| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69.0 LAccepted-AOC HOUSE NO 413 MAGADH COLONY SHERGHATI ROAD GAYA BIHAR PIN 823001 | GAYA | BIHAR | 823001 | L1 | Accepted-AOC MS Chauhan Construction is lowest and accepted | |
| 2 | L2₹76.7 L+₹4.4 L (6.04%)Rejected-Finance | L2 | Rejected-Finance Not Qualified | |
| 3 | L3₹87.8 L+₹15.4 L (21.3%)Rejected-Finance SHIV BHAWAN MAGADH COLONY ROAD NO 03 SHERGHATI ROAD GAYA BIHAR PIN 823001 | GAYA | GAYA | BIHAR | 823001 | L3 | Rejected-Finance Not Qualified | |
| 4 | L4₹88.5 L+₹16.1 L (22.3%)Rejected-Finance | L4 | Rejected-Finance Not Qualified | |
| 5 | L5₹1.2 Cr+₹43.7 L (60.4%)Rejected-Finance | L5 | Rejected-Finance Not Qualified |
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
14 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Y K Gour
HQ CWE Ranchi , MES, Dipatoli Cantt
ADDN AND ALTN CUM SPL REPAIR TO CERTAIN OTM ACCN OF MH GAYA
2023_MES_584933_1
80599/1468/E8
Open Tender
Civil Works - Others
Item Rate
180 days
GE Gaya
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE Gaya
₹1.8 L
Yes
HQ CWE Ranchi
19 May 2023
10 Mar 2023
21 Apr 2023
10 Mar 2023
14 Apr 2023
31 Mar 2023
10 Mar 2023 - 17 Mar 2023
17 Mar 2023
Amount
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as directed
M & L for providing PCC type B0, 1 : 2 : 4, (using 12.5 mm graded stone aggregate) as in coping, and the like including weathering, slightly rounded or chamfered angles and throating complete with using WPC mixed with cement concrete as per manufacturer's instruction complete all as directed( WPC shall be measured and paid seperately)
Taking down cement plaster on brick or stone walls etc, including racking out joints, hacking for key, scrubbing down with water etc.complete all as directed
M & L for rendering 15mm thick on internal surfaces on brick work in cm 1:6 in and finishing surfaces even and fair without using extra cement complete all as directed.
M & L for rendering 15mm thick in two layers on external surfaces on brick/concrete in CM 1:4 finished even and smooth without using extra cement with WPC mixed with cement concrete as per manufacturer's instruction complete all as directed( WPC shall be measured and paid seperately)
Supply only liquid water proofing compound ISI marked complete all as directed.
M & L for 2 mm thick wall care putty in two coats on new/old plastered surfaces and making the surface uniform & smooth on walls/ceilings complete all as directed.
M & L for preparation of old plastered surfaces and applying one coat of acrylic distemper on walls complete all as directed.
M & L for preparation of new plastered surfaces and applying two coat of acrylic distemper on walls complete all as directed.
M & L for two coat of cement base paint white or tinted on walls or fascia of roof or chajjas on new or old decorated prepared plastered/painted surfaces complete all as directed.
M & L for one coat of cement base paint white or tinted on walls or fascia of roof or chajjas on old decorated prepared plastered/painted surfaces of wall complete all as directed.
Dismantling floor, hearth or wall tilling including cement mortar bedding , removing serviceable tiles from site and rubbish off the premises complete all as directed.
M & L for vitrified coloured tiles 10mm thick (square/ rectangular) light shade,first or premium quality , area of each tiles not less than 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed in CM 1:4 complete all as directed.
M & L for coloured Glazed ceramic tiles in vertical surface 450x300x 7mm thick,,first or premium quality , set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick screed in CM 1:4 complete all as directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as directed.
M & Lfor brick work using fly ash Brick straight or curved on plan to any radius of half brick thick built in cement mortar 1:4 complete all as directed.
M & L for brick work using fly ash Brick straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as directed.
S & F of Vitreous China wash down water closet pan (pedestal pattern), white including fixing bolts, but excuding flushing cistern and flush pipe complete all as directed.
S & F of 10 litre PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe complete all as directed. .
S & F as in repair of white soft closing seat cover for pedestal pattern water closet including fixing bolts complete all as directed.
S&F in repair brass chromium plated health faucet 15 mm with flexible tube (1.5 m long) of stainless steel provided rubber hose and wall hook etc complete all as directed.
S&F in repair 15 mm dia bore bib taps, brass chromium plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as directed. .
S&F in repair 15 mm dia two way bib taps, brass fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as directed. .
S&F in repair 15 mm dia stop/angle valves, cast copper alloy, CP fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete all as directed. .
S & F in repairs CPVC pipes 25 mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including necessary cutting/chasing of walls and floors complete all as directed. .
S & F of Male Brass Threaded Adaptor (MTA/ MBTA) or Female Brass Threaded Adaptor (FTA/ FBTA) complete all as directed.
S & F of PVC connections 15mm size with PTMT nuts of length 600mm complete all as directed.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors and connecting with manholes or disposal place complete all as directed. .
S & F 110mm bore PVC (SWR) bends with access door complete all as directed.
S & F 110mm bore PVC (SWR) vent cowl with rubber ring joints, fixed to pipes complete all as directed.
S & F of PVC (SWR) junction single, (Single T) 110 mm bore equal or unequal with acess door complete all as directed.
M & L for plain cement concrete type D-2 (1:4:8) using 40mm graded stone aggregate as in surface channel & drains complete all as directed.
S & F Powder coated (average thickness of powder coating 50 micron) aluminium frame/shutters for windows, ventilators sliding/openable etc icluding joining cleat for fixing, locking arrangement, rubber beading, screws, etc complete all as directed. Note : (i) Glazing and wire mesh shall be measured and paid separetely only as the labour element included in the relavent item. (ii) Item shall be paid as per weight of aluminium section (iii) The rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as locking arraangement etc as required, which shall not be measured for arriving the weight (iv) The rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing.
S&F in Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.18mm and fixed with beeding/Staples complete all as directed.
S & F of 4.00 mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as directed.
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares of any size n. exc 0.50 Sqm each complete all as directed.
M & L for prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as directed.
M & L two coats of synthetic enamel painting on steel surfaces exc 10 cm width or girth over one coat of red oxide primer including preparation of new steel surfaces complete all as directed.
M & L two coats of synthetic enamel painting on wooden surfaces exc 10 cm width or girth over one coat of pink primer including preparation of wooden surfaces complete all as directed.
S & F as in repair aluminum alloy, anodised, cast type or extruded section, sliding door bolt with hasp & staple (bolt type) with fixing clips of sheet and bolts 300 mm long complete all as directed.
Taking down chowkhats or frames not exc 1.5 Sqm ( without taking shutters from the frame) complete all as directed. .
M&L for TMT bars 10mm dia and over cut to lengh bent to shape required incl cranking bending spirally for hooping for columns hooking ends and binding with and incl mild steel wire not less than 0.9mm dia complete all as directed.
All as per item No 43 here in before but 6mm dia and over in stirrups, spacers and binders complete all as directed.
M & L for RCC Type B-1, 1:2:4 using 20 mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as directed. .
Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as directed.
Dismanteling ceiling and wall boards of any type or any thickness inclluding cover fillets complete all as directed.
M& L for providing aluminium snap Grid frame work for false ceiling of size 600x600 mm using Main and cross tee of size 36.5mmx25mmX1.4mm weighing 0.24kg /RM and 23.5mm x 26.4mmx1.4mm weighing 0.19kg/RM respectively, the snap grid shall be supported at end all along the wall with aluminium anodised angle of size 40mmx25mmx2mm weighing 0.36Kg/RM. The snap grid shall be fixed to ceiling supporting hangers consisting of 4mm dia MS wire/GI wire, J bolts nuts and washers from purlin of the roof as per manufacturer's instructions, complete all as directed.
S & F of 4 mm thick non asbests fibre cement board manufactured using HPSC (High Pressure steam cured) technology pre-primed textured designer board, water resistant, be placed in the grid system fixed with steel dash through fasteners complete all as directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as directed.
Dismantling of asbestos cement corrugated sheets as in roof coverings complete all as directed.
M & L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing including distance pieces, cleats etc Fe 410 W (Gde E - 250 quality) complete all as directed.
M & L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, framed guard bars; barred iron doors and similar work conforming to Fe.290.Gde-E-165 complete all as directed.
M & L for Mild steel screw bolts (machine made) with hexagonal heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal nut, exc 5cm but n exc 10cm long dia of neck is exc 11 mm but n.exc 15 mm complete all as directed.
M & L for Mild steel bolts purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long dia of neck is exc 12 mm but n.exc 20 mm complete all as directed.
M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as directed
M&L for Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in redge, fixed with self tapping screws complete all as directed .
M&L for Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with Grey cement and no pigment including 15mm thick screed bed in CM(1:6) complete all as directed.
M & L for 16- 18 mm Granite slab (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like including 15 mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as directed. .
S& F Vitreous Cliina wash basin, wliile, flat back, size 580x450 mm (for Hospilal use) excluding taps, waste, chain and plug and porcelain stopper but including brackets to fix basin, waste pipe and CP waste coupling 32 mm dia complete all as directed.
Supply & fix in repair brass chromium plated pillar tap swan neck long body fancy type for wash hand basin for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as directed.
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit and making good distrubed surfaces of walls, floors etc complete all as directed
Taking down old/ unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as directed
Taking down carefully copper/aluminium Sub main wiring of any size from surface/ concealed/ existing conduit of any height and making good disturbed surfaces of walls, floors roofs etc complete all as directed.
Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M Gaya ccomplete all as directed.
M&L for point wiring with 1.5 Sq mm single core PVC insulated unsheathed copper FRLSH multi stranded conductor cable in and including Concealed PVC conduit of size 20/ 25 mm ISI marked inclusive of tees ,bend ,elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc with white laminated 3 mm thick hylam sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sq mm FRLSH cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as directed for following :-
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
Description all as per item No 66 here in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLSH, PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor FRLSH, PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
S & F for Switch Piano type single pole 5 amp, 230 Volts complete all as directed
S & F for Switch Piano type single pole 15 amp, 230 Volts complete all as directed.
S & F for socket outlet 2 in 1 , 5 pin, 5 amp, 230 Volts complete all as directed
S & F for socket outlet 2 in 1 , 5 pin, 5/15 amp, 230 Volts complete all as directed
S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as directed
S & F for stepped type electronic fan regulator flushType complete all as directed
S & F for lamp holder , PVC / Polycarbonate type with back plate suitable for batten/ slanting fittings complete all as directed
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc including one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm earth cable and one run of PVC conduit will be measured as one unit
S & F for replacement of sheet metal enclosure MCCB DBc TPN 4 way with 200 Amps rated bus bar double door suitable for 01 No incoming MCCB of 160 Amp capacity and 12 Nos + 12 Nos outgoing MCB SP complete all as directed Note: MCCB & MCBs are measured and paid separately under respective items of same make.
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as directed
S & F for MCB single pole and neutral rated capacity 40-63 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as directed.
S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as directed
S & F in replacement of MCCB 4 pole, 160 Amps with breaking capacity 16 KA, 415 volts complete all as directed.
S & F for ceiling fan, 230 volts, 1200 mm sweep with service value of the fan shall be greater than 6.1 as per BIS with necessary accessories and electrical connections from ceilig rose to fan terminal complete all as directed
Labour only for refixing the celing fan/ Exhaust fan obtained from item No 65 here in before with replacement of unservicable PVC insulated PVC sheated 3 core multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal including over hauling the fan, painting of ceiling fans complete with two coats synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc. complete all as directed
S & F for Highly efficient LED Bulbs, 10 W, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap of make Bajaj, Havells, HPL complete all as directed
S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as directed. Make :- Make Bajaj Cat part No BCLAB 20W WH LED P, Wipro Cat part No LL20-281-XXX065-ALI or its equvalent in Philips, Havells.
S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed. Make :- Bajaj Cat part No ENXT P 24L WH CR PC SD (Edge plus series) or its equvalent in Philips, Wipro, crompton.
S & F for energy efficient exhaust fan of 300 mm sweep made of metal body complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base complete all as directed (Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted).Make:Havells cat No Ventil Air -DS or equivalent in crompton/Bajaj/Philips
Taking down existing old unserviceable LT UG/ service cable of any description and size complete all as directed
(Supply, laying, testing and commisioning LT underground cable 1100 volts grade, XLPE insulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trenches/ducts, on poles etc of size 4 core x 25 Sqmm complete all as directed
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground.(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr. Below ground level connecting to galvanised earth lead wire 4mm dia by means of bolts, check nuts and washers of GI and earth wire protected by provision of GI pipe light grade, 15 mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded crushed stoned aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25 x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, test pont made out of phosphorous bronze with fixing arrangement, funnel, wiremesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection all as directed and testing on completion.
Excavation in trenches not exceeding 1.5 mtrs wide & not exceeding 1.5 mtr in depth in soft or loose soil & getting out complete all as directed
Returning filling including spreading levelling watering & well Ramming in layers not Exc 25 cm complete all as directed
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed.
Supply and laying in trenches dry well burnt old size sub class “B” bricks designation 75 over sand cushioning for protection of cable complete all as directed.
Material and labour for river sand cushioning for under ground cable with locally available sand for protection of cable including spreading and consolidations, complete all as directed.
DHEERAJ KRISHNA CONSTRUCTION PVT LTD
M/S ABHAY KUMAR AND BROTHERS
M/S SANJAY KUMAR YADAV
B.K.ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .