Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹13.2 L+₹1.9 L (16.7%)Rejected-AOC PLOT NO 39 SHRI SHIVE NAGAR 05 MOTI BANDHA MACHEDA HARMADA JAIPUR 302013 RAJ | JAIPUR | JAIPUR | RAJASTHAN | 302013 | L2 | Rejected-AOC Other than Lowest Bidder | |
| 3 | L3₹13.9 L+₹2.5 L (22.1%)Rejected-AOC | L3 | Rejected-AOC Other than Lowest Bidder | |
| 4 | L4₹14.2 L+₹2.8 L (25.1%)Rejected-AOC | L4 | Rejected-AOC Other than Lowest Bidder | |
| 5 | L5₹15.9 L+₹4.6 L (40.2%)Rejected-AOC | L5 | Rejected-AOC Other than Lowest Bidder |
Tender Value
₹18.5 L
EMD Value
₹37,000
Closing Date
5 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (South) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
CLEANING OF SEWAGE LINE AT QUEENS LINES AREA UNDER GE (S) JAIPUR AT JAIPUR MIL STN
2022_MES_551244_1
GE (S)/J-32P /2022-23 8754/E8
Open Tender
Civil Works
Item Rate
270 days
Jaipur
Class E and above and category
a (i)
9 documents required · 9 mandatory
₹500
GE (S) Jaipur
₹37,000
Yes
15 Oct 2022
10 Sept 2022
7 Oct 2022
10 Sept 2022
5 Oct 2022
23 Sept 2022
Amount
Cleaning and maintanance of sewage system including day to day complaints viz removing all type of blockage from wash hand basins, bottle trap, Gully trap kitchen sink, water closet, etc including sewage lines of any dia, up to First manholes, by providing all tools and plants including bamboos, iron rod, bucket, rope ladder and manpower as required etc (Note :- (i) Contractor has to provide minimum 2 Nos safaiwalas/sweepers daily for sewage cleaners to attend the sewage complaint received day to day by sub division. (ii) Any complaint which is not completed within two days from the date of issue of complaint. Compensation will be charged @Rs. 200/-per day for each complaint upto 02 days delayed and beyond 2 days and above every additional day delayed will be charged @Rs. 50/-per day each complaints. (iii) Nos of blockage/complaints cleared/attended per day as recorded in MB is to be paid to the contractor as each Job in one Bldgs/block etc which includes sewer line also. (iv) Cleaning of septic tank and soakage well/man holes are paid separately under relevant item here in after.
Cleaning of sewage line of 100mm dia SGWG /RCC NP 2 pipe or any other specification including removing all type of blockage from manholes, to manholes by manual and /or mechnical means including providing all tools and plants bamboos, iron rod, bucket, rope, ladder etc complete. Note :- Contractor has to depute extra labour for cleaning of sewage lines to clear the blockage in sewer lines as and when required and disposing off all sludge waste debries etc outside MD land and refixing MH cover complete.
Ditto all as per Item NO 02 above but 150 mm dia sewage line
Ditto all as per Item NO 02 above but 200 mm dia sewage line
Ditto all as per Item NO 02 above but 300 mm dia sewage line
M&L Scooping and taking out sludge and foreign material from manhole n. exc 1.5m depth and including removing and re-fixing of manholes covers etc and appliances required for safe disposal of sludge and foreign material by carrying out the same covered van/trolley out side defence land and it should be disposed off at distance not less than 1.5 KM away at such place which is not detrimental to public health and as per direction of Engineer-in-Charge. Note :- Net volume of internal size of each manhole, upto the depth of water from bottom shall be measured for payment purpose including dewatering and removing dry/wet sludge etc, complete all as specified and as directed by Engr-in-Charge.
All as per serial item No. 06 here-in-before but manholes depth exc 1.5 metre but n.exc 3.0 metre each
All as per serial item No. 06 here-in-before but depth exc 3.0 metre but n.exc 5.5 metre each
Scooping and taking out sludge and foreign material from septic tank, soak well and sump/well of any description of any depth but not exc up to 5.0 m and including removing and re-fixing of manholes covers, septic tank and soak well cover etc and appliances required for safe disposal of sludge and foreign material by carrying out the same covered van/trolley out side defence land and it should be disposed off at distance not less than 1.5 KM away at such place which is not detrimental to public health, complete all as specified and as directed by Engr-in-Charge. Note :- Net volume of internal size of each septic tank, soakage well, up to the depth of water from bottom shall be measured for payment purpose including dewatering and removing dry/wet sludge etc complete.
M&L making arrangement for bypass to nearest manhole or line to keep sewage flow continuous providing required necessary T&P such as portable pump set, flexible hose pipe etc all as required at pump set, flexible hose pipe etc all as required at site, complete all as specified and as directed by Engr-in-Charge. :-
Upto 30mtr distance
Beyond 30mtr but upto 60mtr distance
Excavation in trenches not exc.1.5 m wide and not exc.1.5 m in depth for foundation or for shafts, wells, manholes etc not exc 10 Sqm on plan and getting out in soft/ loose soil, complete all as specified and as directed by Engr-in-Charge.
All as per item no 11 above but depth exc 1.5 m and not exc 3m
All as per item no 11 above but depth exc 3.0 m and not exc 4.50 m
All as per item no 11 above but depth exc 4.5 m and not exc 6 m
Removal of excavated soil to a distance not exc. 50m and depositing where directed at a level n.exc 1.5 m from GL, complete all as specified and as directed by Engr-in-Charge.
Returning,filling in, including spreading, levelling watering and well ramming in layers n.exc 25 cm in soft/loose soil, complete all as specified and as directed by Engr-in-Charge.
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel( 1/2 round or 3/4 section ) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for 100 mm bore pipe, complete all as specified and as directed by Engr-in-Charge.
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel( 1/2 round or 3/4 section ) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for 150 mm bore pipe, complete all as specified and as directed by Engr-in-Charge.
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel( 1/2 round or 3/4 section ) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for 200 mm bore pipe, complete all as specified and as directed by Engr-in-Charge.
Demolition and breaking up drain pipes salt glazed ware RCC set in CM 100 mm bore pipe in trenches, complete all as specified and as directed by Engr-in-Charge.
Ditto all as per item no 20 but 150 mm dia
Ditto all as per item no 20 but 200 mm dia
M&L Concrete bed to 100mm dia drain pipes including packing under, & haunching against the sides of pipes after they are laid & tested; in PCC (1:4:8), type D1 complete all as specified and as directed by Engr-in-Charge.
M&L Concrete bed to 150mm dia drain pipes including packing under, & haunching against the sides of pipes after they are laid & tested; in PCC (1:4:8), type D1 complete all as specified and as directed by Engr-in-Charge.
M&L Concrete bed to 200mm dia drain pipes including packing under, & haunching against the sides of pipes after they are laid & tested; in PCC (1:4:8), type D1 complete all as specified and as directed by Engr-in-Charge.
S&F salt glazed stone ware drain pipes of 100mm bore, grade `A', ISI marked, laid to slope in trenches, jointed in CM (1:1) and tested, complete all as specified and as directed by Engr-in-Charge.
S&F salt glazed stone ware drain pipes of 150mm bore, grade `A', ISI marked, laid to slope in trenches, jointed in CM (1:1) and tested, complete all as specified and as directed by Engr-in-Charge.
S&F salt glazed stone ware drain pipes of 200 mm bore, grade `A', ISI marked, laid to slope in trenches, jointed in CM (1:1) and tested, complete all as specified and as directed by Engr-in-Charge.
Dismantling of cast iron drain pipes of 100 mm bore jointed in CM and taking out of the trenches/ wall, complete all as specified and as directed by Engr-in-Charge.
Dismantling of cast iron drain pipes of 75 mm bore jointed in CM and taking out of the trenches/ wall, complete all as specified and as directed by Engr-in-Charge.
S&F 75mm bore cast iron sand cast soil, waste & vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors, complete all as specified and as directed by Engr-in-Charge.
S&F 100mm bore cast iron Sand cast soil, waste & vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors, complete all as specified and as directed by Engr-in-Charge.
S&F 75mm bore cast iron sand cast soil, waste & vent pipes, in any length with or without ears with cement joints, fixed to walls, complete all as specified and as directed by Engr-in-Charge.
S&F 100mm bore cast iron Sand cast soil, waste & vent pipes, in any length with or without ears with cement joints, fixed to walls, complete all as specified and as directed by Engr-in-Charge.
S&F 75mm bore cast iron Bends (any radius), diminishing pieces or tapers (larger bore measured), including taking down old bends complete all as specified and as directed by Engr-in-Charge.
S&F 75mm bore cast iron Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches including taking down old branch pieces, complete all as specified and as directed by Engr-in-Charge.
S&F 100mm bore cast iron Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches including taking down old branch pieces, complete all as specified and as directed by Engr-in-Charge.
S&F 100mm bore cast iron cowls including taking down old cowls, complete all as specified and as directed by Engr-in-Charge.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, Type 'B', ISI marked of 110mm bore, including taking out of old pipe, , complete all as specified and as directed by Engr-in-Charge.
S&F PVC (SWR) vent cowl of 110mm bore including taking down old cowl, complete all as specified and as directed by Engr-in-Charge.
S&F SGSW gully trap square or round mouthed type 'P' of size 150 x 150 mm with CI grating including raising upto plinth protection with PCC 1:2:4 type B-1 and covered with stone slab, complete all as specified and as directed by Engr-in-Charge.
Dismantling, floor, hearth or wall tiling including CM(bedding (but not backing), removing serviceable tiles to store & rubbish off the premises, complete all as specified and as directed by Engr-in-Charge. Note: The item will be executed in patch works where ever required as per site condition for making good the demolished area /item of executed due to repair of sewer line/ manholes works only.
M/L coloured Non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of Each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm , in floors etc set jointed in neat cement slurry and pointed in white or coloured cement match over and including 15 mm thick screed bed in CM(1:6), complete all as specified and as directed by Engr-in-Charge. Note: The item will be executed in patch works where ever required as per site condition for making good the demolished area /item of executed due to repair of sewer line/ manholes works only.
M/L coloured glazed ceramic tiles 300x200x6 mm thick on wall ,set and jointed in neat cement slurry and pointed with white /coloured cement to match over and including 10 mm thick plaster in CM(1:4) , complete all as specified and as directed by Engr-in-Charge. Note: The item will be executed in patch works where ever required as per site condition for making good the demolished area /item of executed due to repair of sewer line/ manholes works only.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate in foundations, filling and mass concrete, complete all as specified and as directed by Engr-in-Charge.
Taking down cement plaster including raking out joints, hacking for key scrubbing down with water etc built in CM, complete all as specified and as directed by Engr-in-Charge.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete but excluding ashlar facings, dressed stonework and precast concrete articles.
M&L for brick work with subclass 'B' bricks Old Size, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 except bricks
M&L for rendering 15mm thick in cement mortar 1:4 on fair face of brick work or concrete surfaces using wpc , finished even and smooth, complete all as specified and as directed by Engr-in-Charge.
Demolition of PCC in ground floors and pavings not exc 15cm thickness ( below or above ground level), complete all as specified and as directed by Engr-in-Charge. Note: The item will be executed in patch works where ever required as per site condition for making good the demolished area /item of executed due to repair of sewer line/ manholes works only.
M & L for cement concrete ( 1:2:4 ) type B1 using 20 mm graded stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement, complete all as specified and as directed by Engr-in-Charge. Note : Forming fair finished channel for drain using extra cement will be measured and paid for separately.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc, complete all as specified and as directed by Engr-in-Charge.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), fascias, fins, MH covers etc. and similar works, complete all as specified and as directed by Engr-in-Charge.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for fair finished flat surfaces of concrete, complete all as specified and as directed by Engr-in-Charge.
M&L for formwork to edges of concrete flats, roofs, floors etc not exc 10cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5cm but not exc 10cm wide for fair finished surfaces, complete all as specified and as directed by Engr-in-Charge.
M&L for precast reinforced cement concrete (nominal mix) 1:2:4 type B1 using 20mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like, complete all as specified and as directed by Engr-in-Charge Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for precast RCC 1:2:4 type B1 using 20 mm graded stone aggregate for manhole cover including placing & set in CM 1:6 all as specified Including demolition of old RCC manhole covers, complete all as specified and as directed by Engr-in-Charge Note :- Reinforcement shall be measured and paid for separately.
S&F deformed or twisted MS bar 8 mm dia , cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia, complete all as specified and as directed by Engr-in-Charge.
Demolition of stone setting paving of any description or thickness laid bedded and jointed in any mortar from any position, complete all as specified and as directed by Engr-in-Charge.
M&L for 50 mm thick sandstone slab and jointed over joist ,manholes etc complete jointed in cement mortar (1:4), complete all as specified and as directed by Engr-in-Charge.
JAGDAMBA CONSTRUCTION COMPANY
J.J.ENGINEERING
Sh. Manoj Nagar
M/S JALANDRA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .