| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹25.8 LAccepted-AOC 180 SECTOR 1 CHANNI HIMMAT CHANNI HIMMAT JAMMU JAMMU JAMMU AND KASHMIR 180015 UDYAM JK 07 0006292 | JAMMU | JAMMU AND KASHMIR | 180015 | L-1 | Accepted-AOC Being the lowest bidder | |
| 2 | L-2₹27.4 L+₹51,035 (1.90%)Rejected-AOC | L-2 | Rejected-AOC Not being the lowest bidder | |
| 3 | L-3₹29.3 L+₹2.4 L (9.05%)Rejected-AOC 5 A LANE 1 GREATER KAILASH JAMMU J K 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L-3 | Rejected-AOC Not being the lowest bidder | |
| 4 | L-4₹31.1 L+₹4.2 L (15.5%)Rejected-AOC | L-4 | Rejected-AOC Not being the lowest bidder | |
| 5 | L-5₹33.0 L+₹6.1 L (22.6%)Rejected-AOC | L-5 | Rejected-AOC Not being the lowest bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
23 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL SANGRAM SINGH
GE Kaluchak Pin 900673 C/O 56 APO
REPAIR TO ROOF WALL CEILING SUNKEN FLOOR AC CGI FIBRE SHEETS ROOF MEMBRANCE FENCING SECURITY WALL COMPOUND WALL ETC AT KALUCHAK MIL STN UNDER GE KALUCHAK
2020_MES_346837_2
GE/KC/NIT-17/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹60,000
Yes
25 Aug 2020
26 Jun 2020
24 Jul 2020
26 Jun 2020
23 Jul 2020
4 Jul 2020
26 Jun 2020 - 3 Jul 2020
60 days
Amount
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified & directed.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan in any type of soil and getting out, complete all as specified & directed.
PCC 1:4:8, nominal mix, type D-2 using 40mm graded crushed stone aggregate as in foundations, filling & mass concrete, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6 but except brick i.e. using serviceable bricks obtained from Srl item No. 01 here-in-before, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan to any radius, half brick thick walls built in cement mortar 1:4, complete all as specified & directed.
Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided for (Reinforcement cut as required to facilitate demolition), complete all as specified & directed.
TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
TMT bars 5mm dia & over upto & including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified & directed.
PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified & directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Taking down cement plaster on brick or stone surfaces of wall/ceiling, chajjas, roof projections etc upto double storey etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified & directed.
Taking down cement plaster and decayed concrete of any description, upto double storey of building from roof projection, chajjas etc and making good the decayed portion with cement mortar 1:3 mixed with integral water proofing compound or PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate including necessary form work/scaffolding where ever required, rendering with 15 mm thick in cement mortar 1:3, surface finished even and smooth without using extra cement using liquid water proofing admixture as per manufacturer,s instructions, complete all as specified & directed. Note : Liquid water proofing admixture shall be measured & paid seprately.
15mm thick rendering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
15mm thick rendering in cement mortar 1:6 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
10mm thick rendering in cement mortar 1:4 on concrete surfaces of ceiling and similar items, surface finished even and smooth without using extra cement, complete all as specified & directed.
Preparation of new plastered or concrete surfaces of walls and applying two coats of cement base paint, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surface of walls including cornices, pilasters etc by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying one coat of cement base paint, complete all as specified & directed.
Preparation of new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surface of walls including cornices, pilasters etc by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying one coat of white wash, complete all as specified & directed.
Preparation of new plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of primer, complete all as specified.
Preparation of new plastered surfaces of walls and applying two coats of weather proof exterior emulsion paint over a coat of primer, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surface of walls including cornices, pilasters etc by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying one coat of weather proof exterior emulsion paint, complete all as specified & directed.
Preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified & directed.
Preparation of old decorated steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified & directed.
Dismantling posts or structs (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground, posts embedded in concrete, brickwork, masonry etc., complete all as specified & directed.
Excavation in post holes (or similar holes) each not exc. 0.50 cum, in any type of soil and getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc. 25cm, watering and removal of excavated materials to a distance n. exc. 50m and making good surfaces, complete all as specified & directed.
PCC 1:2:4, nominal mix, type B-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified & directed.
Reinforced cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area exc 100 sq. cm but n exc 250 sq. cm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed including necessary form work, complete all as specified & directed.
Dismantling of old rusted galvanised barbed wire/concertina coil of any size & type in any position, complete all as specified & directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified & directed.
Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified & directed.
Fixing only galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified & directed.
Barbed razor tape concertina coil SG hot galvanised spring tensile wire as approved by GE, dia of coil when stretched 1000mm having minimum number of circles 12 RM to 13 RM, minimum number of clips 15/RM & minimum weight of coil 0.96 Kg/RM hot dip galvanised, complete all as specified & directed.
Dismantling of fencing wire mesh of any type & description, complete all as specifed & directed.
Mild steel work in swan neck angles embeded in RCC columns, posts & struts in fencing including cutting tops to shape as directed including drilling holes, notching for wire etc flat iron fillets (for securing wire mesh etc), necessary drilling, bolting or riveting, conforming to Fe-290 grade E-165, complete all as specified & directed. Note : Unit rate shall deemed to include locking holes after fixing of barbed wire and welding to bent up portion as directed.
Mild steel screw bolts (machine made) with hexagonal or square heads at one ends and screwed the other ends, or screwed both ends, each screwed ends to be fitted with washers and one hexagonal or square nut n exc 10cm long, diametre of shank 5 to 10mm, complete all as specified & directed.
Chain link fencing of 4mm dia galvanised steel wire, conforming to IS:2721:2003, 50x50mm mesh including line wires, straining bolts, binding wire etc & fixed, complete all as specifed & directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified & directed.
Rolled mild steel work in roof trusses (framed) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-290 grade-E-165, complete all as specified & directed.
Dismantling timber scantling as in fillets, rails, purlins, etc under 40 sq cm in section, in any position, in unframed work, complete all as specified & directed.
Dismantling timber scantling 40 Sqcm and over in section, in any position (unframed work), complete all as specified & directed.
2nd class hard wood (Sal/Hollock) as in scantling, clean sawn timber, fixed in framed work, complete all as specified & directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof covering, complete all as specified & directed.
Dismantling asbestos cement (corrugated, semi corrugated etc.) sheets in roof coverings, complete all as specified & directed.
Pre-painted galvalume aluminum zinc coating GI based profile steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified & directed.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in as in ridges, hips, valley gutters, drip and straight flashings, fixed with self tapping screws, complete all as specified & directed.
6mm thick asbestos cement, corrugated or semi-corrugated sheeting in roof, walls etc., fixed with L-type or J-type or cranked hook bolts, complete all as specified & directed.
All as per Srl item No.50 above but except sheets.
Asbestos cement two piece adjustable serrated ridge for corrugated or semi corrugated sheets 6mm thick fixed with L-type or J-type or cranked hook bolts, complete all as specified & directed.
2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugation side lap, fixed with self taping screws, complete all as specified & directed.
Dismantling wall & ceiling board (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified & directed.
Suspended false ceiling system using 4mm thick high pressure steam cured fibre cement pre-primed textured varient E-board (classic), ISI marked, conforming to IS:14982-2000 over and including GI snap grid frame work for false ceiling, grid size 605 x 605 mm with GI angle of size 24x24mm, main runner ‘T’ of size 24x38mm, secondary runner ‘T’ of size 24x28mm with 6mm GI wire with butterfly clips as hangers for leveling, fastners, supports, plugs to walls/joists etc all as per manufacturer’s Instructions, including making holes, cutting chasis and making good existing walls in cement mortar 1:3 or PCC 1:2:4 type B1, complete all as specified and directed. Note : All steel members shall be hot dipped galvanised with zinc coating not less than 120 gm/sqm.
Demolition of cement concrete (un-reinforced) of any description in any position not otherwise specifically provided for, complete all as specified & directed.
Water proofing treatment to sunken portion with 15mm thick rendering in cement mortar 1:4 using integral water prooofing compound both on floor and walls including preparation of surface by making free from all loose particles, surface cured and allowed to dry, apply epoxy resins coating of polymer modified cementations coating as per manufacturers instructions both on floor as well on walls, sunken slab shall be laid to a slope of 1:40 outwards with 25mm dia GI pipe spout projecting at least 150mm beyond out face of wall, floor area of WC and bath upto 2.0 Sqm each, complete all as specified & directed. Make : Pedilite/ Bostic/ Fosroc Note : GI spout 20mm dia light grade, PCC 1:4:8 type D2, PCC 1:5:10 type E2 and WC / EWC shall be measured and paid for separately under respective items.
PCC 1:5:10, nominal mix, type E-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified & directed.
75mm thick PCC 1:4:8 (nominal mix), type D-2 using 40mm graded crushed stone aggregate as in base of sunken floor etc, complete all as specified & directed.
Galvanized iron tube as in spout pipe, medium grade, 25mm bore in short length, cut to shape required including cutting holes in walls and making good in cement mortar 1:3, complete all as specified & directed.
Vitreous chinaware squatting pan, 'Orissa Pattern' size 580mm x 440mm with integral foot rests, white, with ‘P’ or ‘S’ trap, front or back inlet, including provision of lime concrete, making connections to trap and to flush pipe etc. and making good to floors, fixed in repairs, complete all as specified & directed.
PVC valveless, syphonic action type flushing cistern, 10 litres capacity, plunger type, low level, white with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long, fixed in repairs, complete all as specified & directed.
Vitreous china wash down water closet (Pedestal pattern), coloured with ‘P’ or ‘S’ trap, plastic water closet seat, white/coloured, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, fixed with screws of suitable size including making connections to trap and to flush pipe etc. and making good to floors, fixed in repairs, complete all as specified & directed.
PVC (SWR) floor trap, plain with grating including jointing to waste pipe with solvent cement, dia of outlet 75mm, fixed in repairs, complete all as specified & directed.
PVC (SWR) pipes, 75mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors, fixed in repairs, complete all as specified & directed.
PVC (SWR) pipes, 110mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors, fixed in repairs, complete all as specified & directed.
110mm bore PVC (SWR) bends any radius, fixed in repairs, complete all as specified & directed.
PVC (SWR) branch piece, single (single Y) equal or unequal, 110mm bore, fixed in repairs, complete all as specified & directed.
Stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, bore of pipe 75 to 100mm, fixed in repairs, complete all as specified.
Cast iron soil, waste and vent pipe, sand cast, 100mm bore in any length with or without ears with cement joints, fixed to walls, fixed in repairs, complete all as specified & directed.
Cast iron bends (any radius) diminishing pieces or tapers (larger bore measured), bore of pipe 100mm, fixed in repairs, complete all as specified & directed.
Cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branchs, bore of pipe 100mm, fixed in repairs, complete all as specified & directed.
Cast iron cowl of 50mm bore, fixed in repairs, complete all as specified & directed.
Cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), dia of outlet 75mm, fixed in repairs, complete all as specified & directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified & directed.
Non skid ceramic jointless coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but nexc 0.11 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:6, complete all as specified and directed .
Glazed ceramic coloured tiles of size 450mmx300mm, thickness 7mm as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed.
Non skid ceramic jointless coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but nexc 0.18 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:6, complete all as specified and directed .
Non skid ceramic jointless coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but nexc 0.18 sqm as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed.
Taking up or down steel tubing and connections 15mm bore, complete all as specifed & directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc,; and cutting chases for concealed water tubing or concealed conduit wiring etc., and making good, cutting exc. 10cm girth but not exc 20cm girth in brick/stone walls, complete all as specified & directed.
Galvanized iron water tubing, medium grade, 15mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
Bib tap, 15mm bore, fancy type, chromium plated, cast copper alloy with capstan head, screwed down, screwed for iron pipe or for brass ferrule, fixed in repairs, complete all as specified & directed.
Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered `Hot’ or `Cold’ with long screwed shanks and fly-nuts, screwed for iron pipe of 15mm bore, fixed in repairs, complete all as specified & directed.
Stop/Angle valves, cast copper alloy, 15mm bore (concealed type), screwed down, high pressure with capstan head, both ends screwed for iron pipe or for union etc., fixed in repairs, complete all as specifed & directed.
Vitreous China, wash hand basin, flat back or angle back, white of size 580mmx450mm including brackets, brass CP waste coupling 32mm dia with long screwed shank and fly nuts, GI medium grade, 32mm dia waste pipe, chain and plug, porcelain stopper, PVC connection 15mm dia, 450mm long with brass CP nuts and washers at both ends, fixed in repairs, complete, complete all as specified & directed.
Complete removal of the existing roof treatment of any description viz tarfelt or membrance surface of roof tiles/concrete padding etc including grubbing up of tree roots, removing all the debris to a distance n exc 100m for roof treatment work, preparation of the concrete roof surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying the following Roof Treatment complete all as specified & directed :- (a) Applying 1st course of 15mm thick screed bed in cement mortar 1:4 over concrete surfaces. (b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
(d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kg/Sqm with 160 Grams/Sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
Brushing neat cement slurry with 3.0Kg of cement per square metre, complete all as specifed & directed.
PCC 1:2:4, nominal mix, type B-0, using 12.5mm graded crushed stone aggregate as in roof padding and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified.
Supply only liquid water proofing admixture, complete all as specifed & directed.
Preparation of new treated surfaces of roof and similar items and applying two coats of aluminium paint, complete all as specified & directed.
M/S Sukhmani Construction Co.
NARESH KUMAR AND COMPANY
J S ENGINEERS
VISHAL CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .