Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹34.5 L+₹1.6 L (4.78%)Rejected-Finance 35 MODEL TOWN G T ROAD JANDIALA GURU DISTRICT AMRITSAR | JANDIALA GURU | AMRITSAR | PUNJAB | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹34.5 L+₹1.6 L (4.88%)Rejected-Finance N A | NA | NA | 121004 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹34.9 L+₹2.0 L (6.11%)Rejected-Finance C 204 NANGLI EXTN NEW DELHI | WEST | DELHI | 110043 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹35.1 L+₹2.2 L (6.80%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
20 Feb 2024, 6:00 pmClosed
GE (East) Delhi Cantt-10
GE (East) Delhi Cantt-10
CERTAIN REPAIR TO PLASTER WORK, JALI, BOUNDARY WALL, GATES OTHER MISC B/R WORK AT MANEHSHAW MARG, URBAN VILLAGE, CASSEL ROAD IN THE AOR OF AGE B/R-I UNDER GE (EAST) DELHI CANTT-10
2024_MES_639657_1
CA No GE/DE-121/22023-24
Open Tender
Civil Works
Item Rate
180 days
Delhi Cantt
Class D cat a(i)
8 documents required · 8 mandatory
₹500
GE (East) Delhi Cantt-10
₹99,800
Yes
9 Mar 2024
30 Jan 2024
22 Feb 2024
30 Jan 2024
20 Feb 2024
13 Feb 2024
Amount
Taking down cement or cement lime plaster, grit plaster any description on brick or stone or RCC walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M & L for 15mm thick rendering in cement mortar 1:4 on fair face of brick walls/ concrete surfaces and finished even and fair without using extra cement in any position incl scafolding as required etc, complete all as specified and as directed.
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles complete all as specified.
M & L for Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, complete all as specified and directed by Engr-in-Charge.
All as per Srl item No 4 here -in-before but except bricks
M & L for Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4, complete all as specified and directed by Engr-in-Charge.
All as per Srl item No 6 here -in-before but except bricks
Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for etc complete.
M & L for RCC M25 Design Mix using 20mm graded agg as in footings, plinth beam and bases of columns , beams etc complete all as specified and as directed.
M & L for RCC M25 Design Mix using 20mm graded agg as in columns , piers posts and struts complete all as specified and as directed.
M & L for mild steel TMT bar 10mm dia and over cut to length,bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for mild steel TMT bars 5 mm dia and over upto and including 10 mm dia in strirrups, spaces and binder and including mild steel wire (annealed) not less than 0.9mm dia etc complete all as specified and directed by Engr-in-Charge.
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, plinth beam , beam etc sides and soffits (if any) of foundation and similar work; vertical or to batter complete all as specified and directed.
M & L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions square or rectangular rough finished surfaces of concrete laid flat complete all as directed.
M&L PCC (1:2:4) type B-0 using 12.50 mm graded stone aggregate as in benching for manholes, bands, coping, bed plate etc with slightly chamfered or rounded angles including necessary from work, if any, and finishing exposed surface even and smooth without using extra cement complete all as specified & directed.
M & L for PCC 1:2:4 type B-2 using 20 mm graded stone aggregate as in surface channels and drains all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed by Engr-in-Charge.
M&L for PCC (1:3:6) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concreteetc, complete all as specified & directed
M & L for Washed stone grit plaster on exterior walls in two layers (colour and design as approved by GE), under layer 12 mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square meter, top layer 15 mm white cement plaster 1:1/2:2 (1 white cement: 1/2 coarse sand : 2 stone (white) chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed (Payment for providing grooves shall be made seprately).
Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer -in -Charge
M&L two coat of synthetic enamel paint (finishing coat) over one coat of primer to new steel surfaces of any description over 10 cm width or girth incl prepration of surfaces complete all as specified.
M & L for preparation of old Steel and Iron surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as Specified and directed.
M & L for preparation of new surface decorated brick/concrete/ plastered or unplastered surfaces of walls, pillars, cornices by brooming down etc and applying two coat of cement base paint over a coat of cement primer complete all as specified and directed
M & L for preparation of old surface decorated brick/concrete/ plastered or unplastered surfaces of walls, pillars, cornices by brooming down etc and applying Two coat of cement base paint complete all as specified and directed
M & L for preparation of old external surfaces of walls, pillers, cornices etc by scrapping down smoke soot, moulds, moss, efflorescent salts , trading oil and greasy spots and including cracks/holes in surface filling with white putty and scrapped surface area to obtain smooth finishing and applying one coats of weather proof exterior acrylic emulsion paint premium quality complete all as specified and directed.
M & L complete removal of existing treatment including cracks/holes filling with white putty and applying 2mm thick layer of water proof wall care putty, again sand papering thus making surface even & smooth and applying two coats of weather proof exterior acrylic emulsion paint premium quality over priming coat of exterior primer and Allow 6-8hrs to dry the surface for painting of subsequent coat complete all as specified and as directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified
S & F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified.
S & F framed work such as in door frame, door shuters / gate of angel or other section with gusset plates, rails, braces, etc complete , drilled for fixing of steel sheeting or other covering. Doors, posts , struts etc to be prepared for hanging or sliding with and including either hooks and hings or steel hanging door fittings, including hings hold fast of Fe 410-W (Gde E-250 quality) etc complete all as specified.
Dismantling fencing wire mesh any type of any description not otherwise provided for complete all as specified.
S & F Chain link MS galvanisd fencing any size or type ( approved by GE) including line wires, any mesh, size and type to any of standards , rails , staining bolts, etc including provision of bindings wire complete all as specified and directed.
M & L for 300 mm bore of RCC hume pipe class NP 2 laid and and jointed complete with collars and laid in trenches with laying pipes level and tested including dismantling of existing pipe in any position, complete all as specified and as directed.
M/L for cleaning/de-silting of loose mud, rubbish etc from drain bed including uprooting of vegetative growth throughly and wire brushing including flushing with water so as to achieve smooth flow of water in drain of bed width up to 60 cm and any depth and including removing the waste material outside the MoD land etc complete all as directed by Engineer in charge.
S&F steel work in tubular trusses,purline, doors , posts, frame works any type etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed
Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of plain or corrugated AC sheeting any gauge thickness as in roof covering and any position, complete all as specified and as directed.
S & F Pre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour as in ridges hips, vally gutter, drip and straight flashing , fixed with self tapping screws and including dismantling of plain or corrugated AC sheeting any gauge thickness as in roof covering and any position etc complete all as specified and directed
S & F for 2 mm thick fibre glass reinforced translucent sheeting with additional reinforcement of chicken mess with two corrugation side lap fixed with 'L' or 'J' type or cranked hook bolts including dismantling of of existing sheeting of any type, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor or in any position and paving not exc. 15 cm thick (below or above ground level) complete all as specified and as directed.
Demolition of cement concrete of any description and in any position complete all as specified and as directed.
Dismantling floor, hearth or wall tilling , granite, stone cladding , interlocking etc including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M & L for 75 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing completed all as specified and directed.
M & L 18 to 20 mm thick granite (colour as approved by GE) of any type work table rubbed and polished as in steps, jambs, pillars, window cills, platform, water point platforms , floor etc over & including 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite slab , notching and moulding including dismantling old exisitng granite slab complete all as specified and as directed .
M & L for factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required (Size and pattern as approved by GE) and including dismantling of old existing kerb stone of any type and size etc complete all as specified and as directed.
M & L for Machine pressed precast conctete interlocking paver block of any shape and size (Two colour combination) conforming to IS 15658-2006 of 80 mm thick, M-40 Grade laid dry in floor/path over and including 50 mm thick sand layer after dismantling of old existing paver block tile complete all as specified and as directed.
M & L for Machine pressed precast conctete interlocking paver block of any shape and size (Two colour combination) conforming to IS 15658-2006 of 60 mm thick, M-35 Grade laid dry in floor/path over and including 50 mm thick sand layer after dismantling of old existing paver block tile complete all as specified and as directed.
M & L for OUT DOOR coloured ceramic chequered tiles 8 to 9 mm thick (square/rectangular) area of each tiles exceeding 0.06sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified.
S&F Precast SFRC square or rectangular drain / manhole covers 75 mm thick with frame medium duty conforming to IS-12592 , with holes etc including demolition of existing slab covers, including necessary reinfocement, complete all as specified and as directed.
Dismantling old posts or struts ( wood, steel or RCC) any section, including taking out embedded portion and making good and excavation & prepration of post holes removal of surplus excavated material completed all as specified and directed
S & F pre-cast prefabricated reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) in precast prefabricated columns for wall as required suitable with proper size channel for fixing of Pre fabricated RCC wall panels of required size as per site requirement including fixing of columns to a required depth , PCC jali columns, fencing posts, straining or terminal posts, struts etc. for fencing , average sectional area exc 80 sq. cm but n.exc 200 sq. cm with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and all as specified.
S & F Precast Prefabricated RCC wall Panels of 50 to 60 mm thick with suitable size fixed properly in prefabricated columns and sealed properly with filling materials as per manufacturer's instructions, complete all as specified and as directed.
Providing and fixing "RAJSHRI" Brand factory made WPC railing combining WPC board/Fancy designer type grating and WPC frame 100% solid WPC (wood polymer composite) railing of required length and of 2' to 2.5' height , comprising of virgin PVC resin of K value 58-60 (Suspension Grade) , Calcium Carbonate and natural fibres (Wood Powders/rice husk//wheat husk) and non toxic additives, made from single extrusion process, WPC foam board with having minimum density 650kg/cbm and WPC frame having minimum density 780kg/cbm manufactured by "RAJSHRI" an ISO 9001-2015 certified Company, having good screw holding capacity (screw withdrawal strength of 2000N (Face) & 1100N (Edge) , Minimum comprising of 50N/mm2, Modules of elasticity 850N/mm2 and resistance of speed of flame of class A category with property of being termite/Borer free water /Moisture proof and fire resistance. For WPC railing WPC jali to be fixed with WPC frame of size 75x50mm with necessary supporting lengths at vertical as well as horizontal at wall frames to be fixed with 3"x3" GI 'L' or SS cleats to support vertical frame lengths including demolition /dismantling of existing any type of jallies with frames complete all as specified and as directed. (Make : Rajshree or equivalent) (Note : The said item shall be fixed for view cutter in any positions as requirement at site, the rate of item includes wpc frames )
M & L including T&P for Cleaning of existing water tanks (any type and any capacity) on top of multistoried buildings (G+8 Levels), including emptying the water tank completely(depth of water tank up to 3.00 M), cleaning the internal wall surfaces and bottom surface of tank to remove all disputation/fungus,other micro-organisms etc. Using light hammer & wire brushes, taking out and removing sediment loose dirt/mud sludge,vegetation and other foreign materials completely from the internal and external surface of tank disposal of all the waste/spoil outside from the MoD land . And washing repeatedly with acid based material, corrosion inhibitors and dispersing agents solution inside surfaces of tank with water and washing with clean water thoroughly and preparation of the surface to review new plaster complete all specified and directed by Engineer-in-charge.
M & L including T&P for Cleaning of PVC water tanks (500 Ltrs capacity) including on top of multistoried buildings (G+8 Levels), including emptying the water tank completely, cleaning the internal wall surfaces and bottom of tank by scraping with steel wire brushes, removing all dirt and scaling inside the tank and washing clean of all loose debris, complete all as specified and to the entire satisfaction of Engr-in-Charge.
M & L including T&P for Cleaning of PVC water tanks (100 Ltrs capacity) , including emptying the water tank completely, cleaning the internal wall surfaces and bottom of tank by scraping with steel wire brushes, removing all dirt and scaling inside the tank and washing clean of all loose debris, complete all as specified and to the entire satisfaction of Engr-in-Charge.
S & F Rotational moulded polyethylene water storage tanks 500 lts capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PTMT ball valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed including taking out existing unserviceable overhead tank of any description complete.
S & F Rotational moulded polyethylene water storage tanks 1000 lts capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PTMT ball valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed including taking out existing unserviceable overhead tank of any description complete.
Cutting shrubs, wild growth/trees n exc 30cm girth and removing complete vegetation growth from walls incl taking out roots from roofs/brick work/Shaft/RCC work joints etc and making good the disturbed surface with PCC 1:2:4 type B-0, using 12.5mm graded crushed stone aggregate including treating affected area with acid wash to check further growth of vegetation and disposing off the rubbish from site (MoD Land) from the above mentioned area complete all as specified and as directed. Note:- The rates quoted by the tenderers are deemed to be up to G+9 floor bldg included roof , external walls , shafts area and safety precautions , necessary T&P, scaffolding/jullha etc as required.
S&F steel water tubing galvanised 15mm bore medium grade with all fittings fixed to walls, under floors and on ceiling surfaces , including cutting chases , pipning in making good to facings where required and pointing in Cement mortar 1:3 for concealed water tubing or conduit pipe etc and including taking up or down old steel tubing 15 mm bore and connecetions in any postion etc complete all as specified and directed. NOTE:-The work will be also executed at Highrise bldgs and necessary T&P, scaffolding/jullha etc as required is included in Quoted rates.
S&F steel water tubing galvanised 20 mm bore medium grade with all fittings fixed to walls, under floors and on ceiling surfaces and including taking up or down old steel tubing 20 mm bore and connecetions in any postion etc complete all as specified and directed. NOTE:-The work will be also executed at Highrise bldgs and necessary T&P, scaffolding/jullha etc as required is included in Quoted rates.
S&F steel water tubing galvanised 25 mm bore medium grade with all fittings fixed to walls, under floors and on ceiling surfaces and including taking up or down old steel tubing 25 mm bore and connecetions in any postion etc complete all as specified and directed.NOTE:-The work will be also executed at Highrise bldgs and necessary T&P, scaffolding/jullha etc as required is included in Quoted rates.
S&F steel water tubing galvanised 40 mm bore medium grade with all fittings fixed to walls, under floors and on ceiling surfaces and including taking up or down old steel tubing 40 mm bore and connecetions in any postion etc complete all as specified and directed.NOTE:-The work will be also executed at Highrise bldgs and necessary T&P, scaffolding/jullha etc as required is included in Quoted rates.
S&F steel water tubing galvanised 50 mm bore medium grade with all fittings fixed to walls, under floors and on ceiling surfaces and including taking up or down old steel tubing 50 mm bore and connecetions in any postion etc complete all as specified and directed. NOTE:-The work will be also executed at Highrise bldgs and necessary T&P, scaffolding/jullha etc as required is included in Quoted rates.
S & F in repair 20 mm bore Gun metal, globe or gate valves, with iron wheel head / leaver arm, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S & F in repair 25 mm bore Gun metal, globe or gate valves, with iron wheel head / leaver arm, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S & F in repair 40 mm bore Gun metal, globe or gate valves, with iron wheel head / leaver arm, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S & F in repair 50 mm bore Gun metal, globe or gate valves, with iron wheel head / leaver arm, screwed both ends for iron pipe and fixed complete all as specified and as directed.
M & L Coloured Glazed ceramic tiles in vertical surface 600 x 300 x 7-8 mm thick, such as skirting, dados , etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 10 mm thick rendering in CM 1:4 complete all as specified and directed.
M & L Non skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match laid over & including 15 mm thick avg screed bed in CM 1:6 complete all as specified and directed.
M L for PCC 1:3:6 (40 mm graded Aggregate) as in sunkern floor , fdn, mass concrete etc allas specified and directed
M & L 25 mm Thick PCC type B-0 1:2:4 (12.5mm graded aggregate) as in flooring, under Tiles and etc all as specified and directed
S&F in repair 15mm angle valves, chromium plated cast copper alloy, polished body screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 15mm bore steel tubing complete all as specified & directed. ( Make : Hindware /Jaquar/Somany /Cera/MARC/Kohler/Plumber as approved by GE)
S & F in repairs 15 mm bore bib tap (long body) ,fancy type chromimum plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions. complete all as specifed and directed. ( Make : Hindware /Jaquar/Somany /Cera/MARC/Kohler/Plumber as approved by GE)
S&F in repair Brass CP Basin mixer central hole for making hot and cold water fixed as per manufacturers manual with long shunk and cup washers, screwed both ends suitable for 15mm bore GI Pipe joints to GI pipes or unions, complete all as specified and directed. Make : Jaquar Continental CON-CHR-167 KNB or equivalent in Hindware / Somany /Cera/MARC/Kohler/Plumber as approved by GE
S&F in repairs brass chromium plated wall mixture 3 in 1 system with provision for hand shower and over head shower and suitable for 15mm bore GI pipe including three joints to steel pipes or unions and plugging and screwing to walls all as specified and directed. Make : Jaquar Continental CON-CHR-273KNUPR or equivalent in Hindware / Somany /Cera/MARC/Kohler/Plumber as approved by GE
S & F in repair Two way bib tap 15mm bore dia or pipe, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, fixed in repairs, complete all as specified and as directed. Make - Jaquar or equivalent in Hindware / Somany /Cera/MARC/Kohler/Plumber as approved by GE
S & F in repair PVC connections 15mm size with PTMT nuts of length 600 mm complete all as specified and as directed.
S&F in repairs health faucet chromium plated ABS body with 1.00m CP long flexible pipe and brass chromium plate nuts & wall hook completed all as specified Make : Jaquar ALD-CHR-587 or equivalent in Hindware / Somany /Cera/MARC/Kohler/Plumber as approved by GE
S & Fin repair CP shower rose fancy type 150mm x 150mm size with 300 / 600 mm long shower arm, fixed in repair to 15mm bore pipe, complete all as specified and as directed. Make :- Jaquar or equivalent in Hindware / Somany /Cera/MARC/Kohler/Plumber
S&F in repairs of 32mm brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, unions and cap and fixed, complete all as specified and directed.
S & F in repair full pedestal pattern wash hand basin, size of basin 630mm x 510mm and pedestal of 900mm long colour as approved by GE including brakets , chromium plated brass waste coupling etc complete all as specified and as directed.
S & F in repair Vitreous China wash down pedestal pattern EWC, white and including with PVC (SWR) ' S' Trap , seat cover with connection to drain and to flushing pipe antisyphonage pipe, and making good to floor complete all as specified and directed.
S&F in repair 10 Ltrs capacity PVC valveless symphonic action type flushing cistern white low level with inlet, ball valve float handle including bracket etc complete all as specified and directed
S & F in repair flush pipe of polyethylene of low or high density or PVC 32 mm dia for low level cistern complete all as specified and directed.
S&F repair 75 mm bore PVC (SWR) pipes single socketed , in any length with rubber ring joints ,laid in trenches or in floor or in wall complete all as specifed and directed.
S & F in repair 75mm mm dia PVC floor trap , with SS grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and as directed.
S&F in repairs of 20 mm Ball brass valves, high pressure, with polythene float and flynut, screwed for iron pipe or brass ferrule and fixed complete
S&F in repairs of 25 mm Ball brass valves, high pressure, with polythene float and flynut, screwed for iron pipe or brass ferrule and fixed complete
S&F in repairs of 40 mm Ball brass valves, high pressure, with polythene float and flynut, screwed for iron pipe or brass ferrule and fixed complete
S & F in repair Sand cast iron soil waste and vent pipes 100mm dia, in any length, with cement joints, laid in trenches/floors, fixed to walls with CI/MS clamps and conforming to IS-1729, complete all as specified and as directed. NOTE:-The work will be also executed at Highrise bldgs and necessary T&P, scaffolding/jullha etc as required is included in Quoted rates.
S&F in repair Sand cast iron soil waste and vent pipes75 mm dia, in any length, with cement joints, laid in trenches/floors, fixed to walls with CI/MS clamps and conforming to IS-1729, complete all as specified and as directed. NOTE:-The work will be also executed at Highrise bldgs and necessary T&P, scaffolding/jullha etc as required is included in Quoted rates.
S&F in repair CI bend for 100mm bore any radius, diminishing pieces or tapers (larger bore measured), fixed to walls, complete all as specified and as directed.
S&F in repair CI bend for 75mm bore any radius, diminishing pieces or tapers (larger bore measured), fixed to walls, complete all as specified and as directed.
S&F in repair CI Branch 75mm bore pieces with access door tee/Y etc , single (equal or unequal ), ordinary or inverted ) (spigot or socket type ) or with parallel branches complete all as specified & directed.
S&F in repair CI Branch pieces 100mm bore with access door tee/ Y etc , single (equal or unequal ), ordinary or inverted ) (spigot or socket type ) or with parallel branches complete all as specified & directed.
NOTE (a) The work mentioned in above items shall be carried out including in multi storied buildings (G+8) which may require scaffolding or Jhulla arrangements or any other T&P items are included in the quoted rates by the contractor. (b) Laying CI /GI/PVC drain pipes to be carried out from top of roof slab up to bottom of bldg floor wise through shaft area and as per site requirement and as directed by Engr-in-Charge. (c) All debris obtained from demolition item shall be removed from the site at daily basis to avoid any seepage/leakage from roof slab and deposit the debris out of the MoD land.
STAR CONSTRUCTION CO
Vipul Construction
S GOURAV PRAKASH ENTERPRISES
a.k constructions
sunil traders
M/s Shubh Enterprises
A R construction
R. S. Associates
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .