Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.1 LAccepted-Finance | L1 | Accepted-Finance Accepted | |
| 2 | L2₹56.8 L+₹8.7 L (18.2%)Accepted-Finance | L2 | Accepted-Finance Accepted | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | Sparsh Enterprises L2 | SAFDAR HUSAIN CONTRACTOR L1 |
|---|---|---|---|---|---|
| 1.00For EDD Chandausi Sambhal and Babrala | |||||
| 2.00Safe carriage of the following material from Store Centre JE's store to work site including loading and unloading at both ends. | |||||
| 2.01 | 11 KV Disc fitting | 36 | Nos. | 20 ₹720 Lowest | 250 ₹9,000 |
| 2.02 | 11 KV fuse Set | 6 | Nos. | 100 ₹600 Lowest | 250 ₹1,500 |
| 2.03 | 11 KV Pin insulator (Polymeric) with pin & nut | 36 | Nos. | 10 ₹360 Lowest | 250 ₹9,000 |
| 2.04 | 11 KV Polymeric Disc Insulator T&C type 4500kg. | 36 | Nos. | 10 ₹360 Lowest | 380 ₹13,680 |
| 2.05 | 11/0.4 KV 250 KVA T/F | 63 | Nos. | 3,000 ₹1,89,000 Lowest | 3,000 ₹1,89,000 Lowest |
| 2.06 | 11/0.4 KV T/F 25 KVA | 6 | Nos. | 1,500 ₹9,000 Lowest | 2,000 ₹12,000 |
| 2.07 | ACSR WEASAL CONDUCTOR | 1,930 | Mtr | 2 ₹3,860 Lowest | 25 ₹48,250 |
| 2.08 | Earthing of pole by MS earthing rod of 20x2500mm | 1,584 | Nos. | 20 ₹31,680 Lowest | 450 ₹7,12,800 |
Tender Value
₹66.8 L
EMD Value
₹67,000
Closing Date
16 Sept 2025, 12:00 pmClosed
SE EDC Sambhal
132 KV Compound Hydel Colony Chandausi
Work of increasing capacity of distribution transformer in business Plan 2025 26 under EDD CHANDAUSI SAMBHAL AND BABRALA
2025_PVVNL_1069448_1
07/2025-26 EDC (S)
Open Tender
Electrical Works
Lump-sum
120 days
Chandausi
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
Yes
SE EDC SAMBHAL
₹67,000
Yes
22 Sept 2025
28 Aug 2025
16 Sept 2025
28 Aug 2025
16 Sept 2025
28 Aug 2025
Amount
For EDD Chandausi Sambhal and Babrala
Safe carriage of the following material from Store Centre JE's store to work site including loading and unloading at both ends.
11 KV Disc fitting
11 KV fuse Set
11 KV Pin insulator (Polymeric) with pin & nut
11 KV Polymeric Disc Insulator T&C type 4500kg.
11/0.4 KV 250 KVA T/F
11/0.4 KV T/F 25 KVA
ACSR WEASAL CONDUCTOR
Earthing of pole by MS earthing rod of 20x2500mm
L T. CABLE 1x400 SQ. MM
LT ABC (3x95+1x70+1x16) Sq. mm
LT PVC Cable 3.5x70/35 sq mm
MS angle 75x75x6x2028mm with clamp & bolt and nut (T/F base)
MS Channel (Dropper) 100x50x2028mm (for fuse set)
MS Channel 125x65x1300mm (T-off)
MS Top channel (125x65x2240mm)
PCC Poles 8.5 Mtr. Long
Stay set Complete 16x1800
Line material such as Cross-Arms, Pin Insulators, MS Channel, Disc Insulator, Stay Set, Earthing Complete, Fues Set etc.
Removing of 11/0.4 KV 10 KVA Transformer from work site including loading and stacking at a safe place, including loading and unloading at both ends (on site to store)
Removing of 11/0.4 KV 100 KVA Transformer from work site including loading and stacking at a safe place, including loading and unloading at both ends (on site to store)
Removing of 11/0.4 KV 160 KVA Transformer from work site including loading and stacking at a safe place, including loading and unloading at both ends (on site to store)
Construction of plinth for 250 KVA Transformer 2 x 2 x 1.5 M with fencing as per RESPO Norms and as per direction of Supervision Engineer (Material for plinth and fencing will be provide by the Contractor)
Installing of Healty Transformer, connection HT< of 250 KVA T/F at substation Single Pole/double poles/plinth by Healthy transformer (including connection) and loading and unloading with associated work at both ends within 70 kms.
Making of wire maseh fencing of size 2 x 2 x 1.5 mm for 250 KVA Transformer with plinth all accessories as per RESPO Norms.
Providing & Fixing of Nut Bolts & Aluminum HT/LT Lugs, etc.
Earthing of Water Lever Neutral and body with G.I. Pipe High Quality for 250 KVA Transformer as per RESPO Norms.
Earthing High Quality for 25 KVA Transformer as per RESPO Norms.
Making All HT/LT Connections and releasing of proper supply
For 11 KV Line, Single support 13/11/9/8.5 Mtr. long ST/PCC Poles :-
Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole), providing and laying of stone pad (300x300x75mm.) in the bottom of the pit. Erection of support (pole) complete with fixing of 11 KV V-Type cross-arms and all other accessories by providing stone pad, cross arms, holding clamps, f-bracket and nuts & bolts etc. as per RESPO Norms.
For 11 KV Line, Double Pole structure with 13/11/9/8.5 Mtr. long ST/PCC Poles :-
Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole). Erection of support (pole) complete work by fixing of Clamps and all other accessories. The work includes fabrication work and fixing of cross bracing sets, cutting holes complete work as per RESPO Norms.
Grouting of Poles Single line support :- Grouting of support in CC 1:4:6 (cement, sand and 40 mm. brick ballast) Grouting will be done in the block of size 45cm x 45cm x 1/6th of full length of the support upto ground level as per RESPO Norms.
Grouting of stay rods (20x1800mm.) including all works of excavation, cement concrete in size of (0.60x0.60x0.30)M in the ratio of 1:4:6 (cement, sand and 40 mm. brick ballast) including back filling of soil and proper ramming etc.
Fixing, tightening and nozelling of stay wire with stay rod and stay insulators with the pole of required tension by providing stay clamps, nuts, bolts etc.
Earthing of support with MS Earth Rod of (20x2500)mm. long including excavation of pit and driving MS Rod 3.0M apart from support and 0.5M below the ground level and connecting below the earth electrodes with the help of G.I. Wire No.6 SWG tightening with nuts and bolts.
Laying, sagging, stringing and binding of ACSR Weasel/ Dog Conductor with all other accessories on pole as per RESPO Norms.
Laying, sagging, stringing and binding of LT Cable and LT PVC Cable with all other accessories on pole as per RESPO Norms.
Providing and fixing of Danger Board with clamp, nut and bolts.
Mounting and fixing of 25 KVA transformer on double pole including making proper connections.
Providing and fixing of holding clamp for top channel TPMO and fuse set etc. with nut and bolts.
all material provided by contractor
LT Distribution box
LT Fuse Set Installed In SMC BOX For 25 KVA To 100 KVA Distribution Transformers
LT Piercing connector 95 Sq.mm
Suspension clamp with I hook
stone pad 3*3*300*75 mm
Dead end clamp with I hook
Sparsh Enterprises (BID ID -5537925)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .