Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹1.4 Cr+₹19.0 L (15.7%)Rejected-Finance | ₹1.4 Cr+₹19.0 L (15.7%) | L2 | Rejected-Finance L2 |
| 3 | Not Admitted-Fee/PreQual/Technical V P O JAWALAMUKHI TEHSIL JAWALAMUKHI DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 176001 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical HOSPITAL ROAD SOLAN TEHSIL SOLAN DISTRICT SOLAN HP | SOLAN | SOLAN | HIMACHAL PRADESH | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹1.5 Cr
EMD Value
₹1.9 L
Closing Date
30 Jan 2024, 11:00 amClosed
Executive Engineer
JSV Division Jubbal
Providing LIS from horticulture land Maghara and Astandli in GP Sari in Tehsil Jubbal Distt Shimla HP
2024_HPIPH_84296_1
JBL-SML-09-718
Open Tender
Civil Works
Item Rate
365 days
Sari
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,500
Yes
₹1.9 L
Yes
12 Jun 2024
19 Jan 2024
30 Jan 2024
19 Jan 2024
30 Jan 2024
19 Jan 2024
Amount
Excavation in foundations , trenches etc., in earth work , lift up to 1.50 metres. Stacking the eacavated soil not more than 3 metres clear from the edge of the excavation and then returning the stacked soil in 15 cm. (fifteen centimetres) layers , when required in to plinth and sides of foundations etc., conslolidating each of the disposited layer by ramming and watering and then disposing off all excavated soil as directed with in the load of 20 mtrs. Pick and Jumper work etc. complete as per the direction of the Engineer - in - Charge.
Excavation in earth work in all kind of soil stacking excavated soil in the plinth sides of foundation and then disposing of all surplus soil in all leads & lifts as directed by Engineer in Charge.
Providing and laying cement concrete 1:3:6 (1cement: 3 sand: 6 graded stone aggregate 40mm( Forty millimeter nominal size) and curing complete excluding cost of from work in foundation and plinth with in all leads & lifts as per entire satisfication of Engineer-in-Charge.
Providing and laying cement concrete 1:1:2 (1cement :1Sand: 2 graded stone aggregate 20 mm N/S) and curing complete excluding cost of form work and reinforcement for Rainforced concrete work in
Foundation and Plinth with in all leads and lifts as per the direction of the Engineer in Charge.
Walls (Any thickness) attached pillasters, pillasters, buttresses, beam girder and contilevers upto floor two level with in all leads and lifts as per the direction of the Engineer in Charge.
P/L CC 1:4:8 1cement:4 sand:8 graded aggregates 40mm nominal size curing complete excluding cost of form work infoundation & plinth
P/L CC 1:6:12 1cement:6 sand:12 graded aggregates 40mm nominal size curing complete excluding cost of form work infoundation & plinth
Providing & laying CC 1:2:4 1cement:2 sand 4 graded aggregates 20mm nominal size curing complete excluding cost of form work & reinforcement for RCC work in:-
foundation footing and bases of columns & like mass concrete.
Column.pillar & post upto floor two level
In suspended floor roofs landing shalves & their support balconies,beams, girders bressumers cantilevers upto floor two level
Stair cases (except spiral stair cases) excluding landing I/c preparation of surfaces
Providing and laying cement concrete work 1:1.5:3 (1cement :1.5 sand: 3 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcment for reinforcement concrete work in
Suspended Floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever up to floor two level with in all leads and lifts as per the direction of the Engineer - in - Charge.
Foundation and Plinth with in all leads and lifts as per the direction of the Engineer in Charge.
Walls (Any thickness) attached pillasters, pillasters, buttresses, beam girder and contilevers upto floor two level with in all leads & lifts as per direction of Engineer - in charge.
Providing mild steel/ tor steel reinfircement for rainforced concrete work I/C bending, binding and placing in position complete upto floor two level with in all leads and lifts as per the direction of the Engineer in Charge.
Providing from work steel plates 3.15 mm thick welded with angle iron in frame 30x30x5 mm so as to give a fair finish i/c centering, shuttering, strutting and propping etc. with wooded battens & ballies, height of propping and centring below supporting floor to ceilling not exceeding 4 meters and removal of the same for in situ reinforced concrete and plain concrete work with in all leads aand lifts as per the direction of the Engineer in Charge.
Foundation andfooting base of column & mass concrete with in all leads and lifts as per the direction of the Engineer in Charge.
Vertical surfaces such as walls (any thickness) partitions and the like including attached pillasters, buttress, plinth and string couress and the like.
Flat surfaces such as soffits and suspended floors, roofs landing and the like: Floors etc up to 200 mm in thickness .
Column, pillar & poat upto floor two level square, rectangular and polygonal in plan.
Beams, cantilevers, Girders & lintels sides and siffits of beams, hounching cantilever girder not exceeding 1 mtr. Depth.
Slopping and battering surfaces I/c folding plates where inclination to horizontal plane not exceeding 30 degrees.
Edge of slab and break in floor 20 cm wide
Stair cases (except spiral stair cases) excluding landing I/c preparation of surfaces
Steel work welded in built up sections, trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat of red lead paint etc. with in all leads and lifts as per the direction of the Engineer in charge.
Half Brick masonary using common burnt clay building bricks above plinth upto floor two level in cm 1:4(1cement:4sand)conventiohal brick first class
Providing and fixing pressed steel door, frames, manufactured from comercial mild steel sheet of 1.25 mm thickness including hinges jump block Jamb, beed, and if required angle threshold of mil steel angle of section 50x25mm or base ties of 1.25mm pressed mild steel welded or regidly fixed together by machanical means adjustable lugs with split and tails to each Jamb i/c steel but things 2.5mm thick with guards lock strike plate and shock as specified and applying a coat of applying steel primer after pretreatment of the surfaces directed by the Engineer-in-charge
Profile-A.
Profile-B.
Profile-C.
Providing and fixing Pannelled and glazed shutters for doors windows and clear storey windows including bright finish black enamel led iron butt hinges with necessary screws 40mm thick: 2nd class deodar wood.
P/F wire gause shutters using MS wire gause of IS gause designation 85 G for doors windows clerestorey windows I/c bright finished black enamelled iron hinges with necessary secrews 30 mm thick 2nd class deodar wood.
15 mm thick cement plaster on fair sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:6 (1cement:6sand)
20 mm thick cement plaster on rough sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:6 (1cement:6sand)
6 mm thick cement plaster in CM 1:3( 1cement 3 sand in roof slabs
White washing with lime on undecorated wall surfaces(two coats) to give an even shade I/c thoroughly brooming the surface to remove all dust dirt & other foreign matter.
Distempering (two coats) with oil bond distemper of approved brand and manufacture and of required shade on undecorated surfaceto give an even shade and including priming coat with distemper after throughly brushing the surface free from mortar dropping and other foreign matters.
Finishing wall with water profing cement paint of approved brand and manufacture and of rerquired shade on undecorated wall surfaces (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials.
Precast terrazo tiles 20m thick (with marble chipsof specified shadeand of specified laid in floor treads of steps and landingon bed on10mm thick cement plaster 1:6 (1cement6sand) jointed withneat cement slurry mixed with pigment to match the shade of tiles. selvary grey
In Skirting & riser ofsteps and dado incement plaster 1:3 (1cement:3sand) and jointed with white slurry. Selvary grey
Applying priming coat over new wood and wood based surfaces after and including preparing the surface by throughly cleaning oil grease & dirt and other foreigm matter
Painting two coats(excluding priming coat) on new wood and wood based surfaces with ready mixed paint brushing to give even shade including cleaning all dirt, dust and other foreign matters white paint
Painting two coats(excluding priming coat) on new wood and wood based surfaces with ready mixed paint brushing to give even shade including cleaning all dirt, dust and other foreign matters other than white paint
Providing and fixing of MS grill of required patttern in wooden frame of window etc. with MS rounded headed bolts and nuts or by screw: Plain Grill.
Stone soling properly hand packed filling interstices with spalls and consolidating with power road roller to the required gradient and camber including spreading watering and rolling of binding materials moorum or earth etc. 100mm spread thickness (finished work including materials and labour) within all leads and lifts an da directed by the Engineer-in-charge.
Providing and fixing anodized Aluminium sliding door bolts withnuts and screws complete I) 250mmX16mm
Providing and fixing anodized Aluminium. tower bolts barrel type with screws etc. complete.
I) 200mmX10mm
ii) 150mmx10mm
Providing and fixing anodized Aluminium.handles with screws etc. complete.
I)125mm dia
ii) 100mm dia
Providing 40x3 mm flat iron hold fast 40cm. Long including fixing to frame with 10mm dia metres bolts, nuts and wooden plug and embedding in cement concrete block 30x10x15cm. 1:3:6( 1cement:3sand:6 graded stone att. 20mm nominal size) within all leads and lifts and as directed by the Engineer-in-charge.
Providing plinth protection 50mm thick in cement concrete 1:3:6(1cement:3sand:6graded stone agg. 20mm nominal size) i/c finishing the top surface of concrete smooth within all leads and lifts and as directed by the Engineer-in-charge.
Providing and laying brick tiles over mumty roofs grouted with cement mortar 1:3 over a 12mm layer of cement mortar 1:3 and finished needly within all leads and lifts and as directed by the Engineer-in-charge.
Laying , jointing and testing in trenches Galvanised Mild Steel tube of the following dia metres including smooth bending by necessary bends, or through pipe bending machine with necessary all pipe fittings such as Tees, Elbows, Union & Reducers etc. of ISI marked & testing for leakage complete with in all leads & lifts as per entire satisfication of Engineer - in - charge. (Earth work in trenches to be measured and paid for separately)
100 mm dia.
65 mm dia.
50 mm dia.
40 mm dia.
32 mm dia.
Providing and replacing of copper alloy gate valve (Heavy duty) ISI marked with in all leads and lifts as per the direction of Engineer-in-Charge.
100 mm dia.
65 mm dia.
50 mm dia.
40 mm dia.
32 mm dia.
Providing, laying, testing & commissioning at site in trenches bevelled ended BIS marked API pipes confirming to IS-1978-1982 ISO- 3183-2007 or its equivalent latest with up to date ammendments of following dia with steel grade Yst -240, having wall thickness as mentioned below & capable of withstanding required test pressure as prescribed in BIS/ISO code, in random lengths of 5.5 to 6.5 mtr. The pipe's ends shall be bevelled suitable for butt welding, including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable ends with up to date ammendments (leak proof) in three layers at site of work with welding rods of standard make & all allied accessories whatever required for welding at site, tail pieces, tees, bends & other specials manufactured from parent pipes as applicable to the particular reach & of approved specification as per site conditions. and cutting of pipes wherever required as per site requirement i/c carriage in all leads & lifts and as directed by Engineer-Incharge. The pipe shall have's zinc coating inside & outside confirming to IS-4736-1986 or latest with up to date ammendments & shall be engraved with Yst-210, code IS-3183-2007 or its equivalent . The laying shall confirm to BIS 5822-1970 or latest with up to date ammendments to the entire satisfaction of Engineer-Incharge (Earth work & cost of MS flanges after 100 meter length shall be measured & paid for seperately).
Stage 1st. API pipe 100mm dia WT 4.80mm
laying jointing and testing of GMS pipe conforming to IS 1239-1991(part-I) of various thickness as mentioned and grade designation with bevelled edge and capable of withstanding required testing pressure in random length of 5.5-65 meters i/c testing and commissioning and cost of jointing with buttwelding as per revant BIS specification ( leak proof) including cost of bends tail pieces, tees reducers increasers etc. as per site requirement and as per directio of the Engineer-in-charge, earth work in trencher to be measured and paid for separately i/c all leads lifts and carriage of materials at site.
Stage 1st. G.I (H) 100 mm dia WT 4.00mm
Providing, welding and fixing M.S. plate flanges of various dia (nominal bore) of following Flange Tables confirming to IS 6392-1971 or latest with up to date ammendments to ERW after 100 mtr. pipe or as per site requirement including cutting of of pipes wherever required, welding in three layers (leak proof) confirming to specifications as prescribed in relvent I.S. Code i.e. IS 816-1969 with electrode as per IS: 814-1991 or latest as applicable with up to date ammendments with nuts, bolts & washers & specials etc. confirming to IS-1963 or latest with up to date ammendments including packing sheet i.e. asbestos fibre sheet minimum 3mm thick and painting with anticorosive paints complete in all respect in all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
100mm Dia. pipe Flenge Table 34
100mm Dia. pipe Flenge Table 38
100mm Dia. Pipes Flenge Table 17
100mm Dia. Pipes Flenge Table 5
Pumping Machinery for 1ST. Stage. Pumping machinery for stage 1st. installation commissioing & testing of horizontal spindle, horzontal/redial split casing/end suction (back full out arrangement) single /double/multi stage centrifugal pump, or combination of pumps. in series/ parrel of recommended make such as Mather and Platt/KSB/Beacon weir/Jyoti (Asea Broven LTD) as per BIS 1520-1980 with uptodate amendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterstics with cromption impeller, proming funnels,casing ring and shaft sleves of bronze shaft of suitable casing coupled directly through a flexible Cast steel/base plate(base plate to be from the manufacture of the pumping unit only) to slipring/squirrel cage screen protected drip proof induction motor/motors of standred make such as Kirloskar/BHELL/Crompton/NGEF/GEC/Siemens/Jyoti of 2900 RPM and suitable for operation on 400(+/-) 5% volts 50 cycles/second 3phase AC electric supply able for operation second 3 phase AC electric supply.The power of electric motor/motors should at least +10% in excess of the maxium power required by the pump/pumps in the operation range of (+)10% and (-)25% of the duty point head.The motor/motors as per IS:325-1978 with up to date ammendments read with IS:900-1972, The strating current of motor shall be limited.It should include cost of painting etc.and should meet the following requirements.
Duty Conditions: i) Discharge (Q) = 6.87 LPS each pump. ii) Total dynamic head 587.14 Mtr. a) LWL in sump well (h) = 1646.50 Mtr. b) Shaft level = 1650 Mtr. c) Level at discharge point = 2175 Mtr. d) Suction lift (+) head 3.00 Mtr. e) Discharge head 587.14 Mtr. f) Static head = 525.00 Mtr. iii) Rising main: =100 mm a) Length of R/main= 3200 Mtr. b) Dia of R/main = 100mm. iv) Pumping hours = 20hours. v) Altitude of installation above MSL 1650 Mtr. vi) Characterstics of water: clear cold water. a) Temperature 35c. b) Ambient temp 0c. c) Turbidity JTU. d) Alkalinity e) Size of the solids NIL mm. f) Others.
Providing ICTP Main switch with HRC fuses of Kilburn/L&T/siemens/Standard/Havells make and having capacity 30% extra of the operational rating as per IS: 4064:1978 with upto date ammendments immeidately after the power meter of the HPSEB. ICTP Switch Make Type Capacity
Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capacable of mounting the following accessories withina ll internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities. Panel Switch Board Drawing Layout plan
MCB/MCCB of MEI/Havels/standard make and of suitable capacity for offered motor incoming feeder with or without initial oil filing as the case may be with neutral linkind under voltage released as per relevent IS code with upto date ammendments. ACB/OCB Make Range Capacity
Earth leakage circuit breaker of recommonded make L&T/MEI/GEC as per IS:2516- 1977 with upto date ammendements and of suitable range which should have control box,operating,handle and trip/reset bush button on/off indicators re-indicating off spring condition of the circuit breaker for over current protection. The cicuit should be equipped with magnet thermal release with matallic tape CST, it should be fitted with earth fault for tripping of breaker on occurance of earth fault on off breaker load side and suitable for above motor and the voltage meter relay 3 phase with all protection and usual indicators and electrid siran against single phasing, low voltage,reverse phasing,over loading and phase voltage difference as per IS:3842(latest edition) ELCB Make Type Range
The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing ,low voltage,high voltage ,reverse phasing ,over loading and phase voltage difference as per IS:3482 (latest edition) Volt meter Make Type Range:
Digital 100 mm diameter circular dial A.C. supply volt meter of recommended make AE/IMP/Havells of suitable range with slector switches as per IS:4064-1978 with uptodate ammendements. Volt meter Make Type Range
Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto uptodate ammendments. Power Factor meter Make Type Range
Digital Frequncey meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto date ammendments. Frequence meter Make Type Range
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for netural phase as per IS:8084-1976 and IS:11353-1985 read with BIS-5578-with uptodate ammendments. Bus bar chamber Make Type Range
Three phase indicator lamps complete with toggie switches for individual motors as per per IS:3452(P_I&II) with up to date ammendements. Three phase indicator Make Capacity
Capacitor of Mecheil/BHEL/GEC/L&Tmake as per IS2834-1986 with up to date ammendements,to raise the power factorat site to 0.95 for direct connection to induction motor individuaily of required KVA rating according to H.P offered including cables as per relevent ISI code(of Siemens/Ciocter/ IEC make0 from busbar chamber to capacitor and also including ICTP switches of appropriate up date ammendements. Capacitor Make Range
P/fixing suitable oil immersed Star Delta strarter L&T/Siemensmake as per IS:8544-1979 with up to date ammendements for squirrel cage/ slip ring motor mounted on panel board with magnetic type over load release and dashpot pot, time lag under voltage release with or with out initial oil filling as the case may be with single phase preventer as per IS:1248(P-V)-1983 with up to date ammendements. Single Type: Make:
Providing Digital hour run meter of recommended make and suitable capacity as per IS :722 (latest edition ) Hour run meter Make Range
Providing antivibration pads under the pumps and motors of suitble size for the above pumping machinery as per IS :6337:1971 Antivibration pads Make Range
Providing of double flanged Cast iron sluice valve of PN1 of Leader/.Bhel Kirlosker/ GIED/ Kilburn/ Fouress make on suction side as per the relevant IS code. Sluice valve Make: Class: Dia:
Providing/Fixing of Cast iron double flanged sluice valve PN1 of Leader/.Bhel Kirlosker/ GIED/ Kilburn/ Fouress make on delivery side as per the relevant IS code. Sluice valve Make: Class: Dia:
P/F double flanged Swing type cast iron valve PN1 of Leader/BHEL/Kirlosker/ Kilburn/GLED/Kartar valve/Fouress make and having bypass arrangements on the delivery side of the pump and capable of with standing the normal sheet pressure as per BIS standas with up to date ammendements Sluice valve Make: Class: Dia:
P/F double flanged Swing type cast steel reflux valve of Leader/BHEL/Kirlosker/ Kilburn/GLED/Kartar valve/Fouress make and of 350 mm dia having bypass arrangements for rising main and capable of with standing the normal sheet pressure as perBIS standas with up to date ammendements Sluice valve Make: Class: Dia:
Provading 100mm dia circular dia analog pressure guage of Fiebig/Bourden/PREGA/Precision make complete with all accessories such as stop cock, copper tubing etc.as per IS :3624-1987 with up to date ammendements. Pressure gauge Make: Digital .
Providing discharge meter of standard make to be fixed on the rising main in pump house as per the direction of the engineer in charge as per IS :2373:1981 with up to date ammendements. Discharge meter Make: Digital .
Installlation of all the items apparing at serial No.1 to 9 as per the systematic drawing
Providing and fixing double flanged MS/GI pipeing work (Layout to be approved by the Engineer -incharge of work for suction and delivery pipe suitable for pump(s) offered and common header as per the R/main respectively complete with all specials such as bends,tees,reducers,increasers with conpanion flanges mating with the relevent spectifications of the accessories as indicated in the drawing no 2 including rubber/asbestos gasket of minium 3mm thickness as per IS:2712-1979 and required no,s of nuts and bolts as per IS1364-1983. the pipe shall be as per relevent IS code and to with stand 1.5 times total head stipulated under item No.1 the size of the various components to be as under:- I)Suction pipe mm dia II)Delivery pipe mm dia III)Common header mm dia and will be extendewd up to 5mtrs from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable (one vable carrying all the three phases) of suitable size and capacity to motors and all other electrical equipments as per IS:1554 (P-I) 1988 or latest with up to date ammend ements of siemens/Gloster/IEC/ICC/ EICO/National/GRANDLY make including all other accessories such as thimbles,flexible pipes, solder,nuts and bolts,vable glands etc. laid in pipes or trenches under floor. Armored power cable Motor side (from switch to starter and starter to motor) Size Make Type Core Supply side(From meter of HPSEB to bus bar Size Make Type Core
ANKUSH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .