| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.9 LAccepted-AOC PLOT NO 25 SAICHARAN NAVIN BHIMASHANKAR COLONY BEED BYPASS CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | AURANGABAD | MAHARASHTRA | ₹35.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹41.7 LRejected-AOC | ₹41.7 L | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical UNITE NO 214 H WING UDYOG BHAVAN 2 NEAR ANAND NAGAR ADDL AMBERNATH MIDC AMBERNATH EAST 421506 | AMBERNATH | THANE | MAHARASHTRA | 421506 | - | - | Rejected-Technical Work Done Certificate Not as per NIT |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
12 Dec 2025, 11:00 amClosed
Superintending Engineer, MIDC Circle Office, CSN
Superintending Engineer, MIDC Circle Office, CSN
Annual Comprehensive Maintenance of pumping machinery, DG Set and allied work at various location at Waluj Industrial area
2025_MIDC_1255757_1
21/E/05
Open Tender
Electrical Works
CSN
Please refer Tender documents.
2 documents required · 2 mandatory
₹8,850
Yes
₹36,000
24 Feb 2026
4 Dec 2025
15 Dec 2025
4 Dec 2025
12 Dec 2025
5 Dec 2025
4 Dec 2025 - 5 Dec 2025
Amount
Supplying, erecting and testing of following Spares as and when required basis for 100 HP Aqua make effluent pump having Model no. ANS2052TYL100withrequired labours and tools at site etc complete as per detail specification. Cable Gland
(B)) Mech. Seal Set
(C)) Bearing Set
(D)) Motor rewinding
(E)) Ring Set
(F)) Fasteners
(G)) Overhauling
Supplying, erecting and testing of following Spares as and when required basis for 125 HP Aqua make effluent pump having model no. ANS2052 DXL125withrequiredlabours and tools at site etc complete as per detail specification (A)) Cable Gland
(B)) Mech. Seal Set
(C) ) Bearing Set
(D)) Motor rewinding
(E)) Ring set
(f) Fasteners
(G)) Overhauling
Supplying, erecting and testing of following Spares as and when required basis for Aqua make effluent pump having model no.ANS 1233 SM035withrequiredlabours and tools at site etc complete as per detail specification (A)) Cable Gland
(B)) Mech. Seal Set
(C)) Bearing Set
(D)) Motor rewinding
(E)) Ring Set
(F)) Fasteners
(G)) Overhauling
Supplying, erecting and testing of following Spares as and when basis required for Aqua make effluent pump having model no.ANS 1027 DM020withrequiredlabours and tools at site etc complete as per detail specification. (A)) Cable Gland
(B)) Mech. Seal Set
(C)) Bearing Set
(D)) Motor rewinding
(F)) Ring set
(G)) Fasteners
(G)) Overhauling
Carrying out Servicing of DG set up to 50 kVA with/without AMF Panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, Carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, Examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with Distilled water, Checking V belts with necessary adjustment, Checking and retightening of nut bolts including coupling bolts of engine and alternator, Checking & cleaning of radiator and leakage testing Checking of radiator & fuel supply hose pipes, Checking of AVR, excitation diodes, its connections confirming proper output voltage. Checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator, Attending breakdowns as and when required during One month period or during VIP visit within 2 hours of intimation and Submit the servicing report to engineer in charge.(Non Comprehensive) as per specification No. GEN-SER-AMC
Carrying out Servicing of DG set from 62.5 kVA to 200 kVA with/without AMF Panel of any make to ensure smooth running of DG set for 30 mins Checking for abnormal sound and leakages, Carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, Examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with Distilled water, Checking V belts with necessary adjustment, Checking and retightening of nut bolts including coupling bolts of engine and alternator, Checking & cleaning of radiator and leakage testing Checking of radiator & fuel supply hose pipes, Checking of AVR, excitation diodes, its connections confirming proper output voltage. Checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator, Attending breakdowns as and when required during One month period or during VIP visit within 2 hours of intimation and Submit the servicing report to engineer in charge.(Non Comprehensive) as per specification No. GEN-SER-AMC
Carrying out Servicing of DG set from 250 kVA to 500 kVA with/without AMF Panel of any make to ensure smooth running of DG set for 30 mins. Checking for abnormal sound and leakages, Carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, Examine battery charging with monitoring system and recording Voltages, checking battery cells gravity and topping up with Distilled water, Checking V belts with necessary adjustment, Checking and retightening of nut bolts including coupling bolts of engine and alternator, Checking & cleaning of radiator and leakage testing Checking of radiator & fuel supply hose pipes, Checking of AVR, excitation diodes, its connections confirming proper output voltage. Checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator, Attending breakdowns as and when required during One month period or during VIP visit within 2 hours of intimation and Submit the servicing report to engineer in charge.(Non Comprehensive) as per specification No. GEN-SER-AMC
Providing Servicing Kit for 50 KVA to 250 KVA DGS et i.e, Oil Filter, Air Filter Air cleaner , Lub oil Filter , fuel filter , all required Contactor , V-Belt ,etc Complete
Complete servicing of existing LBS including oiling and Greasing of LBS mechanism, interlock checking complete wiring check and give satisfactory testing. HT HRC Fuse
Arc Chute
Driver Insulator
Support Insulator
Fuse Trip Shaft.
Comprehensive maintenance of 2MT /3 MT EOT at various locations byr eplacing of shoe pad , oiling and greasing of wire rope ,geared motor , limit switch control panel servicing ,forward/reverse motor servicing, replacement of worn out and damaged parts , motor winding if required and keeping the EOT in working condition etc complete
Comprehensive maintenance of APFC panel / LT panel to maintain the power factor up to unity including required contractor, timer, required capacitors bank LED switch ,R/Y/B indicator tools and manpower etc complete .If agency fail to maintain monthly PF above 0.98 , the appropriate amount will be deducted from bill .
Providing & erecting 3 Pole MCCB, 415V, up to 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB
Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB
Supplying, erecting, testing & commisioning 525 V 3 phase, 50 Hz., MPP type capacitor having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours kVAr bank of metalised polypropylene condensers (MPP) with the standard capacities of 2, 3, 5, 7, 10, 12.5 and 15 kVAr units of P.F. correction for operation on 3 phase 50 Hz. with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licensee.
Filtration of transformer oil conforming to IS 1886 : 2000 on site till satisfactory test results.
Supplying and topping up new insulating oil for transformer conforming to IS 335 :1993 of approved make with test certificate.
Supplying and erecting 12 V/100Ah Tubular battery with battery terminal wire, duly charged complete with 36 months warranty complete
Supplying and erecting 12 V/130Ah to 135Ah Tubular battery with battery terminal wire, duly charged complete with 36 months warranty complete
Supplying and erecting 12 V/180Ah Tubular battery with battery terminal wire, duly charged complete with 36 months warranty complete
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and erecting integrated LED street light fitting 85-90W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 9300 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG-ODF/SL.
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete.
Supplying, installing, testing and, commissioning of 11kV630A , 20KA outdoor AIS (1+2) VCB switchboard Panel with Aluminium busbar , necessary indications and transformer protection complete erected on provided CC foundation etc. as per specification.
Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B-7, Page No. 38 1) In PCC M-100
Supplying and erecting fencing of section having size at least 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete with provided earthing as per specification no. SS-AS/FSG
Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2.45m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete.
Supplying and erecting double leaf hinged door each 1500 mm in width x 2450 mm in height using B class GI pipe, hinges and angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation and painted complete as per specification no SS-AS/DLD
Supplying and spreading stone metal 25mm size for 100mm depth above the ground level complete.
Anush Electricals Aurangabad (BID ID -7092488)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.