Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAccepted-AOC | ₹2.4 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹2.4 Cr+₹1.6 L (0.66%)Rejected-Finance | ₹2.4 Cr+₹1.6 L (0.66%) | L2 | Rejected-Finance Being not L1 |
| 3 | L3₹2.5 Cr+₹6.6 L (2.75%)Rejected-Finance | ₹2.5 Cr+₹6.6 L (2.75%) | L3 | Rejected-Finance Being not L1 |
| 4 | L4₹2.5 Cr+₹9.4 L (3.88%)Rejected-Finance | ₹2.5 Cr+₹9.4 L (3.88%) | L4 | Rejected-Finance Being not L1 |
| 5 | L5₹2.5 Cr+₹12.9 L (5.34%)Rejected-Finance FLAT NO 03 PANCHAVATI BUILDING ADARSH NAGAR CHICALIM GOA 403711 | SOUTH GOA | GOA | 403711 | ₹2.5 Cr+₹12.9 L (5.34%) | L5 | Rejected-Finance Being not L1 |
Tender Value
₹2.7 Cr
EMD Value
₹3.4 L
Closing Date
14 Nov 2023, 6:00 pmClosed
Neeraj Mehrotra, IDSE, CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
PROVISION OF PRE FAB STRUCTURE FOR AT ATS BELAGAVI
2023_MES_621292_1
81221/E8
Open Tender
Civil Works
Lump-sum
365 days
GE (AF) Sambra, Belgaum
As per tender documents
7 documents required · 7 mandatory
₹2,000
GE (AF) Sambra
₹3.4 L
17 Jan 2024
2 Oct 2023
21 Nov 2023
2 Oct 2023
14 Nov 2023
30 Oct 2023
2 Oct 2023 - 13 Oct 2023
Amount
GENERALSUMMARY Note : Schedule ‘A’ Part I to be quoted by contractor under Col 6.Schedule 'A' part II to part V are prepriced by MES under Ser No. 2 to 5. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Design, fabrication, Supply and erection of Pre Engineering building, steel structure complete all as specified and shown in drawing including the followings - (a) Galvalume or Zincalume profile colour coated steel sheet 0.68mm thick(Prepainted sheet) as outer sheet of PUF sandwich panel with colour as approved by GE. (b) Galvalume or Zincalume profile colour coated steel sheet 0.60mm thick(Prepainted sheet) as inner sheet of PUF sandwich panel with anti reflective GOO Black paint colour finish (c) Galvalume or zincalume profile colour coated steel sheet 0.68mm thick (prepained sheet) as PUF roof sheet with colour as approved by GE. (d) RCC, M-25 design mix in foundation. (e) 80mm thick PUF insulated panels in wall (f) Pre-construction ATT
Lumpsum price worked out by the contractor for “Internal Electrification” as listed in Schedule ‘A’ Part–II representing **______________% (_______________________)* above/below the lumpsum price of Rs.5,38,877.20 inserted by MES for Schedule 'A' Part-III.
Lumpsum price worked out by the contractor for “Roads / path / Culvert ” as listed in Schedule ‘A’ Part–III representing **______________% (_______________________)* above/below the lumpsum price of Rs.14,95,442.94 inserted by MES for Schedule 'A' Part-VI.
Lumpsum price worked out by the contractor for “Area Drainage” as listed in Schedule ‘A’ Part–IV representing **______________% (_______________________)* above/below the lumpsum price of Rs 20,38,512.74 inserted by MES for Schedule 'A' Part-VII.
Lumpsum price worked out by the contractor for “External Electrification” as listed in Schedule ‘A’ Part–V representing **______________% (_______________________)* above/below the lumpsum price of Rs.5,74,554.77 inserted by MES for Schedule 'A' Part-VIII.
SCHEDULE `A' PART - VI MISCELLANEOUS ITEMS items are not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
S & F of DWC Pipe (IS-16205), inner dia 50 mm, outer dia 63mm for cable protection in wall/under gorund laying of UG cables including SNAP- FIT Coupler and all fittings as required at site complete all as specified and as directed.
S & F of DWC Pipe IS-16205, size inner dia 32 mm, outer dia 40 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed by Engr-in-Charge.
Supply , install, testing and commissioning of LT feeder pillar box AC 415 V , 50 HZ 3 Phase 4 wire of suitable size for accomodating the following accessories totally enclosed self supporting structure / cubicle , fully compartmentalized type , suitable for outdoor use , with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm , with four legs grouted to PCC (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter , changeover switch and MCCBs , hinged doors at front with suitable locking arrangement , Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated , complete with followings :-
(a) BUSBAR - Aluminium bus bar 200 Amps (20x10mm), supported on non hygroscopic fibres and brass screws for mounting - 04 Nos
(b) INCOMINGS - (i) MCCB of 4 pole of capacity 100 amps with breaking capacity of 16 KA Adjustable thermal and Adjustable magnetic setting - 01 Nos (ii) LED Indicating lamps for Main Supply indicating R, Y, B - 03 Nos (iii ) Digital Ampere Meter 3 ½ digit display , incl CT having CTR 100/5 - 01 Nos (iv) Digital Voltmeter 0-500 Volts , SIF 96 - 01 Nos (v) 100 A on Load change Over Switch 4P - 01 No
(c) OUTGOING FEEDERS (i) Supply and fixing MCB SP, 230 volts of capacity 06 to 32 amps B Curve - 05 Nos
Supply, install, testing and commissioning of acoustic proof diesel engine driven generating set, fully wired, 415 Volts, AC, 3 phase 4 wire, 50Hz having capacity 32KW/40 KVA continous rating at power factor 0.8 (lagging) as per IS-4722 and connections as per IE rules complete with liquid cooled 4 stroke Diesel engine with electric start with 12V DC battery, developing minimum 52 BHP at 1500 RPM under NTP prevailing at Sambra area, Belagavi considering derating factor and shall conform to IS:10000/150 3026/BS-5514 with provisions of 10% over loading for 1 hour for every 12 hours running with A1 class governing and all standard safety type, screen protected, revolving field, self excited, self regulated alternator conforming to BSEN-60034 with IP 23 protection complete with integrated AMF control panel with microprocessor based relays/MCCB/MCB's/Contactors, multifunction meter showing KWH, KVA, PF, Amps, Volts, frequency, indicating lamps, 12 Volt battery charging unit including 12 Volts battery etc required asper latest standard engineering practices including sound proof canopy designed to meet MoEF/CPCB Norms of 75 dBA at 1mtr at 75% load, fabricated from CRCA sheet and a structural/sheet metal base frame, with high quality noise absorbent and fire retardant grade acoustic insulation material conformity to IS : 8183 and integrated fuel tank of capacity not less than minimum 8 hrs running fuel filling arrangement from inside duly painted after necessary pre treatment process complete all as specified and as directed. Make : Cummins / Kirloskar / Greaves Cotton / Ashok Leyland Make of Alternator: Stamford (CGT)/ Kirloskar / Crompton Greaves
Notes : (i) The cost of PCC foundation as per the recommendation of OEM shall be deemed to be included in the quoted rate. (ii) Cost of fuel and other expenses for carrying out acceptance test of the DG set shall deemed to be included in the quoted rate. (iii) The DG set will be provided with RECD as per latest PUC norms and cost deemed to be included in the quoted rate.
Supply & fix Air Circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting complete all as specified & directed. Make-Havells 450mm Turboforce
TECHNO FAB
KARNI BUILDERS
Vinayaka Enterprises
M/s. P S REDDY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .