Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | ₹27.3 L Quoted ₹27.4 L | L1 | Accepted-AOC lowest and resonable |
| 2 | L2₹28.6 LRejected-Finance | ₹28.6 L | L2 | Rejected-Finance Being not lowest bidder |
| 3 | L3₹34.5 LRejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | ₹34.5 L | L3 | Rejected-Finance Being not lowest bidder |
| 4 | L4₹37.7 LRejected-Finance | ₹37.7 L | L4 | Rejected-Finance Being not lowest bidder |
| 5 | L5₹38.8 LRejected-Finance | ₹38.8 L | L5 | Rejected-Finance Being not lowest bidder |
| Sl No | Description | Qty | Unit | Commercial Traders L1 | mayur enterprises L3 | Mani Control System L4 | V.K. Enterprises L5 | AS Engineering L7 | YANSHIKA SECURITY SERVICES L2 | M P TYAGI ENGINEERS AND CONTRACTORS L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of old unserviceable damage/ rusted PCC pole/ steel tubular poles of any size necessary disconnecting cables/over head condcutor and removing unserviceable pole from site complete all as specified and directed. | 2 | Each | 500 ₹1,000 | 1,000 ₹2,000 | 100 ₹200 | 50,000 ₹1,00,000 | 1,000 ₹2,000 | 495 ₹990 | 4,999 ₹9,998 |
| 2.00 | Supply, installation, testing and commissioning of 11 KV, 630 Amps, Outdoor (IP54), RMU (Ring Main Unit) 4-way comprising of 02 Nos 630 Amps, manually operated Load Break Switch and 02 Nos 630Amp Fixed-Type VCB, inside robotically welded stainless steel 304 (Non Ferrite Non Megnetic Grade) tank having min. thickness 3+0.5 mm with IP 67 Degree of Protection. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions & complete with all accessories. The RMU shall be type tested for Internal arc test of 20kA/1 sec as per IEC62271-200. RMU shall have on-site-repairability features such as site replacable bushing/coupling/mechanism and gas refilling at site. The earthing busbar shall be provided inside each cable compartment for soilid earthing of Cable sheilds. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protection. The unit shall include the following with all necessary standard fitting as required at site. | 1 | Each | 8,21,000 ₹8,21,000 | 8,30,000 ₹8,30,000 | 12,40,000 ₹12,40,000 | 9,80,000 ₹9,80,000 | 10,75,500 ₹10,75,500 | 8,99,999 ₹8,99,999 | 19,99,999 ₹19,99,999 |
| 2.0102 Nos. Incoming Load Break Switch module consisting of following accessories : 11kV, 630A Load Break Switch module and integrated earthing switch, both with full making capacity. Short time current - 20kA/3-sec, Making Capacity - 50kAp Auxiliary contacts - 1NO + 1NC Spring-assisted snap-action mechanism driven via shaft that remains un-inhibited after motorization, if required in future. Cable boxes with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access to 3Cx300sqmm XLPE AL cable termination in live-condition, Right angle boots (push on type) Suitable site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes. Arc proof cable covers with self Interlocking mechanism with earth switch Capacitive voltage indication fixed type system as per IEC61243 | ||||||||||
| 2.0202 Nos. Outgoing VCB module consisting of following accessories : 11kV, 630A Fixed-Type VCB module with series disconnector cum earthing switch of making capacity. Short time breaking current/withstand - 20kA/3-sec, Making Capacity - 50kVap Aux. contacts - 1NO+1NC Stored-energy spring mechanism with integrated manual spring-charging handle to prevent theft at site and mechanical life of 5000CO operations achieved using single high endurance mechanism or multiple mechanisms supplied as spare. Cable boxes with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access to XLPE AL cable termination in live condition, Right angle boots (push on type) Suitable site replacable Cable bushings situated inside cable-cover to allow ease of access for installation/testing/replacement purposes 3O/C + 1E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. Relay should have facility to display the maximum loaded phase current also.Relay shall record minimum 5 fault records with time stamping. Associated ring-core cast-resin insulated CTs of appropriate ratio. Arc proof cable covers with self Interlocking mechanism with earth switch Capacitive voltage indication fixed type system as per IEC61243 | ||||||||||
| 2.03Note: (i) Each cable box will have Capacitive voltage LED indications to indicate cable-live condition inside the cable box. (ii) Necessay interclocking arrangement shall be provided for safety and operations (iii) One No. Operationg Handle for Manual Isolator/Disconnector/Earthing Operation and one no. manometer shall be provided (iv) Above switchgear shall confirm to relevant IEC (62271-200) for design, manufacturing and internal arc compliance. (v) Foundation PCC for installing the outdoor RMU as per manufacturer drawing 1mtr above the ground level will be installed at work site by tenderer and cost of the same deem to be included in rates quoted and nothing extra on this account will be admissible. | ||||||||||
| 3.00 | Supply, laying, connecting and testing XLPE insulated (Earthed) cable in trenches/or fixed on pole etc in screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 11000 Volt grade, cross sectional area 185 Sqmm, 3 Core Conforming to IS-7098 (Part-II)-1985 complete all as specified and directed. (Note: Excavation & earth work shall be measured and paid separately) | 600 | Running Meter | 1,840 ₹11,04,000 | 1,790 ₹10,74,000 | 1,850 ₹11,10,000 | 2,110 ₹12,66,000 | 2,077 ₹12,46,200 | 1,829 ₹10,97,400 | 1,799 ₹10,79,400 |
| 4.00 | Excavation in trenches in soft/loose soil not exceeding 1.50 Meter wide and not exc.1.5 Meter deep and getting out for taking out/laying cable, poles & stay etc, complete all as specified and as directed by Engineer-in-Charge. | 243 | Cubic Meter | 85 ₹20,655 | 100 ₹24,300 | 200 ₹48,600 | 300 ₹72,900 | 150 ₹36,450 | 125 ₹30,375 | 149 ₹36,207 |
| 5.00 | Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and as directed. | 182.25 | Cubic Meter | 20 ₹3,645 | 20 ₹3,645 | 10 ₹1,822.5 | 100 ₹18,225 | 85 ₹15,491.25 | 20 ₹3,645 | 19 ₹3,462.75 |
| 6.00 | Removal of excavated surplus soil to a distance n exc. 50 Meter and depositing where directed at a level not exc 1.5 Meter above the starting point complete all as specified and as directed. | 60.75 | Cubic Meter | 25 ₹1,518.75 | 20 ₹1,215 | 5 ₹303.75 | 100 ₹6,075 | 45 ₹2,733.75 | 20 ₹1,215 | 29 ₹1,761.75 |
| 7.00 | M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm) and 18cm punnd thickness shall be paid complete all as specified and as directed. | 48.6 | Cubic Meter | 350 ₹17,010 | 350 ₹17,010 | 400 ₹19,440 | 850 ₹41,310 | 250 ₹12,150 | 295 ₹14,337 | 299 ₹14,531.4 |
Tender Value
₹46.1 L
EMD Value
₹92,240
Closing Date
9 May 2026, 6:00 pmClosed
CWE (AF) TUGHLAKABAD
Headquarters CWE AF Tughlakabad, Air Force Station, Tughlakabad, PO Sangam Vihar, New Delhi 110 080
PROVISION OF INDEPENDENT HT FEEDER FROM SEKHAWATI GRID WITH RING MAIN UNIT AT AF STN PALAM UNDER GE (AF) GURGAON NO 1
2026_MES_759935_1
CWE/TKD/GUR/TOKEN-77 OF 2025-26
Open Tender
Electrical and Maintenance Works
180 days
PALAM UNDER GE AF GURGAON NO 1
As per NIT.
7 documents required · 7 mandatory
₹500
GE (AF) GURGAON NO. 1
₹92,240
Yes
1 Jul 2026
10 Apr 2026
11 May 2026
10 Apr 2026
9 May 2026
25 Apr 2026
13 Apr 2026 - 20 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Dismantling of old unserviceable damage/ rusted PCC pole/ steel tubular poles of any size necessary disconnecting cables/over head condcutor and removing unserviceable pole from site complete all as specified and directed. | - | Each | - | - |
| - | Supply, installation, testing and commissioning of 11 KV, 630 Amps, Outdoor (IP54), RMU (Ring Main Unit) 4-way comprising of 02 Nos 630 Amps, manually operated Load Break Switch and 02 Nos 630Amp Fixed-Type VCB, inside robotically welded stainless steel 304 (Non Ferrite Non Megnetic Grade) tank having min. thickness 3+0.5 mm with IP 67 Degree of Protection. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions & complete with all accessories. The RMU shall be type tested for Internal arc test of 20kA/1 sec as per IEC62271-200. RMU shall have on-site-repairability features such as site replacable bushing/coupling/mechanism and gas refilling at site. The earthing busbar shall be provided inside each cable compartment for soilid earthing of Cable sheilds. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protection. The unit shall include the following with all necessary standard fitting as required at site. | - | Each | - | - |
| - | 02 Nos. Incoming Load Break Switch module consisting of following accessories : 11kV, 630A Load Break Switch module and integrated earthing switch, both with full making capacity.
Short time current - 20kA/3-sec, Making Capacity - 50kAp
Auxiliary contacts - 1NO + 1NC Spring-assisted snap-action mechanism driven via shaft that remains un-inhibited after motorization, if required in future. Cable boxes with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access to 3Cx300sqmm XLPE AL cable termination in live-condition, Right angle boots (push on type) Suitable site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes.
Arc proof cable covers with self Interlocking mechanism with earth switch Capacitive voltage indication fixed type system as per IEC61243 | - | - | - | - |
| - | 02 Nos. Outgoing VCB module consisting of following accessories :
11kV, 630A Fixed-Type VCB module with series disconnector cum earthing switch of making capacity. Short time breaking current/withstand - 20kA/3-sec, Making Capacity - 50kVap Aux. contacts - 1NO+1NC
Stored-energy spring mechanism with integrated manual spring-charging handle to prevent theft at site and mechanical life of 5000CO operations achieved using single high endurance mechanism or multiple mechanisms supplied as spare. Cable boxes with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access to XLPE AL cable termination in live condition, Right angle boots (push on type)
Suitable site replacable Cable bushings situated inside cable-cover to allow ease of access for installation/testing/replacement purposes
3O/C + 1E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. Relay should have facility to display the maximum loaded phase current also.Relay shall record minimum 5 fault records with time stamping. Associated ring-core cast-resin insulated CTs of appropriate ratio. Arc proof cable covers with self Interlocking mechanism with earth switch Capacitive voltage indication fixed type system as per IEC61243 | - | - | - | - |
| - | Supply, laying, connecting and testing XLPE insulated (Earthed) cable in trenches/or fixed on pole etc in screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 11000 Volt grade, cross sectional area 185 Sqmm, 3 Core Conforming to IS-7098 (Part-II)-1985 complete all as specified and directed. (Note: Excavation & earth work shall be measured and paid separately) | - | Running Meter | - | - |
| - | Excavation in trenches in soft/loose soil not exceeding 1.50 Meter wide and not exc.1.5 Meter deep and getting out for taking out/laying cable, poles & stay etc, complete all as specified and as directed by Engineer-in-Charge. | - | Cubic Meter | - | - |
| - | Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and as directed. | - | Cubic Meter | - | - |
| - | Removal of excavated surplus soil to a distance n exc. 50 Meter and depositing where directed at a level not exc 1.5 Meter above the starting point complete all as specified and as directed. | - | Cubic Meter | - | - |
| - | M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm) and 18cm punnd thickness shall be paid complete all as specified and as directed. | - | Cubic Meter | - | - |
| - | Supply and laying reinforced precast concreate cable cover, HV , flat size 450mm x 230mm x 50 mm for HT cable protection complete all as specified and as directed. | - | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
CompleteTenderDocuments.pdf
Tender Documents • 1.73 MB
BOQ_851253.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid