Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.2 LAccepted-AOC H NO 309 REHARI COLONY JAMMU DISTT JAMMU J K 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹37.4 L+₹2.1 L (6.08%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹40.3 L+₹5.1 L (14.3%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹40.5 L+₹5.2 L (14.7%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹41.7 L+₹6.4 L (18.1%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
21 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN 913862 c/o 56 APO
Provn of certain sanctioned work at Naushera under AGE E/M of GE 862 EWS
2020_MES_380254_1
GER-44/2020-21
Open Tender
Civil Works
Item Rate
270 days
GE 862 EWS
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹96,000
Yes
31 Oct 2020
23 Sept 2020
23 Oct 2020
23 Sept 2020
21 Oct 2020
7 Oct 2020
60 days
Amount
Supply and errect in truly vertical position steel tubular swaged pole 09 mtr long with cast iron base plate 6mm thick, finial taper plug, bolts, nuts and screws as specified type 410 SP-31, including painting one under coat with anti corrosive primer and two coats of aluminium paint and in the botton above ground level alternative white & black strips of 30 cm width upto 1.5 mtr above ground level and marking pole No including taking down old unserviceable PCC poles of any size and removing from site and making good to disturbed surfaces complete all as specifed and directed. Note :- Earth work, excavation and PCC in foundation, coping etc shall be measured and paid separately under respective items.
Street light fitting LED 70/72 watt made up of grey powder coated pressure die cast aluminium housing having IP65 control gear and lens compartment. Fixture should have isolation in lense compartment and driver compartment and fitting must be top openable for easy maintenance and remain intact its IP protection forever after once it is open for repair. IP protection should be intacted for enhancing the overall efficiency of light. Fixture and driver should be of same make. Driver of the fixture must have enclosure and having vent from ends to prevent the driver from condensation effect and it should be BIS approved and R number should be mentioned on the top of the LED driver having voltage band of 110-300 Volts AC, THD <10% KV and also having surge protection inbuilt on driver is min 5KV and external SPD of 10KV outside the driver inside the fixture to prevent the fixture from non requirerd SUGRG. Driver should be equipped with over voltage short circuit and reverse polarity protections, driver must be constant current and constant voltage based (CVCT) fitting should having system efficiency of more than 100 lumens/watt. Fixture should be equipped with secondary lenses for better distribution of light. OEM must have its own manufacturing facility in regards to this OEM must produce the necessary documents of its own manufacturing along with the details of testing equipment and the respective Make : Crompton Cat Part No LSTP-72-CDLor techincally and commercially equivalent model of Havells/Wipro/Bajaj/C&S as approved by GE. Note :-1. Contractor shall obtain LM 79 and LM 80 test report (Electrical, photometry and chromaticity) (from third party NABL Lab only and inhouse NABL lab test will not be considered) for the light fitting from the manufacturer before supply of material and submit to the department. 2. A certificate of Guarantee shall be submitted by the contractor for period of 3 (three) years from the certified date of completion of work as a whole for repair/replacement of lamp and light fittings to GE. Performance guarantee amount @5% of quoted amount of LED lamp and light fittings shall be kept reserved for a period of three years. Accordingly ,performance guarantee amount shall be released after gaurantee period. 3. The manufacture LOGO shall be embossed into housing of luminaire. 4. Luminarie shall be provided with all parameters mentioned above. 5. Make of LED chip should be Cree, Nichia, Lumiled, Osram.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sq mm 2 core laid in trenches/ on poles/ under road crossing/ducts etc. complete all as specified and directed.
GI pipe 40mm bore light grade (ISI marked) with all fitting laid in trenches or on pole, crossing of roads, fixed on wall for protection of cable complete all as specified and directed.
Street light terminal box factory made powder coated with hinges and door with locking arrangement of size 30cm x 25cm x 15cm made out of 2 mm thick CRCA sheet, consisiting of aluminium bus bar of size 20 x 3mm, 63 Amp - 02 Nos for phase and neutral on porcelain based insulator and fixing clamps to poles and including MCB SP 06 Amps 240 Volts-01 No and providing multistranded copper conductor sheathed PVC insulated cable 2.5 sqmm from junction box to streel light fitting as connector for street light fitting complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and not exceeding 10sqm on plan for laying of cable, foundation of poles, stays etc and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m depth but not exceeding3m, 10sqm on plan for laying of cable, foundation of poles, stays etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, complete, all as specified and directed.
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified and directed.
Sand cushioning to underground cable, provided with a layer 8 cm before laying of cable and 15 cm after laying and stretching, jointing and testing the cable complete all as specified and as directed Note: Punned thickness of sand shall be measured and paid.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified and as directed.
PCC 1:4:8, type D-2 (using 40mm graded stone aggregate) in foundation, filling and mass concrete around poles etc. Complete all as specified and directed.
PCC 1:3:6, type C-2 (using 40mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed.
PCC 1:2:4 (normal mix) type B-1 using 20mm graded crushed stone aggregate as in coping of poles and the like complete including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
Supply and fixing street light bracket made out of 40mm bore GI tubing medium grade made to shape 1.2 mtr long bent to shape 120 degree and fixing with two numbers of MS clamp of 50mm x 6mm thick flat iron including , nuts, bolts, washer duly painted with synthetic aluminium paint two coats over a coat of red oxide primer complete all as specified and directed.
Timer switch 250 V single phase of 16/20 Amp rating with contactor fitted inside steel enclosure and making connection complete all as specified and directed.
Taking down unserviceable cable of any size complete all as specified and directed.
Taking down unserviceable steet light fitting of any type and watts including GI bracket from poles complete all as specified and directed.
GI pipe 25mm bore light grade (ISI marked) with all fitting laid in trenches or on pole, crossing of roads, fixed on wall for protection of cable complete all as specified and directed.
GI pipe 50mm bore light grade (ISI marked) with all fitting laid in trenches or on pole, crossing of roads, fixed on wall for protection of cable complete all as specified and directed.
Cross Arms, bracings, supports, clamps (including stay clamps, clamps for fixing GI tubes for passing through of cables) and back plates fabricated out of standard steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as directed and inclusive of providing two coats of aluminum paint over a coat of primer after preparation of steel surfaces including taking down old unserviceable cross arms complete all as specified and directed.
Stay assembly with 16mmm dia stay rod complete with accessories as shown in electrical plate No. 1 including taking down old unserviceable stay assembly complete all as specified and directed. Note :-loop type insulator, stay clamps, excavation and concrete shall be measured and paid for separately.
Dismantling house service brackets any type complete all as specified and directed.
Dismantling ACSR conductor on pole at any height complete all as specified and directed.
Dismantling earth wire or copper conductor, service feeder or distributor span complete all as specified and directed.
Dismantling insulator any type from poles complete all as specified and directed.
Taking down unserviceable wire any type complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sq mm 2 core, laid in trenches/ on poles/ under road crossing/ducts etc. complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core, laid in trenches/ on poles/ under road crossing/ducts etc. complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sq mm 3.5 core, laid in trenches/ on poles/ under road crossing/ducts etc. complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sq mm 3.5 core laid in trenches/ on poles/ under road crossing/ducts etc. complete all as specified and directed.
Fixing only serviceable street light fitting retreived from srl item No 18 on pole of any height complete all as specified and directed.
Supply and fixing street light bracket made out of 32mm bore GI tubing medium grade made to shape 1.2 mtr long bent to shape 120 degree and fixing with two numbers of MS clamp of 32mm x 3mm thick flat iron including , nuts, bolts, washer duly painted with synthetic aluminium paint two coats over a coat of red oxide primer complete all as specified and directed.
Fixing only serviceable street light bracket any size retrieved from srl item No 18 including providing new MS clamp of 32mm x 3mm thick flat iron, nuts, bolts etc complete all as specified and directed.
Aluminium conductor steel reinforced (ACSR) any description including stretching on overhead line on LT poles to required sag and binding with aluminium binding wire to insulators including jumpering the OH line jointing complete all as specified and directed.
Fixing only serviceable ACSR conductor retreived from srl item No. 24.00 on pole including binding with aluminium binding wire to insulator complete all as specified and directed.
GI earth steel earth wire 3.15 or 4mm dia as earth wire complete all as specified and directed.
Pin type, porcelain viterous white, brown or green insulator including one glavanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height, 65 mm dia for 1100 volts grade complete all as specified and directed.
Fixing only serviceable pin type insulator any type retreived from Srl item No. 26 including one galvanised mild steel spindle, two galvanised iron washer and one GI nuts complete all as specified and directed.
Shackle type, porcelain viterous white, brown or green insulator working pressure 1100 volts, 75mm height and 90mm dia including one glavanised mild steel straps, washer, insulator bolts complete all as specified and directed.
Fixing only serviceable shackle type insulator retreived from item No. 26 including one GI strap, washer, insulator bolts and nuts complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground, earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level, connected to and including 32X6mm thick galvanised iron strip by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete all as specified and directed. Note:-Earth strip and protection pipe upto board is included in the rate quoted.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground, earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level, connected to and including 4mm dia galvanised iron earth wire by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 15mm bore GI pipe light grade for protection of earth wire and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete all as specified and directed. Note:-Earth wire and protection pipe upto board is included in the rate quoted.
Taking up or down 20mm bore GI water tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 25mm bore GI water tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 40mm bore GI water tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 50mm bore GI water tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 80mm bore GI water tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 100mm bore GI water tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 150mm bore GI water tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Refixing old steel water tubing and connection in new or old position/laid in trenches including removing damaged portion, rethreading etc of 20mm bore GI pipe line including replacement of unserviceable fittings if any complete all as specified and directed.
Refixing old steel water tubing and connection in new or old position/laid in trenches including removing damaged portion, rethreading etc of 25mm bore GI pipe line including replacement of unserviceable fittings if any complete all as specified and directed.
Refixing old steel water tubing and connection in new or old position/laid in trenches including removing damaged portion, rethreading etc of 40mm bore GI pipe line including replacement of unserviceable fittings if any complete all as specified and directed.
Refixing old steel water tubing and connection in new or old position/laid in trenches including removing damaged portion, rethreading etc of 50mm bore GI pipe line including replacement of unserviceable fittings if any complete all as specified and directed .
Refixing old steel water tubing and connection in new or old position/laid in trenches including removing damaged portion, rethreading etc of 80mm bore GI pipe line including replacement of unserviceable fittings if any complete all as specified and directed .
Refixing old steel water tubing and connection in new or old position/laid in trenches including removing damaged portion, rethreading etc of 100mm bore GI pipe line including replacement of unserviceable fittings if any complete all as specified and directed .
Refixing old steel water tubing and connection in new or old position/laid in trenches including removing damaged portion, rethreading etc of 150mm bore GI pipe line including replacement of unserviceable fittings if any complete all as specified and directed .
20mm bore galvanized steel water tubing with screwed socket joints medium grade together with all fittings such as elbow, unions, nipples, tees, bends, short pieces, connectors, check-nuts, caps, plugs, diminishing pieces etc laid in tenches complete all as specified and directed.
25mm bore galvanized steel water tubing with screwed socket joints medium grade together with all fittings such as elbow, unions, nipples, tees, bends, short pieces, connectors, check-nuts, caps, plugs, diminishing pieces etc laid in tenches complete all as specified and directed.
40mm bore galvanized steel water tubing with screwed socket joints medium grade together with all fittings such as elbow, unions, nipples, tees, bends, short pieces, connectors, check-nuts, caps, plugs, diminishing pieces etc laid in tenches complete all as specified and directed.
50mm bore galvanized steel water tubing with screwed socket joints medium grade together with all fittings such as elbow, unions, nipples, tees, bends, short pieces, connectors, check-nuts, caps, plugs, diminishing pieces etc laid in tenches complete all as specified and directed.
80mm bore galvanized steel water tubing with screwed ends medium grade with sort pieces, diminishing pieces suitable for flange joints, laid in trenches/on support etc complete all as specified and directed. Note :- Flange including gasket, rings and nuts/bolts shall be measured and paid for separately.
100mm bore galvanized steel water tubing with screwed ends medium grade with sort pieces, diminishing pieces suitable for flange joints laid in trenches/on support etc complete all as specified and directed. Note :- Flange including gasket, rings and nuts/bolts shall be measured and paid for separately.
150mm bore galvanized steel water tubing with screwed ends medium grade with sort pieces, diminishing pieces suitable for flange joints laid in trenches/on support etc complete all as specified and directed. Note :- Flange including gasket, rings and nuts/bolts shall be measured and paid for separately.
Supply and fixing, in replacement, CI sluice valve 80 mm bore (ISI marked) with flanged and drilled ends complete iron wheel head with shut and open direction brass spindle class PN-1.6, conforming to IS-14846-2000 including high pressure rubber gaskets, insertion packing rings, jointing material, welding work if required, nuts, bolts and washer etc including testing after completion complete all as specified and directed.
Supply and fixing, in replacement, CI sluice valve 100 mm bore (ISI marked) with flanged and drilled ends complete iron wheel head with shut and open direction brass spindle class PN-1.6, conforming to IS-14846-2000 including high pressure rubber gaskets, insertion packing rings, jointing material, welding work if required, nuts, bolts and washer etc including testing after completion complete all as specified and directed.
Supply and fixing, in replacement, CI sluice valve 150 mm bore (ISI marked) with flanged and drilled ends complete iron wheel head with shut and open direction brass spindle class PN-1.6, conforming to IS-14846-2000 including high pressure rubber gaskets, insertion packing rings, jointing material, welding work if required, nuts, bolts and washer etc including testing after completion complete all as specified and directed.
Supply and fixing, in replacement, Gun metal, globe or gate valves (ISI marked), cast copper alloy, high pressure, with iron wheel head, handle, screwed both ends for GI pipe or for unions and fixed in, of size 20 mm bore complete all as specified and directed.
Supply and fixing, in replacement, Gun metal, globe or gate valves (ISI marked), cast copper alloy, high pressure, with iron wheel head, handle, screwed both ends for GI pipe or for unions and fixed in, of size 25 mm bore complete all as specified and directed.
Supply and fixing, in replacement, Gun metal, globe or gate valves (ISI marked), cast copper alloy, high pressure, with iron wheel head, handle, screwed both ends for GI pipe or for unions and fixed in, of size 40 mm bore complete all as specified and directed.
Supply and fixing, in replacement, Gun metal, globe or gate valves (ISI marked), cast copper alloy, high pressure, with iron wheel head, handle, screwed both ends for GI pipe or for unions and fixed in, of size 50 mm bore complete all as specified and directed.
Supply and fixing in replacement, MS flange internally threaded for 80mm bore GI tubing matching threads of pipe, 12mm thick with 8 drilled holes including 16mm dia 75mm long bolts and nuts with round plain washers complete all as specified and directed.
Supply and fixing in replacement, MS flange internally threaded for 100mm bore GI tubing matching threads of pipe 12mm thick with 8 drilled holes including 16mm dia 75mm long bolts and nuts with round plain washers complete all as specified and directed.
Supply and fixing in replacement, MS flange internally threaded for 150mm bore GI tubing matching threads of pipe 12mm thick with 8 drilled holes including 16mm dia 75mm long bolts and nuts with round plain washers complete all as specified and directed.
Mild steel framed work such as angle iron for supporting of ladder, MS sheets for covering man hole of RCC over head tanks, angle iron support of ventilation & tank covers including cutting/welding, bending, drilling holes, welding etc conforming to Fe 410-W (Gde-E-250) quality A complete all as specified and directed.
Brass spindle with check nut duly screwed, as required suitable for 80mm bore sluice valve complete all as specified and directed.
Brass spindle with check nut duly screwed, as required suitable for 100mm bore sluice valve complete all as specified and directed.
Brass spindle with check nut duly screwed, as required suitable for 150mm bore sluice valve complete all as specified and directed.
Mild steel bolts with hexagonal or square head one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut not exc 30cm long, diametre of neck exceeding 12mm but not exceeding 20mm complete all as specified and directed .
Construction of brick masonry valve pit in CM 1:6 (one brick thick wall) of internal dimension 90cm x 90cm x 90cm complete with MS angle iron frame work (angle iron size 50mm x 50mm x 6mm) and 3 mm thick MS black sheet top cover openable through hinges of suitable size including necessary earth work, PCC 1:4:8, type D-2 in foundation, plastering internally in CM 1:6 and externally flush pointed as work proceed, locking arrangement, applying two coats of black bituminous paint over a coat of red oxide zinc chrome primer to all iron surfaces complete all as specified and directed.
Supply and fixing in replacement, non return valve of size 150mm bore (ISI marked) with flanged and drilled ends complete class PN-1.6, conforming to IS-14846-2000 including high pressure rubber gaskets, insertion packing rings, jointing material, welding work if required, nuts, bolts and washer etc and testing complete all as specified and directed.
Supply, Installation and testing of Chemical Dosing system plunger type suitable to inject solution upto 50LPH comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP, 1440 RPM assembly with agitator in one motor with SS sweep blade duly FRP coated. FRP tank 150 Ltrs capacity complete unit mounted on heavy duty MS fabricated frame duly painted with two coats of synthetic enamel paint over a coat of primer complete with Chemical grade PVC NRV complete all as specified and directed.
Ph Test kit with coloured ample covered under BTB (range 6.0 to 7.0) or phenol red (range 6.8 to 8.4) with necessary fitments and 100 ml testing solution in Rexene finished box. Complete all as specified and directed.
Chlorine test kit with coloured ample complete with all testing fitments and OT solution in Rexene finished box. Complete all as specified and directed.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
Sheet metal enclosure triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 20 Amp complete all as specified and directed .
Wiring for circuit/submain wiring alongwith earth wire with FR PVC insulated copper conductor multistrand, single core cable in surface/ recessed as required of size 4x2.5 sqmm + 2x 1.5 sqmm earth wire drawing in and including 25mm bore PVC (ISI marked) conduit complete all as specified and directed.
Supply, installation and testing of air cooled split unit air conditioner electric driven (single phase), copper kit for cooling and heating type of capacity 4500 K cal per hour 1.5 Ton, 3/5 star rating with remote control, wall mounted with suitable arrangement including all piping etc. complete all as specified and directed. Make :- LG/Voltas/Blue star/Samsung.
Voltage Stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 to 260 V with output voltage stabilized at 230 volts with accuracy ± 2.5% 50 Hz of capacity 5 KVA complete all as specifed and directed.
Sheet metal enclosure single pole and neutral with two pin and earth plug and socket with one single pole MCB 20 amp complete all as specified and directed.
Voltage Stabilizer for automatic operation, three phase naturally oil cooled indoor, copper wound, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 1% to ± 2.5% and speed of correction 8 Volts per second and by pass arrangement of capacity 20 KVA including disconnecting & connecting all input and out put cable with provn of lugs/thimble and including 1st fill of oil and testing complete all as specifed and directed.
Cutting existing steel tubing 15mm for alterations or additions (Each cut measured) complete all as specified and directed.
Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces, single branch, "Y" junction, double branch cross (all sockets or socket and spigot) collars, caps and plugs upto 150mm bore complete all as specified and directed.
15mm bore galvanized steel water tubing with screwed and socket joints medium grade together with all fittings such as elbow, unions, nipples, tees, bends, short pieces, connectors, check-nuts, caps, plugs, diminishing pieces etc fixed to wall or ceiling or laid under floors including necessary cutting chaises and making good in CM 1:3 complete all as specified and directed.
15mm bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Storage water Heaters verticle type ( Geysers) of cap 25 Ltrs , 5 star rated as per BEE norms electrically operated suitable for 230 volts , 50 HZ AC supply system complete with porcelain/glass coated insulated heating element, copper inner tank, external thermostate including CP connections grouting of suitable nut, bolts etc complete all as specified and directed. Make Bajaj shakti /CG/ Venus/ Ditz.
Point wiring for one pin 15A socket outlet independent with 2.5 sqmm PVC insulated unsheathed FRLS copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed FRLS copper conductor single core cable (green color) as earth lead fixing on and inculding non metallic rigid PVC casing /non metallic rigid PVC conduit medium grade with all fitting (ISI maked ) controlled by one switch inculding CI/MS box of required size & as directed by Enrg-in-charge & 3mm thick plastic laminated sheet, making good the disturbed surfaces to match with the existing specification complete all as specified and directed.
Supply and fix air cooled split unit air conditioner electric driven, single phase of capacity of 1.5 TR, BEE 5 star rated including accessories required for fixing and civil works etc. and testing complete all as specified and directed. Make:- Samsung/Voltas/LG Godrej
Supply and fix room window type air conditioner electric driven (single phase), cooling capacity 3000 K Cal per hour (1.0 Ton) 5 star rated. Including mounting stand fabricated from MS angle of size 40x40x6 mm etc. complete all as specified and directed. Make:- Voltas/Samsung/LG/Godrej.
Sub main wiring complete with 2 runs of 4 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable along with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade multi stranded copper conductor as earth continuity conductor drawn through and including 25mm dia rigid PVC conduit and conduit accessories fixed on wall/floor/ceiling etc all as specified and as directed. Note: 03 runs of cable and one run of conduit shall be measured as one unit.
Single pointed air termination aluminium rod 12mm dia and 300mm long fixed on building roof with suitable arrangement complete all as specified and directed.
Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screws complete all as specified and directed.
PCC 1:2:4, type B-1 (using 20mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed.
Submersible pump set single phase of Cap 2 HP suitable for operating at 95 Mtr Head, 17 stages inlcuding connecting with column pipe, Provision of suitable size of supporting wire, column pipe holding clamps fabricated from 32x6 mm ms flat suitable size of nuts, bolts and reducer nipple to connect column pipe with submersible pump set making electric connection and lowering in borewell etc and testing complete all as specified and directed.
Submersible cable 3 core copper conductor of size 2.5 sqmm, 1100 Volts grade ISI marked complete all as specified and directed.
Direct online single phase submersible pump starter suitable for 2 HP motor fixed in factory made sheet enclosure including provision of Volts meter, Amps meter, indicating lamps, and suitable size of relay and capacitor etc complete all as specified and directed.
High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 heavy duty of size 25mm bore ISI marked, laid in trenches/fixed to wall or used for column pipe etc complete all as specified and directed.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
Jiwan Singh
Ankit Sagar
M/S NARAYAN CONSTRUCTION
M/S PARSHOTAM KUMAR GUPTA
M/S Jasbir Singh
Usha Engineering Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .