Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC | L1 | Accepted-AOC Award of Contract | |
| 2 | L2₹24.4 L+₹3,000 (0.12%)Rejected-AOC PLOT NO 4 SUDARSHAN ROW RESIDENCY GAWADE MALA PIPELINE ROAD SAVEDI AHMEDNAGAR 414003 | AHMEDNAGAR | AHMEDNAGAR | MAHARASHTRA | 414003 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹25.9 L+₹1.5 L (6.16%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹37.8 L+₹13.4 L (54.9%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
23 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Repairs / Replacement of street light and certain other maint works in the area of AGE E/M under GE (N) Ahmednagar
2021_MES_462589_1
8556 / E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Ahmednagar
Class D Cat b(i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹80,000
Yes
9 Sept 2021
26 Jul 2021
25 Aug 2021
26 Jul 2021
23 Aug 2021
10 Aug 2021
60 days
Amount
Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on soft/ lose soil etc complete all as specified and directed by Engineer-in-Charge
All as per Sl item No 1 (here-in-before) but hard/ dense soil
Returning, filling in, including spreading , levelling , watering and well ramming in layers not exc 25cm of any soil.
Supply and Lay HDPE pipe 50 mm dia for laying of LT cables with all accessores etc complete all as specified and directed by Engineer-in-Charge
Removing excavated materials(soils) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point etc complete all as specified and directed by Engineer-in-Charge
Material and labour in replacement of 25 mm dia GI Pipe light grade ISI Marked with all fittings laid in trenches , fixed to walls / poles with FI Clamps of size 40x5 mm etc complete all as specified and directed by Engineer-in-Charge
Taking out existing unserviceable UG Cable by disconnecting of connections and laying only LT UG Cable of following size etc complete all as specified and directed by Engineer-in-Charge. Note :-(a) UG Cables , Excavation, RFR, & Removing will be paid separately.
(a) 10 Sqmm 2 Core
(b) 10 Sqmm 4 Core
(c ) 16 sqmm 4 Core
Supply & Laying of LT UG Cable of following Sizes etc complete all as specified and directed by Engineer-in-Charge
(a) 10 Sqmm 2 Core
(b) 10 Sqmm 4 Core
(c ) 16 sqmm 4 Core
Supply and replacement of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension GI wire, one twin core cable flat or circular with size 4sqmm etc complete all as specified and directed by Engineer-in-Charge
All as per item No 15 (here-in-before) but 6 Sqmm two Core
All as per Item No 15 (here-in-before) but 10 sqmm 2 Core
Material and labour in replacement of 40mm dia GI Pipe light grade ISI Marked with all fittings laid in trenches , fixed to walls / poles with FI Clamps of size 40x5 mm etc complete all as specified and directed by Engineer-in-Charge
Taking out Old existing security light (HPSV/Tube light fitting) and fixing of LED street light, 36 Watt fixed with suitable size of GI Bracket,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box all as specified and directed. Note : Street light 36 Watt will be issued under Sch 'B' freee for fixing.
Taking out Old existing security light (HPSV/Tube light fitting) and fixing of LED street light, 45 Watt fixed with suitable size of GI Bracket,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box all as specified and directed. Note : Street light 45 Watt will be issued under Sch 'B' freee for fixing.
Taking out Old existing security light (HPSV/Tube light fitting) and fixing of LED street light, 60 Watt fixed with suitable size of GI Bracket,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box all as specified and directed. Note : Street light 60 Watt will be issued under Sch 'B' freee for fixing.
Taking out Old existing security light (HPSV/Tube light fitting) and fixing of LED street light, 40 Watt fixed with suitable size of GI Bracket,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box all as specified and directed. Note : Street light 40 Watt will be issued under Sch 'B' freee for fixing.
Taking out Old existing security light (HPSV/Tube light fitting) and fixing of LED flood light, 120 Watt fixed with suitable size of GI Bracket,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box all as specified and directed. Note : Street light 120 Watt will be issued under Sch 'B' freee for fixing.
Taking out Old existing security light (HPSV/Tube light fitting) and fixing of LED flood light, 200 Watt fixed with suitable size of GI Bracket,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box all as specified and directed. Note : Street light 200 Watt will be issued under Sch 'B' freee for fixing.
M & L for painting of Street light poles tubular type 9 mtr long with two coats of aluminium paint over one coat of red oxide as primer after preparing the surface including writing of pole Nos etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in replacement of MCB TPN, 63 Amps 10 KA breaking / rupturing capacity capacity 415 volt , 50 HZ conforming to IS 60898-1 including necessary connection with suitable size of copper cable etc complete all as specified and directed by Engineer-in-Charge. MAKE: CAT No DSMSCTNFO63 of Standard or equvalent.makes mentioned in list of makes in Appendix `C'
Supply and fix in replacement of LED post top lantern 40 Watt, with spun aluminium canopy & die cast aluminium spigot with opal PMMA acrylic diffuser pre wired with all accessories including making necessary connections and make it functional complete all as specified and as directed. . Make : Crompton cat Part No- LPTO-40-CDL or equvalent makes mentioned in list of makes in Appendix 'C'.
M &L in replacement of sintex box of outer side 280x170x130mm for street light control box including 4pole PVC contactor and 35x5mm clamp with nuts bolts and washers. Make: Sintex/National or equivalent as approved by GE
Supply and fixing in replacement of Triple pole and Neutral HRC type rewireable Swich fuse unit 63 Amp 415 volt AC 23 A 50 HZ conforming to IS 60947 1 & 3 fixing on Street light Pole with 32x4mm of MS Clamp and suitable size of nut, bolt and washers all as specified and directed by Engineer-in-Charge Cat Part No-#DTPN063 of Indoasian or equivalent makes mentioned in list of makes in Appendix `C'
All as Per Item No 29 (here-in-before) but 100 Amps TPN Cat Part No-#DTPN100 of Indoasian or equivalent makes mentioned in list of makes in Appendix `C'
Supply and fixing with replacement of MCB SP 6 to 32 Amps with PVC Enclouser fixing with pole or wall for individual street light/ security light control with suitable size of clamp nut , bolt and washers.make stanard, cat part No-DSMSCSPF006-032 or equivalent makes mentioned in list of makes in Appendix `C' Note: Rate of MS Clamp is include in Quoted Rates.
Material and labour for street light control board / box of size 0.50 X 0.50 X 0.20 m made out of 1.60 mm thick MS sheet fixed / mounted on pole by means of 2 Nos of FT clamps of size 25 X 3 mm comprising the following enclousers and connecting with suitable size of copper cable etc complete all as specified and directed by Engineer-in-Charge. a) MCB, TPN, 40 Amps, - 01 No MAKE: CAT No DSMSCTNF040 OF Stardard or its equivalent in makes mentioned in list of makes in Appendix `C' b) Timer switch, eletronic, ET 100 operating on 110 / 240 / 415 Volts, 50 Hz MAKE: CAT No SE92006 OF L&T or its equivalent in makes mentioned in list of makes in Appendix `C' c) Contactor ML 2, 32 Amps,415 Volt - 01 No MAKE: CAT No SS90701 OF L&T or its equivalent in makes mentioned in list of makes in Appendix `C'
Fixing only in replacemet LED Drivers for 42 watt LED Fittings any type and any make as per sample etc complte all as specified and directed by Engineer-in-Charge Note : 42 W LED Drivers will be issued under Schedule `B' firee for fixing
Fixing only in replacemet LED Drivers for 60 watt LED Fittings any type and any make as per sample etc complete all as specified and directed by Engineer-in-Charge. Note : 60 W LED Drivers will be issued under Schedule `B' free for fixing
Supply and fix in replacement of copper conductor XLPE insulated stranded , unarmoured ,extructed PVC type ST2 sheathed , 650/1100 volt graded as per IS 7098.of size 6 Sqmm 4 Core etc complete all as specifed and directed by Engineer-in-Charge. Make Polycab cat part No- SISLV4X610693 or equivalent makes mentioned in list of makes in Appendix `C'
Supply and fix in replacement of steel wire rope Grade AISI 316, 7/19 with 6mm dia etc complte all as specified and directed by Engineer-in-Charge
Supply and fix in replacement of copper conductor PVC insulated stranded , unarmoured , 650/1100 volt graded as per IS 7098.of size 2.5 Sqmm 5 Core
M & L for replcement of Chain sprocket in Highmast Light etc complete all as specified and directed by Engineer-in-Charge.
Inspection, maintenance and servicing of DG sets of the following capacities including alternator, electric panel board connection to DG Set for routine check ('A' check) of DG set for smooth functioning and carriying out maintenance complete as directed :- Monthly Service (a) Checking engine oil level and topping up as and when required NOTE : Oil shall be measured and paid separately (b) Checking and adjusting the belt for tension and replacemnt of belt NOTE: Belt shall be measured and paid separately (d) Checking of exhaust system for leakage (e) Draining of sediment from fuel filter and fuel tank (f) Cleaning of air cleaner element. Note : Replacement of Air Cleaner shall be measured and paid separately. (g) Checking engine alternator coupling, mounting bolts and alignment. (h) Tighting all nut, bolts, in alternator terminal block.
(j) Checking of alternator carbon brush and connections in alternator (k) Checking and tighting of all connection in DC control wiring. (l) Checking of all radiator rubber hose and replacement if required. NOTE : Hose pipes shall be measured and paid separately (m) Checking and recording oil pressure, water and oil temperature (n) Checking anti vibration mounting and replacement if required. NOTE: Anti vibration pad shall be measured and paid separately. (o) Checking throttle linkage (p) Checking battery for cell test, electrolyte level, gravity and topping up to required level (q) Routine check / repair work of panel, switch, MCCB, main switch, all contactor, engine control unit.
a) 320 KVA MAKE: CATERPILLAR Model 3406 B DITA
b) 110 / 125 KVA MAKE: Cummmins Model NT 495 G / Kirloskar Model 6R1080 TA.
c) 160 KVA MAKE: Greaves Model TBDV6 MK - I
d) 63.5 KVA MAKE: Greaves Model 3 YDC MK -III / Kirloskar Model 4R104OT
e) 15 KVA MAKE: Kirloskar Model HA 294 / Greaves Model 2 YDA
f) 40 KVA MAKE: Kirloskar Model HA 494 TC / 4R1040 / Greaves 4 YD
g) 20 / 30 KVA MAKE: Greaves Model 2/3 YWA MK-5 / Kirloskar model HA394
h) 10 / 7.5 KVA MAKE: Kirloskar Model TA 2 S-II
`B' CHECK ONCE IN SIX MONTH OR 250 HRS RUNNING OF DG SET WHICHEVER IS EARLIER Material and labour required for inspection, maintenance, servicing of DG Sets of following capacities, including items covered in `B' of DG set for smooth functioning and carriying out maintenance complete as per OEM instructions and as directed :- (a) Repeat the activities of 'A' check (b) Replacing lubricant oil Note:- Lub Oil are Paid separately. (c) Replacing lubricant oil filter element with `O' ring (d) Replacing fuel filter element (e) Replacing coolant (f) Replacing Governer oil NOTES : i) `B' check kit, coolant shall be measured and paid seperately under relevant item. ii) Lubricant oil shall be measured and paid separately under relevant item.
a) 320 KVA MAKE: CATERPILLAR Model 3406 B DITA
b) 110 / 125 KVA MAKE: Cummmins Model NT 495 G / Kirloskar Model 6R1080 TA.
c) 160 KVA MAKE: Greaves Model TBDV6 MK - I
d) 63.5 KVA MAKE: Greaves Model 3 YDC MK -III / Kirloskar Model 4R104OT
e) 15 KVA MAKE: Kirloskar Model HA 294 / Greaves Model 2 YDA
f) 40 KVA MAKE: Kirloskar Model HA 494 TC / 4R1040 / Greaves 4 YD
g) 20 / 30 KVA MAKE: Greaves Model 2/3 YWA MK-5 / Kirloskar model HA394
h) 10 / 7.5 KVA MAKE: Kirloskar Model TA 2 S-II
Supply only B' Check Kit for DG sets of following capacities:- Note : It Includes to Oil filter (1.00 Ltr/0.5 ltr), Diesel filter , by pass element
(a) DG Set 320 KVA, Auto Simulator Model No 4AB3015/D2, Make CaterPillar
b)DG Set 160 KVA, CHQ, Model No-TBDV6 MK-I, Make Greaves
c) DG Set 100/110/125 KVA (i) DG Set 100 KVA, AC Record Model No, NT 495 G, Make Cummins (ii)DG Set 100 KVA, SAW office, Model No KG 225L, Make Kirlosker (iii) DG Set 100 KVA , Armament wing, Model No KG 225L, Make Kirlosker (iv) DG Set 110 KVA , MH, Model No 4 AB 250/H2 , Make Cummins (v) DG Set 100 KVA, NFS, Model No AL6DTIG1, Make Ashok Leyland
d) DG Set 63.5 KVA (i) DG Set 63 KVA , Sadle Back, Model No-4R1040T, Kirlosker (ii) DG Set 63 KVA , AC Record, Model No-4R1040T, Kirlosker (iii) DG Set 63.5 KVA , Student officer Mess, Model No-3YDC MK3, Greaves (iv) DG Set 63.5 KVA , Bhingar Nala, Model No-NRF225/2, Greaves
e) DG Set 40 KVA (i) DG Set 40 KVA, Snob Height, Model No-NB200M, Kirlosker (ii) DG Set 40 KVA, Armament wing, Model No-KG20051, Kirlosker (iii) DG Set 40 KVA, KK Range ,Model No-KG20051, Kirlosker (iv) DG Set 40 KVA, KK Range ,Model No - S3804, cummins (v) DG Set 40 KVA , Signal Centre, Model-KG20051, Kirlosker (vi) DG Set 40 KVA , A & E Regt, Model No- KG 2R 160M,Kirlosker, HA-494
f) DG Set 20/25/30KVA (i)DG Set 30 KVA , Station HQ, Model No-KG 1884C, Kirlosker (ii) DG 25 KVA, AC Depot, Model No-NB1801, Greaves (iii) DG 25 KVA, New KLP Sub Stn, KG 184B, Kirlosker (iv) DG 25 KVA , MDC, Model No-3R1040T G1, Kirlosker (v) DG 20 KVA, Armament wing HA394, Kirlosker (vi) DG 20 Kva, kk Range, Model No-G2S160-SG,Greaves (vii) DG 20KVA ,DMR Simulator, model No-GATG-339 Greaves
g) DG Set 15 KVA (i) DG Set 15 KVA, 33 KV Substation, Model No-G-15/ANB), Kirlosker (ii) DG Set 15 KVA , TTSE, Model No NB 1805 Greaves (iii) DG 15 KVA, BTR, Model No-2YWA, Greaves
h) DG Set 10/7.5 KVA (i) DG Set 10 KVA , Exchange, Model No-TA2SR2, Kirlosker (ii) DG Set 7.5 KVA , Stn Officer Mess, Model No-4D62/3,Kirlosker
Disconnecting all the connections from alternator of DG Set of Capacity 110 KVA removing the alternator from foundations , transporting to workshop, dismaintling completely including starter, roter, removing rotor and bearing clening all the parts with thinner and varnishing completely with F class varnishing, applaying expoxy coating, reassembling , dynamically balancing the alternator transporting and fixing on frame and reallignment within tolerance limit , connecting the alternator with all connections and testing on load completely all as directed.
All as per Item No 4 above but 62.5 KVA
All as per Item No 4 above but 40 KVA
All as per Item No 4 above but 25 KVA DG Set
All as per Item No 4 above but 15/20 KVA DG Set
M & L for replacement of defective spare parts of DG Sets of capacity 320 KVA, Model : 4AB 315/D2 Make : Caterpillar including connecting and testing all as specified and directed.
(a) Radiator Hose Pipe Set
(b) Air filter (inner & Outer)
(c ) Oil pressure gauge
(d) Anti vibration Pad
(e ) Water Pump assembly
(f) Turbocharger repair Kit
(g) Startor Button
M & L for replacement of defective spare parts of DG Sets of capacity 160 KVA, Model : GIR 250 MB Make : Greaves including connecting and testing all as specified and directed.
(a) Fuel Pipe
(b) Air filter (inner & Outer)
(c ) V Belt
(d) Water Pump Kit
(e ) Volt meter
(f) Amp Metre
M & L for replacement of defective spare parts of DG Sets of capacity 125 KVA, Model : CALED 80 Make : Greaves including connecting and testing all as specified and directed.
(a) Air filter
(b) V belt
© Fuel Pipe
(d) Battery terminals
(e ) Battery Lead (Red & Black)
M & L for replacement of defective spare parts of DG Sets of capacity 100 KVA, Model : KG 225L Make :Kirlosker including connecting and testing all as specified and directed.
(a) Air filter inner Cat No: 6H 411 02 0. 00
(b) Air filter assembly , Cat Part No : 6H411 10. 0 .00
© Batterty Lead
(d) V Belt
(e ) Engine RPM Cum Hrs Meter
(f) Oil Seal
(g) Binjo bolt for pipe
M & L for replacement of defective spare parts of DG Sets of capacity 100 KVA, Model : NT 495G Make :Cummins including connecting and testing all as specified and directed.
(a) Air filter Inner
(b) Turbo charger repair Kit
(c )Water Pump Assembly
M & L for replacement of defective spare parts of DG Sets of capacity 63 KVA, Model :KG 225S and Type 4R 1040T Make :Kirlosker including connecting and testing all as specified and directed.
(a) Air Filter
(b) V Belt
© Battery Lead
(d) Battery terminals
(f) Ferq Meter
(g) Hose Pipe Set
M & L for replacement of defective spare parts of DG Sets of capacity 63 KVA, Model GIR 20OSL & NRF 225/2 Make :Greaves including connecting and testing all as specified and directed.
Oil Pressure gauge
RPM Gauge
Amp Metre
Set of Coupling
Oil Seal
M & L for replacement of defective spare parts of DG Sets of capacity 40 KVA,Type 4R 1040 Make :Kirlosker including connecting and testing all as specified and directed.
Air filter
V Belt
M & L For welding / brazing of silencer pipe of of DG Set
M & L for replacement of defective spare parts of DG Sets of capacity 40 KVA,Model- S 3804 & NB 200M Make :Greaves including connecting and testing all as specified and directed.
Oil Pressure gauge
RPM Gauge
Amp Metre
Engine upper Gas Kit
Air filter
M & L for replacement of defective spare parts of DG Sets of capacity 25 KVA,Model- KG- 184B Make : Kirlosker including connecting and testing all as specified and directed.
Hose pipe
Fuel Pipe
Air filter
M & L for replacement of defective spare parts of DG Sets of capacity 25 KVA,Model- NB 1801 Make : Greaves including connecting and testing all as specified and directed.
Coupling
Oil Seal
Radiator Core
Fan Belt
Fuel Pipe
Air filter assembly
M & L for replacement of Main Panel board with starting push botton , RPM Metre, Oil pressure gauge etc of DG Set 15 KVA Model No- 2YWA, Greaves
M & L for replacement of following parts of DG Set 15 KVA Model No- 2YWA, Greaves
Bty Charger alternator
Piston Set with piston ring
Dismantling of fuel injection pump assembly complete from the engine of following capacity of DG Sets , replacement of valve , washers etc assembling, calibiration , setting for proper function ,refixing and testing for:
(a) 320 KVA capacity , Auto Simulator
(b) 160 KVA Capacity , CHQ
(d) 100 KVA, MH, SAW, Armament wing, NFS
(e ) 63 KVA , Saddle back, Arjun Mess, Bhingar Nala,
(f) 40 KVA , KK Range, A&E regt, Armament wing, Snob Height,
(g) 25 KVA , Stn HQ, AC Depot,
(h) 20 KVA, Amn Dump, KK Range, DMR Simulator,Armament wing
(j) 15 KVA, TTSE, BTR, OLD 33 KV Substn
(k) 10 KVA/ 7.5 KVA Exchange and Stn Officer Mess
Dismantling of fuel injector assembly complete from the engine of following capacity of DG Sets, reconditioning/ serving, replacement of pim spiral, washers, Cup injector,retainer, Cup screwetc assembling calibiration, setting for proper function refixing and testing for:
(a) 320 KVA capacity , Auto Simulator
(b ) 125 KVA , Nagar wala Road
(c ) 100 KVA, MH, , SAW, ,NFS
(d) 63 KVA , Saddle back, Arjun Mess, Bhingar Nala,
(e) 40 KVA , KK Range, A&E regt, Armament wing, Snob Height,
(f) 25 KVA , Stn HQ,33 KV New KLP, AC Depot,
(g) 20 KVA, Amn Dump, KK Range, Armament wing
(h) 15 KVA, TTSE, BTR,
(k) 10 KVA/ 7.5 KVA Stn Officer Mess
Dismantling , removing the self startor from the engine of following capacity DG Sets , opening up , over hauling/ servicing, replacement of carbon brushes with holders assembling back, refixing and testing for proper function :
(a) 320 KVA capacity , Auto Simulator
(c ) 125 KVA , Nagar wala Road
(d) 100 KVA, MH, AC Record, Armament wing,NFS
(e ) 63 KVA , Saddle back, Arjun Mess, Bhingar Nala,
(f) 40 KVA , KK Range, A&E regt, Armament wing, Snob Height
(g) 25 KVA , Stn HQ , AC Depot,
(h) 20 KVA, Amn Dump, KK Range, DMR Simulator,Armament wing
(j) 15 KVA, TTSE, BTR, OLD 33 KV Substn
Dismaintling, removing the alternator /dynomo of from the engine of following capacity of DG Sets , opening up over hauling servicing, replcement of carbon brushes with holders, assembling back , refixing and testing for proper function.
(a) 320 KVA capacity , Auto Simulator
(b) 160 KVA Capacity , CHQ
(c ) 125 KVA , Nagar wala Road
(d) 100 KVA, MH, AC Record, SAW, Armament wing,NFS
(e ) 63 KVA , Saddle back, Arjun Mess, Bhingar Nala, AC Record
(f) 40 KVA , KK Range, A&E regt, Armament wing, Snob Height, Old Exchange, New Exchange
(g) 25 KVA , Stn HQ,33 KV New KLP,MDC, AC Depot,
(h) 20 KVA, Amn Dump, KK Range, DMR Simulator,Armament wing
(j) 15 KVA, TTSE, BTR, OLD 33 KV Substn
Dismaintling, radiator assembly from the engine of following capacity of DG Set by disconnecting inlet and out let connections , overhauling/ servicing the radiator , clearing, removing blockages arresting leakages, assembling back incl necessary welding brazing as required , refixing , reconnecting and testing for proper functioning :
(a) 320 KVA capacity , Auto Simulator
(b) 160 KVA Capacity , CHQ
(d) 100 KVA, MH, AC Record, SAW, Armament wing,NFS
(e ) 63 KVA , Saddle back, Arjun Mess, AC Record
(f) 40 KVA , KK Range, New Exchange
(g) 25 KVA , Stn HQ,33 KV New KLP,MDC, AC Depot,
(h) 20 KVA, ,Armament wing
Dismaintling and removing of fuel tanks MS any size / type by disconnecting of fuel pipes connection , draining out of oil from the tank , replacement of all fuel pipe line PVC Connection with new highly transparrent PVC flexible of suitable diameter , painting of outer surfaces of DG sets including fuel tank with synthetic enamel paint , one coat after cleaning scrubing the surfaces incl wrirting by paint the capacity , marking of fuel level indicator etc complete for following DG Sets.
(a) 320 KVA capacity , Auto Simulator
(b) 160 KVA Capacity , CHQ
(c ) 125 KVA , Nagar wala Road
(d) 100 KVA, MH, AC Record, SAW, Armament wing,NFS
(e ) 63 KVA , Saddle back, Arjun Mess, Bhingar Nala, AC Record
(f) 40 KVA , KK Range, A&E regt, Armament wing, Snob Height, Old Exchange, New Exchange
(g) 25 KVA , Stn HQ,33 KV New KLP,MDC, AC Depot,
(h) 20 KVA, Amn Dump, KK Range, DMR Simulator,Armament wing
(j) 15 KVA, TTSE, BTR, OLD 33 KV Substn
(k) 10 KVA/ 7.5 KVA Exchange and Stn Officer Mess
S & F autometic voltage regulator of following capacity complete all as specified and directed by Engr-in-Charge
(a) 25 KVA to 125 KVA
Material and labour for replacement of unserviceable battery 12 V, 180 AH with maintenance free battery 12 Volt initially charged. Make - Exide cat No FXP0-MHD1800or equivalent makes mentioned in list of makes in Appendix ` C'
Supply only coolant, K cool Supper plus 50-50 Premix,
Supply only battery water with electrolyte mix
Supply only engine oil 15w40 turbo synthetic superior quality engine oil
Supply and fixing in replacement of expansion ballow for DG set upto 160KVA
M & L for replacement of Door Hinges of various capacity of DG Set
Labour only for perodical maintenance , brake down on call repairs of EOT Crane 2 Ton long travel motor , cross travel motor , gear box , control panel etc. installed at armoured static work shop including dismaintling/replacing the unserviceable spair parts at site complete all as specified and directed. Note:- Rate includes greesing, cleaning, oiling etc.
All as per Item No 211 (here-in-before) but 2.5 Tons
All as Per Item No 211 (here-in-before) but 3.5 Ton
All as per Item No 211 (here-in-before) But 10 Tons Note For Item No 211 to 213
(a) Maintenance of cranes required to be done in every month which includes cleaning, greasing, , oiling, which ever required, checking of all electrical connections and standard maintenance as recommended by manufacturer . (b) Spare Parts replaced, Oil, Lubricants (except Grease ) required will be measured and paid separately. (c ) Load test carried out in the presence of Engr-in-Charge and users on every month after periodical maintenance (d) contractor shuld attend day to day complaint of crane regularly and maintenance shall be carried out accordingly for smooth functioning and the cost for the same shall be deemed to be include in the above quoted rates.
Supply only spare parts suitable for EOT Crane of capacity of 2.0 ton to 10 Ton.
(a) Wheel with pin shaft
(b) Ball bearing (Bearing No-6207)
(c ) MS Gear for wheel
(d) Steel wire rope multi stranded 10mm, Make Usha Martin
(e ) PVC Coated & PVC Insulated copper conductor multistranded of size 10 sqmm 4 core
(f) HRC fuse link 32 amps as per site requirement
(g) Gear box Oil EP -230
(h) Brake Oil
(j) Brake Shoe of 150mm dia
(k) Magnetic Coil
(l) Limit switch 3 phase 415 volt 50 Hz as per site requirement
(m) Four Pole Contactor Ac Three phase 415volt Amps as per Site requirement
(n) Carbon brushes for clutch for microw movement of EOT Crane
(o) Current collector complete as per existing for EOT Crane of different capacity of EOT Crane
M & L for taking down Gearbox assembly of any capacity of Crane for long travel mechanism , short travel mechanism, updown mechanism , refixing the same after over hauling completely by replacing Gear oil C-600, Gasket set , bushing etc all as directed. Note: Gear Oil is paid separately and gasket set , bushing etc include the quoted rates.
Taking down and Material and labour for rewinding of electric motor 2HP/415,3HP/415volt,and 5HP/415 volt by using SE Copper wire same gauge and same turns incl varnishing heating, balancing etc from short travel/ long travel mechanism and refixing the same by replacing bearing, varnishing etc all as directed by Engr-in-Charge.
Taking down and Mateerial for rewinding of electric motor 10HP/415 volt by using SE Copper wire same gauge and same turns incl varnishing heating, balancing etc from short travel/ long travel mechanism and refixing the same by replacing bearing, varnishing etc all as directed by Engr-in-Charge.
Material for repairing to long travel shaft by replacing pedstal bearing 06 Nos, including machining work replacing nut, bolts ,washers all as directed by Engr-in-Charge. Note:- Pedastal Bearing is measured and paid separately.
Material for repair to brake system completely by replacing brake shoe , rotor , brake liner , spring for long travel, short travel, updown mechanism all as directed by engr-in-charge. Note:- Break shoes is measured and Paid Separately
Repairs to guide wheel 4 Nos for long Travels by replacing gun metal filling , reboring and machine work with in tolerance limit all as specified and directed.
Material for periodical maint of oil fired incinerator of Make : HAAT Model GD-3once in three month which includes the following works. (a) Descalling of Gap between greads (b) Descalling of combution Chamber (c ) Descalling of arch chamber (d) Descalling of stack arrester. (e ) Overhauling burner nozzel blast tube pump, diffuser etc (f) Cleaning of Diesel tank and fuel lines Note:- (i)Rate Includes for painting on Diesel Tank and writing in White Paint Date of Cleaning and capacity. (ii) contractor shuld attend day day complaint of Incenarator regularly and maintenance shall be carried out accordingly for smooth functioning and the cost for the same shall be deemed to be include in the above quoted rates.(iII) Parts are measured and Paid separately.
Supply Only following Parts :-
(a) Ignition electrode, Cat Part No-HTT09/83
(b) Ignition Transformer 200-6000Volt, Cat Part No-HTT09/83
© Diffuser plate, Cat Part No-HTT06/83
(d) Solenoid Valve Cat Part No-VAL 0029/5
(e ) Fuel Pump Assembly Cat Part No-HT001/9
(f) Fuel Suction Filter assembly, Cat Part No-HA2/3
(g) Combution Blower Cat No-HTT 11/83
(h) Solenoid coil for combution blower, Cat Part No-VA-0320/9
(j) Sequence Controller, Cat Part No-HTT 22/G3
M & L for periodical maint of washing Machine and Dryer DER-30 and Dryer Thumbler once in three month which includes the following works. (a) Descalling of drying chamber by descalling solution MAC (b) Oiling , Greasing of bearing of moters and shaft (c ) Laying and tighting of panel wiring with proper thinbles/ PVC Clampr (d) Overhauling of washing machine Chamber Note:- (i)Rate Includes for writing in White Paint Date of Cleaning and capacity. (ii) contractor shuld attend day day complaint of Machine regularly and maintenance shall be carried out accordingly for smooth functioning and the cost for the same shall be deemed to be include in the above quoted rates.(iII) Parts are measured and Paid separately.
Supply Only following Parts :-
a) V Belt size A-69
b) HRC Fuse up to 32 Amps
d) Hose pipe for Drain 1.2 Mtr Length
e) Water Solinied Valve 1''
f) Conatctor 3 Phase 63 Amps for starter of main drive moter
g) Heating Contactor
j) Electric heater
k) Idler Shaft
l) sequence Ciontroler
m) ignition Transformer
n) Air Filter Cum Regulator
O) Single Phase Prevainter
p) Drying Thumbler timer
Q) Tension Spring
r) Breaking contactor
M & L for rewinding of 3 Phase electric motor including varnishing of washing machine main drive 3 HP incl taking down and reinstalling at site incl connecting electric point and commissioning complete al as specified.
M & L for periodical maint of Air Compressor once in three month which includes the following works. (03 Nos of Air Compressor) (a) Checking the compressed air pipe for leakage. (b) Checking of V belt and repair and replace it (c )Oil, Greasing of bearing of moters and shaft (d) Checking of pressure valve switch for automatic control of compressor. e) Checking of non return valve of compressor and if damage repair it. f) Overhauling of compressor moter g) Tighting and cheking of panelwiring with proper thimble (h) Painting of Air compressor with with synthetic enamel paint , one coat after cleaning scrubing the surfaces incl wrirting by paint the capacity , marking of fuel level indicator etc complete as directed by Engineer in charge. Note:- (i)Rate Includes for writing in White Paint Date of Cleaning and capacity. (ii) contractor shuld attend day day complaint of Machine regularly and maintenance shall be carried out accordingly for smooth functioning and the cost for the same shall be deemed to be include in the above quoted rates.(iII) Parts are measured and Paid separately.
Supply Only following Parts :-
a) V Belt suitable for Air compressor to motermain drive Pully
b) Compressed Air Pipe of 10mm Dia of Heavy Duty
c) Head Gas Ket
d) Piston Ring
e) Connecting Rod
f) Oil Seal
S & F DOL Starter of Air Compressor moter Main Drive 3 HP Incl taking down and reinstalling with new starter 415 volt 50 cycle current rating 8 Amps incl connecting to electric point and commissioning etc complete all as directed.
M & L for repair and replacement of AMF Panel for 160 KVA DG Set make : Greaves
Supply Only for replacement of following Parts :-
(a) AMF Controller
(b) Contactor 4 Pole 415 Volt 225 Amp, Make: L&T/Seimens
(c ) Bty Charger 24 Volt 20 Amp
(d ) Digital multifunctional meter for freq, Amp, Voltage, KWH
(f) Voltage Monitoring relay
M & L for periodical maint of car washing point once in three month which includes the following works. (03 Nos of car washer motor) (a) Checking the motor in regular basis. b) winding of motor Note:- (i) contractor shuld attend day day complaint of Machine regularly and maintenance shall be carried out accordingly for smooth functioning and the cost for the same shall be deemed to be include in the above quoted rates.(iII) Parts are measured and Paid separately.
M& L for repairing of 100 KVA DG Panel (Make: Ashok Leyland) by repacing necessary electric items such as MCB, Contactor etc and rewiring all the connnections and also replace electronic panel showing parameters i.e Oil Pressure, Water Temp, RPM, Frequency, Volt Amp, starting switch etc.
Material and labour for replacement of unserviceable battery 12 V, 92 AH with maintenance free battery 12 Volt initially charged. Make - Exide or equivalent as approved by GE
Supply and fixing in existing panel board for replacement MCCB, 4 Pole, 63 Amps , with breaking capacity 16 KA , fixed type and connecting etc complete all as specified and directed by Engineer-in-Charge MAKE: Legrand or its equvalent.in makes mentioned in list of makes in Appendix `C'
Supply and fixing in existing panel board for replacement MCCB, 4 Pole, 100 Amps , with breaking capacity 25 KA , fixed type and connecting etc complete all as specified and directed by Engineer-in-Charge MAKE: Legrand or its equvalent.in makes mentioned in list of makes in Appendix `C'
Material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to GI strip 32 x 6 mm , by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion etc complete all as specified and directed by Engineer-in-Charge Note:- i) Cost of GI strip 32 x 6 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii) Excavation and returning filling of Soil any type is deemed to be included in rates.
An amount of Rs 1,06,191.00 shall be deducted from BOQ on account of schedule of credit
Maruti Abhiyantriki
KAMINS CARE
Ms. S.K. ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .