| Sl No | Description | Qty | Unit | Laxmi Associates L2 | ALEXEN POWER ENGINEERS PRIVATE LIMITED L1 |
|---|---|---|---|---|---|
| 1.001- Online Testing to be conducted on Transformer:- (i) On line Partial Discharge Measurement (ii) Thermographic Measurement (iii) Noise Level Measurement (iv) Vibration Level Measurement (v) Oil Test ( NABL Approved Lab) a- General Oil test as per IS 1866:2000 (Resistivity, Tan Delta, BDV, Water PPM, IFT. Acidity, Flash point & Sludge content) b- DGA as per relevant IEC c- Furan analysis 2- Offline Testing to be conducted on Transformer (i) Capacitance & Tan Delta of bushing & windings (ii) Turn Ration at each taps (iii) Vector Group test (iv) Short Circuit Impedance test (v) Megnetizing current on each tap (vi) Magnetic blance test(vii) Winding resistance at all taps(viii) IR & PI test(ix) Sweep Frequency response analysis test & Mechanical assessment.(x) Frequency response on stray loss test (FRSL)(xi) Leakage Reactance & Impedance measurement(xii) Dynamic Contact resistance test for OLTC performance check.(xiii) Moisture assessment & Dielectric analysis of winding insulation (FDS measurement) 1- Online Testing to be conducted on Transformer:- (i) On line Partial Discharge Measurement (ii) Thermographic Measurement (iii) Noise Level Measurement (iv) Vibration Level Measurement (v) Oil Test ( NABL Approved Lab) a- General Oil test as per IS 1866:2000 (Resistivity, Tan Delta, BDV, Water PPM, IFT. Acidity, Flash point & Sludge content) b- DGA as per relevant IEC c- Furan analysis 2- Offline Testing to be conducted on Transformer (i) Capacitance & Tan Delta of bushing & windings (ii) Turn Ration at each taps (iii) Vector Group test (iv) Short Circuit Impedance test (v) Megnetizing current on each tap (vi) Magnetic blance test (vii) Winding resistance at all taps (viii) IR & PI test (ix) Sweep Frequency response analysis test & Mechanical assessment. (x) Frequency response on stray loss test (FRSL) (xi) Leakage Reactance & Impedance measurement (xii) Dynamic Contact resistance test for OLTC performance check. (xiii) Moisture assessment & Dielectric analysis of winding insulation (FDS measurement) | |||||
| 1.01 | 132/33 KV 40 MVA T/F-I (Alstom Make, Mfg. 1999) at 132 KV Substation, Colonelganj. | 1 | No. | 1,44,985 ₹1,44,985 | 1,31,865 ₹1,31,865 Lowest |
Tender Value
₹1.8 L
EMD Value
₹1,800
Closing Date
2 Aug 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC GONDA
220 KV SUBSTATION CAMPUS JAIL ROAD GONDA
Work
2025_UPTCL_1054739_1
04/ETC(GD)/2025-26
Open Tender
Electrical Works
Fixed-rate
30 days
Gonda
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
EE ETD GONDA
₹1,800
13 Aug 2025
5 Jul 2025
2 Aug 2025
5 Jul 2025
2 Aug 2025
5 Jul 2025
Amount
1- Online Testing to be conducted on Transformer:- (i) On line Partial Discharge Measurement (ii) Thermographic Measurement (iii) Noise Level Measurement (iv) Vibration Level Measurement (v) Oil Test ( NABL Approved Lab) a- General Oil test as per IS 1866:2000 (Resistivity, Tan Delta, BDV, Water PPM, IFT. Acidity, Flash point & Sludge content) b- DGA as per relevant IEC c- Furan analysis 2- Offline Testing to be conducted on Transformer (i) Capacitance & Tan Delta of bushing & windings (ii) Turn Ration at each taps (iii) Vector Group test (iv) Short Circuit Impedance test (v) Megnetizing current on each tap (vi) Magnetic blance test(vii) Winding resistance at all taps(viii) IR & PI test(ix) Sweep Frequency response analysis test & Mechanical assessment.(x) Frequency response on stray loss test (FRSL)(xi) Leakage Reactance & Impedance measurement(xii) Dynamic Contact resistance test for OLTC performance check.(xiii) Moisture assessment & Dielectric analysis of winding insulation (FDS measurement) 1- Online Testing to be conducted on Transformer:- (i) On line Partial Discharge Measurement (ii) Thermographic Measurement (iii) Noise Level Measurement (iv) Vibration Level Measurement (v) Oil Test ( NABL Approved Lab) a- General Oil test as per IS 1866:2000 (Resistivity, Tan Delta, BDV, Water PPM, IFT. Acidity, Flash point & Sludge content) b- DGA as per relevant IEC c- Furan analysis 2- Offline Testing to be conducted on Transformer (i) Capacitance & Tan Delta of bushing & windings (ii) Turn Ration at each taps (iii) Vector Group test (iv) Short Circuit Impedance test (v) Megnetizing current on each tap (vi) Magnetic blance test (vii) Winding resistance at all taps (viii) IR & PI test (ix) Sweep Frequency response analysis test & Mechanical assessment. (x) Frequency response on stray loss test (FRSL) (xi) Leakage Reactance & Impedance measurement (xii) Dynamic Contact resistance test for OLTC performance check. (xiii) Moisture assessment & Dielectric analysis of winding insulation (FDS measurement)
132/33 KV 40 MVA T/F-I (Alstom Make, Mfg. 1999) at 132 KV Substation, Colonelganj.
Laxmi Associates (BID ID -5357831)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .