Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC | ₹20.9 L | L1 | Accepted-AOC AOC |
| 2 | L2₹21.8 L+₹83,009.20 (3.97%)Rejected-Finance | ₹21.8 L+₹83,009.20 (3.97%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹22.4 L+₹1.4 L (6.84%)Rejected-Finance | ₹22.4 L+₹1.4 L (6.84%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹25.1 L+₹4.2 L (19.8%)Rejected-Finance | ₹25.1 L+₹4.2 L (19.8%) | L4 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹23.1 L
EMD Value
₹46,300
Closing Date
18 Mar 2024, 6:00 pmClosed
Col S Pradeep CWE
HQ CWE Jammu
SPECIAL REPAIR/REPLACEMENT OF HT UNDERGROUND CABLE , BER TRANSFORMER, CONNECTED WORK AT BD BARI , RATNUCHAK MIL STN UNDER GE KALUCHAK
2024_MES_644278_1
CWEJP-69/2023-24
Open Tender
Entertainment/Musical Instruments
Item Rate
180 days
GE Kaluchak
As per tender documents
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹46,300
Yes
31 May 2024
27 Feb 2024
20 Mar 2024
27 Feb 2024
18 Mar 2024
6 Mar 2024
Amount
Dismantling and taking down existing unserviceable Gang operated switch complete including droout fuse set from RCC / Steel tubular, (Single/2Pole/3Pole/4Pole) pole structures complete all as specified and as directed.
Dismantling and taking down unserviceable ligheting arrestors complete all as specified and as directed.
Dismantling and taking down rusted / corroded Cross arms any shape and size from PCC/ Steel Tubular Poles including nut s, bolts clamps complete all as specified and as directed.
Dismantling and taking down demaged Pin / Disc type insulators 11 Kv any shape and size from PCC/Steel tubular poles complete all as specified and as directed.
Dismantling and taking down demaged GI Wire or cradles from the RCC/Steel Tubular poles complete all as specified and as directed.
Dismanteling and taking down demaged /rusted Overhead ACSR Conductor of any size from PCC/Steel and shifting to MES store yard complete all as specified and as directed.
XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core complete all as specified and as directed.
XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core complete all as specified and as directed.
XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) with stranded aluminium conductor 11000 volts Earth grade, cross sectional area 95 Sqmm 3 Core laid in trench /poles/on wall including taking out old unserviceable underground cable all as specified and as directed by the Engineer in charge
Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 50 to 95 Sqmm 3 core XLPE armoured aluminium conductor cable complete all as specified and as directed.
Cable jointing kit for 11 KV(Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 Sqmm complete all as specified and as directed .
Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of two coats of Aluminium Paint over a Coat primer, complete all as specified and as directed.
Switch air break, gang operated, triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, having current rating upto 400 Amps for working pressure 11000 Volts with drop out type fuse assembly complete all as specified and as directed
Lightening arrestors expulsion type suitable for HT 11KV complete with all fitting,transmission class having discharge capacity 65Kilo Amp complete all as specified and as directed
GI Pipe light grade 50 mm dia, ISI marked, of required length for protection of cables complete including necessary MS clamps, nuts, bolts and washers etc complete all as specified and as directed.
Galvanized iron tubing 80mm bore light grade with all fitting laid in trenches/wall/floor/pole for protection of cable including providing fixing clamps, bolts and nuts of suitable size complete all as specified and as directed
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for trench of cable/foundation of pole and stay etc and getting out in any type of soil soil complete all as specified and as directed.
Sand cushioning for protection of underground cable consolidated and compacted with clean dry sand complete all as specified and as directed.
Well burnt bricks, Sub class 'B' bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in any type soil complete all as specified and as directed.
Removing excavated material to a distance not exc 50 mtr and depositing where directed at level not exc 1.5 mtr above the starting point all as specified and as directed.
Supply, installation, testing and comissioning of step down copper wound transformer 11 KV/433 Volts, 3 phase 50 Hz 100 KVA outdoor type, vector group Dyn11,Energy efficiency level 2, with off load tap changing arrangement on HT side to vary secondary voltage from +5% to -10% in step of 2.5% including suitable cable entry boxes both on HT side to receive 95 Sqmm 3 core XLPE cable and on low voltage side to accomodate XLPE cable of suitable size complete in all respect with standard accessories and fitment confirming to IS:1180 part I 2014( and with latest ammendments). Primary side Delta and secondary side Star. The sailent feature of transformer shall be as follows:- (a) Transformer shall be oil immerse, naturally self cooled copper wound,winding core type MS radiator cooled tank complete with first fill of transformer oil plus 5% spare oil as per IS:335 of 1980 with cooling system.The temperature of oil shall not rise more than 50 degree centigrade to amient temp and 55 degree centigrade of winding(b) Transformer shall be provided with the followings:- (i) Rating and diagram plate. (ii) Earthing terminals 2 Nos. (iii) Lifting lugs. (iv) Thermometer pocket. (v) Air release hole with plug. (vi) Tap changer with locking provision. (vii) Oil temperature indicator. (viii) Bidirectional Roller (ix) Silicagel Breather
Supply install, test and commissioning LT Feeder Pillar / Panel board cubical type indoor Confirming to IS 8623 Part 1 1993, free floor standing / wall mounting factory fabricated made out of 3.15 mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming and outgoing ACB, Outgoing MCCB, MCB and TPN Aluminum bus bars of rating not less 1.5 times the rated cap of incomer Outgoing MCCB / ACB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar . The incoming as well as outgoing Outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves. The cubicle shall have a bottom channel of size as designed by the manufacturer . A detachable predrilled gland plateof thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air.3 mm XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP65 degree of protection , complete as specified and consisting the following switchgears and accessories:
Bus bar electrolytic grade aluminum strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 300 amps complete all as specified and as directed.
Main incoming MCCB four pole 415 V AC, current rating 200 amps, breaking cap 36 KA at 415 volts - 01 Nos complete all as specified and as directed.
Outgoing MCCB four pole 415 V AC, current rating 160 amps,breaking cap 25 KA at 415 V AC = 02Nos complete all as specified and as directed.
MCB TPN 4P-100 Amps 10 KA (01 for Outgoing + 01 Standby) complete all as specified and as directed.
On load Change Over 160 A, 415 Volt - 01 Nos complete all as specified and as directed.
LED indicator (R,Y,B) of suitable capacity with complete all as specified and as directed.
Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron complete all as specified and as directed.
Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 400/5 amps, 15 VA accuracy class - 1 complete all as specified and as directed.
Installing,commissioning ,testing,earth work PCC etc.complete all as specified and as directed.
Earthing with galvanised mild steel earth plate electrode of size 600x600x6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or GI Strip 32x6 mm by means of nut, bolt, check nuts and washer of galvanised ironl including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 7.5 m length fo drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing complete all as specified and as directed.
Earthing complete with copper earth plate electrode 60cm x 60cm x 3.15 mm thick buried directly in ground ( Earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected and including copper strip 20 mm x 3mm (upto the body of equipment) by means of Brazing,GI bolts , nuts, check nuts and washers earth plates surrounded by packed layers of coal dust earth plate surrounded by packed layers of coal dust and common salt 15 cm thick all around top and bottom and watering pipe 20 mm bore of GI pipe ,light grade all as shown in Electrical plate No 5 of SSR part –I testing on completion including PCC (1:2: 4) pit cover and PCC chamber in PCC (1:3 :6)type C-1 using 20mm graded crushed stone aggregate including excavation and earth work, disposal of surplus spoil to a distance not exc 50 m complete all as specified and as directed.
Construction of platform of size 3000mmx2500mmx1200mm for installation of transformer with brick steps on one side, chain link fencing around transformer, fencing should have hinged door and locking arrangements complete all as specified and as directed.
Dn construction and co
Sarbat Construction Co
M/S JIWAN SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .