GE (AF) Halwara
GE (AF) Halwara
REPAIR TO MISC EM WORKS EARTHING INFRASTRUCTURE AND STEET LIGHT FITTINGS ETC AT AF STN BARNALA UNDER GE AF HALWARA
2019_MES_310731_1
GE/HAL-59/2019-20
Open Tender
Civil Works
Item Rate
273 days
GE (AF) Halwara
MES ENLIEST CONTRACTORS CLASS E b i
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹50,000
Yes
16 Mar 2020
31 Dec 2019
5 Feb 2020
31 Dec 2019
4 Feb 2020
14 Jan 2020
Amount
Taking down of XLPE insulated heavy duty electric cable with aluminium conductor 1100 Volt garde cross sectional area is any type and any size Note :- Earth work will be measured separtealy at item No.6
XLPE insulated heavy duty electric cable with aluminium conductor 1100 volt grade cross sectional area 50Sq mm 4 core.
XLPE insulated heavy duty electric cable with aluminium conductor 1100 volt grade cross sectional area 35Sq mm 3.5 core.
XLPE insulated heavy duty electric cable with aluminium conductor 1100 volt grade cross sectional area 25Sq mm 3.50 core.
XLPE insulated heavy duty electric cable with aluminium conductor 1100 volt grade cross sectional area 6Sq mm 2 core.
Excavation in trenches n exc 1.5m wide and n.exc 1.5m in depth for cable,etc n.exc 10sqm on plan and n.exc 1.5m depth and getting out soft.looser soil for cables etc.
Returning filling in including spreading,leveling watering and well ramming in layers not exc 25cm
Removing excavated material n exc 50m and depositing where directed at a level in exc 1.5m above the starting point.
Supply and spreading of fine river sand and gentally punning for laying of under ground cables. Note :- Punned thickness 18cm shall be measured for payment.
Supply and laying sub class 'B'common burnt bricks, old size designated 75, laid dry flat with width equal to length of brick & with gaps between the adjucent bricks n.exc 10mm as cover laid over the cable to give mechanical protection to under ground cable complete.
Replacement of MCCB 800Amp TPN 415 Volt breaking capacity 50 KA.
Restreaching/tightening and fixing in position, the existing over head ACSR conductor LT line 3 phase with neutral and earth wire 440 V 5/6 wire by lossing and taking down existing binding wire from the insulator of any size of ACSR conductor and bring it to required sag including new binding wire and tightening of cross arm on each pole including trimming of tree branches touching with the wires if any completeall as specified and directed. Note : Span length (any No of wire) of conductor shall be measured in Running Meter combined unit and unit rate quoted by the contractor shall include for cutting and trimming branches of trees coming in contact with ACSR conductor.
Dismantling of unserviceable wornout/damaged ACSR conductor service feeder of any size from pole after disconnecting of jumpers and insulators etc complete all as specified and directed.
ACSR conductor of any size including all binding wires and aluminium jointing jupering etc on LT lines complete all as specified and directed.
Dismantling insulator any type any size complete all as specified.
Pin type proccelain insulator of size 63mm dia,100mm height vitreous White brown or green including one galavnized mild steel spindle, two galvanized iron washer and one galvanized iron nut for 1100 volts grade complete all as specified and directed.
Shackle type insulator procelain vitreous White brown or green 90mm dia 75mm height for working pressure of 1100 volts including galvanized steel strips of section 31x3mm,12mm dia bolts, washers and nuts complete all as specified and directed.
Loop type insulator,vitreous porcelain, white,brown or green small size with overall dimensions 65x90mm, clearance of hole 16mm complete all as specified and directed.
S&F of 90 watts 6000 K LED street lights.
S&F of 90 watts 3000 K LED street lights.
Replacement of 40mm dia tubes light grade "galvanised pipes for protection of Cable on roads.
Material & labour. Welding on both sides (over lapping) to the GI strip of any size as earthing lead including dismantling the old from the existing position/equipment without disturbing the functional requirements of the equipments and reconnecting after repair/welding complete all as specifed and directed.
Material & labour,brazing/soldering on both sides (over lapping)to the copper strip of size 20mmx3mm & 25mmx3mm as earthing lead including dismantling the old from the existing position/equipment without disturbing the functional requirements of the equipments and reconnecting after repair/brazing complete all as specified and directed.
Material & labour, Earth continuity conductor or main earthing lead or lighthing conductor,32mmx6mm GI strip, fixed to wall on batten with saddles and fixing screws or PVC/Porcelain insulators etc or recessed or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing or roof conductors & down conductors etc as required including welding on both sides (over lapping) at all joints except test point fixed as in replacement of existing strip complete all as specified and directed.
Material & labour, Earth continuity conductor or main earthing lead or lighthing conductor,25mmx3mm copper strip, fixed to wall on batten with saddles and fixing screws or PVC/Porcelain insulators etc or recessed or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing or roof conductors & down conductors etc as required including welding on both sides (over lapping) at all joints except test point fixed as in replacement of existing strip complete all as specified and directed.
S&F GI Pipe 25mm bore light grade (ISI marked) cut piece of 3.5 metre to 4 mtr length fixed vertically with bottom end fixed to paretpet wall/roof of the blgd with suitable clamps & fasteners or PCC work for stragiht vertical erection as directed by Engr-In-Charge and other end (at top) fixed to air termination rod with necessary bolts, nuts etc as required complete all as specified and directed.
S&F in position at various/different locations pit cover with lifting handle of pre-cast RCC (1:1:5:3) mix along with lifiting handle using 20mm graded crush stone aggragate type A-1 and reinforced with XPM weighing not less than 4Kg/Sqm, and replacing existing earth pit cover for replacing broken/unserviceable pit cover complete all as specified and directed.
Replacement of broken/damaged. Test point terminal block made of gun metal or phosphourus bronze 75x75x25mm drilled and screwed incl 3 nos 8mm dia 25mm long hex head screw all as specified and directed by Engr-in-Charge.
S&F in position at various/different locations funnel alongwith wire mesh and replacing existing broken/damaged items complete all as specified & directed.
S&F in replacement of juction box on existing pole of minium size 300mmx200mmx150mm made out of 1.6mm thick MS Sheet duly painted with 2 coat of synthetic enameled paint over one coat of red oxide outdoor type lockable complete with fixing arrangement with 100Amps capacity aluminium busbar 4 Nos and One Nos10Amps MCB SPN including clamps made out of flat iron 25x3mm & nuts bolts,washers and thinbles etc complete all as directed by Engr-In-Charge.
Dismantling the burnt synchornizing power monitor from PLC Panel by isolating power supply and replace the same with new power monitor and testing of PLC panel for proper operation of the panel through OEM service complete
Supply and replacement old UNSV 12 volt, 45AH battery
Supply only aluminium lugs size 50Sqmm
Supply only aluminium lugs size 35Sqmm
Supply only aluminium lugs size 25Sqmm
Supply only aluminium lugs size 16Sqmm
Supply only aluminium lugs size 10Sqmm
Supply only aluminium lugs size 6Sqmm
Supply only Electric Shock first treatment chart complete all as directed by Engr-In-Charge.
Repair and replacement contactor of steet light panels as per existing model.
Supply only LT insulation tape size 35mm width Appx 15 Mtr length.
Supply only HT insulation tape size 35mm width Appx 15 Mtr length.
M&L for surface dressing not exc 15 cm deep and 2.50x2.50 meter surrounding area of street light pole/stay and panel boards including cutting and cleaning away grass,bushes,small plant,vegetable shrubs bushes of under roots all as specified and directed by Engr-In-Charge.
M&L for Earthing complete with galvanished steel earth plate electrode 60cmx60cmx6mm thick buried dirctly in ground earth pit less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4.00mm dia by mean of nut,bolt,washer all as shown in electrical plate No.5 including testing on completion
M&L for Earthing complete with galvanished steel earth plate electrode 60cmx60cmx6mm thick buried dirctly in ground earth pit less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanised earth strip 32x6mm by mean of nut,bolt,washer all as shown in electrical palte No.5 including testing on completion.
Repalcement of PVC LT 4 way line spacer.
Repalcement of earthing insulator/saddels for roof conductor and down conductor.
S&F standard danger notice plate as per IE rules 1956 for 11000 Volt & 440 volt with warning write in 3 language (Engilish, Hindi,Punjabi) of approved size 25cmx20cmx1.6mm thick mild steel sheet vitrous enamlled white, with letter,figures and conventionla skull and bones in singnal red colour and fixed with MS clamp,bolts and nuts complete all as directed. Note :- warning sign must be reflective & clearly visitable at night.
Supply and replacement of Computerised Distribution chart in r/o sub station with clear glass cover & wooden frame complete all as specified and directed by Engr-In-Charge. Note :- Rough distribution sketch to be given by Dept.
Supply & replacement of name board with in built LED lights of r/o main power house sub stations and Pump Houses with fitted required height of angle iron
Replacement for rubber mat size 2 Mtrx1Mtrx25mm thick confirming to IS 5424/69 for electrical insullations complete all as specified.
M&L for online centrifuging(filtration/dehydration) of transformer oil including checking directly electric strength of oil before and after filtration for transformers located in Minniebay area with suitable machine having filtration,heating and pumping facility to improve the dielectric strength/insulation valve of oil. Note :- (i) DI-electric strength of oil afteriltration/dehydration shall be not less than 60KV/min (ii) The contractor shall take shutdown orders in writing from Engr-in-Charge before commencement of the work. (iii) The contractor shall ensure no wastage of transformer oil. (iv) The di-electric strength of shall be tested before & after filtration and test resuilt shall be submitted to Engr-In-Charge.
Supply & fitting new transformer oil for topping up the transformers duly filtered with filtration plant having delictric strength not less than 60KV complate all as specified and as directed (Make Power Oil/Electrol/Servo) Note :- (a) The transformer oil shall be type EHV conforming to IS-335/1983. (b) Mineral oil grade shall be used. (c) The IR valve of transformer oil shall not be less than 60KV/min. (d) The unit rate shall be deemed to include the cost of filtration to cashive desired di- electric strength.
Supply and fill silica gel in breather of transformer all as specified. Note :- The silica gel shall be brought in air tight container.
M&L for spary painting with silicon acrylic heat resistant paint of approved quality & colour to indoor/outdoor step down transformer of 100 to 250KVA capacity installed at different location of AGE E/M Barnala under GE (AF) Halwara after throughtly scraping the existing corroded paint/rust filling of cavities complete incl writing the details such as SM/MES No all as specified and directed.
M&L for spary painting with silicon acrylic heat resistant paint of approved quality & colour to indoor/outdoor step down transformer of 500KVA capacity installed at different location of AGE E/M Barnala under GE (AF) Halwara after throughtly scraping the existing corroded paint/rust filling of cavities complete incl writing the details such as SM/MES No all as specified and directed.
S& replacement in silica gel breather assembly transparent type with first fill of silica gel suitable for 100 to 250 KVA transformer complete incl connecting with proper rubberized gasket complete all as specified and directed.
S& replacement in silica gel breather assembly transparent type with first fill of silica gel suitable for 500KVA transformer complete incl connecting with proper rubberized gasket complete all as specified and directed.
Supply and replacement of LV side gun metal/brass threaded studs of rating 11KV 250A to 400Amps of suitable size and length incl proclin insulater metal rings bolts,washer,rubber rings, etc complete all as specified and directed suitable for indoor/out door type step transformer of any make/model.
Supply & replacement of LV side gun matel/brass threaded studs of rating 11 KV 630 A to 1000 Amps of suitable size and length incl proclin insulater, metal rings,bolts,washer,rubber rings,etc complete all as specified and directed suitable for indoor/out door type step down transformer of any make/model
Rewinding of Electronic hotter 3 phase 35HP 50 c/s with PVC insulated copper wire of suitable gauge and size as per existing including all insulating material and replacement of ball bearing,bushes,greasing and testing complete Note :- Rate quoted by the contractor shall to be deemed to be include, including minor items like nut bolts packing etc and taking down and reflxing of electric hotter is included in quoted rate.
S&F of GI cover on both primery & secondary side of transformer upto 250KVA transformer Note :- Rate quoted by the contractor shall deemed to be include, including minor items like nut bolts packing.
S&F of GI cover on both primery & secondary side of transformer exceding 250KVA transformer Note :- Rate quoted by the contractor shall deemed to be include, including minor items like nut bolts packing.
S&F of transformer wheels as per existing size all are specified and directed. Note :- Rate quoted by the contractor shall be deemed to be include,including minor items.
Supply and replacement of oil gauge of transformer as per existing model of any capacity transformer all are specified and directed and making it fully fuctional. Note :- Rate quoted by the contractor shall be deemed to be include,including minor items.
Supply & replacement of Temp gauge of transformer as per existing model of any capacity transformer all are specified and directed and making it fully fuctional. Note :- Rate quoted by the contractor shall be deemed to be include,including minor items.
S K BANSAL AND CO.
m/s k.k. construction co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .