Loading…
Loading…
Updated dates
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
11 Jun 2026, 6:00 pm6d left
GE AF JAMMU
GE AF JAMMU
REPAIR REPLACEMENT OF SECURITY LIGHTS, RO PLANTS, DG SETS, BOILERS, EARTHING PITS AND MISC WORKS AT SHASHITHAR AND SALYARCHATTA UNDER GE AF JAMMU
2026_MES_764909_1
CA NO GE/AFJ-13/2026-27
Open Tender
Civil Works
180 days
SALYARCHATTA AND SHASHITAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF JAMMU
₹72,000
Yes
12 May 2026
12 May 2026
15 Jun 2026
12 May 2026
11 Jun 2026
28 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Attending complaints for checking of existing electrical points wiring in any Buildings/Pole for continuity ,no light including carrying out minor repairs etc as required to make the item functional and replacing burnt wire ends, small pieces of wire, tightning of loose connections etc all as specified. Note - Contractor has to deploy Qualified Electrician and Helper with all necessary tools on all days to the complaint cell and complaints will be attended on the same day itself. Recovery for non attending complaints will be three times rate quoted by the Contractor. | 400 | Each Job | - | - |
| 2 | Dismantling and taking down the existing defective street light/security light fitting of any type and any capacity fixed at any height by replacing UNSV part including perpex cover checking loose connection etc, restroration of electric supply, detecting and repair of UG cable fault whenever required round the clock all as directed at site on daily complaint basis. | 344 | Each Job | - | - |
| 3 | S&F in repairs 45 watt of new street light/security light incl making electric connection using two run of 1.5 sqmm single core unarmoured wire from junction box complete all as specified and directed by Engr-in-Charge. | 60 | Each | - | - |
| 4 | S&F in repairs 60 watt of new street light/security light incl making electric connection using two run of 1.5 sqmm single core unarmoured wire from junction box complete all as specified and directed by Engr-in-Charge. | 75 | Each | - | - |
| 5 | S&F in repairs 100 watt of new street light/security light incl making electric connection using two run of 2.5 sqmm single core unarmoured wire from junction box complete all as specified and directed by Engr-in-Charge. | 20 | Each | - | - |
| 6 | S&F in repairs 100 watt of new LED Flood light fitting incl making electric connection using two run of 2.5 sqmm single core unarmoured wire from junction box complete all as specified and directed by Engr-in-Charge. | 4 | Each | - | - |
| 7 | M&L for repair to existing LED street light fitting 45 Watt to 60 Watt of any make including supply and replacement of driver and other minor allied items required at site to make the light fitting serviceable complete all as specified and directed by Engineer-in-Charge. | 70 | Each | - | - |
| 8 | M&L for repair to existing LED street light fitting 90 Watt to 100 Watt of any make including supply and replacement of driver and other minor allied items required at site to make the light fitting serviceable complete all as specified and directed by Engineer-in-Charge. | 65 | Each | - | - |
| 9 | M&L for repair to existing LED Flood light fitting 100 Watt of any make including supply and replacement of driver and other minor allied items required at site to make the light fitting serviceable complete all as specified and directed by Engineer-in-Charge. | 20 | Each | - | - |
| 10 | S&F Sub main wiring with two single core PVC insulated unshesthed cable copper conductor(FRLS-H) of size 2.5 sqmm multistranded and one run of 2.5 sqmm PVC insulated unsheathed copper conductor(FRLSH) as earth continuty conductor drawing in and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories concealed in wall, cutting of chases in walls, floors, ceilings, beams etc and making good the disturbed surfaces as directed including taking down old unservicable wiring complete all as specified and directed. (Two run of single core cable and one run of earthing cable and one run of PVC conduit shall be measured as one length.) | 140 | RM | - | - |