Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-Finance | ₹10.9 L | L1 | Accepted-Finance Accepted |
| 2 | L2₹11.3 L+₹42,456.67 (3.89%)Accepted-Finance CC 1 BOOTH NO 8 JANTA BHAWAN ROAD SIRSA SIRSA HARYANA 125055 | SIRSA | HARYANA | 125055 | ₹11.3 L+₹42,456.67 (3.89%) | L2 | Accepted-Finance Accepted |
| 3 | L3₹11.9 L+₹1.0 L (9.27%)Accepted-Finance | ₹11.9 L+₹1.0 L (9.27%) | L3 | Accepted-Finance Accepted |
| 4 | L4₹12.3 L+₹1.4 L (12.5%)Accepted-Finance HOUSE NO 95 B STREET NO 13 VILLAGE WAZIRABAD NEW DELHI 110084 | NORTH | DELHI | 110084 | ₹12.3 L+₹1.4 L (12.5%) | L4 | Accepted-Finance Accepted |
| 5 | L5₹13.5 L+₹2.6 L (23.6%)Accepted-Finance | ₹13.5 L+₹2.6 L (23.6%) | L5 | Accepted-Finance Accepted |
Tender Value
₹16.8 L
EMD Value
₹33,696
Closing Date
2 May 2026, 3:00 pmClosed
Executive Engineer (E)
O/o EE (E), HPED, PWD, Yamuna Western Bank, Lok Nayak Setu, ITO, New Delhi-02
RMO of various E and M Services at 100 bedded LBS Hospital Khichripur Delhi SH Supplying and replacement of faulty Fire Fighting Fire Alarm and PA System item at LBSH
2026_PWD_290407_1
03/EE(E)/HPED/PWD/2026-27
Open Tender
Electrical Works
Percentage
30 days
Lal Bahadur Shastri Hospital, Khichripur
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹33,696
Yes
30 May 2026
25 Apr 2026
2 May 2026
25 Apr 2026
2 May 2026
25 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
(a) 100 mm dia | 50 | Mtr. | - | - |
| 2 | (b) 150 mm dia | 20 | Mtr. | - | - |
| 3 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
(a) 150 mm dia | 2 | Nos. | - | - |
| 4 | Supplying, fixing, testing and commissioning of Hose box (Double Door) (900mm x 600mm x 500mm) 16 gauge which is suitable for 2 no. 15mtr. Hose and 1 no short branch pipe and 1 no hydrant and painting with two or more coats of synthetic enamel paint of required shade completes as required. | 6 | Nos. | 8,122 | ₹48,732 |
| 5 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. | 150 | Nos. | - | - |
| 6 | Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. | 30 | Nos. | - | - |
| 7 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. | 20 | Nos. | - | - |
| 8 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. | 1,000 | Mtr. | - | - |
| 9 | Supplying, Replacement, Installation, Testing and Commissioning of Main Fire Alarm Control Panel made out of 16 SWG MS Sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, public address system, monitoring system including connections, interconnections. 24 Zone Microprocessor Based Fire Alarm Control Panel, having provision of each zone address/location programming via key pad , each zone power isolation & loop voltage cut-off facility, Minimum 999 event data logging storage, High resolution LCD display. Incorporated Software controlled. Having C/NC/NO potential free relay control for FIRE, OPEN & SHORT. Walk test facility and open Communication port., Heavy duty power supply of 230V AC and frequency of 50 Hz 6 Amp 24volt DC separate output for battery charger all the feature accommodates in single wall mount double door with locking arrangement cabinet, complete in all respect as per IS-2189-2008 features as required. extra space for further features up gradation’s construction like signal relay and i/o ADC sensor output extra space for modules as per your site requirement.
250 Watt PA Amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories -2 Nos. (one to act as standby).
Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set.
Announcement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. complete as required -1 set.
Amplifier change over switch for inter changing amplifier - 1 No.
Monitor Panel for loudspeaker complete with output selector, ON/OFF switch, fuse, visual indications etc. complete as required -1 No.
Dynamic microphone with stand and ON/OFF switch- 1 No. Main ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters, terminal blocks etc. complete as required -1 set.
Main ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters, terminal blocks etc, complete as required - 1 sets. Battery charger
trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing space for 2 nos.12 volt, 60 AH each sealed maintenance free batteries -1 set (with battery). | 1 | Set | 3,29,266 | ₹3,29,266 |
| 10 | Supplying, Replacement, Installation, Testing and Commissioning of 8 Zone sector panel, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. | 7 | Nos. | 12,263 | ₹85,841 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 9.52 MB
BOQ_385444.xls
BOQ • 0.31 MB
corrigendum.pdf
PDF • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .