Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.0 LAccepted-AOC 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L1 | Accepted-AOC L1 | |
| 2 | L2₹44.9 L+₹3.9 L (9.55%)Rejected-Finance 3 N K CHATTERJEE STREET KOLKATA 700 056 | KOLKATA | KOLKATA | WEST BENGAL | 700056 | L2 | Rejected-Finance Highest Amount Quoted | |
| 3 | L3₹46.5 L+₹5.5 L (13.4%)Rejected-Finance 27 A LELIN SARANI KOLKATA 700013 | KOLKATA | KOLKATA | WEST BENGAL | 700013 | L3 | Rejected-Finance Highest Amount Quoted |
Tender Value
Refer Docs
EMD Value
₹82,000
Closing Date
16 Mar 2021, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive_Engineer_PWD_Hooghly_Electrical_Division
Executive_Engineer_PWD_Hooghly_Electrical_Division
Arrangement_of_maintaining_negative_pressureand_Air_conditioning_and_allied_electrical_installation_works_at_Main_OT_and_Gynae_OT_at_Immambara_District_Hospital_Hooghly_Arrangement_of_maintaining_negative_pressure_and_Air_conditioning
2021_WBPWD_328563_1
WBPWD/EE/ HED / NIeQ- 43/ 2020-21
Open Tender
Electrical Work/ Equipment
Item Rate
30 days
HOOGHLY
Please refer Tender documents.
3 documents required · 3 mandatory
₹82,000
21 Sept 2021
23 Feb 2021
18 Mar 2021
23 Feb 2021
16 Mar 2021
23 Feb 2021
120 days
Amount
SITC of 5.5 TR Capacity Microprocessor based air cooled Condensing Unit compatible with eco-friendly R410A refrigerant,expansion valve, single scroll compressor and suitable for operation on 415 Volt, 50Hz, 3 PH AC supply. (Make: Hitachi / Mitsubishi / Daikin) [For Main OT Complex]
Supply, Installation, testing & commissioning of 16 HP Variable Refrigerant flow(VRF) modular type air-conditioning system with DIP-IPM Inverter Controlled with step-less modulation complete outdoor units, individual remote controller and centralized controller, interconnected refrigerant piping , full charge of R-410 refrigerant gas & oil, control cabling etc. incl. Supply & installation of Top Discharge Type Outdoor units equipped with highly efficient 100% Inverter scroll compressors (990 Steps by 0.1 Hz) with special heat exchanger, 27 Steps speed control DC motor condenser fan , newly design heat exchanger ( Heating -20deg C to 15deg C) ( Cooling -5deg C to 52deg C) Self Demand Function , auto check function for connection error, auto address setting and in built Double Stage Oil Separation to ensure minimum oil entrenchment and proper lubrication. Minimum COP Should be 3.52 at ARI Conditions at 100 % Load Condition. The system should be equipped with Heat Pump System.The condensing units should be capable for outside ambient Temp. 52˚C. The VRF unit should be manufactured in India only for better spare parts availibilty. (Hitcahi Model No.-RAS16HNBCMQ1 or euivalent model of Toshiba/Mitshubishi/O-General) [For Gynae OT]
SITC of Double skin construction Floor Mounting/Ceiling Suspended Air Handling Unit with Thermal Brake profile, Combination Filter ( Pre filter with 20µ Filter & Fine Filter with 3µ Filter and .3µHepa filter(Make:AFI/Spectrum/ Aeropure), 6-row deep DX cooling coil suitable for R410 refrigerant with Hard-drawn Copper pipe and 22G SS304 standard Drain Tray, Direct/Belt driven Backward curve Blower with IE-1 motor(Make-Kruger/Haveals/L&T), 4KW Variable Frequency Drive(Make:Electromec/L&T/ Haveals) and Supply Air Damper(Make-Dynacraft/Primier), Fan-Motor Mounting Base, Drive Motor with V-Belt Drive Package, Vibration Isolators. Air Handling Unit shall have 40 mm thick Sandwich Insulated Panels with Thermal Break Profile with 0.6MM Pre-Coated Galvanized Stainless Steel at Outer Skin and 0.6 MM Thick Plain Galvanized Stainless Steel at Inner Skin with Extruded Aluminium Frame Structure. VCD in Aluminium aerofoil construction to be provided in SA, FA, RA Openings. Capacity of AHU unit - 2200 CFM & 100 MM Static pressure / 6RD DX COIL / Thermal brake profile /VFD. (Make: Waves/ Zeco / VTS) [For Main OT Complex] (An Autocadd Generated Drawing has to be approved before starting of any construction)
SITC of Double skin construction Floor Mounting/Ceiling Suspended Air Handling Unit with Thermal Brake profile, Combination Filter ( Pre filter with 20µ Filter & Fine Filter with 3µ Filter and .3µHepa filter(Make:AFI/Spectrum/ Aeropure), 6-row deep DX cooling coil suitable for R410 refrigerant with Hard-drawn Copper pipe and 22G SS304 standard Drain Tray, Direct/Belt driven Backward curve Blower with IE-1 motor(Make-Kruger/Haveals/L&T), 4KW Variable Frequency Drive(Make:Electromec/L&T/ Haveals) and Supply Air Damper(Make-Dynacraft/Primier), Fan-Motor Mounting Base, Drive Motor with V-Belt Drive Package, Vibration Isolators. Air Handling Unit shall have 40 mm thick Sandwich Insulated Panels with Thermal Break Profile with 0.6MM Pre-Coated Galvanized Stainless Steel at Outer Skin and 0.6 MM Thick Plain Galvanized Stainless Steel at Inner Skin with Extruded Aluminium Frame Structure. VCD in Aluminium aerofoil construction to be provided in SA, FA, RA Openings. Capacity of AHU unit - 4000 CFM & 100 MM Static pressure / 6RD DX COIL / Thermal brake profile /VFD. (Make: Waves/ Zeco / VTS) [For Gynae OT] (An Autocadd Generated Drawing has to be approved before starting of any construction)
SITC of Refrigeration Valves, Controls - Expansion Valves, Dryer etc. (Mk. Honeywell / Dynafoss/Hitachi)
Supply and fixing of UVC EMIITTER for the above IDUs for prevention of fungus in the cooling coils, The minimum UV intensity in the coils shall be 700-800 UW-SEC/CM2. The unit shall be UL.Listed (UL-1995) and it should be suitable to fix the same in Follwing AHU (Make-Alfa / Ruks/Areo Pure).
Supply & Laying Hard / Soft drawn Copper Refrigeration pipe line for liquid and suction line suitable for R410 refrigerant & 13 mm thick Nitrile Rubber Insulation tube with supports & brackets as per direction of EIC.
a) Liquid Line ( 7/8" dia) with 13 mm thick nitrile rubber insulation with Al. Foil covered (Cu Pipe Make - Rajko/Ryoku/Nippon)(Insulation make - Accroflex/Suprime) (5.5TR Condenser unit to AHU)
b. Suction Line (1/2" dia) with 13 mm thick nitrile rubber insulation al foil covered (Cu Pipe Make - Rajko/Ryoku/Nippon)(Insulation make - Accroflex/Suprime) (5.5TR Condenser unit to AHU)
Supply & Laying Hard / Soft drawn Copper Refrigeration pipe line for liquid and suction line suitable for R410 refrigerant & 13 mm thick Nitrile Rubber Insulation tube with supports & brackets as per direction of EIC.
a) Liquid Line ( 1 1/8" dia) with 13 mm thick nitrile rubber insulation with Al. Foil covered (Cu Pipe Make - Rajko/Ryoku/Nippon)(Insulation make - Accroflex/Suprime) (from 11.0TR Condenser unit to AHU)
b) Suction Line (5/8" dia) with 13 mm thick nitrile rubber insulation al foil covered (Cu Pipe Make - Rajko/Ryoku/Nippon)(Insulation make - Accroflex/Suprime) (from 11.0TR Condenser unit to AHU)
Control Cabling by supply & laying FRLSH copper cable from Condensing Unit to Control Panel (make - Polycab/ Havells/Finolex/KEI)
a) 4 Core 10 sq. mm. FRLS Copper cable (from AHU Panel to AHU)
b) 3C x 1.5 Sqmm FRLS Copper cable (between AHU & Condensing Unit)(make - Polycab / Havells/Finolex/KEI)
Supply and fixing flexible double canvass connection for AHU to Duct.
Supply & Fixing Aluminium powder coated Continuous Grill. (Mk. System Air/ Premire /Air Master)
Supply, fabrication, Installation, testing & commissioning of duct made of AL sheet(Make:-NALCO or equivalent as per approved by EIC) of following guages duct complete with supports, flanges, turning vanes for supply air / return air duct erected with supporting rods, fustners, nuts etc. in accordance with the approved drawing of ducting layout
a) 20 SWG Ducting
b) 22 SWG Ducting
Acoustic lining of duct work with 9mm thick Open shel Nitrile Rubber. (K-Flex / Amracell / Supreme)
Supply & fixing 9 mm thick closed cell fire retardant Foil face nitrile rubber thermal insulation for Duct (K-Flex / Amracell / Supreme/K Flex)
Drain Water piping work out of PVC / HDPE hared pipes with Insulation, fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors.(make-- Finolex/ Supreme) a) 25mm.Dia
Charges for lifting and Hiring for scaffolding arrangement including dismantling at the end of work and carriage, for fixing of Air-Handling Unit, exhaust fan & duct etc. at the outside wall of the said building.
Charges for Assembling of AHU in Plant Room
Supplying, fabrication & fixing 3Nos. M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) of 1m length for making platform for installation of outdoor unit of 5.5 TR ductable split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete etc. fabricated with 2Nos. horizontal angle of 25 mm x 25 mm x 5 mm of 1m. length incl. S&F of safety cage made of angle (25X25X5mm) and flat (25X5mm) iron with necessary painting.
Supply and installation of Motrized fire Damper in Al.construction & with Fuseable link.(Make: AFI/Primier/Air Kolkata)
Supply and installation of Motrized Damper in Al.construction.(Make: AFI/Primier/Air Kolkata)
SITC of Ceiling Suspended Laminar Air Flow with Cleanliness : ISO Class 5 /AS US-FED CLASS-100/ as per ISO 14644-i)Direction of flow :- vertical (ii) Particle Retention : 0.3 Micron & above, (iii) Velocity : 90 feet / minute ± 20, (iv) Pressure gauge ; 0-25mm, (v) Power supply : 230V, single phase, 50Hz, Pleanum chamber. The complete cabinet should be made of Al. sheet (Make: AFI/Cardialec) (An Autocad Generated Drawing has to be approved before starting of any construction) [for Main OT]
Supply & Fixing of IDU & Duct Covered with 22 SWG ACP Board (Make:Aludecor) Coplete with linkages, levers, fittings, supports, all accessories any other item required to make the system complete as per direction of E.I.C.
Chrages for Trap door & duct Covered with 22 SWG ACP Board (Make:Aludecor/Protap Bond)Coplete with linkages, levers, fittings, supports, all accessories for IDU Maintenance make with ACP Board as per direction of E.I.C.
SITC of Single Skin Centrifugal Cabinet Type Fan complete with DIDW- forward curved belt driven centrifugal blower with Rotation of fan 1260-1400 RPM, Epoxy/ galvanized steel sheet cabinet with service access doors, Inlet & outlet drilled flanges, 0.6 to 1 KW TFC 1-Ph/220V/50 hz Motor with Fixed base, common base frame with spring isolators, Flange at inlet and outlet are provided to facilitate duct connection necessary hanging/supporting members etc. Sound level-56 dba. [Capacity:- Static pressure- 70 mmwg , Air-Volume:- 1000 CFM, Speed of Motor:-1260-1400 RPM].(Make:- Elta/Nikotra/Wolter/Ostberg)
SITC of 10 Micron Pre Filter with Frame,it will be fitted on Centrifugal Exhust fan & on the Fresh air Damper (Make:Spectrum/Air Kolkata/Air Filter Industries)
SITC of 0.3 Micron Hepa Filter,it will be fitted on Centrifugal Exhust fan.(Make:Spectrum/Air Kolkata/Air Filter Industries)
Supply & laying 4 Core 4.0 Sq.mm Copper Cable for Power line of Exhaust Fan
Supply & Fixing of Bird Screen as per direction of E.I.C(Make:Primier/Air Kolkata/Air Primier).
Supply & Fixing of Limit Switch
Supply & Laying 2 Core 1 Sq.mm power Cable of copper for Motorized damper to Limit Switch
Supplying, fabrication & fixing 2 Nos. M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) of 1m length for making Base Frame for installation of Exhuast Fan incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with 2 Nos. horizontal angle of 50 mm x 50 mm x 6 mm as per direction of E.I.C.
TERMS AND CONDITION 1. THE AGENCY MUST PROCURE THE MATERIALS FROM THE MANUFACTURER/OEM OR FROM THEIR AUTHORIZES. SALES CHANNEL SO THAT THE STANDARD WARRANTY / SOPPORT OF THE MANUFACTURER / OEM BECOMES APPLICABLE TO THE PRODUCTS TO BE DELIVERED AND INSTALLED BY THEM. 2. DOCUMENTS THAT AUTHENTICATES SUCH PROCUREMENT FROM THE MANUFACTURER/OEM OR FROM THEIR AUTHORIZES SALES CHANNEL SO THAT THE STANDARD WARRANTY / SOPPORT SHOULD BE SENT FROM THE e-MALE OF THE MANUFACTURER/OEM / AUTHORIZES SALES CHANNEL TO THE e-MALE OF ENGINEER-IN-CHARGE AND HARD COPY OF IT TO BE SUBMITTED DURING EXECUTION OF WORK/ SUBMISSION OF BILL. 3. IF ANY REFURBISHED MATERIAL IS SIPPLIED ABD INSTALLED, PENAL ACTION WILL BE TAKEN AS PER EXISTING RULES.
Add GST @12% :- Rs.
Add LWC @1% Rs.
P. M. COOLING AND ENGINEERING CO
ELECTRIC REFRIGERATION
stage.html
html • 0.05 MB
technical_625468.pdf
PDF • 0.61 MB
techsummary_625468.pdf
PDF • 0.76 MB
finance_625468.pdf
PDF • 0.48 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_625468.pdf
PDF • 0.48 MB
43.pdf
PDF • 0.12 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .