Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53.2 LAdmitted-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | L1 | Admitted-Finance | |
| 2 | L2₹54.6 L+₹1.4 L (2.63%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹61.4 L+₹8.2 L (15.4%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | AJAY KAPOOR L2 | vijay builders L1 | T AND D CONSTRUCTIONS AND TRADING COMPANY L3 |
|---|---|---|---|---|---|---|
| 1.00Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV line on 9 mtr long PCC poles for creation of 100 KVA Sub Station at Village Sui. | ||||||
| 1.01 | 9 mtr. Long PCC Pole (PCC WL-300Kg)) | 19 | no. | 76,000 ₹3,61,000 | 57,000 ₹1,90,000 Lowest | 76,000 ₹4,56,000 |
| 1.02 | GI V Cross -arm with top Bracket including clamps | 260 | Kg | 5,200 ₹33,800 Lowest | 10,400 ₹46,800 | 5,200 ₹33,800 Lowest |
| 1.03 | GI Channel X-arm including clamps and Angle for braces | 144 | Kg | 2,880 ₹18,720 Lowest | 5,760 ₹25,920 | 2,880 ₹18,720 Lowest |
| 1.04 | 0.03 ACSR Weasel conductor | 2.75 | Km | 8,250 ₹90,750 Lowest | 22,000 ₹1,04,500 | 8,250 ₹90,750 Lowest |
| 1.05 | 11KV Pin Insulator (Polymeric) with Pins (12kv, 5KN) Creepage Distance 320mm | 51 | no. | 1,020 ₹13,770 Lowest | 2,550 ₹15,300 | 1,020 ₹13,770 Lowest |
| 1.06 | 11KV Disc Insulators (Polymeric 45KN ) creepage distance 320 mm with tension fittings | 12 | no. | 240 ₹3,840 Lowest | 600 ₹4,800 | 240 ₹3,840 Lowest |
| 1.07 | Galvanized Nuts and Bolts | 19 | Kg | 380 ₹2,470 Lowest | 950 ₹3,800 | 380 ₹2,470 Lowest |
| 1.08 | Danger Plates with Clamps | 19 | no. | 380 ₹4,180 | 950 ₹3,800 Lowest | 380 ₹4,180 |
| 1.09 | Anti- Climbing Device with Clamps | 19 | no. | 950 ₹2,850 Lowest | 950 ₹7,600 | 950 ₹2,850 Lowest |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
23 Dec 2021, 4:00 pmClosed
Executive Engineer
Electric Division JPDCL Udhampur
Creation of substation along with HT and LT Line
2021_PDD_151021_1
ED/UDH/58 of 2021-22 dt. 01-12-2021
Open Tender
Electrical Works
Turn-key
180 days
Village Sui, Jadsarkote, Maden, Tikri and Round-II
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Executive Engineer Electric Division JPDCL
₹1.1 L
7 Feb 2022
2 Dec 2021
27 Dec 2021
2 Dec 2021
23 Dec 2021
2 Dec 2021
2 Dec 2021 - 9 Dec 2021
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV line on 9 mtr long PCC poles for creation of 100 KVA Sub Station at Village Sui.
9 mtr. Long PCC Pole (PCC WL-300Kg))
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
0.03 ACSR Weasel conductor
11KV Pin Insulator (Polymeric) with Pins (12kv, 5KN) Creepage Distance 320mm
11KV Disc Insulators (Polymeric 45KN ) creepage distance 320 mm with tension fittings
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti- Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm for LT
Stone Pad (300 mm X 300 mm X 73mm)
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for creation of 100 KVA Sub Station at village Sui.
11/0.433kV, 3-phase 100 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
120 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type
9 mtr. Long ST Pole (ST-410 SP33)
11kV Polymeric composite Disc Insulator 12kV, min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with tension fitting
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution box for 100 KVA DTR with MCCB for incomer and SFU's for outgoing circuits.
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Cement bottoming of ST poles in 1:2:4 mix as per REC standards
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 50 mm x 6 mm & 32mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Painting of sub station ST poles/cross arms/clamps with one coat of Red oxide and two coats of aluminium paint
Danger Plates with Clamps
Anti-Climbing Device with Clamps
3-Ø, 4 wire LT Prodigy meter
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of LT line 1 phase 2 wire on 8 mtr long PCC poles at village Sui.
8 mtr. Long PCC Pole (PCC WL-200Kg))
GI U-Clamp for shackle insulator
0.03 ACSR Conductor Weasel.
Shackle Insulators
Galvinized Nuts and Bolts.
Danger Plates with Clamps
Anti- Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm for LT
Stone Pad (300 mm X 300 mm X 73mm)
LT line spacers
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete.
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of LT line 3 phase 4 wire on 8 mtr long PCC poles at village Sui.
8 mtr. Long PCC Pole (PCC WL-200Kg)
GI U-Clamp for shackle insulator
0.03 ACSR Conductor Weasel.
Shackle Insulators
Galvinized Nuts and Bolts.
Danger Plates with Clamps
Anti- Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm for LT
Stone Pad (300 mm X 300 mm X 73mm)
LT line spacers
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV line on 9 mtr long ST poles for creation of 63 KVA Sub Station at Jadsarkote Madeen Block Tikri.
9 mtr. Long ST Pole (ST-410 SP33)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
0.03 ACSR Weasel conductor
11KV Pin Insulator (Polymeric) with Pins (12kv, 5KN) Creepage Distance 320mm
11KV Disc Insulators (Polymeric 45KN ) creepage distance 320 mm with tension fittings
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti- Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm
Painting of 9 mtr ST poles including crossarms/clamps with one coat of Red oxide Paint.
Painting of 9 mtr ST poles including crossarms/clamps with two coat of Aluminium Paint.
Cement bottoming of ST poles in 1:2:4 mix as per REC standards
Galvanised Stay Set with 50x8mm Stay clamp, Guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for creation of 63 KVA Sub Station at Jadsarkote Madeen Block Tikri.
11/0.433kV, 3-phase 63 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
120 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type
9 mtr. Long ST Pole (ST-410 SP33)
11kV Polymeric composite Disc Insulator 12kV, min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with tension fitting
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution box for 63 KVA DTR with MCCB for incomer and SFU's for outgoing circuits.
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Cement bottoming of ST poles in 1:2:4 mix as per REC standards
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 50 mm x 6 mm & 32mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Painting of sub station ST poles/cross arms/clamps with one coat of Red oxide and two coats of aluminium paint
Danger Plates with Clamps
Anti-Climbing Devices with Clamps
3-Ø, 4 wire LT prodigy meter
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of LT line 1 phase 2 wire on 8 mtr long ST poles at Jadsarkote Madeen Block Tikri.
8 mtr. Long ST Pole (ST-410 SP15)
GI M-Clamp for shackle insulator
0.03 ACSR Conductor Weasel.
Shackle Insulators
Galvinized Nuts and Bolts.
Danger Plates with Clamps
Anti- Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm
Painting of 8 mtr ST poles including crossarms/clamps with one coat of Red oxide Paint.
Painting of 8 mtr ST poles including crossarms/clamps with two coat of Aluminium Paint.
LT line spacers
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of LT line 3 phase 4 wire on 8 mtr long ST poles at Jadsarkote Madeen Block Tikri.
8 mtr. Long ST Pole (ST-410 SP15)
GI M-Clamp for shackle insulator
0.03 ACSR Conductor Weasel.
Shackle Insulators
Galvinized Nuts and Bolts.
Danger Plates with Clamps
Anti- Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm
Painting of 8 mtr ST poles including crossarms/clamps with one coat of Red oxide Paint.
Painting of 8 mtr ST poles including crossarms/clamps with two coat of Aluminium Paint.
LT line spacers
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV line on 9 mtr long ST poles for creation of 250 KVA Sub Station at Roun-II.
9 mtr. Long ST Pole (ST-410 SP33)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
0.03 ACSR Weasel conductor
11KV Pin Insulator (Polymeric) with Pins (12kv, 5KN) Creepage Distance 320mm
11KV Disc Insulators (Polymeric 45KN ) creepage distance 320 mm with tension fittings
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti- Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm
Painting of 9 mtr ST poles including crossarms/clamps with one coat of Red oxide Paint.
Painting of 9 mtr ST poles including crossarms/clamps with two coat of Aluminium Paint.
Cement bottoming of ST poles in 1:2:4 mix as per REC standards
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for creation of 250 KVA Sub Station at Roun-II Demand of Sarpanch Sh. Sansar Singh.
11/0.433kV, 3-phase 250 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Copper wound, and with LV Cable Box having detachable Aluminium Gland plate
Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
300 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type
9 mtr. Long ST Pole (ST-410 SP33)
11kV Polymeric composite Disc Insulator 12kV, min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with tension fitting
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution box for 250 DTR with MCCB for incomer and SFU's for outgoing circuits.
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Cement bottoming of ST poles in 1:2:4 mix as per REC standards
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 50 mm x 6 mm & 32mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Painting of sub station ST poles/cross arms/clamps with one coat of Red oxide and two coats of aluminium paint
Danger Plates with Clamps
Anti-Climbing Devices with Clamps
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of LT line on 8 mtr long ST poles at Roun-II Demand of Sarpanch Sansar Singh.
8 mtr. Long ST Pole (ST-410 SP15)
GI M-Clamp for shackle insulator
0.03 ACSR Conductor Weasel.
Shackle Insulators
Galvinized Nuts and Bolts.
Danger Plates with Clamps
Anti- Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm
Painting of 8 mtr ST poles including crossarms/clamps with one coat of Red oxide Paint.
Painting of 8 mtr ST poles including crossarms/clamps with two coat of Aluminium Paint.
LT line spacers
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
AJAY KAPOOR
T AND D CONSTRUCTIONS AND TRADING COMPANY
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .