Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.5 LAccepted-AOC | L1 | Accepted-AOC The lowest and negotiated tenderer has been accepted by the CE/TNPHCL | |
| 2 | L2₹41.0 L+₹1.6 L (4.00%)Rejected-AOC 165 PADMAVATHI PURAM OPPOSITE SAP THEATRE AVINSAHI ROAD TIRUPUR 641603 | TIRUPPUR | TAMIL NADU | 641603 | L2 | Rejected-AOC Unsuccessful tenderer | |
| 3 | L3₹44.4 L+₹4.9 L (12.5%)Rejected-AOC | L3 | Rejected-AOC Unsuccessful tenderer |
Tender Value
₹61.2 L
EMD Value
₹40,700
Closing Date
10 Feb 2025, 6:00 pmClosed
The Superintending Engineer/TNPHCL/NC/Salem
The Superintending Engineer/TNPHCL/North Circle, No.1 and 7, Inspectors quarters, PGR Line, Behind CPO Building, Annadhanapatty, Linemedu, Salem 636 006.
Special repair works to the existing 17 quarters INS-3, SI-10 and HC-4, providing entrance gate and new PUF panel roofing for the existing office building at Permanent PRS Inside fort in Vellore District.
2025_TNPHC_520749_1
SE/NC/DB/47/2025
Open Tender
Civil Works
Lump-sum
45 days
Vellore
Refer Tender Documents
7 documents required · 7 mandatory
₹0
₹40,700
18 Mar 2025
27 Jan 2025
12 Feb 2025
27 Jan 2025
10 Feb 2025
27 Jan 2025
Amount
1.1 : Earth work excavation in all soils (including refilling) a. 0 to 2 mt.
21.2 : Teak wood Wrought & Put up a. T.W. over 2 m & below 3 m
b. T.W. below 2 m length.
39 : M.s Grills
41 : Painting - New "iron work"
52 : PVC Water supply (ASTM) c. 25 mm dia
d. 20 mm dia
Electrical arrangements 69 : 16 Amp. Power plug
74 : Charges for fixing of "Fan"
78 : Earthing Station IS3043 (Type I)
87 : ELCB Single Phase
ANNEXURE-I 2.1.3 : Filling crushed stone sand
3.1.1 : C.C.1:5:10 for Foundation & Basement (using crushed stone sand)
6.5.1 : Brick work in C.M. 1:5 (F& B) using Kiln Burnt Country bricks of size 22 x 11 x 7 cm (8 3/4" x 4 1/4"x 2 3/4") (using crushed stone sand) with admixture
8.1.1.1 : Standardised concrete Mix M20 Grade concrete. (using crushed stone sand) a) In Foundation and Basement.
b) In Ground Floor
9.5.1 : Brick work in C.M. 1:6 using Kiln Burnt Country bricks of size 22 x 11 x 7 cm (8 3/4" x 4 1/4"x 2 3/4") (using crushed stone sand) with admixture a. In Ground Floor
10.5.1 : Brick partition work in C.M. 1:4 using Kiln Burnt Country bricks of size 22 x 11 x 7 cm (8 3/4" x 4 1/4"x 2 3/4") 110 mm tk (B.P.) (using crushed stone sand) with admixture b. In Ground Floor
18.1 : Formwork using M.S.Sheet a.For Column footings,plinth beam,Grade beam,Raftbeam,Raft slab etc.,
c.For Square and rectangular columns and small quantities
21.5.2 : Supply and fixing Solid UPVC door shutter with frame
22.1 : TW panelled single door shutter (without brass fittings) a) For door size 900 x 2100mm
22.2 : Supplying and fixing in position of Teakwood shutters with glazed panels for windows and ventilator using suitable styles and rails and 3mm thick ground or frosted glass for panels including labour charges and cost of furniture fittings as per schedule ‘E’ and as directed by the departmental officers. a) suitable for window height 1.20m
22.3.3 : T.W. frame & T.W styles & rails with BWR double leaf shutters for Cup board/ward robes including two coat enamel paint & one coat primer.
33.1 : Plastering in C.M. 1:5, 12 mm tk. (using crushed stone sand) with plasticizer
35.1.2 : Spl. Ceiling plastering in C.M. 1:3, 10 mm tk. (using crushed stone sand) with plasticizer
36.1 : Cement mortar Border in C.M. 1:5, 12 mm tk. (using crushed stone sand) a. 150 mm wide
b. 75 mm wide
38.7 :Plastic Emulsion Paint including primer for new walls
43.1 : Supply & Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.
44.6 : PVC SWR 110 mm dia with ISI mark type- A for Rain water down fall pipe
54.1.1 : S & F of 15mm dia half turn CP long body tap
54.2.1 : S & F of 15mm dia half turn CP short body tap
58.3 : PVC SWR pipe (Soil line) with ISI mark - type 'B'. b. 75 mm dia.
60.1 : PVC Nahani trap (4way/2way)
71.2: Supplying and fixing of 32Amps double pole main switch with fuse and neutral link
75.1.2 : Supply and delivery of 48" (1200 mm) Fan with ISI mark with Eletronic Dimmer
77.6 : Run of 2 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
80: S & F of 375 x 300 x 20mm thick TW plank
85.1Supply and fixing of 40 mm DIA GI pipe B class for EB service connection (Three Phase) for passing through from top of house to the EB board.
214: Dismantling the old damaged brick work in Cement mortar and clearing away from the work site, including labour charges etc all complete and as directed by the departmental officers a) upto 3m height.
ANNEXURE - II A1: Clean removal of cement plaster from walls and racking out joints 20mm deep or from terraced roofs racking out joints 12mm deep without damaging the existing structure and surroundings and clearing the debris away from the site including cost of required tools and plant and necessary scaffolding if necessary etc., all complete in all respect and as directed by the departmental officers.
A2: Clean removal of lime plaster from walls and racking out joints 20mm deep or from terraced roofs racking out joints 12mm deep without damaging the existing structure and surroundings and clearing the debris away from the site including cost of required tools and plant and necessary scaffolding if necessary etc., all complete in all respect and as directed by the departmental officers.
A3: Removing the existing wrought and put up framed timbers in roofs / floors and carefully stacking materials useful for re-use including all labour charges etc., all complete and as directed by the departmental officers.
A4: Removing the Flat & Mangalore tiles over flat tiles without roof timbers and carefully stacking materials useful for re-use including all labour charges etc., all complete and as directed by the departmental officers.
A5: Plastering with CM 1:5, 20mm thick (using crushed stone sand) with plasticizer
A6: White Washing two coats for old walls using clean shell lime slaked including cost of lime, gum, blue, brushes, including thorough scrapping the existing surface, scaffolding etc., all complete.
A7: Colour Washing for Old walls two coats using clean shell lime slaked including cost of lime, gum, blue, brushes, including scaffolding and scrapping the existing surface etc., all complete.
A8: Painting the old wood work with two coat of approved first class enamel ready mixed paint in of approved quality and shade, the paint should be supplied by the contractor at his own cos complying with relevant standard specifications. (Incl. Scrapping)
A9: Waterproofing to RCC Slab: (i) Basic cleaning of the surface to remove dirt, dust, loose particles (ii) Providing and applying a single coat of bitumen emulsion primer and allowed to dry. (iii) Providing and laying 3mm thick APP modified polyester bitumen membrance over the entire primed substrate by torch shield method, sealing all overlaps and joints, completing it as per standard procedure. Waterponding test. After checking for leakage, providing a coat of emulsion for mechanical bonding etc., all complete and as directed by the departmental officers.
A10: Supply and fabrication of roof purlin work arrangements using square tube of size 40x40x3mm thick for horizontal purlins, MS flat 50x50x6mm for support the purlin over the existing wooden truss including labour cahrges for fixing, transportation, fasteners, one coat of red oxide primer etc., all complete and as directed by the departmental officers.
A11: Providing and Fixing of polyurethane foam for Sloped roof as thermal insulation panels or Sandwich insulated panels with external 0.50mm total coated thickness pre painted Galvalume sheet with trapezoidal roofing profile having crest height of 38mm at every 333mm span , whereas internal 0.50mm total coated thickness pre painted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free , high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc& accessories such as screws ,fastners ,sealants etc for fixing the panel etc., complete complying with standard specification. 50mm (+38mm) thick PUF roof panel
A12: Supply and fixing of Galvanium sheet 0.47mm thick for wall cladding works including cost of labour for fixing, washer and bolt connection etc., all complete and as directed by the departmental officers.
A13: Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. (open wiring) a. Light Point with ceiling rose.
b. Light Point without ceiling rose
A14: Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself.(open wiring)
A15: Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Convenient Places.(open Wiring)
A16: Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point.(open Wiring)
A17: Supplying and fixing of LED blubs suitable for fixing it to pendent / bakelite battern holder of best approved variety a) 9 watts LED bulb
b) 12 watts LED bulb for bulk head fittings
A18: Supplying and fixing of 18W LED TUBE LIGHTS 4' long with necessary fittings and charges for assembling and fixing
A19: Supplying and fixing of 25W LED Street light with necessary fittings (Superior variety) Charges for fixing 25W LED lamp street light fittings
A20: Supply and fixing of LED Bulk head fitting for 12W LED Bulb
A21: Run of 2 Wires of 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. (Open Wiring).
A22: Run of 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. (Open Wiring).
A23: Construction of Inspection chamber with brickjelly cement concrete 1:3:16 (One of cement, eight of crushed stone sand and sixteen of broken brick jelly 40mm gauge 15cm, thick for foundation and 23cm thick brick mansonry in c.m 1:5 using fly ash bricks of size 230x110x70mm and plastering with c.m 1:3 (one of cement, three of crushed stone sand and four of hard broken stone 20mm gauge) 5cm thick precast cover slab excluding the cost and fabrication of reinforcement grills but including benching channelling fixing the cover slab in position curing, finishing etc., complete in all respects. a) Inspection Chamber size 60x60x60cm
SURESH (BID ID -1247513)
K RAJAGOPAL (BID ID -1246641)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_619678.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .