| 1 | L1₹28.9 LAccepted-Finance | L1 | Accepted-Finance OK | |
| 2 | L2₹33.0 L+₹4.1 L (14.2%)Accepted-Finance | L2 | Accepted-Finance OK | |
| 3 | L3₹36.4 L+₹7.5 L (25.9%)Accepted-Finance 1 6 620 CHAITANYAPURI INDRA NAGAR DILSUKHNAGAR HYDERABAD TELANGANA 500060 UDYAM TS 09 0007870 37AAEPO0535A1Z8 B 36AAEPO0535A1ZA R MSME STATUS AS VERIFIED | RANGA REDDY | TELANGANA | 500060 | L3 | Accepted-Finance OK | |
| 4 | L4₹36.6 L+₹7.7 L (26.8%)Accepted-Finance FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L4 | Accepted-Finance OK | |
| 5 | L5₹36.7 L+₹7.8 L (27.0%)Accepted-Finance | L5 | Accepted-Finance OK |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
28 Feb 2024, 6:00 pmClosed
GE Utility Secunderabad
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIR RENEWAL OF STREET LIGHT
2024_MES_640425_1
GE(U)/SEC/TOKEN/67 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹90,000
Yes
11 Mar 2024
2 Feb 2024
6 Mar 2024
2 Feb 2024
28 Feb 2024
16 Feb 2024
Amount
M&L for attending, repair and rectification of external LT electric supply complaints on up to 1100 Volts grade, over head/underground system alongwith necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:-
Replacement of worn out jumpers, jointing and tightening with new ACSR conductor. Note:- Single phase/two wire or 3 phase/4 wire system will be considered as one job for payment purpose.
Disconnecting from over head conductor, cutting worn out portion of LT cables of any type and size, carry out repairs including taking out cables from under ground loop line and rejoining the same to restore electric supply. Note :- (i) LT Jointing Kits, Cable protection Pipe if required at site will be measured and paid separately. (ii) Quoted rate is deemed to be inclusive of cutting and removing the pole coping and inserting the cable alongwith protection pipes.
Taking down old unsv Street light / flood light fittings in any position of any capacity for Repair by replacement of unsv spares ( SPD / Driver / Mcpcb etc ) and re-fixing the same in existing location. Note:- Spares for repair of street light fittings will be measured and paid under respective items. Notes for Item Nos 1 to 4 :- (a) The contractor will be allotted complaints at MES complaint cell on daily basis on all working days and sufficient resources will be deployed by him/her for completion of day to day complaint within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consultation with Engr-in-Charge or JE E&M as detailed. (c) The contractor will make suitable arrangement for emergency complaints and will notify auth rep/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard. (d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare utilized as per inventory format given by AGE E/M, Secunderabd and the same shall be submitted to E/M No II store on daily basis.
M&L for ACSR conductor, steel reinforced for LT over head lines on poles including streching tightining of poles insulator with binding wire of suitable size with insulator/streching of ACSR conductor including disconnecting/taking out old existing unsv ACSR conductors complete all as specified and directed.
S&F Stay assembly comprising of 7/10 SWG galvanised MS stranded stay wire of required length, minimum tensile strength 70 Kg/mm (grade-2 quality) fixed to pole with and including FI clamps, bolts, nuts, washers, galvanised steel stay rod 16mm dia 180 cm long bow 400 x 14 mm nuts/bolts, washers, loop type insulator of size 65 x 90 mm vitreous, clearance dia of hole 16mm, stay plate of size 230 x 230 x 6 mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation and disposal of surplus soil, upto 50m including disconnecting/taking out old existing unsv stay assembly complete all as specified and directed.
S&F of Galvanised steel wire (GI) 4mm dia including disconnecting/taking out old existing unsv GI wire complete all as specified and directed.
M/L for cross arms, bracing, supports clamps and back plates fabricated from structural steel section incl nuts, bolts washers, welding, bending cold or hot drilling holes for bolts in any shapes or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including disconnecting/taking out old existing unsv cross arms complete all as specified and directed.
Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade.
Shackle type insulator, porcelain vitreous, white / brown / green, 1100 Volts grade, 75 mm height & 90 mm dia including galvanised mild steel strap of 31 x 3 mm, 12 mm dia insulator bolt, washers & nuts.
M&L in replacement Off-Load changeover switch (In sheet steel enclosure), AC 21 (Side Handle), 4 pole of capacity 200 Amps, 415 Volts, 50 Hz, Conforms to HSN Code : 8536 complete all as specified and directed.
Supply & Replace MCCB along with both side spreader link and nut bolts of appropriate size (Conforms to IEC:60947-II/IS:13947-II) in exisitng LT Panel box/Feeder Pillar boxes (KIOSK),in MCCB DBs of capacity 315-400 Amps, 4 Pole, 35 KA, 415 Volt including disconnecting/taking out existing old unserviceable/burned MCCB complete all as specified and directed.
All as per item No-12 here in before but of capacity 200 Amps, 4 pole, 36 KA
All as per item No-12 here in before but of capacity 125 Amps, 4 pole, 36 KA Note for Item 12 to 14 : Fixing of MCCB in existing panels including addition/alteration to sheet metal enclosure etc., and misc items required for fixing of MCCB's are deemed to be included in the quoted rates.
S&F MCCB factory made enclosure box with neutral link for TPN System made of sheet metal Powder coated Suitable for fixing at Pole including two set of clamps comprising with the following i) MCCB 63 Amps 16 KA TP .
S&F MCCB factory made enclosure box with neutral link for TPN System made of sheet metal Powder coated Suitable for fixing at Pole including two set of clamps comprising with the following i) MCCB 100 Amps 16 KA TP .
M&L in replacement for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area laid in trenches / duct or fixed to wall / passing through pipe on pole with suitable size cable glands, crimping type cable lugs for stranded aluminum conductor of following sizes complete all as specified and directed :-
4 core X 10 Sqmm
4 Core X 16 Sqmm
4 Core X 25 Sqmm
3.5 Core X 35 Sqmm
3.5 Core X 50 Sqmm
3.5 Core X 70 Sqmm
3.5 Core X 95 Sqmm
3.5 Core X 120 Sqmm
3.5 Core X 150 Sqmm
Taking out and Relaying of LT cable of size 10sq mm to 50 Sqmm 2/3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by ingr in charge. Note: ( Earth work , sand Cushioning, brick protection, LT Joints shall be measured and paid separately under Relevent Item)
Taking out and Relaying of LT cable of size 70 sq mm to 150 Sqmm 3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by ingr in charge. Note: ( Earth work , sand Cushioning, brick protection, LT Joints shall be measured and paid separately under Relevent Item)
Taking out and Relaying of LT cable of size 185 sq mm to 300 Sqmm 3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by ingr in charge. Note: ( Earth work , sand Cushioning, brick protection, LT Joints shall be measured and paid separately under Relevent Item)
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in hard / dense soil complete all as specified and directed.
All as per item No 21 here in before but depth above 1.5 m & below 3 m
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L filling riddled earth in trenches for cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning down shall be measured for payment.
Supply and Lay reinforced precast concrete cable cover LV, Type I,flat, size 250x150x40 mm complete all as specified and directed.
M&L brick protection with common burnt brick sub class ‘B’ of size 230x115x75mm for cable protection complete all as directed by Engr-in-charge.
Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminum paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
M&L for PCC 1:3:6 type C1 using 20mm graded aggregate set in cement mortar 1:4 as in coping/pedestals of poles including necessary form work complete and applying two coats of white wash to exposed surface of coping/platform complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded aggregate as in foundation, filling and mass concrete for pole / stay / post etc complete all as specified and directed.
M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate for filling & foundation of pole & mass complete all as directed
M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole complete all as directed
M&L in replacement Pipe bracket for street light fitting made out of 40mm dia GI pipe, medium grade, tubing bend to shape, 1.5m long fixed to pole wall including provn of two sets of clamps made out of flat iron of size 40x6 mm including of provn of bolts, nuts and washers complete all as specified and directed.
M&L in replacementcable junction box thermoplastic body IP 66 , size 225mmx295mmx122mm suitable for helogen free and weather proof for out door installation with metric knockout for cable entry suitable for cable size 16-35 sqmm including clamp, lugs,cable terminal & 6-10 amps MCB complete all as specified and directed.
Supply, lay, commissioning and testing of cable jointing Kit Heat shrinkable type for 1100 V grade cable for straight through joint with jointing material and accessories suitable for LTUG cable of size 16 to 50 Sqmm, 3.5 Core complete all as specified and directed.
All as per item No 36 here in before but suitable for aluminium conductor cable of size from 70 sqmm, 3.5 Core to 95 Sqmm, 3.5 Core
All as per item No 36 here in before but suitable for aluminium conductor cable of size from 120 sqmm, 3.5 Core to 185 Sqmm, 3.5 Core
Supply, lay, commissioning and testing of cable jointing Kit for 1100 V grade cable for outdoor End termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 16 to 50 Sqmm, complete all as specified and directed.
All as per item No 39 above but suitable for aluminium conductor cable of size from 70 sqmm, 3.5 Core to 95 Sqmm, 3.5 Core
All as per item No 39 above but suitable for aluminium conductor cable of size from 120 sqmm, 3.5 Core to 150 Sqmm, 3.5 Core
All as per item No 39 above but suitable for aluminium conductor cable of size from 185 sqmm, 3.5 Core to 240 Sqmm, 3.5 Core
S&F in replacement including connecting and testing energy saving, environmental friendly long life Varsatile pressure die cast aluminium alloy for housing (heat sink) with IP66 protection road way light fitting with high power LED as light source of capacity 90 watts with suitable driver and cable gland for maintaining ingress protection with Epoxy powder coated siemens grey finish after phosphochromate treatment, Tempered protective toughened glass,thermal shock and impact resistant fixed to the housing with SS screws , High efficiency long life LED chip in modules with lumen efficacy of >140 lm/W with PC lens and system lumen 6000. Powered by Built-in electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection. CCT 5700, CRI>70, THD<10%, PF>.95, IP66, .Life class of 50,000 hrs @ L70, Operating Temperature:-10 TO +50 DEG.C; Input Supply Voltage Range:140-270 V, Frequency : 50-60 HZ, Driver safety requirement standards :IS 15885-2-13 complete.
All as per item No-43 here in before but 100 watts.
S&Fin replacement LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting, with high power LED as light source of capacity 120 watts with suitable drivers etc and connecting with 4.0 Sqmm aluminium conductor PVC insulated twin core weather proof cable etc, fixing to wall/pole complete all as specified and directed. Note for Item 45 to 46: (i) Contractor has to produce LM-79/LM-80 certificate alonwith purchase vouchers and Guarantee certificate from Manufacturer. (ii) Surge protection of the driver should be 10 KV excluding inbuit SPD
All as per item No-45 here in before but 100 watts.
Supply and fixing lantren of dia 60 CM for fixing of flood light, cap type to be fixed on the top of 9 m SP-31 Steel pole , made of MS pip medium grade dia greater than the top dia of the pole of length 0.35 M supported by MS flat iron of size 50X6 mm 8 nos including two coat of aliminium painting over a coat of redoxide primer complete all as directed
Supply only LED Driver of similer wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 60 watts LEDstreet light fittings of any make complete all as specified and directed.
Supply only LED Driver of similer wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 70/72 watts LEDstreet light fittings of any make complete all as specified and directed.
Supply only LED Driver of similer wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 90 watts LEDstreet light fittings of any make complete all as specified and directed.
Supply only LED Driver of similer wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 100/110/120 watts LEDstreet light fittings of any make complete all as specified and directed.
Supply only LED Driver of similer wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 100 watts LED flood light fittings of any make complete all as specified and directed.
Supply only LED Driver of similer wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 120 watts LED flood light fittings of any make complete all as specified and directed.
Supply only LED Driver of similer wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 150 watts LED flood light fittings of any make complete all as specified and directed.
Supply only LED Driver of similer wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 200 watts LED flood light fittings of any make complete all as specified and directed.
Supply & lay heavy duty PVC insulated multi stranded Aluminum conductor 3 core of size 4 Sqmm, 230 volts, 50 HZ complete all as specified and directed.
Supply & lay heavy duty PVC insulated multi stranded Aluminum conductor twin core of size 6.0 Sqmm, 230 volts, 50 HZ complete all as specified and directed.
Supply & lay heavy duty PVC insulated multi stranded Aluminum conductor twin core of size 10.0 Sqmm, 230 volts, 50 HZ complete all as specified and directed.
Supply and laying GI tubing light grade of size 40 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm.
Supply & lay Galvanised Iron tubing 50mm bore, light grade in protection of cable at road crossing/hard standing/pole protection fixed with MS clamps of size 40 X 4 mm, nut bolts and washer as per site requirement including taking down old unserviceable pipes complete all as specified and directed.
All as per item No 61 above but GI tubing 80 mm bore.
M&L cutting of road/hard standing upto a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable/protection pipe line making good the disturbed portion so as to match existing finishing with PCC 1:2:4 type B1/cement mortar in CM (1:2) complete all as specified and directed
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Crystalline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg Backfill compound to provide maximum contact between the electrode and Back Fill Compound.connected to earthing test point including excavation, earth work, PCC pit, RCC cover 50 mm thick, lifting rod and testing on completion, complete all as specified and directed. Make: ASHLOK/GRAVIN/TRUE POWER/JVM
S&F cable route indicator for LT UG cable of 1100 volts bolted with 25x5 mm flate iron member of height 0.60 mtrs and 80 mm CI plate embeded in PCC 1:3:6 type C2 of size 15x15x20 cm block complete all as specified
M&L for repairing/Servcing of automatic operation of highmast lanten including all arrangements required including crane and replacement of all unserviceable spares of highmast lighting system of height 12 m to 16 meter . Quoted rates deemed to be inclusive of the following:- (i) crane as required for taking down of high mast pole including light without any damage to the mast, lantern and lights etc and refixing the same after repairing of the all problem on the same position (ii) Necessary disconnection and reconnection of electrical connection. (iii) Replacement of all unserviceable spare like High mast head, high mast ring , stainless steel wire, clamp, winch, transition plate, service door , Hook ring, nose plate, cabinet, gear, reel, transmission belt etc including servicing of gear box , filling of gear oil, greasing etc complete (quoted rates deemed to be inclusive of all spares required for proper functioning of lantern system except stainless steel wire, High mast head, high mast ring etc.
All as per item No 65 here in before but for highmast system above 16.5 meter and upto 25 meter
Supply only steel wire rope 6mm dia (7/19 construction) suitable for highmast system including u bolt complete all as directed
Taking down, transport to workshop , Re-winding of electric motor 3 phase installed at highmast pole of capacity 2.2/3 HP and refixing of the same including necessary arrangement complete all as directed
Repair/maintenance, excluding major spares but including regualr maintenance of the Automatic Power factor correction panel capacity up to 200 KVARs and up 8 stages installed at various locations at DGQA area including carrying out complete maintenance/repairs as required of all the sub systems viz. based control panels, feeder pillar, APFC relay, Power capacitor bank, Power contactors, Control wiring, Monitoring CT, MCBs/MCCBs for isolation (with all the accessoires) any breakdown maintenance and replacement of unserviceable parts, refixing of old serviceable parts/new parts if any project completion and trouble shooting responsibility also lies with contractor including following provisions complete all as specified and directed. Notes:- (i) Rate quoted by tenderer is deemed to be inclusive of checking of system fortnightly, repavement of defective control wiring, small part such as Push button, lugs any auxilary contatct,auto selctor switch etc and necessary servicing repair by expert technician and register will be maintaned for the same. (ii) The scope of work includes the labour charges required for removing, repairing, refixing, carrying out electrical termination, capacitors bank, APFC relay, power contactor, contol CT, MCBs/MCCB and fixing/installing/testing and commissioning the complete system. (iii) capacitors bank, APFC relay, power contactor, control CT, MCBs/MCCB shall be measured and paid seperatly
Supply only power factor correction capacitor, 5 KVAR, heavy duty 440 volts 50 Hz complete including taking down old unserviceable capacitor complete all as specified and directed.
All as per item No 70 above but 10 KVAR Capacitor Bank
All as per item No 70 here-in-before but 20 KVAR Capacitor Bank
All as per item No 70 here-in-before but 25 KVAR Capacitor Bank
S&F APFC relay etaCON M series with auto-set function 5 stage including taking down old unserviceable one complete all as specified and directed.
All as per item No 74 here-in-before but APFC relay with auto-set function 7 stage
All as per item No 74 here-in-before but APFC relay with auto-set function 8 stage
Supply anfd fix locally available gate / garden light of best quality metal Silver / metal black Decorative Exterior of size not less than 300 mm X220 mm with and including LED bulb 9 watt suitable for outdoor installation and suitable for fixing in 40/50 mm dia GI pipe including necessary connections complete all as specified and directed including taking down old one .
Supply, fixing, connecting and testing post top light fitting in spherical shape polycarbonate PMMA clear diffuser and IP65 protection, new generation energy saving and environmental friendly long life aesthetically desinged aluminium decorative luminaires with high power LED as light source of capacity 1X35/40 watts, fixed to Pole/Wall in any position including taking down old existing street light fitting of any type and capacity complete all as specified and directed.
Supply and fix locally availablegate / garden light light best quality Black Color Steel Shade With Fiber Glass Outdoor Gate Lamp of size not less than 360 mm X250 mm with and including LED bulb 9 watt suitable for outdoor installation and suitable for fixing in 40/50 mm dia GI pipe including necessary connections complete all as specified and directed including taking down old one . ake Jhoomarwala model SKU: (PM-GT-10-BIG) / equivalent as approved by GE
Supply anfd fix locally available Acrylic globe light best quality clear with and including LED bulb 9 watt of 300 mm dia complete suitable for fixing in 40/50 mm dia GI pipe including necessary connections complete all as specified and directed including taking down old one .
Supply, fixing, connecting and testing decorative LED Bollard light with opal diffuser and aluminium reflector of 9/12 watt LED including nut, bolts, washers, clamps etc as in repair complete all as specified and directed.
Material and labour for Taking down UNSV LED Lights and removing Carbon from its connector joints incl replacement of Connecting wire with new PVC sheated weatherproof 3X single core cable for electrical connection and refixing the fitting after repair to its original/New location or as directed by engr-in-charge.(connecting wire will be measured and paid separately only)
Supply anfd fix locally available Acrylic globe light best quality clear with and including LED bulb 9 watt of 200 mm dia complete suitable for fixing in 40/50 mm dia GI pipe including necessary connections complete all as specified and directed including taking down old one .
M&L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc with 1 coats of aluminium paint including throughly cleaning the existing surface, writing of pole numbers in yellow circle 15 cm with black paint on poles. Painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos black and 2 Nos Yellow) from ground level, complete all as specified and directed.
M&L for Painting the existing LT PCC poles with 1 coats of synthetic enamle base paint including painting of cross arms, clamps, etc with one coat of aluminium paint and providing alternative band of 30 cm width (3 black and 2 yellow) from bottom of pole to 1.5 metres height , writing of pole numbers in yellow circle15 cm with black paint on poles complete all as specified and directed.
Dismentling of damage / broken coping of PCC/steel pole of any size and removing the debries from site complete all as specified and directed
Supply and fix on wall with necessary arrangements busbar chamber 100 amps 4 way 4 pole wall mounted IP -31 , made out of 1.6 mm thick CRCA sheet epoxy powdwer coated single layer operational voltage 440 Volt , Short circuit current capacity 25 KA for 1 Second including necessary cable connections complete all as specified and directed. Note: Quoted rates inclusive of necessary fixing arrangement and cable connections , cable glands as required for proper fixing / functioning of Bus Bar Chamber.
Supply and fix on wall with necessary arrangements busbar chamber 200 amps 4 way 4 pole wall mounted IP -31 , made out of 1.6 mm thick CRCA sheet epoxy powdwer coated single layer operational voltage 440 Volt , Short circuit current capacity 25 KA for 1 Second including necessary cable connections complete all as specified and directed. Note: Quoted rates inclusive of necessary fixing arrangement and cable connections , cable glands as required for proper fixing / functioning of Bus Bar Chamber.
Replacement of transformer/LT Panel Boards End covers with suitable size of MS Sheet of 2mm thick including drilling holes as per existing transformer/LT Panel end cover, painting with 1 coat of red oxide primer and two coats of synthetic enamel paint and fixing with suitable size of nuts and bolts, hinges complete complete all as specified.
M&L Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size Complete all as specified and as directed
All as above but of HT 25x20 cm size
M&L for replacement of broken earth pit made out of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, 20 mm thick and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia MS deformed bars @ 100 mm centre to centre both ways with hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site complete all as specified and directed.
M&L repair/maintenance of stay by tightening of stay wire after untying the conductor spans from the poles to make correct tensions and maintain verticality of poles, including re-jointing the conductors in position with new binding wire complete all as specified and directed.
S&F galvanised steel strip 32X6 mm with saddles and fixing screws on poreceling insulator/ spacer fixed at every 1 mtr length as lightening conductor on roof/wall of explosive building and joining the same with existing earth test point all as directed by Engr-in-Charge.
S&F LT line rigid PVC Spacers spiral type, two lines, Phase to phase distance 300 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm.
S&F LT line rigid PVC Spacers spiral type, three lines, Phase to phase distance 600 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm.
S&F LT line rigid PVC Spacers spiral type, four lines, Phase to phase distance 900 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm.
Supply only of aluminium cable lugs of following sizes :-
16 to 25 Sqmm Size
35 to 50 Sqmm Size
70 to 95 Sqmm Size
120 to 150 Sqmm Size
185 to 240 Sqmm Size.
Dismentling of damage / broken coping of PCC/steel pole of any size and removing the debries from site complete all as specified and directed
Dismantling LT steel tubuler pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009 and applying two coats of aluminium paint to pole surface complete all as directed by Engineer-in-Charge.
Material and Labour for drawing two runs of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 1.50 sq mm with one run of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 1.50 sq mm including 20mm dia PVC conduit of dia 20 mm medium gradeexclusive of boxes but inclusive of all tees, bends, elbow, reducers etc and fixing accessories such as couples, lock nuts, saddles, pipe hooks, clamps etc complete all as specified
Supply and lay PVC Insulated , PVC sheathed industrial HV round multicore flexible cable with copper conductor THREE core 2.5 sqmm including PVC conduit 20 mm dia medium grade and necessary bends, fittings and fixtures as required for connection of light fittings . ( uSED FOR GARDEN LIGHT CONNECTION, EXCAVATION , RETUNING FILLIING ETC WILL BE MEASURED AND PAID SEPARATELY.
S&F PVC insulated unsheathed/sheathed cable with stranded Aluminium conductor 1100 Volts grade, flat twin core service cable of size 4 Sqmm conforming to IS:694/1990 with latest amendments ISI including disconnecting/taking out existing unsv/damaged old service cable complete all as specified and directed. Make : Richa/havells or equivalent.
Supply and lay PVC Insulated , PVC sheathed industrial HV round multicore flexible cable with copper conductor THREE core 1.5 sqmm as required for connection of light fittings .
Supply, Installation, test and Commissioning factory fabricated, outdoor type, LT Busbar panel made out of 3.15 mm thick CRCA Sheet of suitable size Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level complete with internal connection with suitable size of cable ,cable lugs, and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified and comprising of the following :- (a) Aluminium bas bar of 300 Amps - 04 Nos in 3Phase and half neutral fashion , supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. (b) MCCB 100 amps, 415 volt,16 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar as IN COMING - 01 Nos
Excavation in post holes (or similar holes) each n exc 0.50 cum getting out In hard / dense soil returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm complete all as specified and directed
M&L for framed works in posts and struts in fencing including cutting tops to shape as directed drilling holes notching for wire etc flat iron fillets ( for securing wire mesh etc ) including all necessary drilling bolting or riveting etc and simlar work conforming to FE-290 Gde E-165 including dismantling of old fencing complete all as specified and directed.
S&F 3.15 mm dia chain link MS galvanised fencing wire and average size of mesh 100 mm X 100 mm including line wires to ant type of standard rails straining bolts etc including provision of binding with MS wire annealed not less than 0.9 mm dia complete all as specified and directed.
M&L for cleaning AND painting LT panel boards of any size thoroughly with necessary cleaning agent including scrapping up of old corroded paint dirt / rust carefully and applying two coats of synthetic enamel paint OVER A COAT OF RED OXIDE PRIMER COMPLETE all as specified and directed.
M&L for shingle filling in floors or pavings of gauge 20 mm to 40mm deposited spread and levelled in layers not exc 150 mm thick watered and rammed to true surface complete all as specified and directed
Trimming/pruning and removing of tree branches or any other foreign objects from HT/LT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way /4 way/6 way conductor system. Notes: (i) Insulators of any type, connectors and ACSR conductor of any size required at site will be measured and paid separately under relevant item of this schedule. (ii) The contractor is responsible for provision of Necessary T & P including crane and safety equipments to complete the job.
Cutting unaxious green growth and grass by manual labour or by machine at all 11 KV Electric Installation premises/around 2/4 Pole structure/along the boundary fencing and removing rubbish from the site of work complete all as specified and directed.
Srinivasa Consructions
DPS sales and services india
L and S ENTERPRISES
Haasith constructions
Mavee Syndicate
SUN LIGHT HOUSE
omsai thermax engineers
Srinivash Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .