Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹31,000
Closing Date
5 Jan 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Director, NIOT
Velachery to Tambaram main road, Narayanapuram, Chennai - 600100
Electrical work for 60kVA UPS Power in MB/FF/RW/CMC Store room at NIOT Campus
2022_NIOT_730630_1
NIOT/SnP/EnM/29629/2022-23
Open Tender
Electrical Works
Works
NIOT CAMPUS, CHENNAI
4 documents required · 4 mandatory
₹0
₹31,000
Yes
5 Jan 2023
21 Dec 2022
5 Jan 2023
21 Dec 2022
5 Jan 2023
21 Dec 2022
21 Dec 2022 - 4 Jan 2023
Amount
Supply and laying of 3.5C x 70sqmm XLPE insulated Aluminium armoured 1.1kV graded UG cable.along the closed cable trunch/Hump Pipe as required. Location: * Utility-I/FF/section-III/400A spare feeder to Utility-I/FF/UPS Main Panel.(2Runs 3.5C x 70sqmm) * Utility-I/FF/UPS Main Panel 200A feeder to MB/GF/LW/Panel room new UPS sub panel incomer.(1Run 3.5C x 70sqmm) Make: polycab/RR kabel/KEI
Supply and Making of end termination with single compression Gland (3.5C x 70sqmm) suitable crimping lugs.The gland should be double earthed by suitable copper wire and earth strip. Location: * Utility-I/FF/section-III/400A spare feeder - 2nos. * Utility-I/FF/UPS Main Panel- 3nos. * MB/GF/LW/Panel room/UPS Main panel - 1no. Make: Comet / Comex
Supply and laying of 3.5C x 50sqmm XLPE insulated Aluminium armoured 1.1kV graded UG cable.along the wall/cable tray/above false ceiling as required. Location: MB/GF/LW/Panel room new UPS sub panel 200A feeder to MB/FF/RW/CMC store room 60kVA UPS Incomer panel. Make: polycab/RR kabel/KEI
Supply and Making of end termination with single compression Gland (3.5C x 50sqmm) suitable crimping lugs.The gland should be double earthed by suitable copper wire and earth strip. Location: * MB/GF/LW/Panel room new UPS sub panel - 1no. * 60kVA UPS Incomer panel - 1no. Make: Comet / Comex
Supply and laying of end termination of 5Rx35sqmm (3Runs for 3phase & 2Runs for UPS neutral) FRLS PVC insulated copper conductor graded to 1.1kV ,single core multistrand cable in existing hose of size 2" along the wall as required as per site condition.The job including of providing of suitable copper lugs. Location : * Incomer panel to Isolation transformer. * Isolation transformer to 60kVA UPS. * 60kVA UPS to Outgoing panel. Make : polycab/KEI/Kundan / RR
Supply and laying of 2" rainforced PVC hose.The job includes of PVC gland also. Location :MB/FF/RW/CMC Store room Make : Any ISI brand
Supply and laying of 1¼" dia heavy PVC conduit along the wall.The job includes suitable bends,JB,special clamps cable tie and accessories etc. Make : Avon plast / Bajaj plast /MODI /SUN Location : Earth bit to MB/FF/CMC store room
Supply,laying and end termination of 2R x 50sqmm FRLS PVC insulated copper conductor graded to 1.1kV ,single core multistrand cable in existing 1¼" size PVC Conduit along the wall as required as per site condition.The job including of providing of suitable copper lugs. Location : * Incomer panel to Isolation transformer. * Isolation transformer to 60kVA UPS. * 60kVA UPS to Outgoing panel. Make : polycab/KEI/Kundan / RR
Supply and fixing of 25mm x 5mm copper bus along the wall.The job including of making holes and providing of SS bolt,nut & washers.(UPS Earth & Neutral) Location: MB/FF/CMC store room
Supply,laying and end termination of 4Rx16sqmm & 2Rx6sqmm FRLS PVC insulated copper conductor graded to 1.1kV ,single core multistrand cable in existing 1¼" size PVC Conduit along the wall as required as per site condition.The job including of providing of suitable copper lugs. Location: * UPS outgoing panel 63A MCCB feeder to existing 8way VTPN DB. * UPS outgoing panel 63A MCCB feeder to 63A COS. Make: polycab/RR kabel/KEI
Supply,fixing,testing and commissioning of 63A 4P onload change over switch with Metal Enclosure along the wall. Make : * COS - L&T / Siemens / GE / Hager * Encloser-L&T/GE/Hager/Fabricated Location: MB/FF/CMC store room
Supply and Laying of 3C x 4 sqmm XLPE insulated copper armoured cable graded to 1.1kV in existing wall/surface / above false ceiling. (For A/C Incomer & Outgoing) Location : * MB/FF/LW/Old xerox room LDB VTPN to MB/FF/RW/CMC store room A/C timer box. Make : Polycab/RR kabel/KEI
Supply and fixing of end termination with single compression Flame proof gland (3C x 4sqmm) suitable crimping lugs.The gland should be double earthed by suitable copper wire or strip. Location : * MB/FF/LW/Old xerox room LDB VTPN - 1no. * MB/FF/RW/CMC store room A/C timer box - 1no. Make: Comet / Comex
Supply,laying and end termination of 3C x 4 sqmm PVC insulated copper unarmoured flexible cable graded to 1.1kV in existing wall/surface/above false ceiling.The job including of providing of suitable copper lugs & suitable PVC gland. (For A/C Outgoing) Location : MB/FF/RW/CMC store room A/C timer box to A/C I & II indoor or outdoor units. Make : Polycab/RR kabel/KEI
Supply and laying of 1" PVC Conduit along the wall/above false ceiling with complete fixing accessories. (For A/C wiring) Location: MB/FF/RW/CMC store room Make : MODI/SUN/Avon plast/Bajaj plast
Supply and laying of 1" Steel reinforced hose along the false ceiling .The job includes providing of cable tie and accessories. Location :MB/FF/RW/CMC store room
Supply and fixing of 4module PVC surface mount box comprising of following accessories along the wall. a) 4Module plate - 1no b) 15A switch - 1no c) 15A multipin socket - 1no (3 module) d) 15A Plugtop - 1no. Location : MB/FF/RW/CMC store room Make : MK / Anchor roma
Supply and fixing of IP65 weather proof 4way Thermo plastic box with C16A DP MCB alone the wall. (Dummy plate - 2nos) (Control for outdoor unit) Make :- *MCB - Legrand/Hager *Box - Hensel / Sintex Location: MB/FF/RW/CMC store room.
Supply, Erection, Testing and Commissioning of indoor type UPS Main Panel,Floor mounting type,dust and vermin proof,constructed of 14SWG CRCA sheets,compartmentalised,modular type and powder coated as per specification below. Incomer :- 1) 400A 4P 50kA MCCB - 1no 2) Current transformer rated 400/5A,10VA/CI 1.0 meter - 3no's. 3) Digital Multi data Meter - 1no. 4) LED type RYB indication lamps with control fuses - 1set. Outgoing :- 1) 200A 4P 36kA MCCB - 1no. 2) 100A 4P 36kA MCCB - 5no's. 2) One set 600A TPN 50kA for 1sec Copper Bus Bars with colour coded heat shrinkable PVC sleeves,DMC/SMC bus bar supports and suitable earth bus and accessories as required as per the TNEB norms. Note :- 1) All breakers should have shunt release arrangement. 2) All breakers should be with rotary handle mechanism. 3) The size of the outgoing compartment for 200A & 100A shall not be less than that for 200A. 4) Each outgoing compartment size shall be designed for accommodating enhanced instrumentation in future. Make:- 1) Panel board - CPRI Fabricators 2) MCCB - L&T / GE / SIEMENS (D-shine model) 3) CT - KAPPA / L&T 4) METER - KRYKARD / L&T 5) LED INDICATOR - TEKNIP/L&T/SIEMENS Location: Utility-I/FF/MV panel room.
Supply, Erection, Testing and Commissioning of indoor type UPS Sub Panel,Floor/wall mounting type,dust and vermin proof,constructed of 14SWG CRCA sheets,compartmentalised,modular type and powder coated as per specification below. Incomer :- 1) 200A 4P 50kA MCCB - 1no 2) Current transformer rated 400/5A,10VA/CI 1.0 meter - 3no's. 3) Digital Multi data Meter - 1no. 4) LED type RYB indication lamps with control fuses - 1set. Outgoing :- 1) 200A 4P 36kA MCCB - 1no. 2) 100A 4P 36kA MCCB - 3no's. 3) 63A 4P 36kA MCCB - 2no's 4) One set 400A TPN 50kA for 1sec Copper Bus Bars with colour coded heat shrinkable PVC sleeves,DMC/SMC bus bar supports and suitable earth bus and accessories as required as per the TNEB norms. Note :- 1) All breakers should have shunt release arrangement. 2) All breakers should be with rotary handle mechanism. 3) The size of the outgoing compartment for 200A & 100A shall not be less than that for 200A. 4) Each outgoing compartment size shall be designed for accommodating enhanced instrumentation in future. Make:- 1) Panel board - CPRI Fabricators 2) MCCB - L&T / GE / SIEMENS (D-shine model 3) CT - KAPPA / L&T 4) METER - KRYKARD / L&T 5) LED INDICATOR - TEKNIP/L&T/SIEMENS Location: MB/GF/LW/Panel room.
Supply,Erection,Testing and Commissioning of indoor type 60kVA UPS Incomer Panel,wall mounting type,dust and vermin proof,constructed of 14SWG CRCA sheets,compartmentalised,modular type and powder coated as per specification below. Incomer :- 1) 200A 4P 50kA MCCB - 1no 2) Current transformer rated 200/5A,10VA/CI 1.0 meter - 3no's. 3) Digital Multi data Meter - 1no. 4) LED type RYB indication lamps with control fuses - 1set. Outgoing :- 1) 125A 4P 36kA MCCB - 2nos. 2) One set 200A TPN 50kA for 1sec copper Bus Bars with colour coded heat shrinkable PVC sleeves,DMC/SMC bus bar supports and suitable earth bus and accessories as required as per the TNEB norms. Note :- 1) All breakers should have shunt release arrangement. 2) All breakers should be with rotary handle mechanism. 3) The size of the outgoing compartment for 125A shall not be less than that for 200A. 4) Each outgoing compartment size shall be designed for accommodating enhanced instrumentation in future. Make:- 1) Panel board - CPRI Fabricators 2) MCCB - L&T / GE / SIEMENS (D-shine model 3) CT - KAPPA / L&T 4) METER - KRYKARD / L&T 5) LED INDICATOR - TEKNIP/L&T/SIEMENS Location: MB/FF/RW/60kVA UPS room(CMC store room).
Supply,Erection,Testing and Commissioning of indoor type 60kVA UPS Outgoing Panel,wall mounting type,dust and vermin proof,constructed of 14SWG CRCA sheets,compartmentalised,modular type and powder coated as per specification below. Incomer :- 1) 200A 4P 50kA MCCB - 1no 2) Current transformer rated 200/5A,10VA/CI 1.0 meter - 3no's. 3) Digital Multi data Meter - 1no. 4) LED type RYB indication lamps with control fuses - 1set. Outgoing :- 1) 63A 4P 36kA MCCB - 2nos. 2) 40A 4P 36kA MCCB - 2nos. 2) One set 200A TPN 50kA for 1sec copper Bus Bars with colour coded heat shrinkable PVC sleeves,DMC/SMC bus bar supports and suitable earth bus and accessories as required as per the TNEB norms. Note :- 1) All breakers should have shunt release arrangement. 2) All breakers should be with rotary handle mechanism. 3) The size of the outgoing compartment for 63A shall not be less than that for 125A. 4) Each outgoing compartment size shall be designed for accommodating enhanced instrumentation in future. Make:- 1) Panel board - CPRI Fabricators 2) MCCB - L&T / GE / SIEMENS (D-shine model 3) CT - KAPPA / L&T 4) METER - KRYKARD / L&T 5) LED INDICATOR - TEKNIP/L&T/SIEMENS Location: MB/FF/RW/60kVA UPS room(CMC store room).
AADHI ELECTRICAL AND CONSTRUCTION
POWERTECH ENTERPRISES
Nexus India Info Systems/V.Kanagaraj
Akshaya Associates
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .