Tender Value
₹1.5 L
EMD Value
₹2,000
Closing Date
30 Jul 2020, 11:00 amClosed
E.E.E-400 KV S/S DIV -II MURADNAGAR
E.E.E-400 KV S/S DIV -II RAWALI ROAD MURADNAGAR
OVERHAULING AND REPAIRING THE CIRCULATING OIL PUMP SET AND COOLING FANS OF 100 MVA-II AT E-400 KV S/S DIV-II MURADNAGAR
2020_UPTCL_491932_1
T-03/E400KVSSDII/M/2020-21
Open Tender
Electrical Works
Fixed-rate
60 days
E.E.E-400 KV S/S DIV -II MURADNAGAR
AS PER DOCUMENT ATTACHED WITH TENDER FORM
2 documents required · 2 mandatory
₹590
AS PER NIT
₹2,000
30 Jul 2020
10 Jul 2020
30 Jul 2020
10 Jul 2020
30 Jul 2020
10 Jul 2020
Amount
Overhauling/repairing of circulating oil pump set (centrifugal pump) of 7.5 HP, 3 phase 415 volt, 1800 RPM at 100 MVA of CGL make transformer. The work inculding following steps of work are as below:- a) Close both sides butterfly valve of centrifugal pump and loosening all nuts and bolts for draining centrifugal pump oil into drum. b) Opening all wiring connection from centrifugal pump and open nut for removing the pump set from its radiator pipe carefully. c) Carriage pumps from site to work shop and work shop to site at his own cost. d) Rewinding the defective centrifugal pump and replaced all bearing by providing SKF/standard make bearing balancing the shaft by machining resealing the shaft rewinding good quality is mark copper wire super enamelled of class 181 insulation and proper checking and testing for completion of work. e) Repairing the pump of 100 MVA T/F by repairing its impeller gasket etc. and fixing proper alignment of its impeller with its motor work also including machining of shaft/impeller. f) Re-fixing complete rewinded and repaired centrifugal pump set to radiator pipe with the help of nut bolt, inserting proper gasket oil seal etc. connection the cable wire in its junction box to complete the work satisfactory.
Dismantling the Cooling fan of size 36", 3 phase 50Hz, 1.2KV 1400RPM, 415V Delta connection from 100 MVA Transformer No-1 BHEL make rewinding of burnt damage bearing SKF make proper providing the insulation and varnishing balancing the shaft and blade releasing the armature from motor and rewinding will be done and insert the super enameled copper wire of class "B" insulation and refitting the cooling fan at Transformer and proper checking the running position.
Meena Elect and Engg Works
Gupta Elect and Engg Works
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .