Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71.1 LAccepted-AOC PEMASAR ROAD WARD NO 04 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹75.5 L+₹2.4 L (3.29%)Rejected-Finance | L2 | Rejected-Finance High Rate Quoted | |
| 3 | L3₹76.5 L+₹3.4 L (4.64%)Rejected-Finance H NO 02 SAGAR ROAD OPPO MKD GIRLS SCHOOL TILAK NAGAR BIKANER 334001 | BIKANER | BIKANER | RAJASTHAN | 334001 | L3 | Rejected-Finance High Rate Quoted | |
| 4 | L4₹79.0 L+₹5.8 L (7.96%)Rejected-Finance H NO 327 KRISHNA ENCLAVE HIMMATGARH PO DHAKOLI ZIRAKPUR 140603 | S A S NAGAR | PUNJAB | 140603 | L4 | Rejected-Finance High Rate Quoted | |
| 5 | L5₹80.3 L+₹7.2 L (9.79%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L5 | Rejected-Finance High Rate Quoted |
Tender Value
₹88 L
EMD Value
₹1.6 L
Closing Date
26 Feb 2024, 6:00 pmClosed
Col Shery Goel, CWE Bikaner
HQ CWE Bikaner, Bikaner Mil Stn
Spl repair to Bldg No. P-168 and P-170 (OR Lines) including rewiring (aluminium to copper) at Bikaner Mil Stn under GE (N) Bikaner
2023_MES_628385_3
CA No CWE BKN-Token No. 46/2023-2024
Open Tender
Civil Works
Item Rate
270 days
GE N BIKANER
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Yes
GE (N) Bikaner
₹1.6 L
Yes
19 Mar 2024
9 Feb 2024
1 Mar 2024
9 Feb 2024
26 Feb 2024
19 Feb 2024
9 Feb 2024 - 12 Feb 2024
Amount
Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thick (below or above ground level) including floor tiles of any description complete all as specified & as directed.
Demolition of reinforced cement concrete of any description and in any position (reinforcement cut as required to facilitate demolition) not otherwise specifically provided for in this Schedule, complete all as specified & as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Taking down cement plaster or cement lime plaster, terrazo etc on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and as directed.
Taking down shutters (including fittings & fixtures) of any description exc 1 Sqm and not exc. 2 Sqm each, complete all as specified and as directed.
Taking down shutters (including fittings & fixtures) of any description exc 1 Sqm and not exc. 2 Sqm each, and refixing in the same position after necessary easing, repair, adjustment complete all as specified and as directed.
Taking down chowkat or frame with shutters (including fittings & fixtures) area not exc 1.5 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.
Taking down chowkat or frame with shutters (including fittings & fixtures) area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.
M&L for anti-termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified & as directed.
M&L for anti-termite treatment to the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified & as directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for PCC 1:3:6 type C0 (using 12.5mm graded crushed stone aggregate) as in filling up chowkat/frame hollows and similar works complete all as specified and as directed.
M&L for reinforced cement concrete M-25 grade (Design mix) using 20mm graded crushed stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like complete all as specified & as directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
Supply only integral liquid water proofing compound (ISI marked) complete all as specified & as directed.
M&L for brick work with old size Fly Ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work with old size Fly Ash bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified & as directed.
Supply and fixing factory made 35 mm thick plain framed, paneled shutter (Two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces, size of rail and styles as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated using second class Hard Wood rail and styles, fixed to chowkat, complete all as specified & as directed.
Supply and fixing factory made 35mm thick glazed and skeleton shutters made of second class hard wood, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in clause 8.24(a) of Section 8 in SSR Part-I, kiln seasoned and chemically pressure treated, fixed to chowkat, complete all as specified & as directed.
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour single piece extruded PVC profile reinforced with MS square tube, fixing in opening as per specifications complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with plain colour single piece extruded PVC profile ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour single piece extruded PVC profile for top rail lock rail bottom rail on either side and as gap insert for Top rail and bottom rail paneling of plain colour PVC sheet to fitted on the MS frame welded/sealed to the styles and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified and as directed..
M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed.
Forming jambs, etc., in cement mortar (1:4) to openings (to foregoing item), with stone including cutting, toothings and properly bonding into old work, including facing and pointing (if necessary) to match existing work, complete all as specified and directed.
S&F butt hinges of size 100mm medium weight, cold rolled mild steel (ISI marked) including welding to angle iron frame where required complete all as specified and as directed.
S&F 100mm long butt hinges stainless steel, ISI Marked complete all as specified and as directed.
S&F 150 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified.
S&F 100mm size aluminium handle, cast type, powder coated, complete all as specified & as directed.
S&F 300mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S&F in repair mild steel 300mm ordinary rat tail rod pattern spring including roller and roller plate, complete all as specified & as directed.
Supply and fixing Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Supply and fixing Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, fixed in repairs, complete all as specified and as directed.
S&F in repair stainless steel curtain/drapery rod of 25mm dia (in lengths as directed) & including wooden finish decorative finial at both ends and pair of stainless steel brackets fixed at both ends with PVC rawl plug & steel screws on walls/beam, including PVC curtain rings of matching colour @ 10cm C/C complete all as specified & as directed. Note : The cost of bracket and knobs is deemed to be included in the quoted rates. Nothing extra shall be paid on this account.
S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, framed signed boards, walk ways, railings, framework of water tanks and similar work including welding conforming to Grade E-165 (Fe 290), complete all as specified & as directed.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 including necessary welding etc. and fixed in position complete all as specified & as directed.
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
S&F factory made pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, made out of mild steel sheet of 1.25 mm thickness, complete as specified & as directed.
S&F factory made pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, made out of mild steel sheet of 1.25 mm thickness, complete as specified & as directed.
S&F factory fabricated pressed steel frame/box windows, ventilators with glazed and fly proof shutters provided to size and dimensions as specified & shown on drawing No. BTD-888R Sheet No. 1/5 to 5/5 & BTD-889 Sheet No. 1/4 to 4/4 with & including MS grill, MS fillets, pintol hinges, tower bolts, MS handles, peg stays, MS lugs, locking arrangement, dash through bolt where required, etc complete all as specified & as directed. Notes : (i) PCC for filling in frames, glass, wire gauge and painting shall be measured & paid for separately under respective items. Provision of all other items as shown & specified on drawings shall deemed to be included in quoted rate of this item. (ii) The quoted rate shall deemed to include provision of cutting holes of suitable depth in walls for inserting lugs etc and making good dismantled portion in PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate and CM (1:3).
Dismantling of roof tiles/brick tiles or terracing tiles single layer on roofs, complete all as specified and as directed. Note : Tiles shall be dismantled carefully and stacked properly including segregating the serviceable & unserviceable tiles as directed. Serviceable tiles shall be reused under the respective item of this Schedule.
Demolition of lime concrete of any description over roof, complete all as specified and as directed.
M&L for 10mm thick plaster (screed bed) over roof slab in CM 1:4, mixed with integral liquid water proofing compound as per manufacturer’s instructions, finished even & smooth without using extra cement, complete all as specified and as directed. Note : Supply only integral liquid water proofing compound shall be measured and paid for separately.
M&L for cleaning of all loose dirt and dust from roof and priming the surface with one coat of cold applied bituminous primer @ 0.40 litre/sqm and provide a layer of APP based polymeric membrane minimum weighing 3 Kg/sqm and minimum 3mm thick, reinforced with polyester non woven fabric (weighing not less than 150 gms/sqm) laid on primed surface complete all as described in Para 11.44.5 of SSR Part-I, complete all as specified and as directed. Note : The net area of water proofing treatment shall be measured without any extra allowance for laps.
M&L for Lime concrete terracing as specified in roof complete all as specified & as directed.
M&L for 40mm thick brick tiles, joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement, laid on roof over & including 15mm thick screed bed in cement & sand mortar 1:6, complete all as specified & as directed.
All as per serial item No. 47.00 here-in-before but except brick tiles complete all as specified & as directed. Note : Old serviceable brick tiles retrieved from serial item No 42.00 here-in-before shall be used under this item.
M&L for 25mm thick PCC (1:2:4) type B0 using 12.5mm graded crushed stone aggregate as in flooring, leveling course, etc, surface finished fair and even, complete all as specified and as directed.
M&L for machine cut Kota stone slab flooring 18 to 20mm thick laid over & including screed bed or bedding layer of 20mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed.
M&L for machine cut Kota stone slab 18 to 20mm thick on vertical surfaces such as dado, skirting etc. laid over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed.
M&L for 18 to 20mm thick Granite (of any type) machine cut slab of approved shade (table rubbed and polished) with true & uniform joints as in steps, jambs, pillars, window cills, cooking platforms & like and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over & including 15mm thick screed bed (bedding layer) in CM 1:4 with cement slurry @ 3 Kg/Sqm complete all as specified & as directed. Note : The exposed edges of granite stone slab shall be made full round & polished to mirror finish and rate quoted shall deemed to include this provision.
M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for non skid ceramic tiles (coloured) 7 to 8mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for glazed ceramic tiles (coloured) 7mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm (i.e 450mm x 300mm or as directed), on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.
M&L for joint free non skid ceramic tiles (coloured) 7 to 8mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished even and smooth without using extra cement complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid with an outward slope of 1:30 in alternative bays not exceeding 4 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
M&L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls in Sunken portion, mixed with integral liquid water proofing compound as per manufacturer’s instructions, finished even & smooth without using extra cement complete all as specified. Note : Supply only integral liquid water proofing compound shall be measured and paid for separately.
M&L for removal of loose concrete and cleaning the surfaces and filling the cracks with Polymer modified mortar using Dr Fixit Pidicrete URP or other equivalent product as approved by GE and thereafter applying two coats of Dr Fixit Bathseal WPC or other equivalent product as approved by GE in Sunken areas complete all as per manufacturer’s instructions, complete all as specified & directed. Note : Where contractor desire to use equivalent product of Dr Fixit Pidicrete URP and Dr Fixit Bathseal WPC, he shall submit the technical literature of equivalent products to establish the equivalency of products to the entire satisfaction of GE and both products shall be of same manufacturer as approved by the GE.
M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified.
M&L for 15mm thick rendering in two layer on fair faces of brick masonry or concrete surfaces of walls consisting of 1st layer of 10mm thick plaster in CM 1:4 and 2nd layer (setting coat or top layer) of 5 mm thick plaster in CM 1:4, 2nd layer mixed with integral liquid water proofing compound as per manufacturer’s instructions, finished fair & even, complete, all as specified and directed. Note : - Supply only integral liquid water proofing compound shall be measured and paid for separately.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, mixed with integral liquid water proofing compound as per manufacturer’s instructions, finished even & smooth without using extra cement, complete all as specified and directed. Note : Supply only integral liquid water proofing compound shall be measured and paid for separately.
M&L for rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified.
M&L for preparation of newly plastered / unplastered surfaces of ceilings & applying three coats of white wash complete all as specified.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 3mm thick white wall care putty complete all as specified & as directed.
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 3mm thick white wall care putty on walls complete all as specified & as directed.
M&L for preparation of newly plastered surfaces of wall & applying two coats of weather proof acrylic emulsion paint (exterior grade) of approved shade/tint over a coat primer complete all as specified & as directed.
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces of walls and applying two coats of weather proof acrylic emulsion paint (exterior grade) of approved shade/tint over a coat of primer complete all as specified & as directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces, complete all as specified & as directed.
S&F 4mm thick figured glass pin head type and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces, complete all as specified & as directed.
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint all as specified & as directed.
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified & as directed.
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint all as specified & as directed.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified & as directed.
Dismantling carefully and taking up or down existing unserviceable/serviceable steel water tubing and connections of 15mm bore complete all as specified and as directed.
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings, fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
Fixing/Laying only, jointing and testing old serviceable galvanized steel water tubing medium grade of 15mm bore obtained serviceable vide serial item No. 74.00 here-in-before including cleaning the pipe from inside & outside properly including rust & mud removal, with & including new fittings and fixed to walls and ceilings or laid in floors in new or old position complete all as specified and as directed. Note : The quoted rate shall deemed to include new GI fittings (ISI marked). Old fittings shall not be used.
Dismantling carefully and taking up or down existing unserviceable/serviceable steel water tubing and connections of 20mm bore complete all as specified and as directed.
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings, fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
Fixing/Laying only, jointing and testing old serviceable galvanized steel water tubing medium grade of 20mm bore obtained serviceable vide serial item No. 77.00 here-in-before including cleaning the pipe from inside & outside properly including rust & mud removal, with & including new fittings and fixed to walls and ceilings or laid in floors in new or old position complete all as specified and as directed. Note : The quoted rate shall deemed to include new GI fittings (ISI marked). Old fittings shall not be used.
Dismantling carefully and taking up or down existing unserviceable/serviceable steel water tubing and connections of 25mm bore complete all as specified and as directed.
M&L for galvanized steel water tubing medium grade of 25mm bore with & including all fittings, fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
Fixing/Laying only, jointing and testing old serviceable galvanized steel water tubing medium grade of 25mm bore obtained serviceable vide serial item No. 80.00 here-in-before including cleaning the pipe from inside & outside properly including rust & mud removal, with & including new fittings and fixed to walls and ceilings or laid in floors in new or old position complete all as specified and as directed. Note : The quoted rate shall deemed to include new GI fittings (ISI marked). Old fittings shall not be used.
Dismantling carefully and taking up or down existing unserviceable/serviceable steel water tubing and connections of 40mm bore complete all as specified and as directed.
M&L for galvanized steel water tubing medium grade of 40mm bore with & including all fittings, fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
Fixing/Laying only, jointing and testing old serviceable galvanized steel water tubing medium grade of 40mm bore obtained serviceable vide serial item No. 83.00 here-in-before including cleaning the pipe from inside & outside properly including rust & mud removal, with & including new fittings and fixed to walls and ceilings or laid in floors in new or old position complete all as specified and as directed. Note : The quoted rate shall deemed to include new GI fittings (ISI marked). Old fittings shall not be used.
Hacking out old broken glass any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips complete all as specified and as directed.
Disconnecting & taking down the existing unserviceable water tank and Supply and fixing 1000 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed.
S&F in repairs Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe 20mm bore (minimum weight 210 gms) complete all as specified and as directed.
S&F in repairs vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, ‘P’ or ‘S’ trap, including connection to trap and flushing pipe, antisyphonage pipe etc, complete all as specified and as directed.
S&F in repairs PVC valveless symphonic action type low level flushing cistern (ISI marked) of 10 litre capacity including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified & as directed.
S&F in repairs vitreous china wash hand basin, white, flat back of size 550mm x 400mm with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified & as directed.
S&F in repairs PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified & as directed.
S&F in repairs 15 mm bore bib tap, cast copper alloy, chromium plated, long body, fancy type with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & as directed. Make :- Cat Part No 9208 of make – Prayag or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs 15mm bore two way Angle stop valve, fancy type with long shank and cup of cast copper alloy chromium plated, screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union complete all as specified & as directed.
S&F in repairs 15mm bore Angle stop valve, fancy type with long shank and cup of cast copper alloy chromium plated, screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union complete all as specified & as directed.
S&F in repairs 20mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete all as specified & directed.
S&F in repairs 25mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete all as specified & directed.
S&F in repairs 40mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete all as specified & directed.
S&F in repairs 50mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete all as specified & directed.
S&F in repairs brass chromium plated shower rose 125mm size with shower arm including fixing to steel pipe of 15mm bore or union complete all as specified and as directed.
S&F in repairs tubular towel rail, brass chromium plated, 20mm dia, ‘D’ type, 60cm long between flanges, fixed to PVC rawl plugs with chromium plated brass screws, complete all as specified and as directed.
S&F in repairs soap dish holder brass chromium plated fixed on wall with PVC rawl plug & cadmium plated brass screws complete all as specified & as directed. Make :- Cat Part No BA-45 of make – Prayag or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs stainless steel Peg Set of Six of standard size (not less than 300mm long) fixed to wall with two rawl plugs and chromium plated brass screws complete all as specified & as directed. Make :- Cat Part No BEA-30 of make – Prayag or equivalent in makes mentioned in Appendix 'B' here-in-after.
Dismantling 75/100mm bore cast iron, sand cast, soil, waste & vent pipe (ISI marked), in any length with or without ears fixed with cement joints, laid in trenches or floors and walls complete all as specified and as directed.
Supply and fixing 100mm bore cast iron, sand cast, soil, waste & vent pipe (ISI marked), in any length with or without ears fixed with cement joints, laid in trenches or floors, complete all as specified and as directed.
All as per serial item No. 106.00 here-in-before but except pipes complete all as specified and directed.
Supply and fixing 75mm bore cast iron, sand cast, soil, waste & vent pipe (ISI marked), in any length with or without ears fixed with cement joints, laid in trenches or floors, complete all as specified and as directed.
Supply and fixing 75mm bore cast iron, sand cast, soil, waste & vent pipe (ISI marked), in any length with or without ears fixed with cement joints, laid in trenches or floors, fixed in repairs, complete all as specified and as directed.
Supply and fixing 75mm bore cast iron, sand cast, soil, waste & vent pipe (ISI marked), in any length with or without ears fixed with cement joints, fixed to walls, fixed in repairs, complete all as specified and as directed.
All as per serial item No. 110.00 here-in-before but except pipes complete all as specified and directed.
S&F stack clamp made out of MS flat 50mm x 5mm and 16 mm dia round iron stays, including bolts & nuts, securing ends of stays to walls or roof for 100mm bore pipe including two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete all as specified & as directed.
S&F stack clamp made out of MS flat 50mm x 5mm and 16 mm dia round iron stays, including bolts & nuts, securing ends of stays to walls or roof for 75mm bore pipe including two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete all as specified & as directed.
S&F stack clamp made out of MS flat 50mm x 5mm and 16 mm dia round iron stays, including bolts & nuts, securing ends of stays to walls or roof for 50mm bore pipe including two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete all as specified & as directed.
S&F in repairs 100mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door complete all as specified & as directed.
S&F in repairs 100mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) without oval access door complete all as specified & as directed.
S&F in repairs 75mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door complete all as specified & as directed.
S&F in repairs 75mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) without oval access door complete all as specified & as directed.
S&F in repairs 100mm bore cast iron TEE, diminishing pieces or tapers (larger bore measured) with oval access door complete all as specified & as directed.
S&F in repairs 100mm bore cast iron bends (any radius) with duck's foot or heel rest complete all as specified & as directed.
S&F in repairs 100mm bore cast iron sanitary connection sockets in fit WC out let complete all as specified & as directed.
S&F in repairs 100mm bore cast iron branch piece, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified & as directed.
S&F in repairs 75mm bore cast iron branch piece, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified & as directed.
Supply and fixing cast iron vent cowl for 100mm bore CI pipe complete all as specified.
M&L for extra over cast iron pipe & fitting 100mm bore providing lead joints in lieu of cement joints complete all as specified and as directed.
M&L for extra over cast iron pipe & fitting 75mm bore providing lead joints in lieu of cement joints complete all as specified and as directed.
S&F in repairs cast iron floor trap of 100 mm bore, with grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4), complete all as specified & as directed.
M&L for cutting holes in brick walls in cement mortar exc half brick but not exc one brick for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required compete all as specified and directed.
M&L for 150mm bore reinforced concrete pipe, class NP2, laid and jointed complete with collars, laid and jointed on concrete bed complete including testing, after demolition and breaking up drain pipes set in cement mortar complete all as specified & as directed. Note :- Excavation & earthwork shall be measured and paid separately.
M&L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate in bedding to SGSW drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipe complete all as specified and as directed.
Removing building materials etc. (other than spoil payable under relevant items removal) to a distance of 5.00 Km or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and as directed.
Repairs crumple joints/ constructions joints in any position of roofs/ slab / beam of 20mm thick filling with pre formed bituminous filler materials like shailtex board etc complete inserted in crumple joints horizontal, vertical or slopping to required depth & top 30mm primed & sealed with sealing compound grade 'A' complete all as specified and as directed.
Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/batten/casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, light fittings, top sheet covers, fan regulators, wooden boxes, MS sunken boxes, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
M&L for Modular point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new modular metal flush boxes of requisite module concealed in wall for mounting fittings like modular switches, sockets, regulators etc with and including modular cover plates with frame of requisite module, complete all as specified and as directed. Notes : (i) Cost of cutting/leaving forming chases for conduits, sinking for modular metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed to include for modular metal flush boxes of requisite module and modular cover plates with frame of requisite module of colour as approved by GE.
All as per serial item No. 134.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches complete all as specified and directed.
All as per serial item No. 134.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board complete all as specified and directed.
All as per serial item No. 134.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed.
All as per serial item No. 134.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed.
S&F Modular switch 1 way 6A, 1 module, complete all as specified and as directed.
S&F Modular switch, 1 way 16 Amp, 1 module, complete all as specified and as directed.
S&F Modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and as directed.
S&F Modular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified and as directed.
S&F ceiling rose, PVC/Polycarbonate insulated body, 65mmx50mm with three terminals, ISI marked, complete all as specified and as directed.
S&F lamp holder, PVC/Polycarbonate insulated body with back plate suitable for conduit/casing caping fittings, ISI marked, complete all as specified and as directed.
S&F 9 Watt LED Bulb (Non-dimmable) of Standard / Universal size, Base - B22, Power Factor > 0.90, Lamp Efficiency > 80%,, Color Temperature - 3000 K, Lumen output - 900 lm, Colour Rendering Index (CRI) > 70, Warm white (WW) / Cool Day Light (CDL), 230 V, 50 Hz AC, ISI marked, complete all as specified and as directed.
S&F Modular Fan step regulator, 120 Watt - 2 module, electronic fan regulator five step complete all as specified and as directed.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 5 Watt 240 Volt, 50 Hz AC, ISI Marked decorative type with driver holder and LED lamp, correlated colour temperature shall be minimum 6500 degree Kelvin, including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F motion sensor (Standalone Controls) movement detector with build in switch. Functioning of switch off the in room or area when it is vacated and switch any load upto 6 Amp and control an area of around 20 sqm for small movement (e.g desk work) and around 50 sqm for large movement (e.g walking). Detection angle 360 degree having 3 adjustable on board knobs (e.g off time, light sensitivity & motion sensitivity) Mercury free, Toxic heavy metal free, environment friendly complete all as specified and directed.
M&L for motion sensor point wiring for light/fan point with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated complete all as specified and as directed. Notes : (i) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
Taking down of serviceable and refixing after LED tube light fitting, 1x20 Watt, 230 Volts, basic all purpose surface and wall mounted LED batten type with driver & polycarbonate housing including tube rod and all accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed.
S&F LED tube light fitting, 1x20 Watt, 230 Volts, basic all purpose surface and wall mounted LED batten type with driver & polycarbonate housing including tube rod and all accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed.
S&F bulk head energy efficient LED light fitting, 1x10 Watt, 230 Volts, surface mounted, comprising of high brightness LEDs, IP-65 protection, with & including all standard accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, fixed as in repair complete all as specified and as directed.
Supply and Fixing Light Emitting Diode (LED) based street/ security light fitting, 35 Watt with & including LED lamp, housing made up of LM6 pressure die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, minimum system efficiency of more than 100 lumens per watt and a minimum system lumen output of not less than 3000 lumens, correlated colour temperature shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-65 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, frequency 50-60Hz, potted type for humming free operation, driver shall withstand upto 400 V for 08 hours, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 15%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA /polycarbonate /toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multi stranded copper conductor cable of 1100 Volt grade (ISI marked), fixed in repairs, complete all as specified and as directed.
NOTES FOR LED LIGHT FITTINGS : (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced on site free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
Supply and fixing mounting bracket (suitable for fixing/holding street/security light fittings) made of 40mm bore GI pipe ‘light grade’ not less than 1.50m long, bent to shape at required angle, fixed to Pole/wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, matching with section of Pole/suitable for wall, fixed in repairs complete all as specified and as directed.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 230 Volt, 10 kA, ‘C’ Curve, fixed in repairs, complete all as specified and as directed.
S&F sheet metal enclosure for distribution boards flushed in wall, double door type, 415 Volts with 200 Amps rated bus bar, load line DB fitted with bus bar neutral links blank plates, TPN, vertical load line, 4 way, suitable for 3 Pole / 4 Pole ‘A’ frame MCCB, fitted with accessories, complete all as specified and as directed including taking down old existing unserviceable DB with fixtures of any type & capacity. Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
S&F sheet metal enclosure, double door type, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 8 way, 240 Volts, fixed in repairs, complete all as specified and as directed.
S&F sheet metal enclosure, double door type, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 4 way, 240 Volts, fixed in repairs, complete all as specified and as directed.
S&F MCB, 6 to 32 Amps, Single Pole, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
S&F MCB, 6 to 32 Amps, SPN, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
S&F MCCB 4 Pole 100 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades & refixing after necessary repair such as winding of motor, replacement of capacitor & ball bearing of ceiling fan of any make, any sweep, keeping side to store in safe custody for painting of ceiling fans complete, insitu with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and directed.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades & refixing after necessary repair such as winding of motor, replacement of capacitor & ball bearing of exhaust fan of any make, any sweep, keeping side to store in safe custody for painting of exhaust fans complete, insitu with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40 mm thick RCC pit cover, etc including dismantling & taking out old existing unserviceable earthing complete all as specified & as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with Four runs of 10 sqmm (nominal area) size main cable & Two run of 10 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 32mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 04 runs of 10 sqmm size main cable, 02 run of 10 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 35 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed. Notes :-(i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm confirming to IS -5820 complete all as specified and as directed.
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings, laid in trenches/under road/drain including taking down old unserviceable pipe with clamps complete all as specified and as directed. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for galvanized steel water tubing medium grade of 25mm bore with & including all fittings, laid in trenches/under road/drain including taking down old unserviceable pipe with clamps complete all as specified and as directed. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for galvanized steel water tubing medium grade of 40mm bore with & including all fittings, laid in trenches/under road/drain including taking down old unserviceable pipe with clamps complete all as specified and as directed. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for galvanized steel water tubing medium grade of 50mm bore with & including all fittings, laid in trenches/under road/drain including taking down old unserviceable pipe with clamps complete all as specified and as directed. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for Galvanized iron tubing, 80mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete including taking down old unserviceable pipe with clamps complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for Valve Pit of internal size 90cm x 90cm x 60cm built in brick masonry complete all as specified in Particular Specifications and as shown on drawing No. BTD-811 Sheet No. 1/2 & 2/2.
Cutting existing steel tubing for alterations or additions (Each cut measured), necessarily done in position without taking down, 20 to 50mm bore pipe complete all as specified & as directed.
RAJENDER ENTERPRISES
SHREE GURU NANAK CONSTRUCTION COMPANY
G S BUILDERS AND ENGINEERS
M/s Rohit Construction Co.
B K CONTRACTORS
Gill Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .