| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 LAccepted-AOC BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | HOWRAH | WEST BENGAL | 711113 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹14.5 L+₹3.3 L (29.8%)Rejected-Finance 33 PEMANTLE STREET KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹15.2 L+₹4.0 L (35.6%)Rejected-Finance | L3 | Rejected-Finance 3rd Lowest |
Tender Value
Refer Docs
EMD Value
₹35,000
Closing Date
1 Jul 2019, 5:00 pmClosed
EE KED
New Building Erstwhile CGA Office 1st. Floor Writers Buildings Kolkata 700 001
Replacement of old 5.5ton capacity Ductable air conditioning machines and allied work at Traffic Control Room at Traffic Building Kolkata Police HQ under Lalbazar Electrical Section I PWD AC Portion
2019_WBPWD_228392_1
WBPWD/EE-KED/e-NIQ-05/2019-20
Open Tender
A/C ORG
Item Rate
15 days
Traffic Building Lalbazar Police Head QUarter
Please refer Tender documents.
4 documents required · 4 mandatory
₹35,000
Yes
17 Aug 2022
14 Jun 2019
4 Jul 2019
14 Jun 2019
1 Jul 2019
18 Jun 2019
Amount
Supply & delivery of 4 way Cassette type 4 ton capacity Hybrid Air conditioner with Super Tropical - Return Cooled- Scroll Compressor, 48000 Btu/h, Rated Cooling Capacity 12500 Watt, Indoor unit Airflow 2500 CMH, Super turbo DC Fan Motor Speed Auto/High/ Medium/ Low/Dry, Refrigerant R-410, 6 point Multi port Refrigerant inject coil, (Make:- Mitsubishi Heavy Duty-FDT125CR-S/FDC125CR-S / O-General - AUG54FUAS)
Installation the Indoor unit by hanging with full threaded 10 mm. stick with necessary nut & washer, after Installation the Outdoor unit Installation, Commissioning the units & pipe line testing the leack on high pressure testing up to 500 psi by Nitrogen gas and double stage vacuuming indoor unit and pipe line at least -50 psi, before release the refrigerant gas.
Supply & laying Refrigerant Copper Pipe ping minimum Thickness 1.42 mm. Liquid pipe 9.52 mm. (3/8")Gas pipe 15.88 mm. (5/8") [ Make Royku / Totaline/ Mandeep] and Insulation by nitril rubber of refrigerant Copper Pipeping minimum Thickness 9 mm. Liquid pipe 6.35 mm. Gas pipe 15.88 mm.[ Make Aroflex / Acoflex] also raping the insulation & Copper wire with GKB Gold raping tape as per direction of EIC.
Supply & drawing 4 core 1.5 sq. mm. P.V.C. insulated sheeted wire for connecting the outdoor to indoor communication supply (Make Heaves / Finolex) and connecting with suitable type copper lug.
Supply & laying 25 mm drain Water piping work out of UPVC/ HDPE hard pipes (Make HB / Supreme) incl. fitting , accessories bends, elbows, tees, flanges, tapings, etc. insulated with 9mm. Thick nitrile rubber tube insulation.
Supplying, fabrication & fixing 3. Nos. M.S U-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for installation of outdoor unit of split AC including cutting holes into Concleate wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with angle of 40 mm x 40 mm & 25 mm x 25 mm x 6 mm for making standing platform 5 Ft. length x 3 Ft. wreath and safety grill height 3Ft. & painting the same with 2 coats empanel paint.
MILLENNIUM AIRCON
HIMAYAN
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .