Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹6.2 L+₹18,058.50 (3.01%)Rejected-Finance 41B 1H JAYANTIPUR PREETAM NAGAR ALLAHABAD | L2 | Rejected-Finance Being Not Lowest | |
| 3 | L3₹7.0 L+₹1.0 L (16.9%)Rejected-Finance | L3 | Rejected-Finance Being Not Lowest | |
| 4 | L4₹7.7 L+₹1.7 L (27.6%)Rejected-Finance | L4 | Rejected-Finance Being Not Lowest | |
| 5 | L5₹9.4 L+₹3.4 L (56.7%)Rejected-Finance | L5 | Rejected-Finance Being Not Lowest |
Tender Value
₹9.8 L
EMD Value
₹19,600
Closing Date
31 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Vijendra Arya, AGE (I)
AGE (I) Manauri Allahabad-212212
REPAIR / MAINT OF LT DISTRIBUTION NETWORK WITH ALL CONNECTING WORK IN TECH AREA AT 24 ED UNDER AGE(I) AF MANAURI
2021_MES_456347_1
8914/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Manauri, Allahabad
Class E, Cat b (i)
7 documents required · 7 mandatory
₹500
AGE (I) AF Manauri
₹19,600
Yes
4 Sept 2021
1 Jul 2021
2 Aug 2021
1 Jul 2021
31 Jul 2021
19 Jul 2021
60 days
Amount
Excavating in trenches not exc. 1.5m wide and not exc. 1.5 metre deep and getting out in soft/loose soil complete.
Returning filling in foundation/trenches including spreading leveling, watering and well ramming in layers not exceeding 25cm thick in soil complete.
Removal of surplus excavated material to a distance n.exc. 50 metre and depositing where directed at a level n.exc. 1.5 metre above starting point complete.
M & L for sand cushioning for under ground cable with locally available sand for protection of cable 8cm before laying cable and 15cm deep over the cable including spreading and consolidations, complete. (Note-Punned thickness ie 180mm will be measured and paid)
M&L for brick protection cover over cable of old size Bricks” laid dry over LT cable width of brick shall be laid across the length of cable) complete all as specified and as directed.
Cutting/boring to plinth protection/hard standing/road etc in suitable depth and crossing of GI pipe of size 150 mm bore so that XLPE underground cable can be passed and giving mechanical protection to cable complete all as specified and directed. Note:- Quoted rate shall be included the cost of required material for repairing to disturbed surface all as per existing specification and GI pipe shall be measured and paid separately under respective items.
Supply, laid in trench /fixed in replacement with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with aluminium conductor 1100 volts heavy duty multistranded, grade cross section area 4 core x 25 Sqmm (earthed) complete all as specified and directed.
All as per item No 7 above but size of cable 3.5 core x 50 Sqmm (earthed)
All as per item No 7 above but size of cable 3.5 core x 70 Sqmm (earthed)
All as per item No 7 above but size of cable 3.5 core x 95 Sqmm (earthed)
All as per item No 7 above but size of cable 3.5 core x 120 Sqmm (earthed)
Supply & fixed in replacement 40 MM dia bore GI tubing 'light grade' with fixing accessories laid in trenches or on wall or pole with clamp 02 Nos made out of GI strip of size 25x3.15mm complete all as specified & directed.
All as per item No 12 above but of 50 mm dia bore
All as per item No 12 above but of 80 mm dia bore
M & L Painting to existing steel pole of 9 mtr height including mild steel work like cross arms, clamps, pipe channel, bracing etc after cleaning and prepration of surfaces painting externally above planting depth with two coat of aluminum paint over a coat of aluminum primer including preparation of existing surfaces and marking pole numbers in 15 cm dia with approved colour in circular and making 03 Numbers & 02 Numbers of bands & strips with 30 cm wide black paint from bottom of pole to 1.5 mtr height of pole complete all as specified and as directed. Note : Cutting of bushes & tree branches upto 3 Mtrs height of pole shall be deemed included in quoted unit rate.
Supply & fixing in replacement of aluminium conductor steel reinforced (ASCR) in any specification making interconnection of network fixing on existing structure/pole including taking down existing ACSR conductor any type complete all as specified and directed. Note: Sagging length of ACSR conductor shall be deemed included in the quoted unit rates & in this regard no extra length shall be measured & recorded.
M & L for earthing complete with galvanized steel earth plate electrode of size 60 CM x 60 CM x 6 MM thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below the ground level) with top edge of earth plate not less than 1.50 Mtrs below normal ground level connected to galvanized earth lead strip 32 x 6 MM size by means of nut, bolts & check nuts and washers of galvanized iron or steel connected to earthing test point complete all as specified or indicated, including earthing pit with PCC 1:3:6 type C 1 using 20 mm graded stone aggregate & RCC cover slab 40 MM thick as in RCC 1:2:4 type B-1 using 20 MM graded stone aggregate, reinforced with 8 MM dia TMT bars @ 150 MM centre to centre both way with two Nos lifting handle, GI pipe 20 MM dia 'light grade' with funnel and wire mesh for watering and 40 MM dia 'light grade' GI pipe for GI earth strip 32 x 6 MM protection etc complete all as shown in electrical plate No. 3 of SSR Part - I (2009) including testing on completion including dismantling of old existing earthing complete all as specified and directed. Note:- Items includes cost of 7.5 metre galvanized earth lead strip 32 x 6 MM.
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chasses or buried in ground or drawn in conduit / pipes or fixed to pole or any other indicated situation for loop earthing etc for galvanised earth strip 32x6mm including taking down existing strip complete all as specified and directed.
M&L for erection in position of true vertical swaged tubular pole type 410 SP-31 [9 m long] complete with cast iron base plate, finial taper plug, bolts, nuts and screws and top cover complete including taking out old pole any type from ground and making good disturbed surface complete all as specified & directed including following:-
[a] Excavation in trenches not exceeding 1.5 mtr wide & 1.8 mtr deep for pole foundation & getting out soft loose soil, returning filling soil in the trenches after fixing of pole in foundation ramming earth around the layers not exceeding 25 cm thick and disposal of surplus soil to a distance not exceeding 50 m. [b] M&L providing PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation 600 mm x 600 mm cross section planting depth 1.8 m for concrete casing the pole up to ground level. [c] M&L providing PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth band/ collar 300 mm high from ground level & 450 mm dia. [d] M&L painting of pole on external surface with one coat of black bituminous paint [up to planting depth] and above plinth band/ concrete collar with two coats of aluminium paint over a coat of red oxide primer including preparation of steel surface and painting with synthetic enamel paint blue colour, circular band three number of 30 cm wide in alternate layer up to height of 1.5 m above plinth band of pole. [e] Material & labour writing letter or figures/ pole number [Block, Roman, Italic as Indian] with thick synthetic enamel paint of approved shade not exceeding 30 cm. Note: (i) Old dismantled portion of LT poles in grounds shall be filled with PCC (1:5:10) type E-2 using 40 mm graded stone aggregate. Cost of PCC filling shall be deemed included in quoted unit rate (ii) Rate shall be deemed to include cost of Eearth work, PCC & other work as mentioned here-in before (a) to (e) under this item.
S&F in replacement of cross arms bracing, supports, clamps and back plate fabricated from structural steel section including nut & bolts, washers, welding, bending, cold or hot, drilling hole for bolts in any shape or size as indicated over and including of two coat of synthetic enamel paint over a coat of primer red oxide complete all as specified and as directed.
S&F in replacement MCCB, 4 pole, 63 Amp rating having breaking capacity of 16 KA, 415V adjustable thermal process based magnetic setting type Ics=75% Icu complete all as specified aid directed. Make: Legrand Cat part No 420013 or equivalent in makes as specified in list of make Appendix 'B' to particular specifications.
All as per item above but 4 pole 415 Amps 125 Amps rating having breaking capacity of 25 KA, 415V. Make: Legrand or equivalent in makes as specified in list of make Appendix 'B' to particular specifications.
S&F in replacement MCCB, 4 pole, 250 Amp rating having breaking capacity of 36 KA, 415V adjustable thermal process based magnetic setting type Ics=75% Icu complete all as specified and directed. Make: Legrand Cat part No 420249 or equivalent in makes as specified in list of make Appendix 'B' to particular specifications.
Supply, Installation, testing and commissioning of LT bus bar chamber in cubical housing cabinet, outdoor type, double door platform mounted (minimum height 45 cm above normal GL and 30 cm below normal GL) , CPRI approved factory made, totally enclosed, dust and vermin proof made out by 3.15 MM thick CRCA MS sheet and full built upon angle iron frame in size 40 x 40 x 6 MM, having front and rear hinged both side openable doors and lifting lugs (02 Nos) , locking arrangement to be connect to earthing strip at rear side, bottom detachable both side openable, gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers sheet steel bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment. The panel shall be epoxy powder coated and the control circuit shall be connected by suitable size of copper strip in proper colour coding and drawn through in flexible conduit. The panel should be suitable for 415 volts ,50 Hzs, 3 phase, 4 wire system, making incoming and outgoing connection using gland in suitable size including grouting KIOSK on floor (60 CM above the ground surface) in floor angel iron 50 x 6 MM imbedded to fixed the KIOSK with nut bolt, floor PCC (1:2:4) type B1 using 20 MM grade stone aggregate ( minimum 50 CM above GL and 30CM below GL) complete including taking out of old chamber comprising the following items:-
(a) 04 Nos bus bar made out by aluminium strip in rating 300 Amps rated colour coding mounting on heat shrinkable insulators both side and PVC sleeving-01 Set. (b) LED indicating lamps of 'R', 'Y' and 'B' phase. Set of three -01 (f) MCCB, 415 volt , 4 poles 125 Amps , 25 KA breaking capacity, thermal based microprocessor based operated Ics=100% Icu complete- 01 Nos incommer. Note : (i) Chamber drawing shall be approved by Deptt for size and all Tech specification before placing order (ii) All MCCB shall be confirming to Icu 100% and IEC 60947 -2 in compact series. (iii) All out going feeder shall be connected by cable through suitable size of gland plate/glands. (iv) The various feeder shall be indicated by 50mm size letters in synthetic enamel white paint. Make for MCCB & others : as per specified in list of make Appendix 'B' to particular specifications. (Location- Main Panel behind AOC office)
Repair & painting using synthetic enamel paint in two coats in existing colour over one coat of red oxide primer of external surface and black colour on internal surface to LT panel/ bus bar chamber and making locking arrangement of LT panels/ bus bar chambers of upto overall indicating size 1000x900x450mm including jointing / welding and fixing with nut bolt all as per required at site to make door easily openable and close. Note:- Quoted rate shall deem to incluede cost of all required material and T&P.
Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri if not mentioned in BOQ.
Bharat Trading Company
SHAM AND SONS ENGINEERING WORKS
M/S AM ENTERPRISES
M/S Garg Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .