| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAccepted-Finance | ₹2.8 L | L1 | Accepted-Finance Responsive / Successful |
| 2 | L2₹2.8 LAccepted-Finance | ₹2.8 L | L2 | Accepted-Finance Responsive |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Updated dates
Tender Value
₹3 L
EMD Value
₹6,000
Closing Date
16 Feb 2026, 3:00 pmClosed
Executive Engineer RSGC
Executive Engineer RSGC
Electrification of Swimming pool and allied areas at Royal Springs Golf Course, Srinagar.
2026_Tourm_300991_1
E-NIT 53 of 2025-26 Dated 20-01-2026
Open Tender
Electrical Works
50 days
RSGC srinagar
Please refer Tender documents.
2 documents required · 2 mandatory
₹550
Secretary RSGC
₹6,000
24 Feb 2026
20 Jan 2026
17 Feb 2026
20 Jan 2026
16 Feb 2026
20 Jan 2026
Supply and errection of Cast iron ornamental lamp post 900mm -1000mm. ( bollard type) with base plate ( As per Approved sample/ drawing enclosed) having provision at bottom for built in gear box fitted with PVC 4 way connector 63 amp. The bollard shall be powder coated painting confirming to Dewarka catalogue (DBL-103, 90/100 CM) /equivalent standard make as directed by engineer incharge The bollard should be CI ornamental design carvings ,engraved and embrosse over it with ant corrosive polyurethane enamel with antique finish with inbuilt 18 watt LED Lamp .Further the bollard shall be erected on prelaid foundation as pe enclosed drawing.
Providing and laying of cement concrete foundation in the ratio of 1:2:4 after digging a pit of required size with its Reinforcement as per enclosed drawing including nuts and bolts welded properly with reinforcement tar steel complete.The job includes steel shuttering and removal of excuated earth and shuttering of above ground foundation block (2.6 ft x 1 ft x 1 ft)
Supplying and laying of required/suitable size of DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (40-50 cm below ground level)for carrying out cables including excavation and refilling the trench and the surface level properly. The job includes the removal of excivated surplus earth
Providing of an Earthing using 3ft Long Gi electrode to be driven into earth pit bottom and extending through 10 swg GI wire. The Gi wire should be welded poperly with electrode and fitted with the bollard foundation bolt.
S/L , testing and commissioning of LT Power Cable , copper conductor ,XLPE Insulated,unarmoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Copper cable Havell/Paraflex/Eq. standard make as desired by the engineer incharge and making end termination with brass compression gland and copper lugs of required size. a) 4 sq.mm 4 core(un-armoured)
Providing power connection to the bollard lamp holder using 3-core ,1.5 Sq.mm twin core flexible wire from connector to holder
Supplying and fixing of 40-63 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections.of Legrand / ABB /Schneider /L&T /Simens make Bollard Ckt = 1 no. AC O/P = 2 No AC I/P = 1 No Spare = 1 No.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator)of Legrend /L&T /ABB /Simens /Schinder make a) 6 way, Double door one each for bollards for bollards and AC's
Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Wiring for AC Points with wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surfacel recessed medium class PVC conduit as required.of RR Kabels /Salzar / Finolex / Anchor make a) 2 X4 sq. mm + 1 X4 sq. mm earth wire
Supply,Installation,Testing & Commissioning of BEE-4 Star rating ≥ 1.0 Ton Inverter type Split Air Conditioner Hot and Cold Air Conditioner of Hitachai /O-General / Mitsubushie /Toshbia make .The job further includes providing and fitting of indoor unit on wall by employing suitable clamps and outdoor units on angle iron Stand for holding of out door unit fitted with nuts and bolts,laying of refrigerant copper piping upto 3 mtrs, whereever needed,insulating the copper pipeline with nitrilic foam ,topping up with refrigerant for additional length of piping etc.complete. The job also includes p/f of pvc flexible drain pipe of length 12 mts alongwith fittings.The job further encompasses carrying out repairs to walls whereever the same are cut.The job includes AMC of AC for a period of two years from date of sucessfull commissioning .
Supply,Installation,Testing & Commissioning of BEE-4 Star rating ≥ 1.5 Ton Inverter type Split Air Conditioner Hot and Cold Air Conditioner of Hitachai /O-General / Mitsubushie /Toshbia make .The job further includes providing and fitting of indoor unit on wall by employing suitable clamps and outdoor units on angle iron Stand for holding of out door unit fitted with nuts and bolts,laying of refrigerant copper piping upto 3 mtrs, whereever needed,insulating the copper pipeline with nitrilic foam ,topping up with refrigerant for additional length of piping etc.complete. The job also includes p/f of pvc flexible drain pipe of length 12 mts alongwith fittings.The job further encompasses carrying out repairs to walls whereever the same are cut.The job includes AMC of AC for a period of two years from date of sucessfull commissioning .
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
BOQ_976567.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid