| 1 | 1₹34.5 LAccepted-Finance | 1 | Accepted-Finance L1 | |
| 2 | 2₹37.1 L+₹2.6 L (7.58%)Accepted-Finance | 2 | Accepted-Finance L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not Qualified as per PQC | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Qualified as per PQC |
| Sl No | Description | Qty | Unit | Cosmic Enterprises L1 | sharma construction L2 |
|---|---|---|---|---|---|
| 1.00Safe carriage of the following material from Store Centre Majhola/JE's store to work site including loading and unloading at both ends :- | |||||
| 1.01 | 33 KV CT 400/200/1A | 3 | No. | 100 ₹300 Lowest | 1,000 ₹3,000 |
| 1.02 | ST pole 11 meter long | 4 | No. | 100 ₹400 Lowest | 600 ₹2,400 |
| 1.03 | ACSR dog conductor | 250 | Meter | 40 ₹10,000 Lowest | 55 ₹13,750 |
| 1.04 | Lightening arrester | 1 | Set | 400 ₹400 | 320 ₹320 Lowest |
| 1.05 | 33 KV VCB 800A, 750 MVA | 2 | No. | 100 ₹200 Lowest | 210 ₹420 |
| 1.06 | 33 KV control panel for double transformer | 2 | No. | 200 ₹400 Lowest | 600 ₹1,200 |
| 1.07 | 33 KV PT outdoor | 3 | No. | 100 ₹300 Lowest | 700 ₹2,100 |
| 1.08 | 33 KV post insulator | 6 | No. | 100 ₹600 Lowest | 850 ₹5,100 |
| 1.09 | CT 200/100/1A | 9 | No. | 100 ₹900 Lowest | 1,030 ₹9,270 |
Tender Value
₹32.4 L
EMD Value
₹33,000
Closing Date
14 Aug 2025, 12:00 pmClosed
SE EDC-I MBD
MORADABAD
Work of installation of 33 kv VCB, CT, panel and others at substation kanth, construction of firewalls, installation of WTI, OTI, Vacuum interupter, relays etc. under EDDKanth Moradabad in business plan 2024 25.
2025_PVVNL_1054406_2
07/2025-26/EDCIM
Open Tender
Electrical Works
Lump-sum
90 days
MORADABAD
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
Yes
SE EDC-I MBD
₹33,000
Yes
19 Aug 2025
8 Aug 2025
14 Aug 2025
8 Aug 2025
14 Aug 2025
8 Aug 2025
Amount
Safe carriage of the following material from Store Centre Majhola/JE's store to work site including loading and unloading at both ends :-
33 KV CT 400/200/1A
ST pole 11 meter long
ACSR dog conductor
Lightening arrester
33 KV VCB 800A, 750 MVA
33 KV control panel for double transformer
33 KV PT outdoor
33 KV post insulator
33 KV line isolator
33 KV control panel for single transformer
Line material such as Pin Insulators, Disc Insulators earthing, stay set etc.
For 33 KV Line, Four pole structure:- Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole), providing and laying of stone pad (300x300x75mm.) in the bottom of the pit. Erection of support (pole) complete with fixing of cross basing angle and all other accessories by providing stone pad and nuts & bolts etc. as per RESPO Norms.
Grouting of Poles Single line support :- Grouting of support in CC 1:4:6 (cement, sand and 40 mm. brick ballast) Grouting will be done in the block of size 45cm x 45cm x 1/6th of full length of the support upto ground level as per RESPO Norms.
Grouting of stay rods (20x1800mm.) including all works of excavation, cement concrete in size of (0.60x0.60x0.30)M in the ratio of 1:4:6 (cement, sand and 40 mm. brick ballast) including back filling of soil and proper ramming etc.
Fixing, tightening and nozelling of stay wire with stay rod and stay insulators with the pole of required tension by providing stay clamps, nuts, bolts etc.
Earthing of support with MS Earth Rod of (20x2500)mm. long including excavation of pit and driving MS Rod 3.0M apart from support and 0.5M below the ground level and connecting below the earth electrodes with the help of G.I. Wire No.6 SWG tightening with nuts and bolts.
Laying of Dog conductor at substation yard kanth as per RESPO Norms.
Construction of steel structure for C.T. by providing all type of material, labour and T&P. Complete work as per RESPO norms.
Installation of CT 400/200/1A on structure, making proper connection as per RESPO norms.
Installation of CT 200/100/1A on structure, making proper connection as per RESPO norms.
Construction of Main bus bar at kanth substation yard by providing all type of material, labour and T&P. Complete work as per RESPO norms.
Construction of steel structure for L.A. by providing all type of material, labour and T&P. Complete work as per RESPO norms.
Fixing of L.A.on structure, making connection complete work as per RESPO norms.
Construction of steel structure for 33 KV VCB by providing all type of material, labour and T&P. Complete work as per RESPO norms.
Construction of plinth and foundation for 33 KV VCB by providing all type of material, labour and T&P. Complete work as per RESPO norms.
Installation of 33 KV VCB on plinth making proper connection as per RESPO norms.
Construction of steel structure for P.T. by providing all type of material, labour and T&P. Complete work as per RESPO norms.
Construction of steel structure for 33 KV line isolator by providing all type of material, labour and T&P. Complete work as per RESPO norms.
Construction of Terminal gantry structure in kanth substation yard by providing all type of material, labour and T&P. Complete work as per RESPO norms.
Providing and laying of control cable 4x2.5 sq.mm. at kanth and sarkarakhas substation yard, making proper connection complete work as per RESPO norms.
Providing and laying of control cable 2x2.5 sq.mm. at kanth and sarkarakhas substation yard, making proper connection complete work as per RESPO norms.
Water level earthing of power transformer, control panel and structure installed at kanth substation minimum 40 foot or upto water lavel whichever is higher by proving all type of material, labour and T&P. Complete work as per RESPO norms.
Water level earthing of power transformer and VCB installed at Sarkarakhas substation minimum 40 foot or upto water lavel whichever is higher by proving all type of material, labour and T&P. Complete work as per RESPO norms.
Construction of fire wall between the power transformer installed at Dalpatpur, Bheekanpur and Kanth by proving all type of material, labour and T&P. Complete work as per RESPO norms.
Providing and replacement of W.T.I. of power transformer installed at substations under EDD-2 Moradabad and making tripping healthy after wiring.
Providing and replacement of O.T.I. of power transformer installed at substations under EDD-2 Moradabad and making tripping healthy after wiring.
Providing and replacement of 11 KV protection relay of control panel installed at different substations under EDD-2 Moradabad and making tripping healthy. Relay shoud be Aashida/C&S make approved from PVVNL.
Providing and replacement of 33 KV protection relay of control panel installed at different substations under EDD-2 Moradabad. Complete work as per RESPO Norms and making tripping healthy. Relay shoud be Aashida/C&S/L&T make approved from PVVNL.
Providing and replacement of vacuum interupter of 11 KV VCB installed at different substations under EDD-2 Moradabad. Vacuum ineterupter should be suitable as per VCB. Complete work as per RESPO Norms.
Proper installation of 33 KV control panel for double TF (main) at Kanth substation as per RESPO norms.
Proper installation of 33 KV control panel for double TF at Kanth substation as per RESPO norms.
Proper installation of 33 KV control panel for Single TF at sarkarakhas substation as per RESPO norms.
Installation of 33 KV Post isolator on structure, making proper connection as per RESPO norms.
Installation of 33 KV PT outdoor on structure, making proper connection as per RESPO norms.
Installation of 33 KV line isolator on structure, making proper connection as per RESPO norms.
Dismentaling of Old and damaged 33 KV Control panel and Carriage from work site to Store Centre Majhola including loading and unloading at both ends
Dismentaling of Old 33 KV structure installed at Kanth substation and carriage of material scrap (2000 kg) from work site to Store Centre Majhola including loading and unloading at both ends
sharma construction (BID ID -5429024)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .