Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.9 LAccepted-AOC C 40 BHAGAT SINGH NAGAR BHIND ROAD GWALIOR MP 474005 | NA | NA | 474005 | L1 | Accepted-AOC Being a L1 bidder | |
| 2 | L2₹37.2 L+₹2.3 L (6.71%)Rejected-Finance VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | L2 | Rejected-Finance Other than
lowest
bidder | |
| 3 | L3₹38.0 L+₹3.1 L (8.90%)Rejected-Finance 640 MAIN ROAD BABINA CANTT JHANSI UP 284401 | JHANSI | JHANSI | UP | 284401 | L3 | Rejected-Finance Other than
lowest
bidder | |
| 4 | L4₹42.3 L+₹7.4 L (21.2%)Rejected-Finance | L4 | Rejected-Finance Other than
lowest
bidder | |
| 5 | L5₹43.2 L+₹8.3 L (23.9%)Rejected-Finance 763 MAIN ROAD BABINA CANTT JHANSI UP 284401 | JHANSI | JHANSI | UTTAR PRADESH | 284401 | L5 | Rejected-Finance Other than
lowest
bidder |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
28 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BABINA
GE BABINA CANTT 284401
PROVN OF CERTAIN LBW WORK UNDER AGE B/R-I AND AGE E/M AT GE BABINA
2023_MES_625329_1
8174/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE BABINA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE BABINA
₹99,800
Yes
17 Feb 2024
27 Oct 2023
30 Nov 2023
27 Oct 2023
28 Nov 2023
14 Nov 2023
Amount
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in hard/ dense soil complete all as specified and as directed.
Excavation in post holes n.exc 0.50Cum each and getting out in hard/dense soil for foundation of verticla posts complete all as specified and as directed.
Excavation in trenches not exc 1.5m wide and n. exc 1.5m in depth for foundation etc not exc 10 Sqm on plan and not exc 1.5m in depth and getting out in any type of soil including removing cable protection covers/bricks and stacking serviceable brick for re use and dispodal of unserviceable covers upto 50m distance complete all as specified and as directed. Note: (a) Excavation will be carried carefully in order to to avoide damage of existing cables and cable protection. (b) The excavation work will be carried out in short lengths for locating fault in under ground cables at different location.
M&L returning filling in including spreading levelling, watering and well ramming in layers n.exc. 25mm in any type of soil complete all as specified and as directed.
Removing excavated material n.exc 50 mtr and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
M&L for broken stone hardcore of gauge n.exc 63mm,deposited,spread and levelled in layers n.exc 15 Cms thick,watered and rammed to true surface complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in foundation/bed/ coping for embedding pipes etc complete all as specified and as directed.
M&L for PCC 1:3:6 type C2 using 40mm graded stone agg as in filling and mass concrete including form work complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded stone agg as in filling and mass concrete, Sub base/flooring complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for 80 mm thickness M-40 Grade , machine pressed precast concrete Inter locking paver blocks of any shape & size with grey cement and pigment conforming to IS-15658-2006 laid dry over sand cushion complete all as specified and as directed. (Sand cushion shall be measured and paid separately)
S&F steel work (tubular pipes,square/round ) as in vertical posts,rafters/purlins framed using ERW or induction butt welded including tubular pipes(medium) for supporting tubular/square pipe rafters/purlins special shaped washer etc.complete all as specified and as directed.
M&L for plates, plain, forming holes with riveted bolted or welded attachement complete all as specified and as directed.
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of approved colour, profile etc fixed to purlins with SD screws complete all as per manufacuturer instn complete all as specified and as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M & L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cm (1:6), as in raising the of hight for brick wall complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces of wall, finish even and smooth without using extra cement on conc/brick surfaces in CM 1:4, complete all as specified and as directed
M&L for preparing old decorated surfaces of wall and applying two coats cement base paint complete all as specified and as directed.
M&L for preperation of surfaces of any description,over 10cm in width or grith with two coats of synthetic enamal over a coat of red oxide primer complete all as specified and as directed.
M & L for surface PVC conduit point wiring for one light point controlled by one switch complete with PVC insulated and unsheathed flame retardant low smoke and halogen ( FRLSH ) cable of 2.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 20 mm dia, clip, with MS terminal boxes (not less than 1.6 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including common earth dolly with 3 mm thick plastic laminated sheet top cover of approved make and colour including 2.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete including cutting necessary chases on wall / ceiling surfaces for drawing of conduit & cables as required and making good disturbed surfaces of walls with CM 1:3:6 and matching with the existing surfaces including colour washing all as specified and as directed .
S&F MCB single pole and neutral 40/63 Amp 240 V ,10KA , 'C' series, connected with copper lugs complete all as specified and as directed.
S&F Rigid non-metallic PVC conduit not less than 25mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, locknuts, saddles, pipe hooks etc. complete all as specified and as directed.
S&F MCB single pole 6 to 32Amps 240 V,10KA, 'B' series, connected with copper lugs complete all as specified and as directed.
S&F MCCB 4 pole, 415V, AC , 3 phase, 50 HZ, breaking capacity 16 KA with fixed thermal and fixed magnetic setting of capacity 125 Amps 'C' series complete all as specified and as directed.
M&L for sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLS, 1100 Volts grade cable drawn into conduit (Existing / new) including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 6 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete all as specified and as directed Note:- (a) Two runs of 6 sqmm cable and one run of 6 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) New conduit and conduit accossories shall be measured separately.
S&F TPN DB-DPX 125 MCCB DBs 4 way single door with provision for DPX 125 MCCB and as incomer and SP/TP MCBs as outgoing Nos of modules DPX 125+12, including 125 Amp MCCB complete all as specified and directed.
S & F sheet metal enclosure double door concealed suitable for distribution boards when MCBs to be used having 100 Amp rated bus bar 8 ways 240V including taking down complete all as specified and as directed.
S&F storage type water heater (Geyser),5 star BEE rating, 230 Volt AC, 25 Ltrs capacity comprising Stainless steel inner tank,suitable heatng element, thermostate with adjustable temperature setting , indication lamps provision for inlet outlet and air vent connections & NRV,inclucluding all fixing arrangement such as faster, bolts, nuts & washers etc complete including making good disturbed wall surfaces matching with the existing surfaces and finishing all as specified and as directed by Engr-in-charge.
S&F PVC connection 15 mm size, heavy duty with brass nuts, 450 mm long complete all as specified and as directed.
S&F stop valves, cast copper alloy, srewed down , high pressure, with cruntch or butter fly handle, screwed both ends for iron pipe or for unions and fixed of size 15 mm dia complete all as specified and as directed.
S&F Bib taps, cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe and fixed of size 15 mm dia complete all as specified and as directed.
Supply and fixing galvanised mild steel water tubing of 15 mm dia bore medium grade ISI marked with and incl all fittings like bends, elbow, Tee, reducer sockets & union etc laid in trenches, under floor or fixed to walls / ceilings complete all as specified and as directed.
S&F MCB protected power socket unit with sheet steel enclosure include power socket , mini MCB SP 20 A ,220V,50 Hz complete all as specified and directed
Supplying and laying un-reinforced precast concrete cable cover, class LV type 1 flat size 250x150x40mm peak, laid perpendicular to the axis of cable in trenches complete all as specified and as directed.
Supply and lay river bed sand free from sharp materialsa for Sand cushioning for cables 8 cm below the cable and 15 cm above the cable all as specified and directed .
S&F factory made sheet metal enclosure of thickness 2mm suitable for fixing of MCCB 4 with fixing arrangements including supply and fix MCCB, 415V, AC , 3 phase, 50 HZ, breaking capacity 16 KA with fixed thermal and fixed magnetic setting of capacity 63 Amps 'C' series complete all as specified and as directed.
Supply,laying connecting and testing of cable XLPE insulated,screened,PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 V grade with multi stranded aluminium conductor of size 50 sqmm 3.5 core as per IS 7092 Pt-I complete all as specified and as directed.
Supply,laying connecting and testing of cable XLPE insulated,screened,PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 V grade with multi stranded aluminium conductor of size 25 sqmm 3.5 core as per IS 7092 Pt-I complete all as specified and as directed.
Supply,laying connecting and testing of cable XLPE insulated,screened,PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 V grade with multi stranded aluminium conductor of size 16 sqmm 4 core as per IS 7092 Pt-I complete all as specified and as directed.
Supply and laying GI pipe 50mm bore "LIGHT GRADE" in trenches, under floors, roads, along poles for protection of cables, including sealing ends complete all as specified and as directed.
S&F & testing commissioning of outdoor type 3.15 mm thick bus bar panel pedestal type weather proof CPRI approved MS cubical panel board outdoor type of size 110 cm x 80 cm x 40 cm, 4 Nos of bus bar of 200 Amp capacity & MCCB 160. Amp capacity 4 pole (Ics = Icu = 100%) including one coat of red oxide and two coat of enamel paint powder coated, mounted on channels and PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed. Make: Shalabh/ Universal Switch gear/Mclayers
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick weithing not less than 17.5 Kg buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 2009 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
M/S Kharya Associates
M/s Ravi Traders
m/s gupta trading
Ms Vinay constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .