| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹35.0 L+₹3.3 L (10.3%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹35.2 L+₹3.5 L (11.1%)Rejected-Finance AKULA STREET BHAPUR BAZAR BERHAMPUR DISTT GANJAM ODISHA 760001 | GANJAM | ODISHA | 760001 | L3 | Rejected-Finance 3RD LOWEST | |
| 4 | L4₹35.6 L+₹3.9 L (12.3%)Rejected-Finance | L4 | Rejected-Finance 4TH LOWEST | |
| 5 | L5₹36.0 L+₹4.3 L (13.6%)Rejected-Finance | L5 | Rejected-Finance 5TH LOWEST |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
18 Nov 2020, 6:00 pmClosed
R S SHUKLA EE
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIRS TO TOILET SLAB SUNKEN FLOOR WATER PROOFING TREATMENT ROOF TREATMENT PLUMBING SANITARY FITTINGS RAIN WATER PIPES ETC OF BLDGS IN ZONE A AT GMS
2020_MES_390394_1
8000/68/20-21/0969/E8
Open Tender
Civil Works
Item Rate
270 days
GOPALPUR MILITARY STATION
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹56,000
Yes
27 Nov 2020
27 Oct 2020
20 Nov 2020
27 Oct 2020
18 Nov 2020
10 Nov 2020
Amount
Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for complete all as specified & directed.
M&L for removing demolished material exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified.
M&L for Cleaning the concerned RCC surface by means of wire brush to expose the concrete surface which should be free from all loose particles, dust, laitance, etc complete all as specified.
M&L for Making corner fillets with Polymer modified cementitious (PMC) mortar (PMC:C:M :: 1:2:4 by weight) at all joints of horizontal and vertical surface and doing bore packing with PMC mortar complete all as specified and directed.
M&L for the joints of pipes and concrete/masonry are to be sealed with epoxy putty or epoxy mortar (PMC:C :: 1:2 by weight) and the same is semi-rounded upto 5mm above surface level all along the periphery of PVC pipes complete all as specified and directed.
M&L for application of one coat of Acrylic Polymer Modified Cementitious (APMC) slurry (APMC:C :: 1:2 by weight) coating over the RCC slab surface and carried upto finished floor level on vertical portion (walls) complete all as specified and directed. (Note : This coat is allowed to get dry for 4-6 hours.)
M&L for application of one coat of Acrylic Polymer Modified Cementitious topping rendering (APMC:C:M :: 1:2:2) 1-1.5mm thick over the first coat Acrylic Polymer Modified Cementitious complete all as specified and directed. (Note : This coat is cured for 48 hours.)
M&L for rendering 15mm thick in CM 1:4 on brick or concrete surface, finishing even and smooth using extra cement incl Integral Waterproofing Compound (0.2 % or 100 ml per bag of cement) complete all as specified and directed.
M&L for PCC 1:3:6 using 40mm graded brick coarse aggregate as in sunken floors etc all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring 25 mm thick surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed.
M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment.
Taking down rain water pipe of any size or pattern incl all fitting head,shoe,band,swan neck etc complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed.
S&F 110mm bore PVC (SWR) couplers complete all as specified and directed.
S&F 110mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends any radius with access door complete all as specified and directed.
S&F 75mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed.
S&F 75mm bore PVC (SWR) couplers complete all as specified and directed.
S&F 75mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F in repairs PVC pipe 50 mm dia laid in floor/wall incl all fitting with joint sealed with pvc adhesive complete all as specified and directed.
S&F PVC stack clamps to walls or roof for 75 mm bore of pipe etc complete all as specified and directed.
S&F PVC stack clamps to walls or roof for 100 mm bore of pipe etc complete all as specified and directed.
S&F PVC (SWR) nahani/ floor trap, plain with grating with or without waste hole including jointing with solvent cement 75mm dia etc complete all as specified and directed.
S&F PVC (SWR) 'P' trap for 110 mm dia etc complete all as specified and directed.
S&F in repairs salt glazed stone ware gully trap, square or round of 150X150 square mouthed type "P" complete all as specified and directed.
S&F in repairs white vitreous china wash down water closet pan pedestal pattern (white) excluding fixing bolts, flushing cistern and flush pipe complete all as specified and as directed.
S&F in repair plastic water closet seat cover, Cream / white colour, closed pattern with flat bottom and cover and mild steel chromium plated aluminium hinging device for pedestral pattern WC complete all as specified and directed.
S&F in repair 10 Ltr capacity PVC valveless shyphonic action type low level flushing cistern white with inlet, ball valve, float valve and handle incl bracket and flush pipe of low level of 32mm dia fixed to wall complete.
S&F in repair chromium plated health faucet with 8mm dia and 1.2 m long flexible tubes and wall hook suitable for EWC including nut/washer complete all as specified and directed.
S&F in repair PVC connection 15mm dia size and 450 mm long with 2 Nos check nuts its washers complete all as specified and as directed.
S&F in repair bib tap 15 mm bore, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair angle cock 15 mm bore fancy type chromium plated, with capstan head, high pressure, screwed down, screwed for iron pipe or for brass ferrule fixed to iron pipe complete all as specified and directed.
S&F in repair CP two way angle valve with wall flanges 15 mm bore, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
Dismantling water tanks and removing to store of capacity exc 250 and n exc 500 ltrs complete all as specified and directed.
Dismantling water tanks and removing to store of capacity exc 500 and n exc 1000 ltrs complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks in white colour tripple layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I of 500 Ltr capacity complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks in white colour tripple layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I of 1000 Ltr capacity complete all as specified and directed.
S&F Ball valves 20mm dia high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gms) complete all as specified and directed.
S&F Ball valves for 25 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed.
S&F in repairs ball valves for 20 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed.
S&F in repairs ball valves for 25 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed.
S&F in repairs Gun metal, globe or gate valve with iron wheel head, 20 mm bore, screwed both ends for iron pipe complete all as specified and directed.
S&F in repairs Gun metal, globe or gate valve with iron wheel head, 25 mm bore, screwed both ends for iron pipe complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning for re-fixing of 15 mm dia complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store of 20 mm dia complete all as specified and directed.
Taking up or down 25 mm bore steel tubing and connections complete all as specified and directed.
Cutting chases in brick walls, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
S & F 15 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed.
S & F 20 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed.
S & F 25 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed.
Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:6 on fair faces of brick or concrete surface of wall and finished even and smooth with out using extra cement complete all as specified and directed.
M&L for rendering 5 mm thick in CM 1:3 on RCC ceiling surface and finished even and smooth with out using extra cement complete all as specified and directed .
M&L for preparation of newly plastered surfaces of walls and apply three coat of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces on ceilings and apply three coat of white wash complete all as specified and directed.
M&L for preparation of old decorated surfaces of walls and apply one coat of white wash complete all as specified and directed
M&L for preparation of old plastered surfaces of ceilings and apply one coat of white wash complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L Brick work with flyash bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Demolition of RCC of any description and in any position not other wise specially provided for reinforcement cut as required to facilitate demolition complete all as specified and directed.
M&L for Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:6 complete all as specified and directed. Note :- Reinforcement shall be measured and paid separately.
M&L for Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Providing water proofing treatment over cleaned roof surface with super thermo APP modified water proofing memberane comprising of the following for Non approachable roofs:- (i) Cleaning and sweeping and washing down with water to remove all dust etc from plastered roof surfaces / walls and filling of crack with sealing compound etc (ii) Bituminous based primer conforming to IS: 3384 – 1965 at 0.3 KG par Sq M (iii) One layer of super thermo APP modified water proofing memberane with non polyester reinforcement of any make.( M/s STP texsa ltd/Hyperplas memberane of M/S IWL India ltd/MS STP and Tikki Tar ltd). (iv) 3mm thick and minimum Weight @3.50Kg/Sqm, laid with gas torch and pasted on roof surfaces with roller. The over laps shall be sealed by flame including vertical surface after cutting necessary grooves and making good with PCC gola 1:2:4 type B-1 etc adhere to bitumen all as per manufactures instructions. (v) Applying one coat of aluminum paint @ 0.20 Kg / Sqm in two coats over bitumen layer as per manufacturer instruction . (application including sides lap, over laps shall be provided not less than 10 cm and loint seal with torch as per manufacturer's instructions specification and as per particular specification complete all as specified and directed.
M&L for PCC 1:2:4 type B0 (Using 12.50 mm graded stone aggregate) in roof padding/kerbs/sunken slab etc complete all as specified and directed.
M&L 10 mm thick rendering in CM 1:4 on external surfaces of walls & top surfaces of chajja / roof surfaces mixed with water proofing compound @ 3 % by the weight of cement surface finished even and smooth without using extra cement. (WPC shall be measured and paid seperately) complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
M/S K MURALIDHARA PATRA
Likitha Enterprises
M/s Ats Electricals
M/s MAA BHAIRABI ENTERPRISES
M/S SIWALIK AND CO
DHABALESWAR ENGINEERING WORKS
M/S JAGANNATH SASMAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .