Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹21.8 L
EMD Value
₹44,000
Closing Date
14 Nov 2026, 6:00 pm5d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
CWE AF Trivandrum
HQ CWE AF TRIVANDRUM HQ SAC IAF Complex Akkulam Thruvikkal Post Trivandrum 11
REPAIR/OVERHAULING/SERVICING AND REPLACEMENT OF WORN-OUT UNSERVI-CEABLE SPARES TO COOLING APPLIANCES AND CONNECTED ACCESSORIES AT AF STN THANJAVUR.
2026_MES_795424_1
82708/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF THANJAVUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AF THANJAVUR
₹44,000
Yes
23 Oct 2026
23 Oct 2026
16 Nov 2026
23 Oct 2026
14 Nov 2026
7 Nov 2026
23 Oct 2026 - 31 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S&F in repairs MCB, Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA complete all as specified and as directed | 10 | Each | - | - |
| 2 | S&F in repairs single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole MCB 20 amps capacity complete all as specified and directed. | 10 | Each | - | - |
| 3 | S&F in repairs metal clad plug two pin and earth complete all as specified and directed. | 10 | Each | - | - |
| 4 | M&L for sub main wiring with 2 run of 4 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant low smoke cable (FRLS) of working voltage 1100 volts grade with stranded copper conductor including one run of 2.5 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with existing 20 mm dia PVC rigid non- metallic conduit after and including taking down / dismantling old sub main wiring of any description complete all as specified and as directed. | 250 | RM | - | - |
| 5 | S&F in repairs compressor including pumping out oil, cleaning the refrigeration system with Co2 and charging refrigerant gas (M-22/F-22) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning suitable for 1.5 - 2.0 TR capacity split type Air conditioner. | 10 | Each | - | - |
| 6 | All as per item No.5 here in before but suitable for refrigerator 180 to 310 ltrs capacity. | 3 | Each | - | - |
| 7 | All as per item No.5 here in before but suitable for Deep freezer for 200 to 320 ltrs capacity. | 3 | Each | - | - |
| 8 | All as per item No. 5 here in before but suitable for Water cooler 80/40 capacity.
Note for Sl item No 5 to 8:- The quoted rate shall deemed to be inclusive of filling / Gas charging. | 3 | Each | - | - |
| 9 | Repair to voltage stabilizer 5 KVA capacity for automatic low and high voltage correction boost / buck transformer by rewinding the transformer coil, replacement of selector switch, PC board, time relay, indicator lamp and three core cable cord with plug top and voltmeter complete all as specified and as directed. | 15 | Each | - | - |
| 10 | All as per item No.9 here in before but for Voltage Stabilizer 3 / 4 KVA capacity | 15 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.14 MB
Tenderdocumerged.pdf
Tender Documents • 2.22 MB
BOQ_892121.xls
BOQ • 1.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .