complete all as specified and directed.
S&F in repairs 15 mm pillar taps, fancy type, cast copper alloy, chromium plated, screwed down high pressure, with or without lettered "Hot or Cold" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair 15 mm bib taps, chromium plated , screwed down, screwed for iron pipe or for brass ferrule and fixing complete all as specified and directed.
S&F 15 mm stop valves, cast copper alloy, chromium plated, screwed down high pressure, with crutch or butterfly handle, scrwed both ends for iron pipe or for unions and fixing complete all as specified and directed.
S&F in repairs 15mm bore stop cock, cast copper alloy, chromium plated with long shank and cup (concealed type) screwed down, screwd for iron pipe or union and fixed in repair complete as specified and directed.
S&F in repairs 15 mm pillar taps, fancy type, chromium plated, with extended lever handle and wall flange elbow operated fixing complete all as specified and directed.
S&F in repairs 15 mm bore bib taps, long body, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferulle and fixed complete all as specified and directed.
S&F in repairs 15mm dia, brass CP wall mixer for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and directed.
S&F in repairs 15mm dia, brass CP centre hole basin mixer for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and directed.
S&F in repairs brass chromium plated shower rose 125mm in size with or without swivel joints any size including fixing to steel pipe or union , complete all as spfecified and directed.
S&F in repairs 20 mm (curtain rail) mild steel, chromium plated, fancy type with fixing brackets, stops, rollers etc complete all as specified and directed.
M&L in repair 18/19mm thick WPC panels for wardrobes, shelves, partition of kitchen cabinet fixed with screws to WPC frame work complete. WPC panels (shutters) to be with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws complete all as specified and directed. Note : S.S butt hines and screws etc shall be including.
S&F for 100mm, hasp and staple, safety type, anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed
S&F repair 40mm dia cupboard/kitchen cabinet knobes fixed with nuts, screw and washer of MS, bright finshed complete all as specified and directed.
Taking down chowkhats or frame with shutter n.exc 1.5 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed
M&L for fabricating and fixing powder coated (minimum 50 miciron) aluminium sections of required size for doors, windows, any type, frames and partitions including aluminium hinges of required size jointing cleats, screws salsh fasterners, plug for fixing with walls, column etc including taking down damage portion of damage door, windows or taking down complete door/ window complete all as specified and directed. Note :- Rates are inclusive of necessary new fitting for door/ window i.e handle, tower bolt, butt hinges etc.
M&L for framed work such as grills, gratings, gate etc with ends of bars souldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railing, frame work of water tanks and similar work conforming to Fe-290, Gde E-165 complete all as specified and directed.
S&F of 5.5 mm thick plain glass and glazing with putty /uPVC beading including rubber packing, fixing glass to UPVC surrounds complete all as specified and directed.
S&F for stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples to uPVC door with beading complete all as specified and directed.
S&F of 4 mm thick, sheet glass, ordinary quality and glazing with oil putty in square n.exc .50 Sqm in each panels incliduing hacking out old broken glasses complete all as specified and directed.
S&F of steel ventilator with top hung shutters including hinges with fixed type MS handles peg stay and tower bolt but with additional sash bars MS flats for fixing of wire gauge complete all as specified and directed.
S&F 3 mm thick figured glass, pin head type and glazing with oil putty in squares not exc 0.5 sqm in pane complete all as specified and directed.
S&F in repairs galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed and with stainless steel wire staples fixed complete all as specified and directed.
S&F of solid PVC door frame of size 50 mmx 47mm made out of 5 mm plain colour PVC sheet reiforced with MS square tube and fixing in opening as per manufacturer instruction complete all as specified and directed.
S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement complete all as shown in SSR-2004 Part - II, specified and directed.
Taking down door shutter any description exc 1.0 sqm but n.exc 2.00 sqm each complete all as specified and directed.
Taking down chowkhats or frame with shutters exc 1.5 Sqm but not exc. 4.00 Sqm each (without taking off shutters from the frame) complete all as specified and directed
M&L for 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides and both face is covered with decorative face 0.9mm mica with lipping/frame to match all as specified and directed
S&F of second class wood 30mm thick glazed and skelton shutter open rebeted and prepared to receive glass gauge etc (with sash bar) edges of framing plain champhered or rounded fitted with cut and mitred beads for secauriing glass complete all as specified and directed.
S&F of 105X60mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete as specified made out of 1.25mm thick MS Sheet complete all as specified and directed.
S&F of 125X60mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges lock strike plate etc complete as specified made out of 1.25mm thick MS Sheet complete all as specified and directed.
S&F for factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 65x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 ms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 modules of elasticity 900 N/mm2 and resistance tospread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position with MS hold fast/lugs/SS dash fasteners of required dia andlength complete all as specified and directed. Note:-1. M.S. hold fast/ lugsor SS dash fasteners shall be paid separately. 2. WPC solid door/window frames,minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimension plus side shall be acceptable but no extra payment on this account shall be made.
S&F for factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and nontoxic additives (maximum toxicity index of 12 for 100gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2and resistance to spread of flame of Class A category with property of being termite/borerproof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed.
S&F for providing factory made 30mm thick 100% Solid WPC (Wood polymer Composite) laminated wiremesh door shutter of required size comprising of virgin PVC resin of K Value 57-60 (Suspension Grade), Calcium Carbonate and natural fibers (Wood Powders/rice husk/ wheat husk) and Non toxic additives, made from extrusion process WPC foam sheet single extruded (inner) with having minimum density not less than 650 kg/cum manufactured by "RAJSHRI" an ISO 9001 - 2015 certified company, having good screw holding capacity (Screw withdrawal strength of 2000 N (Face) & 1100 N (Edge), minimum compissive of 50 N/mm2 , modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being termite/borer free. Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter. For fixing Mosquito mesh and XTN aluminium mesh combinly panel area of door except stiles and rails to be panelled with mesh with self tapping round headed scresws at required distance, scres and edges covered with feathered pvc edge beading all around of mesh and fixing stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws complete all as specified and directed. Note:- Material test certificate and authentication should be compulsory provided by the manufacturing company.
S&F 100 mm mild steel, butt hinges, medium weight, cold rolled complete all as specified and directed.
S&F 150 mm aluminium handles, cast type, anodised complete all as specified and directed
S&F 150mm aluminium anodised, barrel tower bolts extruded section and fixed complete all as specified and directed.
S&F 200 mm aluminium anodised, barrel tower bolts extruded section and fixed complete all as specified and directed
S&F 300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed
S&F in repair brass, mortice lock, 4 levers, vertical type size 100mm as specified and directed
M&L preparation of new surfaces of wall including brooming, scraping down smoke spot, moulds, moss, effloresecent salts trading oil, greasy spots and stopping nails marks and applying two coat of cement base paint over a coat of primer complete all as pecified and directed.
M&L for preparation of newly plastered or unplastered surfaces of walls and applying two coats of oil bound distemper complete all as specified and as directed.
M&L for applying one coat of white wall putty on walls complete all as specified and directed.
M&L for three coats of white wash over ceiling including preparation of surface complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall including brooming, scraping down smoke spot, moulds, moss, effloresecent salts trading oil, greasy spots and stopping nails marks and applying one coat of oil emulsion distemper complete all as pecified and directed. Note : Required scafolding is included for painting at any height.
M&L for Preparing old decorated plastered or unplastered surfaces of walls and applying one coat of exterior acrylic emulsion paint, white or tinted complete all as specified and directed. Note : Required scafolding is included for painting at any height.
M&L for water proofing of terrace/roof surfaces are following steps:- a) Surface preparation by thoroughly by cleaning, washing and removing dust, dirt, oil, grease and loose particles. Ensure the roof slope is minimum of 1 in 100 to enable water run off. b) Surface crack must be filled with Dr Fixit crack X or polymer modified mortar in case of wider cracks. Bitumen based waterproofing treatment must be completely removed by mechanical scarification or by any other effective mechanical means. c) Self priming - Apply one coat of Dr Fixit roof seal top coat (diluted with water in the ratio 2:1) at the rate of 100-110 sq ft/ lit . Allow it to dry for 24 hrs. d) Providing and applying two coats of Dr fixit roof seal top coat over self primed surface by roof seal top coat (2:1) embed a glass fibre mesh (2mmx2mm- 40 gsm) between the first and second coat as reinforecement to strengthen the coating. e) Work will be done through authorised applicator
Complete removal of existing treatment of external surfaces of wall/chajja/roof projection including removing fungus/algea by wire brush and applying three coats of Shalimar Acrylic water proof coating, " Shalicryl 215" (UV resistant, Elastomeric exterior water proof coating of Premium quality) manufactured by STP Ltd. To use, first coat as a primer coat water be added in the ration 1:3 (1 part shalicryl 215 & 3 parts of water) and in subsequnt coats 10% water shall be addded to make it to a brushable consistency all as per manufacturers instructions including scaffolding complete all as specified and as directed. The tint of the coating should match with the existing surfaces and as directed. Make :- Shalicryl 215 manufactured by STP Ltd or equivalent product manufactured by Dr. Fixit/Chemistik.
M&L for grouting of slab/beam by fixing 12 mm dia PVC nozzle and pressure injection by cement slurry of 50 kg cement mixed pidicrete SM 225 gms of M/s pidilite industries Ltd or Cabex 100 of m/s Fosroc chemical with pressure not less than 2 kg/ Sqm including necessary drilling, nozzles, pluging etc as per manufacturer's instruction for grouting complete all as specified and directed.
M&L for preparing old decorated plastered or unplastered surfaces of walls and applying one coat of cement base paint, white or tinted complete all as specified and directed. Note :- Required scafolding is included for painting at any height.
M&L preparatration of old decorated surfaces of ceiling including brooming, scraping down smoke spot, moulds, moss, effloresecent salts trading oil, greasy spots and stopping nails marks and applying one coat of white wash on ceiling complete all as pecified and directed.
M&L for preparation new steel & iron surfaces of any description over 10cm in width or girth and applying two coat of synthetic enamel paint over and including a coat of red oxide zinc chrome primer complete all as specified .
M&L preparatration of old decorated surfaces of wall including brooming, scraping down smoke spot, moulds, moss , effloresecent salts trading oil, greasy spots and stopping nails marks and applying two coat of Anti bactorioal, anti fungus paint complete all as pecified and directed.
M&L for two coats of synthetic enamel paint over one coat of pink primer over 10cm width or girth on wooden surface including preparation complete all as pecified and directed.
M&L for 32 mm dia UPVC pipe as in water spout at the lowest point of sunken floor with 600 mm projection beyond the outer face of the wall with outer end cut in chamfered angle for easy drain of water complete all as specified and as directed.
S&F in repairs 32mm bore PVC waste pipe for kitchen sink /WHB one mtr long complete all as specified and directed.
S&F in repairs 40 mm bore PVC waste pipe for kitchen sink /WHB one mtr long complete all as specified and directed.
S&F in repairs 100mm dia CP grating (minium weight 25gms) complete all as specified and directed.
S&F in repairs PVC connection 15mm size PTMT nuts of length 600mm complete all as specified and directed.
S&F in repairs vitreous china squanting pan "orissa" pattern size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe) including cement concrete bedding complete all as specified and directred.
S&F of vitreous china oval shaped cunter top wash basin, white , flat back, Size 550x400mm /std size including waste pipe, coupling, PVC pipe connection 15mm dia 600mm long complete all as specified and directed.
S&F of china wash down water closet pan (Pedestal pattern), white, pedestal pan and 'P' or 'S' trap, plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F in repair vitreous china wash basin, white, flat back, Size 630x450mm including brackets, waste pipe, coupling, PVC pipe connection 15mm dia 600mm long complete all as specified and directed.
S&F in repairs plastic water closet seat, closed pattern with flat bottom and cover dand mild steel chromium plated or sluminised hinging device complete all as specified and directed.
S&F in repairs PVC low level flushing cistern of 10 ltrs capacity with all internal fittings including 32mm dia flush pipe and fixing to supply pipe including PVC connection 600 mm long 15 mm bore with brass heads & washers with connections fixed in repairs complete all as specified and directed.
S&F in repair health faucets CP with 1.2 mtr long CP flexible pipe complete all as specified and as directed..
S&F in repairs jet spray (butterfly) with 1 mtr tube complete all as specified and directed.
S&F in repair toilet paper holder of, mild steel chromium plated 'D' type, fixed to walls with chromium plated brass screws complete all as specified and directed.
S & F in repair EWC seat cover white/coloured plastic with fixing bolts & hinging device complete ISI marked.
S&F PVC (SWR) pipe 75mm bore single socketed, in any length with rubber ring joints, fixed in walls / laid in trenches/floors complete all as specified and directed.
S&F PVC (SWR) 75mm bore bends any radious complete all as specified and directed.
S&F PVC (SWR) junction single, (SingleT) 75mm bore equal or unequal all as specified and directed.
S&F PVC (SWR) junction single, (DoubleT) 75mm bore equal or unequal all as specified and directed.
S&F in repairs PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints laid in trenches, floors or fixed in walls complete all as specified and directed.
S&F PVC (SWR) 110mm bore bends any radious complete all as specified and directed.
S&F PVC (SWR) Junction (Single T) 110mm bore equal or unequal all as specified and directed.
M&L 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement all as specified and directed.
S&F in repair PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified & directed
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quions, arches, pillars, etc but excluding ashlar facings dressed stonework and precast articeles.
M&L for brick work with fly ash bricks straight or curved on plan exc 6 m mean radius, built in cm 1:6 all as specified and directed.
Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition) in any description and in any position not other wise specifically provided for complete all as specified and directed.
M&L for TMT steel bars of 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hookings ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed by Engr in Charge.
M&L for reinforced cement concrete (Nominal mix), type B-1 1:2:4 ( 20 mm graded stone aggregate) in foundation, raft, basement slab etc all as specifed and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping etc) all as specified and directed.
Taking down aluminium doors n.exe 4 sqm each and refixing in same position after carry out necessary repairs including replacing rubber/aluminium beading and jointing cleats, tightening if required including making good existing surface complete all as specified and directed. Note :- Any aluminium style, rail, frame, floor spring, hydrulic door closer if required to be replaced shall be measured and paid seperately.
S&F in repair Floor door stopper 150mm long of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F in repairs floor door stopper 150mm long of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F in repairs for double action floor spring, hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc.) or insulation board/slabs/blankets, any thickness including cover fillets complete all as specified and directed.
M&L for galvanised cold rolled steel section frame work size 600x600mm, grid size 24x38x0.50 (composite thickness) Tee (bottom pre-coated ) and size 24x24x0.50m (composite thickness) thick wall angle, galvanised cold rolled steel section including suspenders as per (Gapsec) manufacturs insturction as in ceiling complete all as specified and directed.
M&L for asbestos free calcium silicate board of size 600x600x6mm thick fixed to steel frame work as in ceiling, including applying two coats of oil bound distemper all as specified and directed.
M&L for running welding in repairs thickness of metal to be welded not exc 6mm thick including taking down the article and refixing in position after welding (if required) complete all as specified and directed.
Taking down existing water proofing treatment of any description including, PCC padding, cement plaster any thickness from roof surfaces, cleaning of roof and prepairing it for further treatment including make good necessary dubbing out wherever required and removing rubbish from site complete all as specified and directed.
M&L for provision of water proofing roof treatment to non accessible/accessible RCC roof with APP modified membrane with non woven polyster reinforced wt not less than 3 Kg/Sqm of thickness not less than 3 mm having thermal, insulation with white or plain finish on upper side of membrane uniformely embedded during manufacturing process incl taking down existing treatment all as per following specifications:- (a) 10 mm thick plaster in CM 1:4 mixed with and including water proofing compound @3% by weight of cement applied over roof slab. After the plaster is cured the roof will be tested for water tightening by ponding test with water for 72 Hrs for any seepage/leakages etc. if any seepage is oberved the rectification will be carried out by pressure grouting under the pressure of 5 Kg/Sqcm using cement based cement grout. After the surface is repired the slab will be tested for water tightness against before processing further treatments. (b) The surface of the roof, parapet and gutters, drain mouths etc. over which water proofing treatment is to be applied shall be cleaned of all foreign matters such as fungus, mass, dust etc. by wire brushing and dusting. For cast iron drain outlets the groove shall be cut around to tuck in the treatment as pipes, chimney stacs etc. and other similar situations to ease up about corners. (c) Bituminous primer conforming to IS : 3384-1965 @ 0.30 Kg/Sqm to be applied on prepared surface till the surface is properly impregnated. (d) APP modified water proofing membrane as specified shall be laid by torch application method laid on hot bitumen 85/25 grade at the rate of 1.2 kg/sqm primer surface as per manufacturers instructions. The overlaps while torching shall be 100 mm in both directions(longititudinal and transverse directions). All overlap joints shall be sealed throughly by thermofusing both the membrene layers and sealing it with the help of hot trowel. The overlap joints shall be made as monolithic layer. (e) All joints & changes in direction should be curved with cement morar 1:3 mixed with SBR latex @ 200 ml per beg of cement and cured well before laying the membrane. (f) A fillet of PCC (1:2:4) type B-0 of 100 mm x 100 mm shall be provided at all junctions of vertical and horizontal surfaces and wherever there is a change of direction. The membrane should not be taken over at any steep turns and hence all corners /junctions should be rounded.
M&L for providing, cement concrete type B0 1:2:4 (12.5 mm graded stone aggregate) mixed in benching, roof kerbs of mud stops, rounded or chamfered on edges, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directing complete all as specified and directed.
M&L for precast machine pressed Cement concrete tiles with grey cement and no pigments of size 25 cm x 25 cm x20-25mm thick, set, jointed and pointed in neat cement slurry in floors and cut and polished over and including bedding layer of 15mm thick screed in CM 1:4 as in roof complete all as specified and directed.
Demolition of cement concrete in floors and pavings not exc. 15 Cm thickness (below/above ground level) including floor finishes all as specified and directed
M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation, filling, subbase and mass concrete complete all as specified and directed.
M&L for cement concrete 1:5:10 type E-2 (using 40 mm graded stone aggregate) as in sunken filling, mass concrete complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) in plinth protection, aprons, hard standing, path and like including bitmuminous mastic filling in 1:3 joints(in every 3.00mtr) and finishing the surfaces even and smooth without using extra cement complete all as specified and directed
M&L for 20 mm thick screed Bed or bedding layer of mortar for laying floor finishes in CM 1:6 all as specified and directed
M&L for heavy duty flooring tiles , harsh weather & UV resistance, high abrasion resistance, MOH hardness >6 thickness 10 mm thick, area of each tile not less than 0.09 sqm, anti slip type laid in floors, steps, edges etc set and jointed in neat cement slurry and pointed in white or coloured cement to match tile with & including 15 mm thick rendering in CM1:4 complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block (Reflective type)in any shape and size confirming to IS-15658-2006 of 60 mm thickness M-35 grade with grey cement and pigment .
M&L sand filling under paver block watering and consolidation complete all as specified and directed.
M&L for cement concrete type B1 1:2:4 (20 mm graded stone aggregate) as in coping, door frame filling, benching etc for drain and similar works all as specified and directed.
M&L for providing PCC 1:2:4, type B0 (using 12.5mm graded stone aggregate) reinforcement for precast cement concrete jallies, 25mm thick (measured solid) including all mould- ings but excluding frame etc. complete all as specified and directed.
Supplying, fabricating and fixing 12 mm thick toughen glass for partition, doors etc including all necessary fitting and fixtures with hydrulic floor spring , embosing, ingraving work as requird complete all as specified and directed.
M&L for metalic ceiling T 24 plain/corrugated /semi corrugated poweder coated duly interlocked as in false ceiling board of width 100mm/ 150 mm 0.5 to 0.7mm fixed to steel frame work as in ceiling, including dismantling complete all as specified and directed.
All as per item No. 139.00 here-in-before but except material
M&L for cleaning of structural glazing/ glass incl necessary scaffolding upto 30 m height complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth, for foundations etc. or for shafts, well cess pits, manholes, pier holes, etc. but not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
M&L for returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified and directed.
Removing surplus soil obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting paint complete all as specified and directed.
Demolition or breaking up of salt glazed ware, AC or reinforced concrete drain pipes, 150 mm dia jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
M&L for 150 mm dia RCC NP2 drain pipes with collars laid in trenches and jointed as specified complete all as specified and directed.
M&L for concrete bed to drain pipes 150 mm dia including packing under, and haunching against the sides of pipes after they are laid and tested in 1:4:8 type D2 (using 40 mm graded stone aggregate) complete all as specified and directed.
M&L for precast cement concrete type B1 (20 mm graded stone aggregates) as in cover slab for manholes etc set in CM 1:4 complete all as specified and directed.
Dismantling posts or struts (wood, steel or RCC) any section embedded in concrete, masonry, brick work, incl taking out embedded portion and making good disturbed ground complete all as specified and directed.
S&F for mild steel works as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc and flat iron fillets for securing wire mesh similar work confirming to Fe-290 Gde E-165 etc all as specified and directed.
Excavating in post holes in any type of soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, including removing of surplus soil complete all as specified and directed.
Dismantling fencing wire mesh, any type complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed.
Supply only chain link MS galvanisd fencing, any size or type complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors, etc.complete all as specified and directed.
M&L for point wiring for one light /fan/bell point with 1.50 Sqmm (nominal area) FRLS, PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one-way switch, drawn in and including non metallic rigid PVC casing capping, ISI marked, not less than 25mm base size with all fitting and fixing accessories including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly by suitable lugs, sunken sheet, steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators, etc. with 3mm thick laminated hylum sheet cover complete all as specified and directed. Note : Wiring to be done as per approved colour code in IE rule.
All as per item No 156.00 here-in-before but for one light point controlled by two way switches
All as per item No 156.00 here-in-before but for 3 pin 5 Amp socket outlet on independent board
All as per item No. 156.00 here-in-before but for 3 pin 5 Amps socket outlet point controlled by one switch on same board with other switches
All as per item No 156.00 here-in-before but for wiring with 2.5 Sqmm copper cable for 5/15 Amp switch socket combination for 3 pin socket outlet 15 Amp, independent board and provision of 2.5 Sqmm, FRLS PVC insulated unsheathed multi-stranded single core earth wire for earth continuity, connected to common earth dolly.
All as per item No 156.00 here-in-before but wiring with 4.00 Sqmm, copper cable for 15 Amp switch socket, combination for 3 pin socket out let 15 Amp independent board and provision of 4.00 Sqmm, FRLS PVC insulated unsheathed multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
M&L for point wiring for one light/fan/bell point with 1.50 Sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one-way switch, drawn in & including non metallic rigid PVC conduit, concealed (ISI marked), medium grade, not less than 20mm diameter with all conduit accessories in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 (except on ceiling for fan point only, surface casing capping will be used in lieu of concealed PVC conduit) including one run of 1.5 Sqmm copper conductor as earth continuity wire connected to common earth dolly, sunk sheet steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators etc. with 3mm thick laminated hylum sheet cover complete all as specified and directed. Note : Wiring to be done as per approved colour code in IE rule.
All as per item No 162.00 here-in-before but for one light point controlled by two way switches.
All as per item No. 162.00 here-in-before but for 3 pin 5 Amp socket outlet on independent board.
All as per item No 162.00 here-in-before one 3 pin socket outlet 5 Amps on same board
All as per item No. 162.00 here-in-before but 3 pin socket outlet 15 Amps on independent board elect wiring 2.5 Sqmm
All as per item No 162.00 here-in-before but wiring with 4.00 Sqmm copper cable for 15 amp switch socket combination for 3 pin socket out let 15 amp independent board and provision of 4 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly
Taking down old/unserviceable switch piano/socket outlet /bell push/S-S combination/ceiling rose /bell ding dong /buzzer electric/old unserviceable tube lights fitting/mirror light fittings of any type complete all as specified and directed.
S&F in repairs switch piano, flush type, single pole, one way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and directed.
S&F in repairs switch piano, flush type, single pole, two way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and directed.
S&F in repairs Bell push, flush type, 6 Amp, piano type, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed.
S&F of switch piano, one way, single pole, 15 Amp, 240 volt, 50Hz, flush type, ISI marked complete all as specified and directed.
S&F in repairs socket outlet, multipurpose having provision for 2 & 3 pin, 6 Amp, flush type, 240 volt AC complete all as specified and directed.
S&F in repairs socket outlet 2 in 1, 3 pin 5 and 15 Amp flush type, 240 volt AC complete all as specified and directed.
S&F in repairs switch socket combination 2 in 1, type 5/6 Amps, flush type, 230 volt AC complete all as specified and directed.
S&F in repair, switch socket combination, outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, piano flush type, 230 volt AC complete all as specified and as directed.
S&F in repairs ceiling rose surface bakelite, three terminals, 240V, 50Hz, ISI marked complete all as specified and as directed.
S&F in repairs buzzer electric, single phase, 240 volt, AC complete all as specified and as directed.
S&F in repairs Bell, Ding Dong type, electric, single phase, 240 volt, AC complete all as specified and as directed.
S&F in repairs LED tube light fitting, surface mounted lumanaires, 1 x 20 W, 240V, decorative ultra slim round /squar profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack with bipin holders, LED lamps, connector block, etc. complete with all accessories internally pre-wired and including connecting up with 3 core flexible copper conductor cable of suitable size including taking down of old fittings complete all as specified and directed.
S&F in repairs LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size including taking down of old fittings complete all as specified and directed.
Taking down old unserviceable ceiling fan regulator/modular swich/modular socket/modular ceiling fan regulator/modular metal flush box/modular white cover of any type all as specified and directed.
S&F in repairs ceiling fan regulator electronic step type 240 V, AC 50 Hz single pole, 100 watts flush type complete all as specified and as directed.
S&F in repairs modular socket outlet 2-in-1, 5pin, 6 Amps, 240 volts, controlled by one switch complete all as specified and directed.
S&F in repairs modular socket outlet 2-in-1, 2/3 pin, 6/16 Amps, 240 volts, complete all as specified and directed.
S&F in repairs modular switch socket combination 2-in-1, 5 pin, 6 Amps, 240 volts, controlled by one switch complete all as specified and directed.
S&F in repairs modular switch socket combination, multipurpose 6 pin, 16 amp, 3 module complete all as specified and directed.
S&F in repairs modular fan regulator, 5 stepped, high speed complete all as specified and directed.
S&F in repairs modular switch, one way, 6 Amp, one module, 240 volts complete all as specified and directed.
S & F in repairs modular metal flush box of 6 module complete all as specified and directed.
S&F in repairs modular metal flush box of 4 module complete all as specified and directed.
S&F in repairs modular metal flush box of 3 module complete all as specified and directed.
S&F in repairs modular white cover plate of 6 module complete all as specified and directed.
S&F in repairs modular white cover plate of 4 module complete all as specified and directed.
S&F in repairs modular white cover plate of 3 module complete all as specified and directed.
Taking down old ceiling fan/exhaust fans/wall mounted fan of any capacity/sweep after disconnecting the electric supply from any site, checking for its electrical defect and opening fans for checking of mechanical defect after dismantling of fan, carried out repair/over hauling including removing dust and grease and cleaning of internal mechanical parts of fan with kerosene oil, checking of alignment of shaft, oiling and greasing, checking of worn out bearing and other defective parts, winding, condenser etc and re-assembling and connecting/refixing of fans in its original position by providing new GI nut bolt, lock washer and lock/split pin complete all as specified and directed. Note: (i) Rewinding and replacement of defective parts, painting etc shall be measured and paid seperately. (ii) Burnt out fan shall be kept separately and to be repaired/rewinded at AGE E/M yard and to be hanged in existing position after rewinding. (iii) Old ceiling fan will be deposited to MES Store.
Bearing No 6201
Bearing No 6202
Bearing No 6203
Bearing No 6204
Rubber bush as required at site suitable for ceiling fan Notes for ser items Nos 198.00 to 201.00 1. Repairing/ rewinding of ceilling fan/ exhaust fan shall be carried out in the AGE E/M Bairagarh sub-division in present of concern JE E/M. 2. Space/room will be provided by AGE E/M in the E/M yard for carring out repair work. 3. Contractor staff will collect defective fans from concern JE E/M, check the fans after opening it, and intimate the defects in the fan to JE E/M before carring out the repairs. 4. Contractor detail the staff electrician to attend the complaints of fans daily in morning from concern JE E/M and submit the report daily in the evening regarding the attended complaints.
Condenser 2.5 mfd
Condenser 4.0 mfd
M&L for rewinding of ceiling fan of sweep 1200 mm, any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed.
M&L for rewinding of ceiling fan of sweep 1400 mm, any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed.
Taking down old unserviceable blade assembly/U clamp/down rod of ceiling fan/wall mounted fan all as specified and directed.
S&F in repairs of blade assy of wall mounted fan of 400 mm, sweep complete all as specified and directed.
S&F in repairs 'U' clamp for hanging ceiling fan in ceiling to be fixed with 3" long ancher fasterner 3 Nos for each clamps complete all as specified and directed.
S&F in repairs of ceilling fan down rod of size 15mm GI pipe, medium grade, (ISI marked) length upto 1500 mm including making holes, nut bolts, spilit pin washers etc complete all as specified and directed.
S&F in repairs of PVC insulated multistranded copper conductor, sheathed round cable, ISI marked 1.0 Sqmm, 3 core complete including taking down old unserviceable cable all as specified and directed.
Taking down old unserviceable sub main wiring including service connections, of any size and any description including conduit pipe all as specified and directed.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable, 1100V unsheathed with stranded copper conductor of 4.0 Sqmm nominal cross section area and drawing into rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 20mm external diameter and PVC insulated stranded copper conductor of 4.0 Sqmm nominal cross section area as earth wire including taking down old unserviceable sub main wiring complete all as specified and directed. Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 4.0 Sqmm cable, one run of 4.0 Sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable, 1100V unsheathed with stranded copper conductor of 6.0 Sqmm nominal cross section area and drawing into rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 20mm external diameter and PVC insulated stranded copper conductor of 6.0 Sqmm nominal cross section area as earth wire including taking down old unserviceable sub main wiring complete all as specified and directed. Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 6.0 Sqmm cable, one run of 6.0 Sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
Taking down old unserviceable MCCB/MCB DB of any size and capacity including wooden boards complete all as specified and directed.
S&F in repairs sheet metal enclosure for MCB, DB, TPN, 415 Volts, 200 Amps rated busbar, 4 way, double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first class hardwood of suitable size for mounting of DB box complete all as specified and as directed.
Supply and fixing in repairs factory made epoxy powder coated Distribution Board TPN, 4 ways (VTPN and MCCB DB ) and space for MCCB as incomer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including isolated Neutral Bar, Insulated busbar assembly, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified and directed.
S&F in repairs sheet metal enclosure for SPN DB ( single pole and neutral) single door type surface mounted concealed in wall 8 ways, 240 Volts, IP 43 ISI marked 200 amps bus bar dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed.
S&F in repairs sheet metal enclosure for SPN DB (single pole and neutral), single door type surface mounted concealed in wall 12 ways, 240 Volts, IP-43, ISI marked 200 Amps bus bar dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed.
Taking down of old unserviceable MCB SP/SPN/PN/MCCB/ sheet metal earth plug socket of any capacity complete all as specified and directed.
S&F in repairs MCCB, 63 Amp, 3 pole, breaking capacity, 25 KA with complete electrical connections by appropriate size of copper lugs, complete all as specified and directed.
S&F in repairs MCCB 100 Amp, 3 pole, breaking capacity 25 KA with complete electrical connections by appropriate size of copper lugs, complete all as specified and directed.
S&F in repairs MCB SP, 240 volts, 10 KA breaking capacity 'C' curve, of capacity 6 to 32 amps including connection with suitable size aluminium/copper lugs complete all as specified and directed.
S&F in repairs MCB SP suitable for 240 volts, AC supply 40 to 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
S&F in repairs MCB SPN suitable for 240 volts, 'C' Curve, AC supply 32 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA, complete all as specified and directed.
S & F in repairs MCB SPN suitable for 240 volts, AC supply 40 to 63 Amps, 'C' Curve, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
S & F in repairs MCB TPN, suitable for 415 volts, AC supply 40 to 100 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
S&F in replacement sheet metal earth plug & socket, single pole and neutral with and including 1no. single pole MCB, 20 Amps 240 volts complete all as specified and directed
S&F in replacement, 3 pin plug top AC-230 V, 15 Amp, including taking down old unserviceable pin top complete all as specified and directed.
S&F in replacement PVC insulated, PVC sheathed, flexible circular cable 3 core, 2.5 Sqmm strandered copper conductor AC, 240 V including taking down old unserviceable cable complete all as specified and directed.
S&F in repairs LED, ultra slim decorative aluminium casted edge ceiling light, protuded type ceiling mounted LED 2 x 2, luminaire 36 watt with all accessories internally pre-wired and including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core ,complete including taking down old unserviceable fitting complete all as specified and directed.
S&F in repairs LED, sleek round recess mounting LED ceiling light 1 x 1 feet, decorative type aluminium casted edge ceiling light, recess mounting LED, luminaire 15 watt with all accessories internally pre-wired and including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core complete including taking down old unserviceable LED fitting complete all as specified and directed.
Supply and fix in repairs coral post top lantern fitting 25 Watt (for gate light), energy saving, environment friendly, long life aesthetically designed with symmetrical light distribution with complete accessories, including taking down old unserviceable post top lantern fitting complete all as specified and directed.
S&F in repair LED tube light complete fitting, surface mounted luminanaires, 1x9 watt, 240V, decorative ultra slimround/square profile LED lighting fixture with extruded polycarbonate body, environmental friendly, energy efficient ready to use pack with bi-pin holders, LED Lamps, connector block, etc complete with all accessories internally prewired and including connecting up with flexible copper conductor cable with suitable size complete including taking down old unserviceable Led fitting complete all as specified and directed.
S&F in repairs building security light fitting, 30 Watt made up of pressure die cast alluminium housing with high efficient LED as lighting source and pc over having top opening separate driver compartment with IP-66 Protection and impact resistance of IK-07 including suitable galvanized iron pipe, light grade, brackets 1 mtr length bent to shape to obtain required shape including clamps, nuts/bolts/washers etc connecting with suitable copper wire of size 23/0.0076 complete including all accesories ( bracket, clamps for fitting on wall) complete , including taking down of old unserviceable fitting complete all as specified and directed.
S&F in replacement flexible wire twin core copper conductor of size 23/0.0076 for ceiling fans, light fittings etc complete, including taking down old/unserviceable wire all as specified and directed.
Taking down of geyser of any capacity, any type from exiting position for descaling, removing its accessories removing the scale (white presipated) deposited in it, cleaning the inner tank properly and re-assembling the same and refixing to its existing location with testing for its proper functioning complete all as specified and directed.
Disconnecting, dismantling & taking up or down existing unserviceable geyser element of any description and in any position from geyser of 25 Ltrs/50 Ltrs capacity installed at site and supply and fixing new heating element of round/triangle for 1.5/2.0 KW, 230 volts to match with the existing system complete all as specified and directed.
Disconnecting, dismantling & taking up or down existing unserviceable geyser thermostat of any description and in any position from geyser of 25 Ltrs / 50 Ltrs capacity installed at site and supply and fixing new thermostat with setting range 30 ͦC to 80 ͦC suitable for 230 volts AC electric supply complete all as specified and directed.
Disconnecting, dismantling & taking up or down existing unserviceable geyser indication lamp of any description and in any position from geyser of 25 Ltrs / 50 Ltrs capacity installed at site and supply and fixing new indication lamp (set of two) complete all as specified and directed.
M&L for earthing complete with galvanised steel plate earth electrode 600mmX600mmX6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of size 32x6mm galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe ,medium grade, for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and directed.
Taking up or down 15 mm bore GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20 mm bore GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 25 mm bore GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Refixing of GI tubing, medium grade, 15 mm dia after cleaning of pipe with all fittings and fixed complete to walls and ceiling or laid on floors complete all as specified and directed.
Refixing of GI tubing, medium grade, 20 mm dia after cleaning of pipe with all fittings and fixed complete to walls and ceiling or laid on floors complete all as specified and directed.
Refixing of GI tubing, medium grade, 25 mm dia after cleaning of pipe with all fittings and fixed complete to walls and ceiling or laid on floors complete all as specified and directed.
S&F 15 mm GI tube, medium grade, with all necessary fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
S&F 20 mm GI tube, medium grade, with all necessary fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
S&F 25 mm GI tube, medium grade, with all necessary fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
Dismantling water tanks of capacity n.exc 500 litres and removing to store complete all as specied and directed
Dismantling water tanks of capacity exc 500 litres but nexc 1000 litres and removing to store complete all as specied and directed
Dismantling water tank capacity exc 1000 ltrs but nexc 2000 ltrs and removing to stores complete all as specified and directed
S&F 500 ltrs capacity rotational moulded, 3 layered, HDPE water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position all as specified in IS Code -12701-1996 including 20mm dia tank nipple complete all as specified and directed.
S&F 1000 ltrs capacity rotational moulded, 3 layered, HDPE water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in IS Code -12701-1996 including 20mm dia tank nipple complete all as specified and directed.
S&F 2000 ltrs capacity rotational moulded, 3 layered, HDPE water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in IS Code -12701-1996 including 20mm dia tank nipple complete all as specified and directed.
Taking down of existing float valve of any size from water storage tank and removal to store complete all as specified and directed.
S&F in repairs to 25 mm, PVC float valve high pressure of PTMT with epoxy coated aluminium rod & hight density plastic ball complete screwed for iron pipe or brass furred and fixed with fittings such as (socket, nipple, union) complete all as specified and directed.
S&F in repairs to 20 mm, PVC float valve high pressure of PTMT with epoxy coated aluminium rod & hight density plastic ball complete screwed for iron pipe or brass furred and fixed with fittings such as (socket, nipple, union) complete all as specified and directed.
S&F in repairs to 15 mm, PVC float valve high pressure of PTMT with epoxy coated aluminium rod & hight density plastic ball complete screwed for iron pipe or brass furred and fixed with fittings such as (socket, nipple, union) complete all as specified and directed.
Taking down of existing gate valve of any size and removal to store complete all as specified and directed.
S&F in repairs brass 25 mm, Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs brass 20 mm, Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs brass 15 mm, Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair to PVC water tank lid (Cover) for tank of 500 Ltr capacity as per existing make including locking arrangement with pad lock if required of Godrej size 50 mm (steel) comlete all as specified and directed.
S&F in repair to PVC water tank lid (Cover) for tank of 1000 Ltr capacity as per existing make including locking arrangement with pad lock of Godrej size 50 mm (steel) if required comlete all as specified and directed.
S&F in repairs to PVC water tank lid (Cover) for tank of 2000 Ltr capacity as per existing make including locking arrangement with pad lock of Godrej size 50 mm (steel) if required comlete all as specified and directed.
M&L for cleaning and degermination inside of RCC/PVC water storage tanks capacity not exceeding 500 Ltr of any description and in any position comprising following seven stage cleaning and sterilization of water tanks through bacteriological treatment by using Trebac G5/Inchlor-5/NB-10, Terbac G65/Inoxi-60/NB-69 and ultra violet rays complete all as specified and as directed. (a) First stage is to drain out the water by using exit valve or our own high capacity dewareing systems or any other suitable method approved by Engr-in-Charge. (b) Second stage is cleaning all the algae formation inside the tank by using Terbac G 10/ Inchlor-5/NB-10, a laboratory tested branded chemical of the company and scrubbing the walls of the tanks. (c) Third stage is fresh water cleaning by high speed jet pump with pressure 5 PSL. (d) Fourth stage first bacteria screening and Sterilization by using Terbac G5/Inchor-5/ NB-10, a Laboratory certified branded halogen compound, test certificate of Terbac G5/Inchor-5/ NB-10, from government laboratory mentioning suitability for sterilization. (e) Fifth stage is cleaning the floors of the water tank by heavy duty industrial vaccum cleaner. (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray Ejector covering 360 degree with in the tank and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agend TerbacG65/Inoxi-60/NB-69. Note:-(i) Test certificate of Terbac G65/Inoxi-60/NB-69 from Government Laboratory mentioning suitability for sterilization should be submitted to the office before using for Sterilization. (ii) Outlet pipe of OHT should be plugged before cleaning the OHT to avoid entering scale and the same shall be reconnected after cleaning the OHT and the quoted rate is deemed to include for this provision. (iii) Contractor will be responsible for rectification of complaints occurred during cleaning of tank i.e. No water in tank/ Over flow due to broken of float valve/blockage of Outlet lines due to silt and rectification cost will be deemed to be included in quoted rate.
All as per item No 267.00 here-in-before but capacity exceeding 500 Ltr but not exceeding 1000 ltrs
All as per item No 267.00 here-in-before, but capacity exceeding 1000 Ltr but not exceeding 2000 ltrs
Deduct Schedule of credit (calculation will be done off line) Rs. 67187.00
SHIV SHANKAR MISHRA (BID ID -3087831)
RAJPATI CONSTRUCTION (BID ID -3086379)
M/S Shanti Traders (BID ID -3087103)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .