Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹94.4 LAccepted-AOC NO 5D AGILA NAGAR 5TH CROSS EXTENSION GANAPATHY NAGAR SOUTH EXTENSION THIRUVANAIKOVIL TRICHY 5 | TRICHY | TRICHY | TAMIL NADU | L1 | Accepted-AOC L1 Admit | |
| 2 | L2₹97.8 L+₹3.4 L (3.60%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹98.7 L+₹4.3 L (4.60%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
₹94.4 L
EMD Value
₹94,365
Closing Date
12 Jul 2023, 3:00 pmClosed
commissioner madurai corporation
Aringar Anna Maligai
Removing existing Paver block surface Irulappan samy kovil cross street, Irulappasamy kovil colony, Ayyasamy street, Irulappasamy samy 2nd, 3rd , 4th street, Thandalkaranpatti 2nd street, Kasthuri Orran Street, Thirisulakaliyamman kovil street in war
2023_MAWS_336499_1
E8 / Est.No.006984 (NCAP, 15th CFC)/22-23
Open Tender
Civil Works
Lump-sum
60 days
Madurai
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹94,365
17 Aug 2023
6 Jul 2023
12 Jul 2023
6 Jul 2023
12 Jul 2023
6 Jul 2023
Amount
Removing Existing Paver Block surface etc
ReFixing of Existing Removed Paver blockM40grade 80mmthick&60mm thick inuniform shape of approved make to be laid influrring bone pattern withst one dust cushion below the uniform shape of approved nonskitting surface in the to pandn the rate including levelling the base preparation of paver sassubbase ,stone dust cushion150mmthick laying out of pavement cut the pieces to fix theed gevibring the pavers,sweeping tranporting, loading,unloading of laying,paverblock as per standard specification,.
Providing and laying,spreading and compacting 0.396m 3of4522.40mm &0.528m3of22.40-2.36mm & 0.396m 3of2.36mm and below metal graded stone aggregate to wetmix macadam(WMM)specification including premixing the material with water at OMCinmechanical mixplant carriage to mixed material by tipper to site laying inuniformlayers with paver insubbase/base course on well prepared surface and compacting with vibratory roller to achive the desireddensity complete asper clasue 406 of MORTH specifications.
Supplying and laying Rubberised interlocking Paver blockM40 grade Providing and laying 80mm thick high strength type conforming IS 15658-2007 of Rubberised interlocking paver block in size of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in herring bonepattern with quarry rubbies cushion below the uniform shap of approved non sticking surface in top and the rate is including levelling the base preparation at paver as sub base, quarry rubbies cushion 150mm thick laying out of pavement cut the pies of fix the edge vibrating the pavers, sweeping transporting loading and unloading and laying of paver block as per standard specification etc.,
Raising the existing circular manholes in heavy type including removing the existing manhole cover with frame by dismantling the existing cement concrete and tar road surface alround the manhole raising the manhole with cement concrete 1:2:4 (one cement two sand and four aggregates ) 25 cm height including centering inside the manhole raising ,laying 15 cm tk cement concrete 1:2:4 with 20mm granite chips including finishing the top surface of manhole alround etc., complete.,
Manufacturing, supply & fixing of Retro-Reflective Road name sign board single arrow size 1.0x0.5m size made out if wide angle cuble corner micro prismatic grade sheeting confirming to IRC 67:2010& Type XI standards of ASTM D 4956-09 specifications and fixed over 2mm thick aluminium sheet back support frame of stainless steel supported by 32 NB stainless steel pipe all around and 65NB pipe vertical post firmly fixed to the ground by means of property designed foundation with M15 grade cement concrete 30cmx30cmx45c mets complete. The information message shall be made out of cut out letters in Blue color transparent overlay film as per IRC 67-201 Guidelines, 7 years pre qualification warranty for Retro Reflective sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor. The sign board shall be Retro-Reflective type XI. The Retro - Reflective sheeting should have manufacturers WATERMARK on the sheeting surface for identification and the reflective sheeting should be orientation free. This should be compulsorily be demonstrable.
Add GST 18%
C SIVAKUMAR
C SATHIASEELAN
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .