| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹41.5 L+₹4.5 L (12.2%)Rejected-Finance HIMACHAL BUILDING SHOP NO 10 CD BARFYWALA ROAD JUHU LANE ANDHERI W MUMBAI 400058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | L2 | Rejected-Finance Not Reasonable | |
| 3 | L3₹44.0 L+₹7.0 L (19.0%)Rejected-Finance | L3 | Rejected-Finance Not Reasonable | |
| 4 | L4₹44.9 L+₹7.9 L (21.2%)Rejected-Finance 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L4 | Rejected-Finance Not Reasonable | |
| 5 | L5₹45.0 L+₹8.0 L (21.7%)Rejected-Finance NOT AVAILABLE | L5 | Rejected-Finance Not Reasonable |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Jun 2023, 6:00 pmClosed
Sh Saurabh Gupta, EE
GE(W) Colaba, Mumbai
REPAIR / MAINTENANCE OF UNSERVICABLE LT PANEL / FEEDER PILLAR BOXES INCLUDING CONNECTED ITEMS INSTALLED AT ARMY AREA UNDER GE (WEST) COLABA, MUMBAI.
2023_MES_595944_1
8752/E8
Open Tender
Civil Works
Item Rate
180 days
GE(W) Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE(W) Colaba, Mumbai
₹90,000
Yes
24 Jul 2023
16 May 2023
15 Jun 2023
16 May 2023
13 Jun 2023
30 May 2023
Amount
Excavation in trenches, nexc1.5 m wide and nexc 1.5 m in depth and getting out in soft/loose soil all as specified and directed.
All as per item No.01 above but in hard/dense soil.
Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 in depth and getting out in hard rock/road cutting/RCC/PCC all as specified and directed.
Supply and laying crushed stone sand for sand cushioning for cable protection or filling in trenches of sand in cable ducts after cleaning of ducts all as directed and specified Note:. for the purpose of payment punned thickness will be measured.
Returning, fillingin including spreading, levelling, watering, well ramming in layers n.exc 25 cm in soil all as specified and directed.
Removing excavated soil not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point in soil all as specified and directed.
Removing excavated soil from the site of work and transporting out of MoD land all as specified and directed.
Supply and laying unreinforced pre cast cement concrete cable cover for cable protection (Ready made Covers) of sizes Class LV type I, flat size 250x150x40 mm putting adjecent to each other all as specified and directed.
Supply and laying High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 90mm dia for laying of cable protection to walls/ trenches/floor/ceilings all as specified and directed by Engineer-in-Charge.
Supply and laying tubes light grade, galvanized, 100 mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as specified and directed.
Supply and laying tubes light grade, galvanized iron, 80 mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as specified and directed.
Supply and laying tubes light grade, galvanized, 50 mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as specified and directed.
M&L PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) for foundatuion/road filling and mass concrete all as specified and directed.
Taking down for old unserviceable cable from trench/wall/duct all as specified and directed.
Supplying, laying, commissioning & testing LT underground cables 300 Sqmm X 3.5 Core, 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded aluminium conductor all as per IS 7098 (Part -1) laid in trenches, ducts, drawn through pipes or fixed on poles, as and when required on ground all as specified and directed.
All as per item no 15 above but 240 Sqmm X 3.5 Core
All as per item no 15 above but 185 Sqmm X 3.5 Core
All as per item no 15 above but 120 Sqmm X 3.5 Core
All as per item no 15 above but 95 Sqmm X 3.5 Core
All as per item no 15 above but 70 Sqmm X 3.5 Core
All as per item no 15 above but 50 Sqmm X 3.5 Core
All as per item no 15 above but 35 Sqmm X 3.5 Core
M&L for cable fault detection at various locations by all T&P, equipments for LT CABLE XLPE aluminium conductor including testing and commissioning all as specified and directed
M&L in repairs cable jointing kit for LT cable XLPE aluminium conductor including testing and commissioning for the size of 35sqmm X 3.5 Core all as specified and directed.
All as per item No 24 above but of size 50sqmm X 3.5 Core all as specified and directed
All as per item No 24 above but of size 70sqmm X 3.5 Core all as specified and directed
All as per item No 24 above but of size 95sqmm X 3.5 Core all as specified and directed
All as per item No 24 above but of size 120sqmm X 3.5 Core all as specified and directed
All as per item No 24 above but of size 185 sqmm X 3.5 Core all as specified and directed
All as per item No 24 above but of size 240sqmm X 3.5 Core all as specified and directed
All as per item No 24 above but of size 300sqmm X 3.5 Core all as specified and directed
Taking out/down old cable and rerouting, relaying the same after checking, meggaring complete LT underground cables, 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty of size 10 sqmm X 2 Core to 50sqmm X 3.5 Core including connecting up electric power to panel/feeder box all as specified and directed.
Taking out/down old cable and rerouting, re laying the same after checking, meggaring LT underground cables, 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty of size 70 sqmm X 3.5 Core to 240 sqmm X 3.5 Core including connecting up electric power to panel/feeder box all as specified and directed.
Dismantling of existing damaged/burnt MCCB and Supply & fixing of MCCB, 4 Pole, 320 Amps, 35/36kA, 415 Volts, 50Hz ACs with enclosure of 2.00 mm thick for indoor S/S fixing on wall all as specified and directed by Engr-in-charge. Make:Make-Legrand / Schneider / L&T
Dismantling of existing damaged/burnt MCCB and supply & fixing of MCCB, 4 Pole, 320 Amps, 35/36kA, 415Volts, 50Hz ACs all as specified and directed by Engr-in-charge. Make;- Make-Legrand / Schneider / L&T
Dismantling of existing damaged/burnt MCCB and Supply & fixing of MCCB, 3 Pole, 200 Amps, 35/36kA, 415Volts, 50Hz ACs all as specified and directed by Engr-in-charge. Make: Make-Legrand / Schneider / L&T
Dismantling of existing damaged/burnt MCCB and Supply & fixing of MCCB, 3 Pole, 160 Amps, 36kA, 415Volts, 50Hz A s all as specified and directed by Engr-in-charge. Make: Make-Legrand / Schneider / L&T
Dismantling of existing damaged/burnt MCCB and Supply & fixing of MCCB, 3Pole, 100 Amps,10kA, 415Volts, 50Hz ACs all as specified and directed by Engr-in-charge. Make: Make-Legrand / Schneider / L&T
Dismantling of existing damaged/burnt MCCB and Supply & fixing of MCCB, 3 Pole, 63 Amps,10kA, 415Volts, 50Hz ACs all as specified and directed by Engr-in-charge. Make: Make-Legrand / Schneider / L&T
Dismantling of existing damaged/burnt change over switch and Supply & fixing of Change Over Switch, 4Pole, 250 Amps, open Execution, ON LOAD type 415Volts, 50Hz AC s all as specified and directed by Engr-in-charge. Make:- Make-Legrand / Schneider / L&T
M&L for dismantling of existing damaged APFC panel power contactor and supply and fixing in repair power contactor 3 pole, 32 Amp to 63 Amp (MNX 32) 240 volts suitable for 5 KVAR capacitor to 20 KVAR Capacitor to automatically correct the power factor for indoor type transformer as required at site all as specified and directed by Engineer -in -Charge. Make:- L&T Cat No. CS94111 or equivalent.
M&L for dismantling of existing damaged TP from APFC panel and Supply and fixing in repair TP 40 amp MCB 440 Volts suitable for 5 KVAR capacitor to 20 KVAR Capacitor to automatically correct the power factor for indoor type transformer all as specified and directed by Engineer -in -Charge. Make:- L&T , Leegrand or equivalent.
M&L for dismantling of existing damaged relay of any stage from APFC panel and supply and fixing in repair APFC relay of 8 to 12 stage as per requirement 1A or 5A for load with class 2 accuracy 440 volts suitable for 5 KVAR capacitor to 20 KVAR Capacitor to automatically correct the power factor for indoor type transformer all as specified and directed by Engineer -in -Charge. Make:- L&T , Leegrand or equivalent.
M&L for dismantling of existing damaged APFC panel capacitor and Supply and fixing in repair heavy duty square type 5KVAr capacitor 440 Volts, 6.56 Amp Ir, 3 × 27.4 µF capacitor suitable 100 to 300 KVAR APFC panel to automatically correct the power factor for indoor type transformer all as specified and directed by Engineer -in -Charge. Make:- Epcos, or Havells or Equivalent
M&L for dismantling of existing damaged APFC panel capacitor and Supply and fixing in repair heavy duty square type 10 KVAr capacitor 440 Volts, 13.12 Amp Ir, 3 × 54.8 µF capacitor suitable for 100 to 300 KVAR APFC panel to automatically correct the power factor for indoor type transformer all as specified and directed by Engineer -in -Charge. Make:- Epcos, or Havells or Equivalent
M&L for dismantling of existing damaged APFC panel capacitor and Supply and fixing in repair heavy duty square type 20 KVAr capacitor 440 Volts, 26.242 Amp Ir, 3 × 109.6 µF capacitor suitable 100 to 300 KVAR APFC panel to automatically correct the power factor for indoor type transformer all as specified and directed by Engineer -in -Charge. Make:- Epcos, or Havells or Equivalent
Cleaning the vegetation including glass, bushes small trees and all vegetation growth complete including digging out the root of bushes and small trees around the installation/Feeder panel etc. filling the rough holes with earth and levelling the surfaces by removing all debris outside MD land all as specified and directed.
M&L spray painting to indoor/outdoor type, feeder panel installed at different location of GE (west) Colaba area after scraping throughly the existing corroded paint/rust, filing of cavaties and applying two coats of heat resistant paint of approved quality of required colour and writing/marking the In/ Out cables and MCCBs etc. all as per specified and directed by Engr - in - Charge.
M&L fabrication work with cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint for substation cable duct all as specifeid and diredted by Engr-in-charge.
M&L in repairs/ Overhauling/Servicing to Existing LT electric FPB Out door type by taking shut down from appropiate authority including following activities (a) Tightning the loose connections and cleaning inside/out side complete by replacing all cable defective glands, thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors, providing new insulation tape to bus bars, repairs to broken/hanging doors by fixing hinges or welding the door to make it servicable, spray painting (silver colour) /powder coating and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge all as specified and directed . Note : MCCB, ACB, painting, measured and paid separately under relevant items of this schedule.
M&L in repairs/ Overhauling/servicing to existing LT electric panels indoor type of each Transformer by taking shut down from appropiate authority including following activities (a) Tightning the loose connections and cleaning inside/out side complete by replacing all cable glands, thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors, providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting (silver colour)/powder coating and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge all as specified and directed. Note : MCCB, ACB, painting will be measured and paid separately under relevant items of this schedule.
M&L in repairs/ Overhauling/servicing to existing LT APFC panels indoor type of each Transformer by taking shut down from appropiate authority including following activities (a) Tightning the loose connections and cleaning inside/out side complete by replacing all cable glands, thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors, providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting (silver colour) /powder coating and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge all as specified and directed . Note : Defect MCB, contactor, relay, capacitor bank will be measured and paid separately under relevant items of this schedule.
Supply, install ,testing and commissioning of factory made LT Panel board outdoor type made totally enclosed dust & vermin proof single opening with double leaf shutter duly hinged with locking arrangement made of MS angle iron frame work & CRCA sheet of 3.15 mm thick as per IS 5039, CPRI approved, duly painted with powder coated of approved shade over a coat of zinc chrome primer after min seven tank treatment process including numbering & lettering mounted on C channel of appropriate size. Neccessary holes shall be kept on the kiosk box for incoming and outgoing cable entry, all holes shall be provide with brass cable gland of apprppriate size. The feeder pillar box shall be suitable for 415 volts, 50Hz , 3 phase 4 wire system & shall comprise with suitable capacity aluminium TPN bus bar chamber having 3 phase 4 wire system fixed on porceilin insulator with suitable size PVC copper conductor and duly sleeved with 4 coloured heat shrinkable PVC sleeve, thimble & glands. the pannel board shall confirm as per IP 52 complete all as directed with foliowing accessories. (Note:-The cost of the PCC plateform deemed to be included in the qouted rates of above said item complete all as specified & directed). Incoming (a) MCCB 4 pole, 415 Volts, 250 Amps, 35KA - 01 No. (b) Voltmeter digital type (c) Ammeter digital type (d) Phase indicator lamps (RYB) -set of 3 Outgoing (a) MCCB 3 pole, 415 Volts, 160 Amps, 25 KA - 02 No. (b) MCCB 3 pole, 415 Volts, 100 Amps, 25 KA - 03 No. (c) MCB 3 pole, 415 Volts,40 Amps, 10 KA - 02 No. (d) MCB 2 pole, 415 Volts,20 Amps, 10 KA - 02 No. Make of MCB/MCCB:- Legrand / Schneider / L&T
M&L for earthing complete with GI earth plate electrode 60 cm X 60 cm X 6 mm thick, burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.50 mtr below normal ground level connected to GI earth lead strip 25 x 4 mm dia by means of GI bolts, nuts, check nuts, washers made out of GI/steel, all as shown on electrical plate No 3 of MES schedule part-I, earth lead strip connected to indicated position including concrete pit in PCC (1:3:6, C1, precast RCC cover slab 55 cm x 55 cm x 5 cm with reinforcement of 8 mm dia bar 100 mm c/c bothways including one handle made of 12 mm dia MS bar embedded in pre cast slab and 20 mm bore galvanised iron pipe "medium grade" for watering with GI funnel and wire mess including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil all as specified and as directed and testing on completion all as specified & directed.
S&F in repairs earth continuty conductor fixed to wall/surface or recess or burried in ground or any situation for loop earthing by 25 X 4 mm GI strip all as specified and directed by Engineer-in-Charge.
M/s PIONEER CONTRACTORS
NOEL ENGINEERS
Om Sai Enterprises
SHREE JAGDISH FURNITURE CO.
SHREE SHIV ELECTRICAL
AGRAWAL ASSOCIATES
OM SAI POWER SYSTEMS
Bidder Name
AGRAWAL ASSOCIATES
OM SAI POWER SYSTEMS
NOEL ENGINEERS
Om Sai Enterprises
SHREE JAGDISH FURNITURE CO.
SHREE SHIV ELECTRICAL
N.S.ENTERPRISES
M/s PIONEER CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .