Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC | ₹34.4 L | L1 | Accepted-AOC Awarded |
| 2 | L2₹36.2 LRejected-Finance PLOT NO 53 GAYATRI NAGAR DHENKANAL 759001 | DHENKANAL | ODISHA | 759001 | ₹36.2 L | L2 | Rejected-Finance Rate is higher |
| 3 | Rejected-Technical AT BIJAYACHANDRAPUR PO ATHARBANKI VIA PARADEEP DIST JAGATSINGHPUR | JAGATSINGHPUR | JAGATSINGHPUR | ODISHA | - | - | Rejected-Technical Similar Experince Not found |
Tender Value
₹34.4 L
EMD Value
₹34,436
Closing Date
29 Jan 2026, 5:00 pmClosed
EE, LI Division, Dhenkanal
EE, LI Division, Dhenkanal
installation and Energisation of Chaulia-V L.I.P under Dhenkanal Block in Dhenkanal District.
2026_OLIC_124840_1
DKL(OLIC)-04/2025-26
Open Tender
Civil Works - Lift Irrigation Schemes
90 days
Dhenkanal
Please refer Tender documents.
2 documents required · 2 mandatory
₹7,080
₹34,436
Yes
19 Apr 2026
19 Jan 2026
30 Jan 2026
19 Jan 2026
29 Jan 2026
19 Jan 2026
Earth work excavation in foundation in hard soil with 50 mtr initial lead 1.5 m initial lift including rough dressing and breaking clods to 2 cm to 7 cm and laying in layers not exceeding 0.3 m in depth as per direction of Engineer-in-charge
Earth work in hard soil such as hard stiff clay,stiff black cotton, hard red earth, sheles, morrum,.ordinry gravelly within 50 meter initial lead and 1.5mt. Intial lift including rough dressing and breaking the clods and stacking rubble or spreading and levelling within the site as the case may be etc complete as per the direction of the department. Average Rate of Mannual & Machinery (60% mechanical + 40% mannual)
Filling foundation and plinth with sand watered and rammed as per direction of Engineer-in-charge.
Cement concrete (1:4:8) with 4 cm size h.g metal as per direction of engineer-in-charge.
Cement concrete (1:2:4) with 12 cm size h.g Chips as per direction of engineer-in-charge.
Brick work with K.B Brick (25cmx12cm x8 cm) having crushing strength not less than 35kg/cm with dimensional tolerance ± 5% in cement mortar (1:6) in foundation and plinth.
Brick work with K.B Brick (25cmx12cm x8 cm) having crushing strength not less than 35kg/cm with dimensional tolerance ± 5% in cement mortar (1:6) in super structure.
12mm thick cement plaster (1:6 ) over brick masonary
Cement Concrete (1:2:4) with 12 mm size HG chips for R.C.C Works.
Supplying, fitting and placing oncoated HYSD (TISCON) bar reinforcement complete as per drawing and technical specification including cutting, binding, bending and cost of binding wire.
Rigid and smooth centering and shuttering for RCC work including false work and dismentalling them after casting including cost of materials complete.
in foundation ( Plinth Bend )
Lintel
Roof Slab & Chajja
Filling F & P with excavated materials, moorum including watering and ramming as directed by the engineer-in-charge
Filling in F&P with excavated materials by means of Mechanical 60% & mannually 40% i.e. of respective item No. 1 above)
White washing 3 Coat.
Colouring,washing with materials (2 coats)
Priming 1 coat with any appproved Primer including cost of materials
Painting two coats with any approved paints
2.5 cm thick A.S flooring with CC (1:2:4) including punning.
10 cm Thick dray brick Khoa rammed ,well watered.
Cement washing one coat
Supply of M.S Door with door frame grill & Window with cost of priming, painting and fixing etc. In complete shape
Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete as per the direction of the Engineer-incharge.
Cost, Supplying of ISI marked High Density Polythelene (HDPE) Pipes for water supply as per IS 4984/2016 in the following Nominal diameter, Grades of materials, Pressure rating including the rates of ex-factory, transportation, pre & post inspection, Cess etc complete but excluding the cost of GST
160mm Ø HDPE Pipe PE 80- PN 4
200mm Ø HDPE Pipe PE 80-PN 4
Transportation of 160 mm dia HDPE pipe from nearest approved manufacturing units as listed in EPM rate contract to village site of the project
Transportation of 200 mm dia HDPE pipe from nearest approved manufacturing units as listed in EPM rate contract to village site of the project
Supplying all materials, labour, T&P for jointing of 160 mm outer dia High Density Polythylene Pipes of specified material grade & pressure rating by butt fusion welding method as per speciication & laying in tranches including testing including all cost etc complete as per direction of the Engineer-in-charge
Supplying all materials, labour, T&P for jointing of 200 mm outer dia High Density Polythylene Pipes of specified material grade & pressure rating by butt fusion welding method as per speciication & laying in tranches including testing including all cost etc complete as per direction of the Engineer-in-charge
10 HP Monoblock centrifugal pump set at total of 16mtr capable to discharge 1700 LPM squirrel cage induction motor fitted with companion flanges and class -F insulation suitable for operation 415 volt+6%-15%, 3phase, 50Hz AC power supply and full load current 15.6 amp with size of suction and delivery 100mmx100mm dia with overall efficiency 60 -65. The materials of construction as given below. a) Casing :F.C. 200 as per IS 210/1978 b) Impeller : Bronze grade LTB-2 of IS c) Shaft : High carbon steel grade 40c8 of IS 1570(Part-2)318/1981 d) GAsket : As per IS 5120/1977 and the pump sets must be as per IS-9079/2002 of reputed brand having wide dealership net work for easy availability of spares.
Supplying fitting fixing control pannel starter, BCH make with arrangement of volt meter, Amp, Meter mfitted with MCB control switch complete including indicator lamp with irrigation pannel bozard of apaproved design made out of 16gauge CR sheedt basement MS angle with double lock powder coat painting over one coat primere including fixing danager board with lucking devices and fixing of suitable stand for control pannel unit.
4 KVR Capacitor
Motor hood cover of 18 gauge C.R. sheet with double coat painting over one coat primer so as to cover the motor
MS base plate for fitting of pannel and pump as per sample as per direction of Engineer-in-charge.
3 x 16 sqm Tarpodar Cable XLPE (Cross like polythylin) confirming to IS-7098 (Part-II) including laying below 9 mtr of the ground & fitting the excavated materials including watering & ramming.
63/100 AMP 415 volt T.P. main switch confirming to IS 4064 (Pt-I & Pt-II) with utilisation category Ac-22.
Supply, fittintg and placing of 100mmdia Nominal Bore GI pipes having wall thickness 4.5 mm electrical resistance welded of medimum class confirming to IS-1239 (part-I/2004) with latest amendments, screwed at both ends as per IS-554 socketed at 1 end and other end protected with plastic threaded protector. The socket confirming IS-1239 (Part-II/1992) with latest amendments in rendom length of 4 to 7 mtrs. Each pipe should bear ISI certification and manufacturers name /trade mark.
Labour charges for fitting, fixing of suction, delivery fitting including M.S. Tee set, NR valve, Switch valve and Air release valve etc minor welding transportation of materials to site etc. including nut, bolt rubber insallation etc complete.
Fabrication of special joint including cutting and welding of pipes out of M.S Pipe / G.I Pipe including welding of flange at one end and other end suitable for for connection to delivery pipe lines of pump sets including cost of cutting and welding , materials and fitting it in proper alignment with the delivery pipe line of pump set etc. complete.
Cost of pump chamber wiring
100mm dia C.I. Screw base foot valve (Kirloskar make ) IS
100mm dia G.I. bend IS No 1239 (Part-II/1992)
100mm dia G.I. flange IS No 6392/1971
100mm dia G.I. Socket IS No 6392/1972
100 mm dia C.I. N.R valve IS No 5312 (Part-I) with ISI mark
100x100x25mm dia G.I. Tee with Plug for Priming set
Cost of 200 mm dia Blind Flange
Cost of 160 mm dia Blind Flange
Cost of Nut Bolt.
Cost of Rubber Insuration.
160x160x110mm MS Tee set with bend,closing and opening arrangement
Cost of Butter fly valve
50mm dia C.I. Air Release Valve IS Mark 14845(SI)with 1 mtr long G.I.Short piece with saddle
Cost of 200X200X160 mm Spigot moulded reducing HDPE Tee 10 kg
200mm x110 mm HDPE reducing socket
Construction & erection of 11 / 0.416 KV ,25 KVA/ 63 KVA, (3 star rated transformer) D.P. Substation confirming to RE Rules 1956, mounted on 2.44 Mtr long structure, supported in 330 Kg 10 Mtr long PSC pole, transformer hard channel & top channel made of 2.80 M long 100x50x60 mm M.S. Channel, Transformer belting on 2.80 Mtr long 50x50x50 mm M.S. Angle, (all REC SPN. Std. F-3) with all accessories like 3 pole 11 KV HG Fuse (F-5) & A.B. Switches (F-9) both mounted on 2.80 M long 75x40x60 mm M.S. Channel and supported by 1.0M long 50x50x50 mm M.S. Angle, with 3 No. 11 KV Lightening Arrestors & Distribution box for 25/63 KVA S/S, Pipe earthing (F-2) , including cost of 50 Sqm 3.5 Core PVC Cable carpping & padding of Poles, Danger board at each Pole, Anti Climbing Devices & all other necessary fittings i.e. required size Nuts & Bolts, Brackets, Cable, Cable Sockets etc. including cost of all materials, labour, transportation complete with liasioning for testing inspection & commissioning etc as per CESU specification.
25KVA Sub Station
Construction of 3 phase 11 KV line as per REC standard confirming to RE Rules 1956 with 330 Kg 10 Mtr long PSC Pole support in 40 M span, 55 Sqmm XLPE covered Conductor, 11 KV "V" Cross arm , with required No.of 11 KV T & C Disc.Insulators & 11 KV Pin Insulators, Carping & Padding of Poles, Danger Board at each Pole, Anti Climbing Devices, Stay Set at Bending point & Double Stay at end point with 18 mm G.I. H.T Stay , concreting of Stay with Anchor plate, guarding at Road crossings etc.including cost of all materials, labour, transpotation, inspection & commissioning etc. complete.
Interposing pole on 11 kv line.
11 KV Line 90 degree cut point
11 KV Line 180 degree cut point
Electrical Earthing with 40mtr dia medium duty GI earthing pipe each 3 m longwith installation including cost of all materials like GI flange chorcoat, salf etc. as required as per I.E Rule
Other Electrical materials such as pvc tape.7/20pvc copper wire 3/20 pvc copper wire G.I flxible condite pipe no 6 GI wire copper cable socket GI socket and petty materials required for electrical installation. All materials should be as per IS including fitting charges and electrical installation & energisation.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_576832.pdf
techsummary_576832.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
Tendernotice_2.pdf
PDF • 1.10 MB
BOQ_576832.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid