Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.1 LAccepted-AOC AT DAHISADA P O DAHISADA DIST BALASORE ODISHA | BALASORE | BALASORE | ODISHA | L1 | Accepted-AOC Work order | |
| 2 | L2₹15.2 L+₹13,539.04 (0.90%)Rejected-Finance CHANDRASEKHAR MOHANG AT PROP DIST BALASORE | KENDRAPARA | ODISHA | 754223 | L2 | Rejected-Finance L2 | |
| 3 | L3₹17.4 L+₹2.3 L (15.5%)Rejected-Finance AT NUAPADA PO RADHABALLAVPUR DIST BALASORE ODISHA | NUAPADA | BALASORE | ODISHA | L3 | Rejected-Finance L3 |
Tender Value
₹16.9 L
EMD Value
₹16,924
Closing Date
21 Sept 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Officer, soro Municipality
Executive Officer, soro Municipality
Electrification Work
2026_ORULB_140546_1
SOROM_05_2026-27
Open Tender
Civil Works - Others
Percentage
90 days
Soro Municipality, Soro
Please refer to the tender document
2 documents required · 2 mandatory
₹6,000
₹16,924
Yes
27 Oct 2026
9 Sept 2026
22 Sept 2026
9 Sept 2026
21 Sept 2026
9 Sept 2026
120 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Kalyan Mandap / MPH / Open Air theatre Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R & B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work.Group C | 85 | Nos | 1,281 | ₹1,08,885 |
| 2 | Recessed wiring to secondary light point looped from primary light point with 1.5sqmm FRLS PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia HMS FRLS PVC conduit ISI marked with 1.5sqmm FRLS PVC insulated single core multistrand copper conductor for running earth including 3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer in charge.(Make of Wires- Finolex / Anchor / Polycab / HAVELLS / RR KABEL / KEI) or equivalent) (Make of Conduit-AKG / BEC / Precision / Norpak / Anchor / Kinjal or equivalent reputed make A catagory ISI marked as approved) (Make of switch/socket- Schneider(Zencelo) / legrand( Myrius-NEXT GEN) / Panasonic (vision) or equivalent) (Make of accessories- Anchor/Havells) (Make of G.I box, face plate & cover-Schneider(Zencelo) / legrand( Myrius-NEXT GEN) / Panasonic (vision) or equivalent reputed make & model A catagory ISI marked as approved). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. Average Length: 3 mtr. | 185 | Nos | 447 | ₹82,695 |
| 3 | Recessed wiring to ceiling fan point with 1.5sqmm FRLS PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia HMS FRLS PVC conduit ISI marked with 6Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with 1.5sqmm FRLS PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of Wires- Finolex / Anchor / Polycab / HAVELLS / RR KABEL / KEI) or equivalent) (Make of Conduit-AKG / BEC / Precision / Norpak / Anchor / Kinjal or equivalent reputed make A catagory ISI marked as approved) (Make of switch/socket- Schneider(Zencelo) / legrand( Myrius-NEXT GEN) / Panasonic (vision) or equivalent) (Make of accessories- Anchor/Havells) (Make of G.I box, face plate & cover-Schneider(Zencelo) / legrand( Myrius-NEXT GEN) / Panasonic (vision) or equivalent reputed make & model A catagory ISI marked as approved). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. | 4 | Nos | 1,714 | ₹6,856 |
| 4 | Supplying, fixing of 5 pin 6A socket outlet in the existing switch board with complete fitting by 01 no of 6A switch (modular type) (anti bactorial & flame retradant type) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. | 4 | Nos | 502 | ₹2,008 |
| 5 | Supplying, fixing of 5 pin 6A socket outlet & 6A clip in type switch (modular type) (anti bactorial & flame retradant type) in separate board with complete fitting & suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make- Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision). (Maximum 03 nos point in one circuit). All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. | 10 | Nos | 554 | ₹5,540 |
| 6 | Recessed wiring for 2 x 6 amp socket outlet controlled by 2 nos 6Amp, 250 V clip in type switch ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection on separate board as per direction of Engineer in Charge. (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa)/Havells(Equivalent model) or equivalent) | 4 | Nos | 935 | ₹3,740 |
| 7 | Supplying, fixing of 6 pin 16 amp modular socket outlet with 16Amp, 250 V clip in type modular switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision). (Maximum 02 nos point in one circuit). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. | 22 | Nos | 691 | ₹15,202 |
| 8 | Supplying, fixing of 6 pin 16 amp modular socket outlet (for Projector/ Geyser / 1.5 TR A.C point) ISI marked mounted on separate G.I moular box and 16A clip in type modular switch ISI marked mounted on separate G.I moular box at nearest location with modular face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision). (Only 01 no point in one circuit). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. | 3 | Nos | 749 | ₹2,247 |
| 9 | Supplying, fixing of 20A SPN Industrial type socket outlet with plug top and metal chained cover in sheet steel enclosure including all accesories and connection as per direction of Engineer in Charge. Make- Legrand / Schneider / Siemens / L&T. (Only 01 no point in one circuit). All the equipments should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. | 4 | Nos | 1,197 | ₹4,788 |
| 10 | Recessed wiring to submain in 4 x 16sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 50 mm dia non-metalic heavy duty PVC conduit along with 2 x 10 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) (POWER DB) | 45 | Mtrs | 691 | ₹31,095 |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.50 MB
BOQ_608735.xls
BOQ • 0.34 MB
corrigendum.pdf
PDF • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .