GE AF TUGHLAKABAD
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
REPAIR/MAINT OF STP AND SEWAGE INSTALLATION AT 7BRD UNDER GE (AF) TUGHLAKABAD
2022_MES_535372_1
GE/TKD-27/2022-23
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF TUGHLAKABAD
MES contractor enlisted having deposited Standing Security with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
8 documents required · 8 mandatory
₹500
GE AF TUGHLAKABAD
₹50,000
Yes
24 Sept 2022
13 Jul 2022
12 Aug 2022
20 Jul 2022
10 Aug 2022
27 Jul 2022
Amount
Periodical cleaning of equalizing tank/grit chamber/oil grease chamber/stilling chamber of Sewage water and removing by scrapping with wire brush or any other means from walls and bottom of tank and removing the sludge/silt/fungus deposited inside the sumps and tank with buckets and depositing where directed including removing media of settled down and making good the disturbed surfaces of walls internally or externally in cement mortar (1:3) as required and followed by cleaning with bleaching water solution and fresh water and finaly applying one coat of snowcem on internal and external surfaces including writing the date of cleaning and due date of cleaning in white colour on black background on external walls complete all as specified and directed by Engr-in-charge. (Location: 7BRD STP and capacity 250/300 KLD.) Note: The rate quoted by the tenderer is deemed to be included in the unit rate for the following aspects:- (a) Diesel driven pump set of appropriate capacity with operators including necessary POL required at site for de-watering of sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purpose. (b) Lorry or tractor mounted storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved by the MCD. (c) Necessary oxygen mask, gloves, gum boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc required at site shall be arranged by the contractor.
All as per item No 01 but cleaning of MBBR-1 and MBBR-2 of Sewage treatment plant capacity 250/300KLD.
All as per item No 01 but cleaning of Tube settler/lamella clarifier of Sewage treatment plant capacity 250/300KLD.
All as per item No 01 but cleaning of Treated water tank with chemical contact tank of size upto capacity 250/300KLD.
M&L for cleaning and desiIting the sewage well of capacity, dewatering the complete well of 100 to 125 Cum removing all the deposited sludge, soil and other material from the well including bailing / pumping out muddy water from the well by manually or by providing suitable pump sets from bottom level of well, scrapping out the scales / deposits from inner surface of the well thoroughly, washing with bleaching powder and soda ash, cleaning / bailing out settled materials completely by any means and removing sludge to a distance up to 3 km out side of defence land limit and dispose off in low lying area including dewatering as required. Note:- (i) Contractor is to arrange own diesel pump, T&P etc for cleaning purpose and minor spares and consumable like small screws, washers, cleaning agents consumables etc is deemed to be included in the cost, the unit rate quoted deemed to be include all safety precautions to be taken while working in Lift well. (ii) The accumulated/deposited sludge after drying shall be disposed off out side the defence land to a distance exceeding 1.5 KM and not exceeding 5.00 KM from the Lift well cost of which shall be deemed to inclusive in the quoted rate and nothing extra shall be paid on this account. (iii) Before commencement of work, necessary arrangement for disposal of sewage/sludge be made and work to be carried out in fast pace by deploying more man power at lift well in order to complete the work at the earliest.
Supply only Powdered Chlorine dioxide disinfect for water treatment more stable than bleaching powder and sodium hypochlorite. Make- SCS-10K (CLO2)/Altoch
M&L for replacement of Unsv MBBR Media from the tank and supply of filling Fresh media of MBBR Media in the main reactor as specified of existing /suitable Make with the following specificatios:- Effective surface area of media Approx - 400 Sqm/Cum (b) Mesdia ht Approx - 15/10 mm (c)Media dia Approx- 22 mm (d) Weight per unit surface area approx -22 mm (e) Voidage - >093 gm/Cucm (g) Media fill Range - 25-55% of volume
M&L for replacement of Hybrid Bio-Cultured (Synthetic Bacteria) suitable for STP 250/300 Cum/day complete all as specified and directed by Engr-in-charge.
Material and labour for replacement of activated carbon IV 1000, granular type complete all as specified and directed by Engr-in-charge.
Supply and mixing of Dewatering Poly Electrolite 100 % Purity complete all as specified and directed by Engr-in-charge. Make : ION Exchange/Rayal Seema/Aqua/Thermax
Supply and mixing Calcium Hydro-Oxide (Lime, 80-85%) in Powder form as pH Booster for STP water, packing in 40 Kg Packs complete all as specified and directed by Engr-in-charge. Make : ION Exchange/Rayal Seema/Aqua/Thermax
Supply and mixing Ortho Tolidin solution for testing of dissolved chlorine in water complete all as specified and directed by Engr-in-charge. Make : ION Exchange/Rayal Seema/Aqua/Thermax
Supply and mixing Chlorination testing glass test Tube kit complete all as specified and directed by Engr-in-charge. Make : ION Exchange/Rayal Seema/Aqua/Thermax
Supply and mixing Alum Ferric (Grade-4) (best quality as per sample) for purification of water (containing lead (as PB) 30 ppm Max and arsenic 6 ppm Max) confirming to IS-299/2012 (Revised) as amended upto date complete all as specified and directed by Engr-in-charge. Note :- The Alumino Ferric Sulphate shall be supplied in superior quality bricks (slabs) as per IS specifications. Manufacturers Name/trade mark shall be engraved on each brick (slab) in addition to marking of relavant clause of IS specification.
Supply and mixing bacteria culture airobic in 30 Kg of drum complete all as specified and directed by Engr-in-charge.
Supply and mixing DAP fertiliser for day to day use in sewage treatment plant complete all as specified and directed by Engr-in-charge.
Supply and mixing molasses for day to day use in Sewage treatment plant complete all as specified and directed by Engr-in-charge.
Supply and mixing PAC (Poly Aluminium Chloride AC 1005 in organic soluable Polymer Powder packed in 25 Kg Poly bags complete all as specified and directed by Engr-in-charge.
Carrying samples for testing of treated water of STP and submission of detailed test report to the office of the Engr-in-charge for the following aspects:- (a) Carrying out minimum essential testing of water as per IS-3025 & IS-1622 mandatory for chemical, colour, odour, PH value, TSS, BOD, COD, Total residual chlorine, total nitrogen, sulphate, oil and grease, anmmonical nitrogen (NH3-N) and bacteriological total coliform organism per 100 ml (MPN) and ecoli in 100 ml. (b) Treated sewage water shall confirm to the following characteristics:- (i) TSS < 10 mg/litre (ii) BOD < 10 mg/litre (iii) COD < 150 mg/litre (iv) Ph: 6.5 to 8.5 (v) Total coliform < 100 MPN/100ml (desired nil) (vi) Residual CI > 1 mg/litre Rest of the characteristics of the treated water shall be as per IS-3025 & IS-1622 Note: Cost of sterlized bottle and to and fro transportation charges for collection of samples shall be included in the quoted rates.
M&L in replacement of pressure gauge to read in IS/BS unit type Range 0-7.5 KG/cm2 and LB/inc2 reading marked 0-2, 0-30 respectively including taking old one complete all as specified and directed by Engr-in-charge. Make:- H Guru or equivalent ISI Marked.
M&L for cleaning, scrapping out of surface and painting of all pipe lines with two coat of primer as approved colour with two coat of synthetic enameled paint complete all as specified and as approved by Engr-in-Charge. Make of paint- Berger/Shalimaar/Asian
M&L for cleaning, scrapping out side of vessel properly including painting with one coat zinc chrome primer & two coats of best quality synthetic enamel paint etc. Make of paint- Berger/Shalimaar/Asian
M&L for complete repairing of multigrade Pressure sand filter including replacement of filter media as per existing including other connected assessories as required at site of STP capacity 250/300KLD including testing complete all as specified and directed by Engr-in-charge.
S&F in replacement Moulded case circuit Breaker of capacity , 400 Amps, 04 pole, 415 Volt, 36 KA Breaking capacity, with adjustable thermal & adjustable magnetic setting complete all as specified and directed by Engr-in-charge. Make : Havells/Legrand/L&T
M&L in replacement Moulded case circuit Breaker of capacity, 250 Amps, 04 pole, 415 V, 36 KA Breaking capacity, with adjustable thermal & adjustable magnetic setting complete all as specified and directed by Engr-in-charge. Make : Havells/Legrand/L&T
M&L in replacement MCCB 200 A, 4 Pole, 415 V, 36 KA Breaking capacity, with fixed thermal magnetic release complete all as specified and directed by Engr-in-charge. Make : Havells/Legrand/L&T
M&L in replacement MCCB 100 A, 4 Pole, 415 V, 25 KA Breaking capacity, with fixed thermal magnetic release complete all as specified and directed by Engr-in-charge. Make : Havells/Legrand/L&T
M&L in replacement Moulded Case Circuit Breaker (MCCB) (AC 415 V) with fixed thermal magnetic release 4 pole 63 Amp 16 KA complete all as specified and directed by Engr-in-charge. Make : Havells/Legrand/L&T
Dismantling the unserviceable part of sewage treatment compressor blower and replace with including testing after completion all as specified and directed by Engr-in-charge.
S&F in Replacement Suction filter suitable for sewage treatment 250 KLD /300 KLD compressor blower complete all as specified and directed by Engr-in-charge. Make: Everest or equivalent ISI marked.
S&F in Replacement bearing suitable for sewage treatment 250 KLD/ 300 KLD compressor blower complete all as specified and directed by Engr-in-charge. Make: Everest or equivalent ISI marked.
S&F in Replacement gears with Hub complete with hardware suitable for sewage treatment 250 KLD/300 KLD compressor blower complete all as specified and directed by Engr-in-charge. Make: Everest or equivalent ISI marked.
S&F in Replacement V- Belt suitable for sewage treatment 250 KLD/ 300 KLD compressor blower complete all as specified and directed by Engr-in-charge. Make: Everest or equivalent ISI marked.
S&F in Replacement gear oil No-90 suitable for sewage treatment compressor blower complete all as specified and directed by Engr-in-charge. Make: Castrol or equivalent ISI marked.
S&F in Replacement oil seal and gasket set suitable for sewage treatment compressor blower for 250 KLD complete all as specified and directed by Engr-in-charge. Make: Everest or equivalent ISI marked.
S&F in Replacement Set of rotor with shaft for sewage treatment compressor blower for 250 KLD complete all as specified and directed by Engr-in-charge. Make: Everest or equivalent ISI marked.
S&F in replacement Silencer suitable for Everest Blower complete all as specified and directed by Engr-in-charge. Make: Everest or equivalent ISI marked.
M&L in replacement Jet mixer nozzles of size 25 mm for equilizer tank of STP complete all as specified and directed by Engr-in-charge. Make: Everest or equivalent ISI marked.
Supply and fixing in replacement of pre-fabricated MS structural steel (IS marked) work consisting of channels / angles /flats/ round bars/MS pipe & other sections etc of various sizes and shape, cut / weld / drilled holes etc hot / cold in position for cross arms with FI clamps (full, half D and earth clamp etc) incl necessary MS bolts, nuts etc and painting for hanging strcture for repair bay all as directed by Engr in Charge.
S&F in replacement Submersible cable PVC insulated copper conductor flat 3 core 6 sqmm 1100 volt complete all as specified and directed by Engr-in-charge. Make-Havells, Finolex, Plaza
S&F in replacement Direct on line submersible pump starter of capacity 7.5 HP (5.5 KW) current rating 18 Amp overload relay range 10-16 Amp complete all as specified and directed by Engr-in- charge. Make- Havells cat Part No IHSDOANB*A /L&T/BCH
Supply and lay in replacement or fixing or passing through pipe cable XLPE with aluminium conductor with heavy duty stranded,1100 volts of following size. Note:- XLPE insulated pvc sheathing (heavy duty) armoured cable with aluminium conductor for working pressure up to and including 1100 volts to IS -7098 (Part-I) for pvc insulated cables size 3 core 6 sqmm. Make of cable : Havells/Polycab/Universal
M&L in replacement for electronic type timer ST 100 type 110/240 V, 50 Hz for 3-30 secs Complete all as specified and as directed by Engr-in-Charge. Make- L&T cat Part No- ST80328OOOO, Havells
M&L in replacement for single phase preventer for 415 V, 50 Hz, Complete all as specified and as directed by Engr-in-Charge. Make-Minilec, L&T
S&F in replacement CI impeller suitable for Non clogging centrifugal pump 40 HP complete all as specified and directed by Engr-in-charge. Make- Kirloskar
All as per srl item no 42 above but 20 HP
Lowering/Lifting/disconnecting the electric and water pipe connection for taking out burnt non clogging submersible pumping set of capacity upto 12.5 HP by using tripod & chain pulley arrangement from sewage sump at a depth of approx 18 feet by dismantling column pipe flanged joint for carrying out necessary repair including transportation of pumping set to civil work shop for repair and return to site after repair including testing all as specified and directed by Engr-in-charge.
M&L for taking out the Non clogging submersible pump 12.5 HP from the motor and rewinding of motor with super enameled copper wire including removing burnt winding cleaning of slots separation of rotor and starter making insulation to all joint including replacement of following items:- (a) Replacement of both side ends cover and machining to size of ball bearing. (b) Replacement of driving and nondrying end ball bearing. (c) Balancing of rotor including straightening of strips. (d) Assembling of motor including replacement of copper lead.
All as per srl item no 44 above but 5 HP
All as per srl item no 44 above but 3 HP
Opening of Non-clogging Submersible pump 12.5 HP for repair and replacement of following u/s parts including re-fixing of all the same and testing and commissioning complete all as specified and directed by Engr-in-charge. (a) Replacement of cast iron impeller. (b) Replacement of bearing plate. (c) Replacement of gun metal bush. (d) Replacement of oil seal.
All as per srl item no 45 above but 5 HP
All as per srl item no 45 above but 3 HP
S&F in replacement of Cast iron sluice valve of size 150 mm dia Stainless steel stem PN- 1.6 ( Flanged) conforming to IS 14846 hand wheel operated including taking down old one all as specified and as directed by Engr-in-Charge. Make - Zolato /Kirloskar/Kartar
All as per srl item no 46 above but 100 mm
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 25mm X 4 mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt all around earth plate, test point of phosphorous bronze / gun metal of size 75 mmx 75 mm x25 mm, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI medium grade earth lead protection pipe, complete all as specified and directed. Note: Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
S&F in replacement of cast iron NRV flanged end of size 100 mm dia with all fitting and accessories including taking down old one all as specified and as directed by Engr-in-Charge. Make- Zoloto /Kirloskar/Kartar
All as per srl item No 48 above but 80 mm dia. Make- zoloto /Kirloskar/Kartar
S&F in replacement of CI Butterfly valve 50 mm dia with lever operated CI Disc Nitrile/EPDM Rubber Lining test pressure PN-1.0 and ms nut bolt and washers and pair of rubber/fibers required for the work will be supplied by contractor for fixing in position complete including taking down old one all as specified and as directed by Engr-in-Charge. Make- Audcu/Zoloto/L&T
All as per srl item no 49 above but 80 mm
All as per srl item no 49 above but 100 mm
S&F in replacement of ball valve gun metal with iron wheel/handle screwed both ends for iron pipe and fixed of size 50 mm bore including taking down old one all as specified and as directed by Engr-in-Charge. Make- Zoloto/Audcu
Taking out compressor from 12.5 HP motor and rewinding of motor same gauge with super enameled copper wire including removing burnt winding cleaning of slots separation of rotor and starter making insulation to all joint and replacement of the following items complete all as specified and directed by Engr-in- charge. (a) Replacement of ball bearing. Make: SKF-02 Nos (b) Replacement of cooling fan - 01 Nos.
Taking out the 40 HP centrifugal pump from the motor and rewinding of motor same gauge with super enameled copper wire including removing burnt winding cleaning of slots separation of rotor and starter making insulation to all joint and replacement of the following items All as specified and directed by Engr-in- charge. (a) Replacement of ball bearing. Make: SKF-02 Nos (b) Replacement of cooling fan - 01 Nos.
All as per srl item No 52 above but 20 HP
All as per srl item No 52 above but 5 HP
All as per srl item No 52 above but 2 to 3 HP
Opening of pump centrifugal 40 HP for repair and replacement of following u/s parts including re-fixing of all the same and testing and commissioning complete all as directed. (a) Replacement of gun metal impeller. -01 Nos (b) Replacement of gun metal bush -02 Nos (c) Replacement of ball bearing. Make: SKF - 01 Nos. (d) Replacement of oil seal -01 Nos. (e) Replacement of gland -01 Job
All as per srl item No 53 above but 20 HP
All as per srl item No 53 above but 5 HP
All as per srl item No 53 above but 2 to 3 HP
Supply and Fixing in replacement of UPVC pipe manufactured as per ASTM-D-1785 as per IS-559, Schedule-80, pressure rating 10kgf/ cm2 complete with all types of fittings, laid in trenches, wall etc in required length of the inner bore sizes 25 mm dia complete all as specified and directed by Engr-in-charge. Make:- Astral/Prince and equivalent
Supply & laying in replacement of MS pipe (Heavy duty Class 'C') including fitting as required of 100 mm dia pipe sizes laid in treches or laying on floor for connecting to various STP accessories and to connect outgoing water main including taking down the unserviceable pipe and depositing to MES store yard complete all as specified and directed by Engr-in-charge. Note:- MS flange and flange joint complete with jointing material shall deemed to be included in the unit rate.
Supply and laying in replacement of galvanised steel water tubing medium grade in trenches / wall floor with all GI fittings like tee, socket, reducer, elbows connections as required at site of size 15 mm bore complete all as specified and directed by Engr-in- charge:- Make : Tata/Jindal
All as per Item No 56 Above but Bore of pipe 20 mm. Make : Tata/Jindal
All as per Item No 56 Above but Bore of pipe 25 mm. Make : Tata/Jindal
All as per Item No 56 Above but Bore of pipe 50mm. Make : Tata/Jindal
All as per Item No 56 Above but Bore of pipe 80mm. Make : Tata/Jindal
Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc in complete all as specified and directed by Engr-in-charge.
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point complete all as specified and directed by Engr-in- charge.
Returning filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed by Engr-in-charge.
Supply and laying in replacement of HDPE pipe 100 mm dia complete all as specified and directed by Engr-in-Charge. Make - ISI marked.
M&L for boring holes for laying of pipe manual bookey , of 200 mm dia 2 m deep in soil for under-reamed piles and getting out and disposal of spoil to a distance of n exc. 50 m Complete all as specified and as directed by Engr-in-Charge
M&L for removal of lamella clarifier fiber settling plates of lamella clarifier suitable for 250KLD STP plant complete all as specified and directed by Engr-in-Charge.
S&F in repair foot valve of size 100mm dia (Plastic body) with necessary fixing arrangement like nut , bolts washer packing sheet etc including taking out existing unserviceable foo tvalve complete all as directed at site. Make:- Prince/Astral
All as per item No 63 herein before but for 80mm dia.
All as per item No 63 herein before but for 50mm dia.
M&L in replacement of Power contactor 3 pole Type CN5 50 AC 50 Amp rating complete all as specified and directed by Engr-in-charge. Make- Havells/L&T/Siemens
M&L in replacement of Power contactor 3 pole Type MNX 32 AC 3 rating 32A complete all as specified and directed by Engr-in-charge. Make- Havells/L&T/Siemens
S&F in replacement of contactor, 3 pole, 415V, MNX 18/22/25 complete all as specified and directed by Engr-in-charge. Make- Havells/L&T/Siemens
S&F in replacement of Electronic overload relay (Manual reset) relay range 24-40 amp suitable for direct mountimg complete all as specified and directed by Engr-in-charge. Make- Havells/L&T/Siemens
S&F in replacement of Electronic overload relay (Manual reset) relay range 9-16 amp suitable for direct mountimg complete all as specified and directed by Engr-in-charge. Make- Havells/L&T/Siemens
S&F in replacement of Electronic overload relay (Manual reset) relay range 45-75amp suitable for direct mountimg complete all as specified and directed by Engr-in-charge. Make- Havells/L&T/Siemens
M&L in replacement for making Pump set foundation and pipe filling support from PCC (1:2:4), type B2 using 40mm graded stone aggregate, of any shape or size as indicated including grouting of foundation bolts of suitable dia and size as required on site complete all as specified and directed by Engr-in-charge.
S&F in replacement of pre-painted galvatume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/clading to wall, fixed with self tapping screws and bending of sheet as required and complete all as specified and directed by Engr-in-charge.
M&L in replacement for loose filling using 40 to 80 mm stone aggregate (granite) spread to a thickness of 150 mm for out door sub station complete all as specified and directed by Engr-in-charge.
M/S S.K.Electricals
M/s Hemakshi Enterprises
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .