Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹20.0 L+₹94,031.85 (4.94%)Rejected-AOC B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-AOC L2 Bidder |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
27 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Amla
GE AF Amla, Betul Dist 460553 (MP)
REPAIR/MAINTENANCE OF LT DISTRIBUTION SYSTEM AND CONNECTED WORKS AT AFS AMLA
2022_MES_533227_1
8492/E8 of 2022-2023
Open Tender
Civil Works
Item Rate
335 days
GE AF Amla
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Amla
₹40,000
Yes
26 Aug 2022
23 Jun 2022
29 Jul 2022
23 Jun 2022
27 Jul 2022
7 Jul 2022
Amount
Taking out carefully PVC insulated sheathed armoured stranded aluminium conductor LT underground cable from trenches/ ducts/ walls etc., including necessary dismantling, demolition and disconnecting cables from existing power line complete all as specified and as directed for the following sizes of cable:- Note :- (i) Earth work excavation, returning filling and disposal shall be measured & paid separately under respective items. (ii) The surface disturbed during dismantling/demolition shall be made good by contractor at his own cost by using 1:2:4 type B1 concrete (or) in CM 1:4 which deemed to be included in the contractor quoted rate.
25 to 95 Sq. mm 3.5 core
240sq. mm, 3.5 core
Supply lay & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, laid in trenches/passing through pipe/duct or fixed to wall/pole etc., and connecting up complete all as specified and directed for the following cross-sectional area size of cable:-
25 Sq. mm 4 core
35 Sq. mm 3.5 core
50 Sq. mm 3.5 core
95 Sq. mm 3.5 core
240 Sq. mm 3.5 core Notes for Item No 2 to 2.05: - (i) The minor parts such as clamps, screw etc., required for fixing cables on wall, panel etc., shall be provided by the contractor at his own cost which is deemed to be included in the contractor quoted rate. (ii) Earth work excavation, returning filling and disposal, protection pipe & joint kit shall be measured & paid separately under respective items.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for laying cables and getting out in hard/dense soil complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0m in depth; for laying cables and getting out in hard/dense soil complete all as specified and directed.
Returning filling in excavated soil including spreading levelling and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing surplus excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as directed.
Supply and spread dry river washed sand free from foreign material in trenches for cable cushioning all as specified and directed. Note:- For payment purpose only punned thickness of sand will be measured & paid.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm all as specified and as directed.
Material and labour for Galvanised steel tubing, light grade laid in trenches/ fixed to poles, walls etc as a protection for service cable including removing existing old unserviceable rusted pipe complete all as specified and directed for the following size of pipe:-
50mm dia bore
80mm dia bore Notes for Item No 9.01 to 9.02:- (i) The minor parts such as clamps, screw etc.,, required for fixing pipe on wall, pole, panel etc., shall be provided by the contractor at his own cost which is deemed to be included in the contractor quoted rate.
Dismantling of concrete pole/ strut, any size embedded in cement concrete foundation etc., and setting aside for reuse within 50 metres or disposing off MD land complete all as directed.
M&L for providing horizontal bore hole of dia upto 120mm below road/hard standing surface for the length upto 10 Metre and inserting GI/PVC pipe into the bore hole as cable protection complete all as specified and as directed. Note:- Cable protection pipe shall be measured and paid separately under relevant item.
Supply & erection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (8.50 metres long) including appllication of two coat of aluminium paint over one coat of red oxide zinc chrome primer above ground level and two coat of bituminous paint below ground level complete all as specified and directed.
Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations, filling and mass- concrete, complete all as specified & directed.
Material and labour for plain cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in foundations, filling and mass- concrete, complete all as specified & directed.
Material and labour for plain cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in coping and the like including necessary form work etc, complete all as specified & directed.
M&L for plate earthing with galvanised mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 25 x 4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of HT/LT equipment’s etc at the other end including 32 mm GI light grade pipe with all fittings from top of electrode to body of equipment fixed with iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate and RCC cover complete all specified and shown in electrical plate No 3 of SSR Part-1 including testing earth resistance and submitting test report to AGE E/M by the contractor complete all as specified & directed. Note :- (i) Earthing resistance required in earthing shall less than 1.0 Ohms after completion of work. All earthing shall be tested by the contractor in presence of Engr-in-Charge. Test result shall be recorded and signed by the contractor and Engr – in- Charge. If contractor fail to achieve the above result the same shall be rectified by the contractor without any extra cost to Govt. The earthing result will be required maintaining up to end of defect liability period of one year and if any variation found in earthing result during defect liability period same will be intimated to the contractor by Engg-in-Charge and contractor shall rectify the same. The quoted rates shall be deemed to include for above said provision. (ii) Quoted rates shall be deemed to be included for earth strip with protection pipe up to 7.5 length.
Supply & fixing in repairs 25x4mm galvanised iron strip earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including taking out old one complete all as specified and directed.
Supply & fix in repair out door type straight through joint heat shrinkable type for LT XLPE / PVC 1100 volt grade cable and connecting the cable including testing on load complete all as specified & directed for the following size of cables:-
LT cable size 3.5/4 X 25 to 50 Sq mm
LT cable size 3.5/4 X 70 to 120 Sq mm
Supply & fix in repair Junction box of size 300mm x 450mm x170mm with Aluminium bus bar rating three phase 150 Amp and neutral 75 Amp, IP 65 having provision for metric knockouts for cable entry up to 70 Sq mm including Aluminium painted GI clamps 30x 4mm thick with nuts, bolts, washers and testing complete all as specified and directed. Make:- Hensel cat no K-7004 equivalent make as approved by ge
Supply & fix in repairs MCCB, 415 Volts, 4 pole with thermal magnetic release type of the following ratings:-
MCCB 630 Amp, 415 Volts, 4 pole, breaking capacity 50 KA
MCCB 400 Amp, 415 Volts, 4 pole, breaking capacity 36 KA
MCCB 250 Amp, 415 Volts, 4 pole, breaking capacity 36 KA
MCCB 200 Amp, 415 Volts, 4 pole, breaking capacity 25 KA
MCCB 160 Amp, 415 Volts, 4 pole, breaking capacity 16 KA
Supply and fix in repairs ACSR Overhead conductor of any size, to be fixed on pole/ jumper connections/ on insulator by means of necessary binding with 14 SWG including taking out old one complete all as specified and directed. Note:- The ACSR wire supplied by contractor shall conform to IS 398-1976 part II
Material & labour for painting of steel poles of 8.5/9.0 m height with two coats of aluminium paint over a coat of red oxide primer including painting of channels, cross arm angles etc., on pole after necessary preparing of the surface by removing dust, rust etc. complete all as specified and as directed.
Supply and fix in repair cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including two coats of aluminium paint over a coat of red oxide zinc chrome primer including taking out old one complete all as specified and directed.
Restringing, tightening of ACSR conductors of 3 phase 3 wire system, measured as single run on poles including necessary aluminium binding wire, connectors, etc, as in fixed in repair complete all as specified and directed.
Restringing, tightening of ACSR conductors of 3 phase 4 wire system measured as single run on poles including necessary aluminium binding wire, connectors, etc, as in fixed in repair complete all as specified and directed.
Restringing, tightening of ACSR conductors of single phase 2 wire system measured as single run on poles including necessary aluminium binding wire, connectors, etc, as in fixed in repair complete all as specified and directed.
Material and labour for cutting/ trimming tree branches coming on overhead line LT/ HT lines minimum 02 metre space all around the conductor including disposing off trimmed branches upto lead of 50m apart complete all as directed.
Supply & fix in repairs Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height 65 mm dia for 1100 volts grade including taking out old one complete all as specified and directed.
Supply & fix in repairs line separators for OH line PVC insulated and PVC nut and bolt hook up/spiral suitable for single phase 2 wire system including taking out old one complete all as specified and directed.
Supply & fix in repairs line separators for OH line PVC insulated and PVC nut and bolt hook up/spiral suitable for 3 phase 4 wire system including taking out old one complete all as specified and directed.
Material & labour for marking of pole number with black luminous words on luminous yellow round sticker as per sample complete all as specified and as directed.
Dismantling old unserviceable LT panel carefully after disconnecting power supply and Supplying, Installing, connecting & testing of LT panel outdoor type of size 2700mm x 2175 mm x 800mm, CPRI approved, weather and vermin proof, factory fabricated, epoxy powder coated paint, cubical type, made out of CRCA sheet 03 mm thick with mounting on frame of angle iron 75 x 75 x 6 mm fixed on ground but not less than height 30 cm from ground level suitable for 415 volt, 3 phase, 4 wire system with front double door and rear single door with both side sliding tower bolts for locking arrangement including internal wiring with suitable size of copper standard wire complete all as specified, comprising of the following equipment’s/ fitments complete all as specified and as directed:-
INCOMER (a) MCCB 630 Amps, 4 pole fixed type, breaking capacity 50 KA, microprocessor based release with overload/short circuits and earth fault protection - 01 No (Incoming) (b) Spreader Terminal - 01 No (c) Rotary Handle - 01 No (b) R/Y/B Indication - 03 Nos (c) Digital Ammeter - 01 No (d) Digital Volt meter 0-500 Volts - 01 No (e) CTs 600/5A -03 Nos (f) Control 6A SP MCB - 06 Nos (g) Fuse base with link - 03 Nos (h) Surge protection device maximum continuous operating voltage 275 volts short circuit withstand (icc) 50 KA - 01 No
OUTGOING (a) MCCB 400 Amps 04 Poles, breaking capacity 50 KA with thermal magnetic release with over load/short circuit protection - 02 Nos (i) Spreader terminals - 03 Nos (b) MCCB 160 Amps 04 Poles, breaking capacity 16 KA with thermal magnetic release with overload/short circuits protection - 01 Nos (i) Spreader terminals - 03 Nos (c) Rotary handle - 08 Nos
Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
Shri Sai Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .