Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.6 CrAccepted-AOC 2367 E BAWANA ROAD NARELA DELHI 40 | ₹1.6 Cr Quoted ₹1.5 Cr | 1 | Accepted-AOC PG deposited |
| 2 | 2₹1.7 Cr+₹14.5 L (9.48%)Rejected-Finance | ₹1.7 Cr+₹14.5 L (9.48%) | 2 | Rejected-Finance Not L1 bidder |
| 3 | 3₹1.7 Cr+₹17.3 L (11.3%)Rejected-Finance | ₹1.7 Cr+₹17.3 L (11.3%) | 3 | Rejected-Finance Not L1 bidder |
| 4 | 4₹1.7 Cr+₹20.7 L (13.5%)Rejected-Finance D 5 C C COLONY DELHI 7 | NORTH | DELHI | 110006 | ₹1.7 Cr+₹20.7 L (13.5%) | 4 | Rejected-Finance Not L1 bidder |
| 5 | 5₹2.3 Cr+₹73.9 L (48.4%)Rejected-Finance 00 KHRAUTI RAMPUR BASTI BASTI UTTAR PRADESH 272124 | BASTI | UTTAR PRADESH | 272124 | ₹2.3 Cr+₹73.9 L (48.4%) | 5 | Rejected-Finance Not L1 bidder |
| Sl No | Description | Qty | Unit | M/S RAJ ENTERPRISES L3 | ABHISHEK ENTERPRISES L5 | SANJEEV ASSOCIATES L1 | RAJENDER KUMAR GUPTA L4 | M/s Tara Builders L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00Laying and Jointing PVC Pipe. Heading | ||||||||
| 1.01 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 200 | metre | 334 ₹66,800 | 334.25 ₹66,850 | 334.25 ₹66,850 | 334.25 ₹66,850 | 330 ₹66,000 Lowest |
| 1.02 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 180 | metre | 275 ₹49,500 Lowest | 275.23 ₹49,541.4 | 275.23 ₹49,541.4 | 275.23 ₹49,541.4 | 275 ₹49,500 Lowest |
| 1.03 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire | 93 | metre | 439 ₹40,827 | 439.1 ₹40,836.3 | 439.1 ₹40,836.3 | 439.1 ₹40,836.3 | 435 ₹40,455 Lowest |
| 1.04 | Supplying and fixing suitable size GI box with modular plate and cover in front on
surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket
outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be
used in non residential buildings). | 2 | each | 477 ₹954 | 477.08 ₹954.16 | 477.08 ₹954.16 | 477.08 ₹954.16 | 475 ₹950 Lowest |
| 1.05 | Supplying and fixing suitable size GI box with modular plate and cover in front on
surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps
modular socket outlet and 15/16 amps modular switch, connection etc. as required. | 4 | each | 585 ₹2,340 Lowest | 585.7 ₹2,342.8 | 585.7 ₹2,342.8 | 585.7 ₹2,342.8 | 585 ₹2,340 Lowest |
| 1.06 | Installation, testing and commissioning of ceiling fan, including wiring the down rods
of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper
conductor, single core cable etc. as required. | 4 | No. | 212 ₹848 | 212.69 ₹850.76 | 212.69 ₹850.76 | 212.69 ₹850.76 | 210 ₹840 Lowest |
| 1.07 | Installation of exhaust fan in the existing opening, including making good the damage
connection testing, commissioning etc. as required.Upto 450 mm sweep | 4 | each | 449 ₹1,796 | 449.98 ₹1,799.92 | 449.98 ₹1,799.92 | 449.98 ₹1,799.92 | 445 ₹1,780 Lowest |
| 1.08 | Providing and fixing following rating and breaking capacity and pole MCCB with
thermomagnetic release and terminal spreaders in existing cubicle panel board
including drilling holes in cubicle panel, making connections, etc. as required.125
Amp, 36 KA, FPMCCB | 1 | each | 8,209 ₹8,209 | 8,209.33 ₹8,209.33 | 8,209.33 ₹8,209.33 | 8,209.33 ₹8,209.33 | 8,200 ₹8,200 Lowest |
| 1.09 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve,
miniature circuit breaker suitable for inductive load of following poles in the existing
MCB DB complete with connections, testing and commissioning etc. as
required.Single pole | 12 | each | 255 ₹3,060 | 255.9 ₹3,070.8 | 255.9 ₹3,070.8 | 255.9 ₹3,070.8 | 250 ₹3,000 Lowest |
Tender Value
₹2.6 Cr
EMD Value
₹5.2 L
Closing Date
6 Jan 2025, 3:00 pmClosed
Executive Engineer (EMS)/SZ
O/o the Executive Engineer (EMS)/SZ, Green Park, New Delhi-110016
Providing civil structure for fixed compactor transfer station (FCTS), at DDA land (Khasra No. 134) allotted to MCD near Chouhan Sweet on main Bandh Road) in Sangam Vihar Ward No. 163, South Zone, MCD.
2024_MCD_222203_1
EE (EMS)/SZ/TC/2024-25/04
Open Tender
Civil Works
Percentage
180 days
Sangam Vihar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
₹5.2 L
19 Feb 2026
31 Dec 2024
6 Jan 2025
31 Dec 2024
6 Jan 2025
31 Dec 2024
Amount
Laying and Jointing PVC Pipe. Heading
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 Amp, 36 KA, FPMCCB
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
Supplying and fixing 20 amps 415volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 amps "C" curve, TPMCB, in sheet enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4C*35 sqmm
SITC of 30W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =30 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
SITC of 60W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
Supply of 1200 mm sweep 50 watt, Energy saver ISI Marked BEE 5 Star rating AC Celing fan suitable for 230 V, 50 heartz AC supply without regulator with blades, downrod etc. complete asquired.
SITC of single/three phase monoblock pump set complete with all accessories worable on 240/415 volts, 50 Hz ac supply (a) 1 HP (0.75kw) single phase pump set, head from 12-30 metre suction delivery head from 12-30 metre sunction and delivery 25x25 mm
Supply of 14" (450mm) sweep 1400 rpm exhaust fan heavy duty complete with shutters, blades etc as reqd.
Providing and fixing circular / hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing .
Bidder Name
Amount
M/S RAJ ENTERPRISES (GSTN-07ACMPT3143K1Z7) BID ID -803710
ABHISHEK ENTERPRISES (GSTN-NA) BID ID -803273
SANJEEV ASSOCIATES (GSTN-NA) BID ID -803869
RAJENDER KUMAR GUPTA (GSTN-NA) BID ID -803223
M/s Tara Builders (GSTN-NA) BID ID -802683
M/S RAJ ENTERPRISES (BID ID -803710)
SANJEEV ASSOCIATES (BID ID -803869)
RAJENDER KUMAR GUPTA (BID ID -803223)
ABHISHEK ENTERPRISES (BID ID -803273)
M/s Tara Builders (BID ID -802683)
M/S RAJ ENTERPRISES (BID ID -803710)
RAJENDER KUMAR GUPTA (BID ID -803223)
ABHISHEK ENTERPRISES (BID ID -803273)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tenderdocument.pdf
Tender Documents • 3.12 MB
BOQ.xls
BOQ • 0.30 MB
Tenderdocument_2.pdf
Tender Documents • 3.14 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .