Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC 67 A HAFIZALI BAHADUR KHAN MARG SURAJI COMPOUND BEHIND KHATAU MILL BYCULLA W MUMBAI 400011 BRITE INDUSTRIES 67 A HAFIZALI BAHADUR KHAN MARG SURYAJI COMPOUND BEHIND KHATAU MILL MUMBAI | MUMBAI | MAHARASHTRA | 400011 | L1 | Accepted-AOC LOWEST QUOTED BIDDER | |
| 2 | L2₹22.3 L+₹1.8 L (8.66%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 3 | L3₹23.2 L+₹2.7 L (13.2%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
Tender Value
₹24.5 L
EMD Value
₹50,000
Closing Date
3 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF SECUNDERABAD
CWE AF SECUNDERABAD BOWENPALLY POST SECUNDERABAD 500011
REPAIRS AND PERIODICAL MAINTENANCE OF CERTAIN CENTRAL TYPE AC PLANTS AT AFA HYDERABAD
2022_MES_504233_1
86665/E8
Open Tender
Civil Works
Item Rate
180 days
GE AFA HYDERABAD
AS PER NIT
9 documents required · 9 mandatory
₹500
GE AFA HYDERABAD
₹50,000
Yes
8 Mar 2022
28 Jan 2022
5 Mar 2022
28 Jan 2022
3 Mar 2022
17 Feb 2022
28 Jan 2022 - 12 Feb 2022
60 days
Amount
M&L for Servicing / Overhauling to Central type AC Plant for overhauling and servicing whole plant (ie chiller units), blowing out the dust, rectifying the minor problems, checking of interlock of safety/ control device, checking of all electrical connections / fuse in unit & panel, checking refrigerant/ water pipe lines, servicing of compressor unit, cleaning of plant, servicing of chiiler/condencer pumps, replacement gland packing in pumps, replacement of leakage water drain out pipe from pumps as per existing system, replacement of wornout insulation cover of chiller unit in the plant as per existing specifications of Central type AC plants complete all as specified and directed for the following capacities :-
(a) Air cooled, chilled water type 3 x 56 TR Capacity at Moolgavkar Hall
(b) Water cooled, chilled water type 3 x 37 TR Capacity at BTA Simulator II & III
(c) Air cooled, chilled water type 3 x 22.7 TR Capacity at PC 7 Simulator I
(d) Air cooled, chilled water type 3 x 24 TR Capacity at SD Simulator
(e) Air cooled, chilled water type 2 x 22 TR Capacity at WT, CRRW & 14 AFH
(f) VRF (Centralised Package Type) 1 x 60 TR Capacity at Link Trainer (Including casette type AC's)
M&L for de-scaling the shell tube condenser and chiller water line complete upto AHU by circulating diluted hydrochloric acid (HCL) at the appropriate ratio depend upon the scale deposits till removal of all scale inside the copper tubes & shell of the condenser by forced feed method, removal of end covers, brushing with the nylon brush, removal of all scale and degreasing with caustic soda, flushing out thoroghly, refixing the end covers with new gasket packing and nuts and bolts, connecting the inlet / outlet water connection, checking of water leakage, testing of Central type AC plants complete all as specified and directed by for the following capacities :- Note :- All equipments such as pump set, pipes & chemical has to be arranged by contractor . No extra charge has to be paid by the department on that account.
(a) Water cooled, chilled water type 3 x 37 TR Capacity at BTA Simulator II & III
M&L for de-scaling the chiller shell with water line complete upto AHU by circulating diluted hydrochloric acid (HCL) at the appropriate ratio depend upon the scale deposits till removal of all scale inside the copper tubes & shell of the condenser by forced feed method, removal of end covers, brushing with the nylon brush, removal of all scale and degreasing with caustic soda, flushing out thoroghly, refixing the end covers with new gasket packing and nuts and bolts, connecting the inlet/outlet water connection, checking of water leakage, testing of Central type AC plants complete all as specified and as directed for the following capacities :- Note :- All equipments such as pump set, pipes & chemical has to be arranged by contractor . No extra charge has to be paid by the department on that account.
(a) Air cooled, chilled water type 3 x 22.7 TR Capacity at PC 7 Simulator I
(b) Air cooled, chilled water type 3 x 24 TR Capacity at SD Simulator
(c) Air cooled, chilled water type 2 x 22 TR Capacity at WT, CRRW & 14 AFH
M&L for leak testing of the total refrigerant system of AC plants by pumping down the refrigerant to cylinder (evacuation of gas from the sysytem into the empty cylinders), flushing out the entire system arrest all leakages by replacing the damaged flare nuts, teflon washers, brazing, gaskets, o rings etc and leak test by supply and charging with Nitrogen gas (N-2) under constant pressure of 250 - 350 PSI , watching the pressure for 24 Hrs for confirmation, flushing out the system vacuumising and recharge/charge the required qty of refrigerant and lubricant testing and commissioning the system complete all as specified and as directed for the following capacity compressor of AC plants :- . (Note :- Refrigerant & compressor oil shall be measured and paid separately for maintained the level under respective items)
(a) 11 to 13 TR Compressor
(b) 20 TR Compressor
M&L for repairs and servicing of FRP Cooling Towers of BTA AC plant 3 x 37 TR capacity by disconnecting all connection, thorough cleaning of FRP casing header, PVC fins, strengthening the MS structural supports, replacement of all old PVC fins of suitable size ,rusted nuts, bolts, washers and greasing/oiling of fan motor and fan bushes/bearing, checking fan assembly, replacement of existing perished filter screen of out-let connections, arresting leakage for all joints by applying FRP compound and including painting of complete tower inner/outer body and steel structure with plinth as per existing colour complete all as directed by EIC.
M&L for servicing the Air Handling Units dismantling sheet metal parts, blowing out the dust, chemical cleaning by spraying the organic based scale removing agent at the appropriate ratio till removal of complete dust & scale deposits in the fins area of cooling coil, flushing through for proper air flow across the coil, checking of the electrical connection, cleaning of air filters, greasing of blower motor, repair of blower shaft, replacement of un serviceable bearings, tightening of V-belts, clearing of water drain lines, renewal of rusted sheet metal screws and testing the unit complete all as specified and as directed for the following capacity AHU :-
(a) AHU Capacity 22400 CFM (02 Nos) at Moolgavkar Hall
(b) AHU Capacity 32 TR,19 TR, 7 TR,4 TR (each one) & 6 TR (02 Nos) Capacity at BTA Simulator II & III
(c) AHU Capacity 22 TR (02 Nos) at PC 7 Simulator I
(d) AHU Capacity 15000 CFM at SD Simulator
(e) AHU 11806 CFM at WT, CRRW & 14 AFH
Attending urgent complaints on requirement basis as specified by Engineer-in-Charge for Central type AC plant of various capacity and their electrical connections upto DBs installed in side of Tech area and Domestic area at AFA and rectifying the defects and making machine satisfactory functional from 0900 Hrs to 1700 Hrs ( for 08 HRS Only) excluding Sunday and Holidays complete all as directed.
Note :- (i) Any defective part which are required to be replased shall be measured and paid seperatly under relevent items as per direction.
(ii) Attending complaint in urgent basis as a professional service provider on requirement basis (for 8 Hrs only) as per direction of Engineer- in - Charge.
(iii) All Tools & Plants, labiour required for repair work as per nature of repair shall be provided/arranged by the contractor at his own arrangement.
(iv) All services to be provided with in 24 hours of reporting of complaints. Penalty charges for non attending complaints with in 24 hrs shall be double the quoted rate per complaint per day. Note :- A separate Job record will be kept as the record showing the number of Job attended during the contract period.
M&L for preparation of surfaces by scrapping and removing rusted portion with wire brush and applying one coat of zink chrome metal primer and applying two coats of synthetic enamel paint by spray method for complete AC plant i'e compressor units, chiller unit, condenser unit, AHU, inlet/outlet pipe lines with connected valve, chiller & condenser pumps set, channels, and LT panel board including lettering & numbering and one coat of white wash/colour wash to chiller pipe line and plinth of plant as per site requirement complete colour code as per direction complete all as directed by Engineer-in-Charge for the following AC plants :-
(a) Air cooled, chilled water type 3 x 56 TR Capacity at Moolgavkar Hall
(b) Water cooled, chilled water type 3 x 37 TR Capacity at BTA Simulator II & III
(c) Air cooled, chilled water type 3 x 22.7 TR Capacity at PC 7 Simulator I
(d) Air cooled, chilled water type 3 x 24 TR Capacity at SD Simulator
(e) Air cooled, chilled water type 2 x 22 TR Capacity at WT, CRRW & 14 AFH
M&L for taking down unserviceable hermetically sealed compressor after disconnecting the suction/delivery lines and Supply & fixing hermetically sealed compressor of following capacities as per existing make, model & specification, including pressure testing, vacuumising and charging of refrigerant, testing and commissioning all as directed Make :- Copeland / Danfoss / kirloskar / Blue Star / Voltas (and as per site requirement) Note :- Refrigerant shall be measured and paid separately under respective items.
(a) 20 TR Capacity
(b) 13 TR Capacity
(c) 12 TR Capacity
(d) 11 TR Capacity
M&L for taking down unserviceable liquid line filter drier and S&F new filter drier as per existing same make & specification and suitable size to fixing with existing refrigerant line for 11 TR to 13 TR capacity compressor of AC Plant complete all as specified and as directed.
M&L for taking down unserviceable liquid line filter drier and S&F new filter drier as per existing same make and specifications and suitable size to fixing with existing refrigerant line for 20 TR capacity compressor of AC Plant complete all as specified and as directed.
Material & labour for repairs and overhauling of mono block pump sets (chiller/condenser pump sets) of following sizes by disconnecting and taking out from position, dismantling and re-building the shaft at worn out places, machining to it’s original size, replacement of worn out bush / ball bearings, re-conditioning the impeller and gland bushings, replacement of packing, stud bolts etc., applying insulating varnish on the stator and rotor winding for improving ohmic/insulation value, drying up and re-assembling the pump set, installing at it’s original location, connecting up all connections, testing and commissioning complete all as specified and as directed for the following capacities :-
(a) upto 3.0 HP
(b) 5.0 to 7.5 HP
Material and labour for taking out motor from the base and re-winding of burnt 415 V, 3 phase motors of following capacities with new super enameled copper wire of same gauge and same number of turns as existing after thorough cleaning of stator body and rotor, applying insulating varnish, drying up by heating for improving insulation resistance, re-assembling the motor by replacing both end bearings, re-installing at it’s original position, connecting up, testing and commissioning complete all as specified and as directed for the fallowing capacity motors :-
(a) upto 3.0 HP
(b) 5.0 to 7.5 HP
Supply and fix water pressure gauge for suction/discharge lines and water lines of round type of following ranges for AC plants including taking down old unserviceable pressure gauge complete all as specified as directed for the following :- Make :- FIEBIG / H- GURU
(a) 0-150 PSI, size 2'' dial for refrigerant line
(b) 0-300 PSI, size 2'' dial for refrigerant line
(c) 0-12 Kg./cm2, size 4" dial for water line
Removing the unserviceable thermostat switch and S&F Thermostat Switch of range -5 to +25 degree centigrade for AC Plant complete all as specified and as directed.
Removing the unserviceable thermostatic expansion valve and S&F Thermostatic Expansion Valve suitable for following capacities compressor including cutting and brazing complete all as specified and directed by Engr-in-Charge. Make :- SPORLAN / ALCO / DANFOSS
(a) 11-12 TR Capacity
(b) 13 TR Capacity
(c) 20 TR Capacity
Removing the unserviceable hand shut off valve (brass) from the refrigerant line after cutting the liquid line and S&F hand shut off (brass) valve of following sizes with necessary welding / brazing etc complete all as specified and as directed. Make :- FREON / MAHAVIR or equivelant
Material and labour for taking out the defective high / low pressure cut-outs of any range and model and S&F new high / low pressure cut-outs of following sizes connecting the pressure lines / controll wiring, leak testing and commissioning complete all as specified and as directed for the following :- Make :- INDFOSS / DANFOSS
a) HP / LP pressure cut-out MP-15
b) Water pressure cut-out IPS-70
c) Low pressure cut-out MP-1
d) High pressure cut-out MP-5
e) Oil pressure cut-out MP-55
S&F Digital type temperature and humidity sensors metering sytem wall mounted suitable for Central AC plant AHU Room including fixing on wall & electrical connections and removing the existing unserviceable ones complete all as specified and as directed. Make: SYSTEM SENCOR / UNITECH / IRCON
M&L for repair / servicing programable microprocessor based control panel with touch screen display including repair all equipment protection devices etc. & replace wornout u/s single/three phase controllers, contractors, fuses, internal wiring as per existing same model & specification and suitable size to chiller unit central type AC Plant of 22 TR to 56 TR capacity, complete all as specified and as directed.
S&F in replacement programable microprocessor based control panel with touch screen display alongwith mother board, single phase controllers, contractors, fuse as per existing same model/make & specification, controlling suitable for following capacities chiller unit to AC plant, all as specified and directed by the Engr-in-charge. Make :- Suitable for Voltas / Bluestar AC plant (as per OEM recomended & site requirement)
(a) 56 TR capacity chiller unit
(b) 37 TR capacity chiller unit
(c) 22 TR capacity chiller unit
Removal of the unserviceable air filters and S&F new air filters as per existing type of the following sizes for the AHU complete all as specified and as directed for the following :-
(a) 600 mm x 600 mm x 45 mm with 10 Micron
(b) 600 mm x 300 mm x 45 mm with 10 Micron
M&L for taking down unserviceable blower motor V Belt and S&F blower motor V Belt as per existing model & specification and suitable size to fixing with existing system for AHU of central type AC Plants, complete all as specified and as directed.
M&L for taking down unserviceable blower motor V Belt Model No A28 and S&F blower motor V Belt Model No A 28 as per existing model & specification and suitable size to fixing with existing system for AHU of central type AC Plants, complete all as specified and as directed.
M&L for taking down unserviceable blower motor V Belt Model No SPA 1935 and S&F blower motor V Belt Model No SPA 1935 as per existing model & specification and suitable size to fixing with existing system for AHU of central type AC Plants, complete all as specified and as directed.
M&L for taking down unserviceable blower motor V Belt Model No B-100 and S&F blower motor V Belt Model No B-100 as per existing model & specification and suitable size to fixing with existing system for AHU of central type AC Plants, complete all as specified and as directed.
M&L for taking down unserviceable blower motor V Belt Model No 56/57/58 and S&F blower motor V Belt Model No 57/57/58 as per existing model & specification and suitable size to fixing with existing system for AHU of central type AC Plants complete all as specified and as directed.
M&L thermal insulation with aluminium faced nitrile rubber 12 mm thick for duct/AHU as per existing density and thermal conductivity including packing material for the AC plants complete all as specified and as directed. Make- Armaflex / Aeroflex / Thermobreak
Material and labour for Thermal insulation cover with aluminium cladding sheet for 80 & 60mm dia chiller pipe line complete all as specified and as directed.
Removing unserviceable PVC water tank from humidifier system of plant and S&F new Loft mounted water storage tank LOFT type of 100 Ltrs capacity suitable for existing humidifier system of central type AC Plants ,complete all as specified and as directed. Make:- Sintex / Polycon, Jaipur/ Rotex
M&L for taking down old u/s chilled water storage water tank and S&F new Rotational moulded polyethylene water storage tanks double layer (cylindrical vertical with closed top) hoisted of 500 ltrs capacity including connections, flot valve and PCC/plaster work for heat protection insulation to PVC chilled water tank as per existing same, complete all as specified and as directed. Make:- Sintex / Polycon, Jaipur / Rotex
M&L for rigid PVC conduit (medium grade) size 40 mm dia for pumps drain water out AC plant, laid on walls, ceiling, in floors with clamping/fixing mtrls complete all as specified and as directed.
Supply and filling / topping up / charging of Refrigerent gas R-22 for Central / Package type ACs complete all as specified and as directed.
Supply and filling / topping up / charging of Refrigerent gas R-407 for Central / Package type ACs complete all as specified and as directed.
Supply and filling /topping up / charging of Refrigerent gas R-410A for Central/Package type ACs complete all as specified and as directed.
S & F in replacement as per existing type MCCB 175 Amps ,415 volt ,36 KA Breaking capacity, thermal magnetic release 4 pole incl all termnials, fitting etc complete all as specified and as directed.
S & F in replacement as per existing type MCCB 100 Amps ,415 volt ,25 KA Breaking capacity, thermal magnetic release 4 pole incl all termnials, fitting etc complete all as specified and as directed.
S & F in replacement as per existing type MCCB 75 Amps ,415 volt ,25 KA Breaking capacity, thermal magnetic release 4 pole incl all termnials, fitting etc complete all as specified and as directed.
S & F in replacement as per existing type MCCB 63 Amps ,415 volt ,25 KA Breaking capacity, thermal magnetic release 4 pole incl all termnials, fitting etc complete all as specified and as directed.
S&F MCBs TPN 32/40 Amps 415V including all termnials, fitting etc. complete all as specified and as directed.
S&F MCBs SPN 6 to 40 Amps 415V including all termnials, fitting etc. complete all as specified and as directed.
S&F MCBs SP 6 to 40 Amps Amps 415V including all termnials, fitting etc complete all as specified and as directed.
S&F 3 Pole MCBs C Series 63 Amps 415V including all termnials, fitting etc. complete all as specified and as directed.
S&F 3 Pole MCBs C Series 40 Amps 415V including all termnials, fitting etc. complete all as specified and as directed.
S&F 3 Pole MCBs C Series 6 Amps 415V including all termnials, fitting etc. complete all as specified and as directed.
S&F in replacement for the following unserviceable spare parts for AC plants of any make and model complete all as specified and as directed for the following :-
(a) Contactor rated current AC 3 Ph, 9 Amps, coil voltage 415 V AC, 50Hz, capacity as per existing specification (Make :- C&S or equivalent in SIEMENS / L&T / BCH)
(b) Contactor rated current AC 3 Ph, 12 Amps, coil voltage 415 V AC, 50Hz, capacity as per existing specification (Make :- C&S or equivalent in SIEMENS / L&T / BCH)
(c) Contactor rated current AC 3 Ph, 16 Amps, coil voltage 415 volts AC, 50Hz, capacity as per existing specification (Make :- C&S or equivalent in SIEMENS / L&T /BCH)
(d) Contactor rated current AC 3 Ph, 22 Amps, coil voltage 415 volts AC, 50Hz, capacity as per existing specification (Make :- C&S or equivalent in SIEMENS/L&T/BCH)
(e) Over Load Relay of range 7 to 10 Amps (Make :- C&S or equivalent in SIEMENS/L&T/BCH)
(f) Over Load Relay of range 9 to 13 Amps (Make :- C&S or equivalent in SIEMENS/L&T/BCH)
(g) Over Load Relay of range 9 to 14 Amps (Make :- C&S or equivalent in SIEMENS/L&T/BCH)
(h) Over Load Relay of range 12 to 18 Amps (Make :- C&S or equivalent in SIEMENS/L&T/BCH)
(j) Over Load Relay of range 14 to 22 Amps (Make :- C&S or equivalent in SIEMENS/L&T/BCH)
(k) Over Load Relay of range 17 to 25 Amps (Make :- C&S or equivalent in SIEMENS /L&T / BCH)
(l) Control Relay of range 10-12 Amps DN22 (Make :- C&S or equivalent in SIEMENS / L&T / BCH)
(m) LED Indicator lamps of colors R / Y / B (Make : - C&S / SIEMENS / L&T)
(n) HRC fuse 2.5 to 10 Amps (Make :- C&S / SIEMENS / L&T)
(o) HRC fuse 16 to 32 Amps (Make :- C&S / SIEMENS / L&T)
(p) Push button with element for starter (Make : -C&S / SIEMENS / L&T)
(q) S&F in replacement PVC Connectors 35 Sqmm. (Make :- :Plaza / Sudhakar / Finolex)
(r) S&F in replacement Chiller Sensors suitable for Voltas Central Type AC Plant same as per at site
(s) S&F in replacement Chiller Sensors suitable for Blue Star Central type AC Plant same as per at site
(t) S&F in replacement Chiller Thermometer for Central Type AC Plant same as per at site
(u) S&F in replacement Condenser relief valve of Cap 350 PSI for Central Type AC Plant same as per at site
(v) S&F in replacement PCB Transformer 240 Volts for Central Type AC Plant same as per at site
M&L for PCC 1:3:6 type C- 1 mix using 20 mm graded stone aggregate as in platform, filling and mass concrete, for maintenance of plant area etc, complete all as specified and as directed .
M&L for Pre-cast cement concrete block masonry type C-1 PCC (1:3:6) using 20 mm graded stone aggregate with solid blocks, exc. 10 cm in width and setting in mortar 1:4 , complete, for foundations /platform / pedestal etc, complete all as specified and as directed .
M&L for rendering 10 mm thick in CM 1:6 on brick / concrete/ block masonery surfaces and rendering is to be finished fair complete all as specified and as directed .
SHANTI MARKETING AND SERVICES
K LAKSHMAN SINGH AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .