Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹14.1 L+₹3,430 (0.24%)Rejected-Finance | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 3 | L3₹14.1 L+₹7,335 (0.52%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 4 | L4₹14.3 L+₹21,527 (1.53%)Rejected-Finance | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹32,000
Closing Date
3 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
8599REPAIR AND MAINT OF COOLING AND HEATING APPLIANCES WITH CONNECTED ITEMS IN EAST AREA UNDER GE M AF JALAHALLI
2021_MES_479900_1
8599/E8
Open Tender
Electrical and Maintenance Works
Item Rate
242 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF MAINT PUBLIC FUND ACCOUNT
₹32,000
7 Dec 2021
6 Oct 2021
5 Nov 2021
6 Oct 2021
3 Nov 2021
21 Oct 2021
6 Oct 2021 - 13 Oct 2021
60 days
Amount
Material and labour for servicing/cleaning of complete indoor and out door unit of Ducted Split type / Split Type Air conditioner for Ducted Split type AC 8.3 TR Capacity capacity by means of adding cleaning solution with water. The cleaning of the condensor and chiller tubes shall be done with use of nylon brushes till the scaling is removed and ensuring its serviceability by rectification / replacement of unserviceable parts and keeping AC in good working condition all as specified and as directed by Engineer-in-Charge for Ducted Split type AC 8.3 TR Capacity. Note :- Supply of spares for replacement will be measured and paid separately under relevant item of Sch 'A'.
All as per item No 1 but for Ducted Split Type AC 4.0 TR
All as per item No 1 but for Split Type AC 2.0 TR
All as per item No 1 but for Split Type AC 1.5 TR
Material and labour for servicing / cleaning of Water cooler of any capacity , make and model complete by cleaning the outer unit by means adding cleaning solution with water. The cleaning of condensor and chiller tubes is done with use of nylon brushes till the scaling is removed and inner tank should be cleaned using bleaching powder and keeping the inner tank clean from bacterial and descaling and ensuring its serviceability all as specified and as directed by Engineer-in-Charge. Note :- Supply of spares for replacement will be measured and paid separately under relevant item of Sch 'A'.
All as per item No 5 but for Refrigerator of any capacity, make and model
All as per item No 5 but for Deep freezer of any capacity, make and model
Attending complaints as per Job card issued by the department for Ducted Split type AC 8.3 TR Capacity repair / troubleshooting complete including replacement of unserviceable fasteners etc, identification of defective components including replacing, to make unit functional :- Note :- Supply of spares for replacement will be measured and paid separately under relevant item of Sch 'A'.
All as per item No 8 but for Ducted Split Type AC 4.0 TR of any make and model
All as per item No 8 but for Split Type AC 2.0 TR of any make and model
All as per item No 8 but for Split Type AC 1.5 TR of any make and model
All as per item No 8 but for Water Cooler of any capacity make and model
All as per item No 8 but for Refrigerator of any capacity make and model
All as per item No 8 but for Deep freezer of any capacity make and model
All as per item No 8 but for Voltage stabiliser of capacity 1 to 5 KVA.
Taking out unserviceable compressor of Split Type AC 1.5 Ton capacityfrom site and replacrement of new compressdor against repair of existing make, the compressor sealed unit in position, charging of refrigerant gas suitable type of required quantity, bracing of discharge and suction line and leak testing complete as directed by the Engineer-in-charge.
All as per item No 16 but for Split Type AC 2 Ton capacity of any make and model
All as per item No 16 but for Ducted Split Type AC 4 Ton capacity
All as per item No 16 but for Ducted Split Type AC 8.3 Ton capacity of any make and model
All as per item No 16 but for Water cooler of any make and capacity
All as per item No 16 but for Refrigerator of any make and capacity
All as per item No 16 but for Deep freezer of any make and capacity.
Pressure testing / leak arresting , vaccumising with dry nitrogen gas / oil charging, incl replacing the unserviceable strainers and capillary tubes all as required testing complete for Ducted Split Type AC 8.3 TR including transportation to workshop:-
All as per item No 23 but for Ducted Split Type AC 4.0 TR
All as per item No 23 but for Air conditioner Split type 1.5 / 2 TR capacity.
All as per item No 23 but for Water cooler of any make and capacity
All as per item No 23 but for Refrigerator of any make and capacity
All as per item No 23 but for Deep Freezer of any make and capacity
Gas charging with R-134a for Refrigerator and Water coolers in position including leak testing to achieve desired suction pressure and temperature (or any other cooling applainces also)
Gas charging with R-22a for split type AC in position including leak testing to achieve desired suction pressure and temperature (or any other cooling applainces also)
Supply only Condenser blower motor for Outdoor Split type type AC 1.5 / 2 TR capacity.
Supply only Condenser blower motor of water cooler / deep freezer of any capacity, make and model
Supply only Blower motor of indoor unit of split AC 1.5/2TR
Supply only Fan Blade suitable for 1.5 / 2 Ton Split Type Air conditioner
Supply only Fan Blade suitable for Water Cooler of any capacity / Make
Supply only thermostat for water cooler / refrigerator / deep freezer / ACs of any capacity and make.
Supply only relay for any type of AC / water cooler /refrigerator/deep freezer of any capacity & make.
Supply only OLP for any type of A/C/water cooler /refrigerator/deep freezer of any capacity & make.
Supply only PCB suitable for split /window type A/C 2/1.5 TR of any make.
Supply only wiring kit suitable for split type A/C 2/1.5 TR of any make.
Supply only wiring kit suitable for water cooler/refrigerator/deepfreezer of any capacity and make.
Supply only starting capacitor 80/ 100 mfd for airconditioner .
Supply only starting capacitor 120 mfd for airconditioner .
Supply only Running capacitor 45 mfd for Split type Air conditioner 1.5 Ton Capacity
Supply only Running Capacitor capacitor 60 mfd for Air conditioner 2 Ton Capacity
Supply only Running capacitor 36 mfd for air conditioner of any capacity & water cooler of any capacity
Supply only auto swing motor for inside unit of split A/C of capacity 2/1.5 TR of any make
Supply only remote control system of split / window type A/C of capacity 2/1.5 TR .
Supply only PVC air filter for split type A/C of any capacity & make .
Supply only contactor suitable for 2/1.5 TR of any make
Supply only contactor suitable for 4 /8.3 TR of any make
Supply only Brass angle valve 5/8 inch for split AC 1.5/2TR capacity.
Supply only Brass angle valve 3/8 inch for split AC 1.5/2TR capacity.
Supply only Copper tubing 5/8" dia for extending refrigerant piping including brazing/adopter and accessories.
Supply only Copper tubing 3/8" dia for extending refrigerant piping including brazing/adopter and accessories.
Supply only Puff insulation to suction pipe of split AC.
Supply only Bi-metal for refrigerator
Supply only timer for refrigerator
Supply only PVC ball valves,float valve for water cooler of any capacity & make
Supply only brass chromium plated push button tap outer/Inner thread suitable for water cooler of any type of size 15 mm .
Supply only PCB suitable for capacity upto 5 KVA Voltage stabiliser
Supply only Transformer Suitable for up to capacity 5 KVA Voltage stabiliser
Supply only door lock for refrigerator/Deep freezer any capacity
Supply only baffle tray for refrigerator any capacity
Supply only crisper tray for refrigerator any capacity
Supply only condensor coil for 1.5 Ton Split AC
Supply only condensor coil for 2.0 Ton Split AC
Supply only condensor coil for refrigerator of any capacity
Supply only Evaporator coil for refrigerator of any capacity
Supply only indoor unit for 1.5 Ton Split AC
Supply only indoor unit for 2.0 Ton Split AC
Supply only add on block suitable for 4/8.3 Ton split AC
Supply only timer ET 500 suitable for 4/8.3 Ton split AC
S&F copper cable flexible 3 core of size 2.5 sq mm .rubber insulated
Supply and fix plug top 15 Amp,3 pin conforming to revent IS
Supply and fix plug top 5 Amp,3 pin conforming to revent IS
Taking down the existing window type AC from the wall and Material and labour for closing the existing opening after removing window type AC by closing of opened wall with neccesary brick masonary and plastering including matching with the existing surface all as directed.
Attending complaints / servicing including trouble shooting /repair of geyser 25 to 50Ltrs capacity checking of serviceability of individual parts such as thermostat, heating element, pressure release valve, inlet/outlet connections etc, replacing worn-out fasteners and defective components and testing including taking down the geysers and refixing the same after repairs. Note : Spare parts including replacement will be measured and paid separately under relevant item. Rate quoted shall include replacement of worn-out fasteners.
Supply only 1.5 KW any type of heater coil of geyser all as per existing make / model / size conforming to relevant IS.
All as per item No 79 but for 2 KW any type
Supply only thermostat for any type /make/capacity of geyser .
Supply only pressure release valve 15mm dia with new one for any type /make/capacity of geyser .
Supply only PVC flexible connection of 15 mm dia 600 mm long with check with new one suitable for cold/hot water connection of geysers
Supply and Fix stop valves, fancy type chromioum plated,cast copper alloy screwed down high pressure with crutch or butterfly handle, screwed both ends with iron pipes of 15mm bore including taking down existing unserviceable stop valves
Supply and Fix 20 mm Non return valves, cast copper alloy, for GI Pipes pipe all as directed
Taking the copper or steel container carefully from the geyser, descaling, rectifying leakage by braising, resetting the insulating (glass wool), testing for the required pressure replacing rubber gaskets, worn-out fasteners etc,. with new ones complete all as directed by Engineer in charge.
Supply and Fix Base plate of Water Heater of 25 / 50 Ltrs Capacity all as directed
Supply only Indicator Lamp of RED / GREEN Suitable for Water Heater
S&F in replacement of Single pole and neutral Sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amps, 240 Volts, AC,50 HZ, completete all as directed and specified, including taking down old unserviceable plug socket and offering for credit.
Supply and fix PVC insulated copper cable flexible 2.5 sqmm 3 core
S&F copper cable flexible 3 core of size 4 sq mm .rubber insulated
Removing & Taking down solar water heater of any type & make after disconnecting the electric and water connections plugging the inlet and outlet as required at the building , repairing the solar water heater by removing unservicable parts such as , thermostat,heating element, pressure release valves, rubber gaskets,inlet/outlet connections ,testing for the required pressure, refixing the same in position with nuts and washers complete all as directed by engineer in charge.
Supply and Fix heating element 3 KW, 230V for solar water heater for 200 LPD capacity
Supply and Fix Toughened glass 1010 x 2020 x 5 mm including taking down old / broken toughned glass carefully bydisconnecting all connects, complete all as directed.
Cleaning of storage tank of solar water heaters of any capacity in position with liquid soap solution, flushing with fresh potable water, sweeping with clean dry cloth and resetting of float valve to maintain the correct level of water in the tank and writting the date of tank cleaning clearly in white letters all as specified by Engineer in charge.
Supply and fixing rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP 5 To 32 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning.
Supply and Fix Solar collector panel of any capacity of solar water heater
Supply only Annode Rods for any capacity of solar water heater
Supply only rubber pipe for any capacity of solar water heater
Supply only copper washer for any capacity of solar waterheater
Supply and lay pipes galvanised GI Tubing medium grade 20 mm bore fixed to walls and ceiling or laid in floors in old or new position including fitting like socket / union / Tee / Reducer Nipple etc complete all as directed
Supplying and laying of CPVC pipes 20 mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified
PLATINUM CONSTRUCTIONS
ANAND REFRIGERATION
M.G. Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .