Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance F NO C 102 KUSHAL VIHAR S NO 84 1 19 JAWALKAR NAGAR PIMPLE GURAV PUNE MAHARASHTRA 411061 | PUNE | MAHARASHTRA | 411061 | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical As per TEC Report |
| 5 | Rejected-Technical | Rejected-Technical As per TEC Report |
Tender Value
Refer Docs
Closing Date
29 Sept 2023, 3:00 pmClosed
Manager-Admin (Purchase)
CDAC Panchvati, Pashan Pune 8
Upper Ground Floor Canteen Modification Work at the C-DAC IP building, Pashan, Pune
2023_DIT_769524_1
CDACP/L and B/UG CANTEEN/15418/23-24
Open Tender
Civil Works - Others
Works
60 days
Pune
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
CDAC
ONLINE -08/09/23 @ 11.30 AM
22 Feb 2024
31 Aug 2023
29 Sept 2023
31 Aug 2023
29 Sept 2023
22 Sept 2023
1 Sept 2023 - 7 Sept 2023
8 Sept 2023
Amount
Civil and Allied Work (Dismentaling of old material)
Cutting and Removing cement tiles or parking tiles or vetrified tiles or marble or polished shahabad floor or dado with out bed concrete as per project quirement including removal of cement mortor, stacking the materials as directed with all leads, lifts etc. complete.
Disposal of Debris: Loading to trauck, the generated Debris out side of CDAC Campus, etc completed
P &L Granite : Providing and laying in position flooring of Steel grey granite stone ( white line) of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 with leather finished polishing to Granite Stone slab by continuous grinding in 4 coats curing and cleaning (Base price of granite with 4 coat leather polishing Rs. 1023/Sq.M. )etc. complete.
GI False Ceiling : Providing and fixing tiled false GI Metal Ceiling Lay in plain Tegular edge Global whitecolor tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending, in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge
GI False Ceiling : Providing and fixing tiled false GI Metal Ceiling Lay in plain Tegular edge in required color(Powder Coated) tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending, in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge
Removing old paint like dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches scaffolding etc. complete
Providing and laying exterior tiles having size 30 cm. x 60 cm of thickness 9mm and above confirming to corresponding I.S. for dado ( As per approved pattern) in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete,(Please ref. image 1).
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat, scaffolding if necessary , and watering the surface for two days etc complete
Luster Painting: Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc.complete
Removing old aluminium panel: Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge
Green Wall: providing and fixing vertical green wall of semi-Intensive aluminium frame grid (made of 50x50mm box aluminium section of 2mm thk) spaced at 450mm c/c vertically and horizantally for vertical green wall pot fixing with 30 pots per SQ. M. (approx size 14cm x 12 cm top size, 6.5 cm x 6.5 cm bottom size with one side tepered reducing diamension, with height of 12 cm), etc. completed, ( plaese ref. image no. 2)
ELECTRICAL & ALLIED WORKS
Suply and installation of 8-way,SPN, Metal type, Double Door (As approved by client / consultant / architect) UPS /Raw Power Distribution Board, surface / flush mounted on wall, interconnected wiring complete with earthing lugs, including DB wiring dressing with ferruling, termination of circuits with ping type copper lugs, blank plates, etc. housing following switchgears : (Schneider / Hager / Siemens / Legrand make as approved by client / consultant),I/C-32 A DP MCB,6 Numbers 10/16 AMP SP MCB as Outgoings
Supply and installation of 3C x 6 sqmm copper flexible FRLS cable with 2 run of 12 SWG GI bare wire (Panel to DB)
LIGHTING POINTS IN ROOM,
Supply & Installation of concealed / ressessed / surface light point / fan point / call bell point wiring using 600V FRLS grade 3R (P+N+E) x 1.5 Sq.mm copper conductor PVC insulated wires (with proper R,Y,B color code) pulled through new heavy gauge 25 mm PVC conduits to be laid concealed over false ceiling or in wall chases or on the ceiling in case of an open ceiling including 3R (P+N+E) x 2.5 Sq.mm circuit wires from the relevant DB and also including 2.5 sqmm green color copper earth wire and approved make modular type switch plate, switches, MS concealed back box, etc. as required & as approved by the consultant. (Each circuit shall not feed more than 8 points OR 800 watts as per following configuration.) Note: 1)The item rate shall inclusive ofLighting / Raw / UPS Power Circuit wiring from relevent DB to the Light fittings with 3Rx2.5 Sq.mm FRLS wires & from switch board to next switch board OR to the first light point / primary point / full point 2) Rate shall be inclusive of new heavy gauge 25 mm PVC conduit with required accessaries.
Primary light points
Secondary light points looped from the above point(maximum 4 points looped from one primary)
Supply & Installation of (26-32W) (2' X 2') full lit panel type LED Light fixture.,CRI >80,The fitting shall be suitable for grid / plain ceiling type & surface mounted / to be hanged from the ceiling at the height approved by architect. (CGL , PHILIPS WIPRO , GE or equivalent category & model as approved by client / architect / consultant.)
PA System
SITC of Speaker wire(copper) (through new PVC conduit) from amplifier upto speaker .Rate shall be inclusive of new heavy gauge 25 mm PVC conduit with required accessaries.
SITC OF Speaker 15 watt of Ceiling mounted type ( make- AHUJA/BOSCH or equivalent make as approved by client)
Supply, Installation & Testing of Amplifier ,120 watt,for Canteen area Address System suitable to operate on 230V A.C. / 12V D.C. supply with two low impedence microphone input, tone control, protection circuit complete for the speakers output lines,USB port,etc. (Ahuja / approved equivalent make) Technical required specifications 1)Mic & Aux Inputs. 2)Built-in MP3 player with remote control for USB, SD/MMC card reader. 3)Line output for connecting to a Booster Amplifier and Preamplifier Output for recording the programme. 4)Cut and Boost type Bass & Treble controls. 5) LED array for output level monitoring.
FIRE ALARM SYSTEMS
Supply, installation, testing and commissioning of Response indicator for all existing detectors located above false ceiling (The above ceiling detectors are already installed.The integration of RI with detector and existing repeater/ main fire panel is in vendor scope).
SITC OF FRLS Fire CABLE 2 X 1.5 Cu armoured cable
One coat Painting ( Fire red colour) to already installed Fire fighting sprinkler system G.I. pipes confirming to IS 1239 Pt -I heavy grade.
32mm nominal dia
25mm nominal dia
The above quoted prices are including freight, insurance, loading, un-loading, handling and allied charges to be incurred till installation at site.
BBP Electricals
Shree Venkateshwara Turnkey Project Solution Pvt Ltd
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .