| 1 | L1₹12.5 LAccepted-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L1 | Accepted-AOC Meeting Eligibility Criteria | |
| 2 | L2₹15.0 L+₹2.1 L (16.3%)Rejected-AOC GROUND BALURGHAT COMPOUND NEAR TRIPURA ROAD KHANAPARA ROAD GUWAHATI KAMRUP METROPOLITAN ASSAM 781029 | KAMRUP METRO | ASSAM | 781029 | L2 | Rejected-AOC Not Meeting Eligibility Criteria | |
| 3 | L3₹15.7 L+₹2.8 L (21.5%)Rejected-AOC | L3 | Rejected-AOC Not Meeting Eligibility Criteria | |
| 4 | L4₹16.0 L+₹3.1 L (23.8%)Rejected-AOC | L4 | Rejected-AOC Not Meeting Eligibility Criteria | |
| 5 | L5₹16.2 L+₹3.3 L (25.7%)Rejected-AOC 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L5 | Rejected-AOC Not Meeting Eligibility Criteria |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
30 May 2020, 6:00 pmClosed
Garrison Engineer (P) Kanasar
Garrison Engineer (P) Kanasar, Kanasar Mil Stn
REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION, FITTINGS, FIXTURES AND REPAIR TO COOLING APPLIANCES AT KANASAR MILITARY STATION
2020_MES_342439_1
CANo GE(P)KNS-08/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
Kanasar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE(P) Kanasar
₹32,000
Yes
29 Jun 2020
4 May 2020
1 Jun 2020
4 May 2020
30 May 2020
18 May 2020
Amount
Taking down carefully existing unserviceable Copper/aluminum casing capping point wiring (light, fan, bell/buzzer, socket or power) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, pendents, sockets, lamp holders, shades, fan regulators, light fittings, bells etc (including old MS sunken boxes) and removing the retrieved materials from dismantling including making good the disturbed surface of walls, floors, ceilings etc to match with the adjoining work complete all as specified and as directed by the Engr-in-Charge.
M & L for Point wiring with stranded copper conductor cable, 1100 volts grade (ISI marked) PVC insulated and unsheathed of size 1.5 Sqmm single core in and including PVC casing capping with all fittings such as tees, bends etc terminating in MS sunken box covered with and including 3 mm thick new bakelite laminated sheet top cover ‘Hylam’ for one fan or light or exhaust fan or bell/buzzer point controlled by one switch, socket on independent board including 1.00 Sqmm PVC insulated unsheathed copper conductor cable, solid single core as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No 02 here-in-before but one bell point controlled by one bell push
All as per item No 02 here-in-before but socket point on the independent board with other switches
All as per item No 02 here-in-before but socket point on the same board with other switches
All as per item No 02 here-in-before but before but for one socket outlet 15 Amp with cable of 2.5 Sq mm on independent board including 1.5 Sqmm PVC insulated unsheathed copper conductor cable, solid single core as earth wire .
S & F for Switch piano flush type, Single pole 5 Amps, one way ISI marked, complete all as specified and as directed by Engineer-in-Charge
S & F for Bell push, flush type, Single pole 5 Amps, one way ISI marked, complete all as specified and as directed by Engineer-in-Charge
S & F for Call bell buzzer, AC, single pole, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S & F for Switch Socket outlet combination, flush type, 5 pin, 5 Amps, ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S & F for Switch Socket outlet combination, flush type, 3/5 pin, 5/15 Amps, ISI marked, complete all as specified and as directed by Engineer-in-Charge
S & F for Lamp holder PVC/poly carbonate body with back plate complete all as specified and as directed by Engineer-in-Charge.
S & F for Ceiling rose, 3 terminal PVC/ polycarbonate isolated body, ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement Sheet metal enclosure for distribution boards, suitable for fixing MCBs 240 volts with 200 amps rated bus bar, SPN, 08 ways, including making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement MCB suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 Amp complete all as specified complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 15 here-in-before but SPN
S & F fan regulator electronic step type, 230 Volt, including making holes in laminated bakelite sheet cover and connection complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement Switch piano flush type, Single pole 5 Amps, one way ISI marked, complete all as specified and as directed by Engineer-in-Charge
S & F in replacement Switch piano flush type, Single pole 15 Amps, one way ISI marked, complete all as specified and as directed by Engineer-in-Charge
S & F in replacement Socket outlet flush type, 5 pin, 5 Amps, ISI marked, complete all as specified and as directed by Engineer-in-Charge
S & F in replacement Socket outlet flush type, 3/5 pin, 5/15 Amps, ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement Bell push, flush type, 5 amps single pole complete all as specified and directed by Engineer-in-Charge.
S & F in replacement Call bell buzzer, AC, single pole, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement for Switch Socket outlet combination, flush type, 5 pin, 5 Amps, ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement for Switch Socket outlet combination, flush type, 3/5 pin, 5/15 Amps, ISI marked, complete all as specified and as directed by Engineer-in-Charge
S & F in replacement fan regulator electronic step type, 230 Volt, including making holes in laminated bakelite sheet cover and connection complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement sub main wiring with two single core cable PVC insulated unsheathed multi stranded copper conductor cable FRLS 4 Sq.mm, 1100 volts grade with one single core PVC insulated and unsheathed 2.5 Sq.mm multi stranded copper conductor cable FRLS for earth continuity connected to common earth dolly, in and including PVC casing & capping all as specified.. (Note :- two lengths of 4 sqmm cable and one length of 2.5 sqmm cable and one length of casing capping will be measured as one length)
Earthing complete with galvanized iron earth plate electrode of size 60cmx60cmx0.60cm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to and including the galvanized earth lead wire 4mm dia by means of GI bolts/nuts/washers , protected by 15mm bore GI light grade pipe from earth plate and upto 3m along pole fixed with 2 clamps made from mild steel flat iron 25x3mm bolts, nuts and washers etc. Earth plate shall be surrounded by packed layer of coal dust 300mm and common salt 15cm thick all around bottom and top. 20mm GI light grade pipe for watering and including funnel , wire mesh , RCC 1:2:4 type B-1 using 20 mm graded stone aggregate cover of size 30 cm X 30 cm X 8 cm thick reinforced with expanded metal weighing not less than 4Kg/Sqm, PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in earthing pit including necessary excavation and earth work, all as specified and shown in electrical plate No-4 of SSR part-I and connected to earthing point and testing on completion. (Note :- PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners) ( Rate inclusive disconnection of old/ existing earthing)
Supply and fix in repairs metal halide lamp 250 watt tubular thread type for light fitting as specified and as directed by Engineer-in-Charge. Make - Philips/Bajaj/CG
Supply and fix in repairs ballast copper wound metal halide 250 watts for light fitting as specified and as directed by Engineer-in-Charge. Make - Philips/Bajaj/CG
Supply and fix in repairs igniter suitable for 250 watts light fittings all as specified and as directed by Engineer-in-Charge. Make - Philips/Bajaj/CG
Supply and fix in repairs lamp holder porcelain thread type suitable for 250 watts lamps light fittings all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs capacitor 33 mfd manufactured for 250 Watts Metal Halide all as specified and as directed by Engineer-in-Charge. Make - Philips/Bajaj/CG
Supply and fix in repairs HRC fuse 6 Amps capacity existing type all as specified and as directed by Engineer-in-Charge. Make - Philips/Bajaj/CG
S & F in replacement of driver for security LED light suitable for 45 watt as per sample complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of driver for security LED light suitable for 90 watt as per sample complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches, in soft/loose soil not exc 1.5m depth and not exc 1.5m in width for repairs/ replacements/ laying of cables etc and getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in with the excavated soil including spreading, leveling, watering and well ramming in layers n.exc 25cm thick including making crown at the top of the trenches by watering etc all as specified and directed by Engineer-in-Charge.
Removing surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
M & L Protection to cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angles to the central axis of the cable using old size sub-class ‘B’ burnt clay bricks complete all as specified and as directed by Engineer-in-Charge.
M & L Sand cushioning and cover (using local tibba sand), 80 mm thick before laying of cable and 150 mm thick after the cable is laid, complete all as specified and as directed by Engineer-in-Charge. (Note: Approved local tibba dry sand after removal of vegetations, grass and other deleterious substances shall be used for sand cushioning and cover and punned thickness shall be measured & paid).
Supply & laying GI tubing light grade, ISI marked, for cable protection including fittings complete all as specified of size 40 mm bore all as specified and as directed by Engineer-in-Charge.
Supplying and laying in replacement LT underground cable, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable with aluminium conductor 1100 Volts grade , 185 Sqmm 3.5 core laid in trenches/ ducts/ fixed on pole/ wall/ laid under road/ path/ culvert/ drains/ encased in pipe Complete all as specified and directed by Engineer-in-Charge. (Excavation, earthwork, brick protection, sand cushioning shall be measured & paid separately. Removing of old bricks, cable is inclusive in unit rate quoted.)
All as per item No. 43.00 here-in-before but cable of size 70 Sqmm 3.5 core
All as per item No. 43.00 here-in-before but cable of size 50 Sqmm 3.5 core
All as per item No. 43.00 here-in-before but cable of size 35 Sqmm 3.5 core
All as per item No. 43.00 here-in-before but cable of size 25 Sqmm 3.5 core
All as per item No. 43.00 here-in-before but cable of size 10 Sqmm 4.5 core
Supply & fix in repairs for self ballasted LED batten Extruded thermoplastic body with PC diffuser in unique square shape for 4 feet long, 20 watt complete all as specified and directed by the Engineer-in-Charge. Make: - Polycab, cat part No LD00103031 or equivalent cat part of Bajaj/ Havells/ Philips/ Surya Roshni/ Crompton Greaves/ Havells.
Supply and fix in repairs performance energy efficient LED 40 Watt of size 1200x350mm surface mounting (for office use) with robust electronics complete all as specified and directed by the Engineer-in-Charge. Make:- Crompton Greaves Cat Part No - LCTLSN-40-CDL (1x4) or equivalent cat part of Bajaj/ Havells/ Philips/ Surya Roshni/ Polycab/ Havells.
Supply & fix in repairs Energy Efficient LED light 9 Watt of size 537mmx 22mmx 37mm for mirror light complete all as specified and directed by the Engineer-in-Charge. Make :- Havells Cat Part No- LHEXBTP7UN1W009 or equivalent cat part of Bajaj/ Havells/ Philips/ Surya Roshni/ Polycab/ Crompton Greaves.
Supply & fix in repairs LED light 36 watt 4 feet long Industrial luminaire with poly corbonate housing, alumminum gear tray duly prewired with inbuilt LED modules & accessories IP 65 protection complete all as specified and directed by the Engineer-in-Charge. Make:- Crompton Greaves Cat Part No- LPFC-36-CDL or equivalent cat part of Bajaj/ Havells/ Philips/ Surya Roshni/ Polycab/ Havells.
Supply & fix in repair for surface mounted LED 06 Watt flat panel, aluminum housing complete all as specified and directed Make:- CG Cat Part No- LCDSPL-S-06-CDL or equivalent cat part of Bajaj/ Havells/ Philips/ Surya Roshni/ Polycab/ Havells .
Supply & fix squere surface mounted LED 12 Watt flat panel, alumminum housing complete all as specified and directed by the Engineer-in-Charge. Make:- Crompton Greaves Cat Part No- LCDSPL-S-12-CDL or equivalent cat part of Bajaj/ Havells/ Philips/ Surya Roshni/ Polycab/ Havells.
REPAIR TO CEILING FANS/ EXHAUST FANS
Taking down and Dismantling of ceiling fan 1200mm/1400mm sweep of any make new/old model by opening the cover, separating down rod, rotor and stator assembly, locating the fault and making the fan fully in serviceable condition including replacing the defective worn out screws of the cover, split pin, oiling, and greasing etc. including repainting with synthetic enamel paint by spraying including filling cavities with filler, re-writing of MES No as of original size with stencil, including cleaning of the rating plate with the thinner complete all as specified and directed by Engineer-in-Charge. Note :- Rewindng and parts such as bushings, bearings, condensers, ‘D’ clamps with nuts, quarter pin and rubber seal, down rod, PVC canopies, flexible wire & shaft etc shall be measured and paid for separately under the respective items here-in- after
M & L for Re-winding motor of ceiling fan any make/model model size 1200mm sweep with super enameled copper winding wire of existing specification, gauge & weight conforming to IS including insulating material & varnishing the motor windings with good quality varnish complete all as specified and directed by Engineer-in-Charge. Make of winding wire: MILAN/ ATLAS/ CHETAK/ DEVIDAYAL
Supply for replacement of ball bearing of suitable size. Make: ''NBC/SKF conforming to IS
Supply for replacement of brass bush suitable for ceiling fan any make/model all as per original size/shape/type conforming to IS
Supply for replacement of shaft as per existing size and shape
M & L for Re-winding motor of ceiling fan any make/model model size 1400mm sweep with super enameled copper winding wire of existing specification, gauge & weight conforming to IS including insulating material & varnishing the motor windings with good quality varnish complete all as specified and directed by Engineer-in-Charge. Make of winding wire: MILAN/ ATLAS/ CHETAK/ DEVIDAYAL
Supply, fixing in replacement of ball bearing of suitable size. Make: ''NBC/SKF conforming to IS
Supply, fixing in replacement of brass bush suitable for ceiling fan any make/model all as per original size/shape/type conforming to IS
Supply, fixing in replacement of shaft as per existing size and shape
Dismantling of Exhaust fan 225 mm /300 mm /450 mm sweep of any make, opening the cover, separating the rotor and stator assembly, locating the fault and making the exhaust fan fully in serviceable condition including replacing the defective worn out screws, flexible wire of size 23/0.0076, oiling, greasing, reassembling the fan and testing complete to the satisfaction of the Engineer in Charge. Note : Rewinding and parts such as capacitors, blades and shaft etc. shall be measured and paid for separately under the respective items here-in- after
M & L for Re-winding of exhaust fan 300 mm sweep with super enameled copper winding wires of size 35/36 SWG or as per existing size of wire confirming to IS including varnishing the motor windings with good quality varnish complete all as specified and directed by Engineer-in-Charge. Make of winding wire: MILAN/ ATLAS/ CHETAK/ DEVIDAYAL
All as per serial item No. 66.00 here-in-before but of 450 mm sweep
All as per serial item No. 66.00 here-in-before but of 225 mm sweep
Supply, fixing in replacement of condenser 04 MFD including necessary connection. Make : 'Tibcon/Orient/Crompton Greaves/ Kawality conforming to IS
Supply, fixing in replacement down rod one foot long suitable for 1200/1400mm sweep of ceiling fan all as required at site complete all as specified and directed by Engineer-in-Charge
Supply, fixing in replacement down rod 3 feet long suitable for 1200/1400mm sweep of ceiling fan all as required at site complete all as specified and directed by Engineer-in-Charge
Supply, fixing in replacement 'D' clamp with nuts, check nuts, quarter pin and rubber reel suitable for 1200/1400mm sweep of ceiling fan all as required at site complete all as specified and directed by Engineer-in-Charge
Supply, fixing in replacement PVC Canopies (set of two) with steel screws as ordered or sample given by the Engineer-in-Charge
Supply, fixing in replacement condenser in replaceme 2.5 MFD conforming to IS including necessary connection complete all as specified and directed by Engineer-in-Charge. Make: 'Tibcon/Orient/ Crompton Greaves/ Kwality'
Preparation of old surfaces of the ceiling fan, any size or make and painting with synthetic enamel paint by spraying including filling cavities with filler, re-writing of existing MES No as of original size stencil and including cleaning of the rating plate with thinner complete all as directed by Engineer-in-Charge
Preparation of old surfaces of the exhaust fan, any size or make and painting with synthetic enamel paint by spraying including filling cavities with filler, re-writing of existing MES No as of original size stencil and including cleaning of the rating plate with thinner complete all as directed by Engineer-in-Charge.
REPAIR TO WATER COOLERS
Taking down unserviceable compressor including bushes, grommets sleeves, washers , mounting rubbers, nuts, bolts, terminal cover, brazing and clips from existing water coolers of any make and Supply and fixing new hermetically sealed unit (compressor) of the makes and model as specified including providing new bushes , grommets, sleeves, washers, mounting rubbers , nuts and bolts, terminal covers, brazing and clips in the existing water coolers of capacity 40/80 Litre of make Blue Star/Voltas with necessary accessories required for smooth functioning all as specified
All as per item No. 78.00 here-in-before but water coolers of capacity 60/120 Litre of make Blue Star/Voltas
All as per item No. 78.00 here-in-before but water coolers of capacity 150 Litre of make Blue Star/Voltas
Taking down carefully existing internal wiring of existing water coolers and in lieu providing new internal wiring with PVC insulated copper conductor wire of size 40/0.0076 sqmm including replacement of main lead 03 meter long ,terminal clips, thimbles, 03 pin plug top 15 amps & soldering extra complete all as specified. Make of wire- PARAGON/FINOLEX/ INCAB/ HAVELLS/PLAZA/ANCHOR'
Taking down carefully the following accessories/ parts from the existing water coolers and in lieu providing new accessories / parts in the same water coolers as per details given below
Filter copper.
Capillary tube of existing size of copper as per sample as approved by Engineer-in-Charge
PVC water outlet pipe 15 mm dia including clamps
Drain pipe of same quality, length and diameter as per existing
Condenser size 12” x 12” or 12” x 15”.
Cleaning of complete existing gas system with CTC solution, testing of leakage, charging of refrigerant with R-134 (a) upto desired pressure after rectification of leakage in existing water coolers complete all as specified and as directed by Engineer-in-Charge
Taking down defective Fan motor of capacity 1/16 HP, 230 volts, single phase from water coolers, dismantling the old burnt winding from the motor and rewinding with super enameled copper wire as per existing size including replacement of shaft, bushes mounting rubbers , nuts bolts and re-fixing after reassembling and testing in existing water coolersall as per directed by the Engineer-in-Charge. Make of winding wire: MILAN/ ATLAS/ CHETAK/ DEVIDAYAL. Note:- The unit rates quoted shall be deemed to be included replacement of minor spares such as rubbers, nuts, washers insulating materials and clamps
All as per item No. 89.00 here-in-before but Fan motors of capacity 1/35 HP, 230 volts, single phase
All as per item No. 89.00 here-in-before but Fan motors of capacity 1/10 HP, 230 volts, single phase
Supply & fixing in replacement blade of aluminium as per sample kept in AGE office for blower motor of water cooler (any make, model & capacity) complete all as specified & directed by the Engineer-in-Charge
Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/35 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified . Make of fan motor:-Shriram / Polor/ Cool Home/ Frac Master
Supply and fixing in repair push cock (Stainless steel) of existing make and specifications for water cooler
Supply and fixing in repair thermostat for water cooler Make :- Indfoss/ Whirlpool/ Electrolux
Supply and fixing in repair relay with OLP suitable for water cooler. Make : Annapurna/ Hitachi/ Whirpool/ Godrej
Supply and fixing in repair running capacitor 36 MFD. Make : Tibcon/Sharda/Epcos/ Testla/ Siemens
Supply and fixing in repair capacitor 10 MFD Make : Tibcon/Sharda/Epcos/ Testla/ Siemens
Supply and fixing in repair capacitor 15 MFD (Running) Make : Tibcon/Sharda/Epcos/ Testla/ Siemens
Supply and fixing in repair capacitor 40/60 MFD (starting) Make : Tibcon/Sharda/Epcos/ Testla/ Siemens
Supply and fixing in replacement Cable 3 core, copper conductor size 40/0.0076 for water cooler all as specified. Make of cable:- Plaza/ Finolex / Kalinga/ Havells
REPAIR TO AIR CONDITIONERS
Taking out the unserviceable compressor from the air conditioner window/split type 2 ton capacity of any make & type and supply and fixing in replacement same capacity reconditioned compressor obtained from the factory out let make Kirloskar/ Tecumseh/ Carrier (with two year guarantee), including soldering of copper pipe, cleaning the refrigerant system, condenser tubing by vacuumisation, cleaning the system by CTC solution, pressure testing of the system, charging of refrigerant gas with R- 134 (a) gas and compressor oil in the system to its rated capacity including checking of leakage, replacement of foundation rubber pads , nut and bolts, including testing on full load complete all as specified and as directed by Engineer-in-Charge
All as per serial item No 103.00 here in before but for window type A/C 1.5 Ton capacity of any make
Material and labour for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for de-moistureing the system and gas charging by R-134 (a) upto the required pressure for 1.5 ton window/ split type air conditioner complete all as specified and directed by Engineer-in-charge
All as per serial item No 105.00 here in before but for window / Split type A/C 2 Ton capacity of any make
Taking down of old unserviceable fan motor of any capacity from the window type/ split type Air Conditioners 1.5/2 TR capacity and dismantling old and unserviceable burnt winding wire and rewinding with super enameled copper wire of existing gauge and size including heat varnishes replacement of shaft, bearing and bush complete as found unserviceable after opening complete all as specified and as directed. Make of winding wire: MILAN/ ATLAS/ CHETAK/ DEVIDAYAL (The unit rates quoted shall be deemed to be included replacement of minor spares such as rubbers, nuts, washers insulating materials and clamps).
Removing of existing split type A/C 1.5/2.0 Ton capacity mounting , cleaning of evaporator and condenser with alkaline based solution, washing of AC, oiling of fan motor and Refixing on mounting , including Provn for making opening air tight and dust proof including testing and commissioning complete all as specified and directed by Engineer-in-charge
Supply and fixing in repair capacitor 45 MFD (Running) Make : Tibcon/Sharda/Epcos/ Testla/ Siemens
Supply and fixing in repair capacitor 50 MFD Make : Tibcon/Sharda/Epcos/ Testla/ Siemens
REPAIR TO REFRIGERATORS
Taking down unserviceable compressor including bushes, grommets sleeves, washers, mounting rubbers, nuts, bolts, terminal cover, brazing and clips from existing refrigerators of Make : Voltas / Whirlpool/ Kelvinator/ Zenith/ MEC capacity 165/180/310 ltrs compete all as directed
Supply and fixing new compressor obtained from manufacturer or authorised dealer of Voltas / Whirlpool/ Kelvinator/ Zenith/ MEC alongwith test certificate and with Two year guarantee card, commissioning and testing on full load of new compressor including supply and charging of refrigerant gas in the system its rated capacity and including replacement of copper filter single capillary bushes, grommets, sleeves , washers , mounting rubbers nuts and bolts, terminal covers, brazing and clips of existing make and capacity in the existing refrigerator for 310 ltrs capacity complete all as directed by Engineer - in – Charge
Cleaning of complete existing gas system with CTC, testing of leakage, charging of refrigerant with R-134 (a) after rectification of leakage in existing refrigerators of 165/180/310 ltrs capacity of make and model as per existing complete all as specified and as directed
Taking down carefully the following accessories/ parts from existing refrigerator of any make for 165/180/310 liters capacity and in lieu providing new accessories / parts as per existing in the same refrigerators as under :-
Evaporator for 310 liters refrigerators of any make
Filter suitable for 310 liters of any make.
Capillary tubes of existing sizes of copper as per sample approved by Engineer-in-Charge
Supply and fixing in replacement thermostat for refrigerator 310 Ltr capacity Make Indfoss
Supply and fixing in replacement relay for refrigerator 310 Ltr capacity Make : Godrej/ Hi- Tech
Supply for replacement Vegetable tray for refrigerator of 310 Ltrs capacity as per sample approved by Engineer-in-Charge
Taking down carefully the following parts from the existing AC and in lieu providing new accessories/parts as per existing as under
Contactor for split AC
PCB of AC split/ window (1.5/2.00/3.00 ton)
Starting relay for AC
REPAIR TO DESERT COOLERS
Removing of old paint complete with emery paper and cleaning with scrapper and preparation of internal surfaces & bottom of the desert coolers of any size and apply one coat of black bituminous paint complete all as specified
Removing of old paint complete with emery paper and cleaning with scrapper and preparation of external surfaces including steel grills, side panel etc of the desert coolers of any size applying one coat of synthetic enamel paint complete all as specified
Taking down carefully old unserviceable water pumps and in lieu providing new submersible type water pump heavy duty of capacity 1/70 HP , 230 volts 50 HZ single phase complete all as specified. Make :- Khaitan/Poler/Cool home
Taking down carefully fan motor from existing desert coolers and in lieu providing new fan motor kit 1/6 to 1/8 HP 230 volts 50 HZ including replacement of mounting legs complete all as specified and directed. Make : Khaitan/ Crompton Greaves
Taking down carefully fan motor 1/6 to 1/8 HP 230 volts, 50 HZ, from existing desert coolers and refixing the same fan motor after rewinding with super enameled copper wire of existing size complete including replacement of mounting legs complete all as specified and directed by Engineer-in-Charge. Make of copper wire : MILAN/ ATLAS/ CHETAK/ DEVIDAYA
Taking down the following parts from the existing desert coolers in lieu providing new parts as per existing as under :-
Capacitor for desert cooler 4 MFD 230 volts Make: Asian/ Tibcon/
PVC front grill including nuts bolts and washers suitable for 18/20” sweep desert coolers. Make Alka/Konark
Supply and fixing in replacement wood wool pads (set of three) weight not less than 500 gms superior quality complete all as directed by Engineer-in –Charge
Supply and fixing in replacement Supporting Jali for desert coolers ( set of three )
Supply and fixing in replacement Plug top, 3 pin, 5 Amps, 230 Volts, ISI marked, complete all as specified and as directed by Engineer-in-Charge. Make : Anchor/MDS/Leader/ LEGRAND/HAVELLS
Supply and fixing in replacement Fan blade size of aluminium for desert cooler as as per sample approved by Engineer-in-Charge
Supply and fixing in replacement of PVC flexible pipe 15 mm dia of superior quality heavy duty suitable for desert cooler of any capacity complete all as directed by Engineer-in –Charge
Supply and fixing in replacement ball brass valves, high pressure, with polythene float and fly-nut (PTMT) complete, screwed for iron pipe or brass ferrule , suitable for 15mm bore pipe complete all specified and as directed.Make Prayag/ Polytuf
REPAIR TO GEYSERS
Taking down and opening of the geysers 25/50 ltrs capacity storage type any make complete for inspection, descaling by chemical treatment of internal parts such as tank, base plate assembly (siphon system), heating element, etc re-assembling and refixing the same to its original position after testing on pressure complete all as directed by the Engineer-in-charge. Note:- Items such as glass wool, tank, siphon system, outer cover etc if found unserviceable under above item will be measured and paid for separately under its relevant item as supply only
S&F in replacement Thermostat switch ISI marked to Geysers 25/50 ltrs all as specified & directed by the Engineer-in-Charge. Make : Alert/Theta /Bajaj.
S&F in replacement siphon assembly suitable for Geysers 25 ltrs all as specified & directed by the Engineer-in-Charge.
S&F in replacement Low density polythene pipe (LDPE) connection arrangement with pipe of pressure rating 2.5 kgf/cm2 , 15 mm bore, 45 cm long with brass unions (Chromium plated) one on each side all as specified & directed by the Engineer-in-Charge.
S&F in replacement Plug and socket in sheet metal enclosure with 2 pin and earth plug and socket complete with and including MCB, SP, 20 Amps , 240 volts heavy duty all as specified.Make:-Legrand Cat Part 607851/ equivalent cat part No. in Hagger /L&T/ Standrad
S & F in replacement MCB suitable for 6 to 32 Amps, 240 Volt AC supply , SPN, with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge. Make:- Anchor/MDS/Leader/ LEGRAND/HAVELLS
S & F in replacement heating element ISI Marked of rating 1.5 KW capacity including washers for 25 ltrs capacity Geysers all as specified. Make :- THETA/ ALERT
S & F in replacement heating element ISI Marked of rating 2 KW capacity including washers for 50 ltrs capacity Geysers all as specified. Make :- THETA/ ALERT
Supply and fixing in replacement Plug top, 3 pin, 15 Amps, 230 Volts, ISI marked, complete all as specified and as directed by Engineer-in-Charge. Make:- Anchor/MDS/Leader/ LEGRAND/HAVELLS
Supply and fixing in repair release valve suitable for 15 mm bore of pipe for 25/ 50 ltrs capacity Geysers, ISI marked all as specified. Make :- Jindal/Prakash/ UNIK/KS.
Supplied and fixed in repairs bib taps cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule suitable for 15mm bore GI pipe complete all as specified and as directed by Engineer-in-Charge. Make :- JAQUAR/PRAYAG/SIEKO/PARKO/ HINDWARE/MARC
M/S SHREE SHYAM TRADERS
Aman Enterprises
Rasvinderpalandco
M/s Luxmi Constructions
Goyal Enterprises
M/s Kamal Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .