Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC LOWEST |
| 2 | L2₹1.6 Cr+₹5.7 L (3.73%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | ₹1.6 Cr+₹5.7 L (3.73%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹1.6 Cr+₹7.4 L (4.87%)Rejected-Finance | ₹1.6 Cr+₹7.4 L (4.87%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹1.7 Cr+₹13.5 L (8.92%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹1.7 Cr+₹13.5 L (8.92%) | L4 | Rejected-Finance NOT LOWEST |
| 5 | L5₹1.7 Cr+₹14.9 L (9.85%)Rejected-Finance | ₹1.7 Cr+₹14.9 L (9.85%) | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹1.8 Cr
EMD Value
₹2.6 L
Closing Date
5 Oct 2020, 6:00 pmClosed
CHIEF ENGINEER RnD
CHIEF ENGINEER RnD PICKET SECUNDERABAD
PROVISION OF CERTAIN UPGRADATION WORKS IN TECHNICAL BUILDING AT LRDE BENGALURU
2020_MES_339658_1
CERD/BAN/TOKEN/53 OF 2019-2020
Open Tender
Civil Works
Item Rate
270 days
LRDE CV RAMAN NAGAR BENGALURU
AS PER TENDER DOCUMENTS CLASS B CATEGORY a(i)
8 documents required · 8 mandatory
₹1,000
GARRISON ENGINEER I RnD WEST BENGALURU
₹2.6 L
18 Dec 2020
20 Apr 2020
12 Oct 2020
20 Apr 2020
5 Oct 2020
23 Jun 2020
20 Apr 2020 - 27 Apr 2020
Amount
Demolition of Cement Concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removing rubbish off the MD premises, complete all as specified and directed.
Plain cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate), 25mm thick as in sub base of floors, complete all as specified and directed.
Double charged full body Vitrified tiles, 600mm x 600mm x 9 to 10 mm thick, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including provision of screed bed of 15mm thick in CM 1:6, complete all as specified and directed.
Double charged full body Vitrified tiles, 600mm x 600mm x 9 to 10 mm thick, in vertical surfaces such as skirtings etc. set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including provision of backing coat of 10mm thick in CM 1:4, complete all as specified and directed. NOTE:- Height of skirting shall be 100mm
Non - skid Ceramic coloured tiles 600mm x 600mm x 9 to 10 mm thick, in floors etc., set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including provision of screed bed of 15mm thick in CM 1:6, complete all as specified and directed.
Non - skid Ceramic coloured tiles 300mm x 300mm x 7 to 8 mm thick, in floors etc., set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including provision of screed bed of 15mm thick in CM 1:6, complete all as specified and directed.
Non - skid Ceramic coloured tiles 600mm x 600mm x 9 to 10 mm thick, in vertical surfaces such as skirtings etc. set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including provision of backing coat of 10mm thick in CM 1:4, complete all as specified and directed. NOTE:- Height of skirting shall be 100mm
Rendering 15mm thick in CM 1:4 respectively in two coats viz., 10mm and 5mm thick on fair faces of brick work or concrete surfaces, duly mixed with water proofing compound in the second coat i.e., 5mm thick and finishing the surface even and smooth with out using exta cement, complete all as specified and directed. NOTE:- Water proofing compound shall be measured and paid separately under respective item of this Schedule.
Supply only water proofing compound, complete all as specified and directed.
Glazed ceramic tiles, coloured, in vertical surfaces such as dado, 300 mm x 450 mm x 7mm thick / 350mm x 450mm x 7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match, laid over and including provision of backing coat 10mm thick in CM 1:4, complete all as specified and directed.
Granite work (of any type), 20mm thick, machine cut, laid in floors, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing, laid over and including provision of screed bed or bedding layer, 15mm thick in CM 1:6, complete all as specified and directed.
Granite work (of any type), 20mm thick, machine cut, laid in skirting / dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing, laid over and including provision of backing coat, 10mm thick in CM 1:4, complete all as specified and directed.
Machine cut kota stone slab, 22-25mm thick, using single piece kota stone slab, using single piece Kota stone slab of size suitable to fit in treads, and 1000mm x 1000mm (minimum) in landings etc., set and jointed in neat grey cement slurry mixed with colouring pigment to match with the shade of slab, including rubbing and mirror polishing, laid over and including provision of screed bed 15mm thick in CM 1:6, complete all as specified and directed.
Machine cut kota stone slab 20-25mm thick, using single piece kota stone slab (pre-mirror polished) in risers of staircase, skirting and dado over pillars etc. to match in size and pattern, set and jointed in neat grey cement slurry mixed with colouring pigment to match with the shade of slab, laid over and including provision of backing coat of CM 1:4, 10mm thick, including rubbing and polishing, complete all as specified and directed.
Providing 1.00mm thick BRUSHBOND RFX GREY (which is a two component acrylic polymer modified cementitious coating which shall consists of Brushbond RFX powder and Nitobond BBX acrylic emulsion), grey in colour, of M/s FOSROC, applied using stiff brush, roller or trowel to obtain the desired thickness of plaster surface in sunken floor, all as per manufacturers instructions, complete all as specified and directed.
Plain cement concrete 1:5:10, type E2 (using 40mm graded stone aggregate), as in foundations, filling in mass concrete, complete all as specified and directed.
Rendering 15mm thick in CM 1:3 on fair faces of brick work or concrete surfaces, finishing the surface even and smooth with out using exta cement, complete all as specified and directed.
Complete removal of existing treatment from surfaces of walls by scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots with wire brushes and removing existing loose particles etc.,complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and directed.
Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, finishing the surface even and smooth with out using exta cement, complete all as specified and directed.
Preparation of previously untreated surfaces of brick, stone, concrete, asbestos cement or plastered surfaces of walls of any description over 10cm width or girth not otherwise described and applying two coat of plastic emulsion paint over a coat of priming paint (plaster coat) over two coats of internal grade wall care putty (the total thickness shall not be less than 1.50mm), finished even and smooth, complete all as specified and directed.
Preparation of new plastered surfaces of brick, stone, concrete, asbestos cement or plastered surfaces of walls of any description over 10cm width or girth not otherwise described and applying two coat of weather-proof antifungal exterior emulsion paint over a self coat of primer, over two coats of external grade wall care putty (the total thickness shall not be less than 1.50mm), finished even and smooth, complete all as specified and directed.
Preparation of old painted surfaces of brick, stone, concrete, asbestos cement or plastered surfaces of walls of any description over 10cm width or girth not otherwise described and applying one coat of weather-proof antifungal exterior emulsion paint, complete all as specified and directed.
Preparation of old painted surfaces of steel and iron surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
Preparation of old painted surfaces wood and wood based materials, of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on old works with one or more coats, complete all as specified and directed.
Taking down shutters of any description exceeding 1 sq.m but not exceeding 2 sq.m each and refixing in the same opening, complete all as specified and directed.
Preparation of old plastered surfaces of walls and applying one coat of white wash, complete all as specified and directed.
Preparation of old plastered surfaces of ceilings and applying one coat of white wash, complete all as specified and directed.
Exposed metal frame ceiling with 12mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mm x 600mm grid, complete all as specified and directed. NOTE:- Frame work for ceiling shall be measured and paid separately under Sl. Item No. 31.00 here-in-below. MAKE / MANUFACTURER: SAINT GOBAIN / ARMSTRONG
Gl frame work for seamless ceiling, grids of size 600mm x 600mm, comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20mm and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exceeding 1.2 metre length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre, with and including provision of Hangers 6mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40mm x 3mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, complete all as specified and directed. MAKE / MANUFACTURER: SAINT GOBAIN / ARMSTRONG
Demolition of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs / blankets, any thickness, including cover fillets, complete all as specified and directed.
Taking down chowkats or frames not exceeding 1.5sq.m each with shutters (without taking off shutters from the frames), complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5sq.m but not exceeding 4sq.m each with shutters (without taking off shutters from the frames), complete all as specified and directed.
Frosted glass, 4mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5sq.m in each pane, including provision of rubber beading etc., complete all as specified and directed.
Taking down shutters of any description exceeding 1 sq.m but not exceeding 2 sq.m each, complete all as specified and directed.
Powder coated aluminium (thickness of powder coating shall not be less than 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and directed.
Powder coated aluminium (thickness of powder coating shall not be less than 50 micron) window and ventilator shutters, side hung / sliding type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.), complete all as specified and directed.
Powder coated aluminium (thickness of powder coating shall not be less than 50 micron) shutter for window and ventilator, without sash bars fixed type, with one or more rebates including joining cleat for fixing, including minor fitting like lock, handle, roller for sliding etc., complete all as specified and directed. NOTE:- (i) Sheet glass with neoprene rubber packing and wire gauge shall be measured and paid separately under respective items of this Schedule. (ii) For payment purpose, only weight of alumininum section shall be measured and paid. However, cost of aluminium mongery and fittings shall deemed to be included in the quoted rate.
Prelaminated particle board (IS:12823 marked), interior grade, prelaminated both sides with decorative choice lamination, fixed with screws to timber frame work, 9mm thick, grade 2 quality, complete all as specified and directed.
Sheet glass, 4mm thick, ordinary quality and glazing in squares not exceeding 0.5 sq. m in each pane of aluminium window / ventilator etc., with and including provision of neoprene rubber packing and aluminium taper / square channel including fixing arrangement, complete all as specified and directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples / aluminium taper / square chaneel as applicable, complete all as specified and directed.
Pressed steel frames of size 105mm x 60mm x 1.25mm thick for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.
Flush shutters, factory made, 40mm thick, solid core construction, with particle board core and plywood face panels, commercial type on one side and other side is covered with decorative face veneer with and including provision of teakwood lipping 6mm thick fixed with nails / screws, complete all as specified and directed.
French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats, complete all as specified and directed.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification, with and including making good to jambs with CM 1:4 and finished the surface to match with the existing, complete all as specified and directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification, complete all as specified and directed.
Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, 100mm size, complete all as specified and directed.
Butt hinges, medium weight, cold rolled mild steel and fixed, 100mm size, with and including provision of necessary welding as required, complete all as specified and directed.
Aluminium anodised, barrel tower bolts of extruded section and fixed, 150mm long, complete all as specified and directed.
Extruded Aluminium alloy handles, fabricated type, anodised, 150mm long, complete all as specified and directed.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, 250mm long, complete all as specified and directed.
Floor door stopper of rubber and aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate shall be 150mm long, complete all as specified and directed.
Butt hinges, medium weight, cold rolled mild steel and fixed, 100mm size, fixed in repairs, complete all as specified and directed.
Aluminium anodised, barrel tower bolts of extruded section and fixed, 150mm long, fixed in repairs, complete all as specified and directed.
Extruded Aluminium alloy handles, fabricated type, anodised, 150mm long, fixed in repairs, complete all as specified and directed.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, 250mm long, fixed in repairs, complete all as specified and directed.
Floor door stopper of rubber and aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate shall be 150mm long, fixed in repairs, complete all as specified and directed.
Door closer hydraulically regulated, cast iron body, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed, fixed in repairs, complete all as specified and directed.
Powder coated aluminium (thickness of powder coating shall not be less than 50 micron) ventilator shutters, fixed type, with frosted glass 4mm thick at bottom half portion and fixed as louvers at top half portion, including provision of necessary glazing clips and necessary arrangements for louvers / glass etc., complete all as specified and directed. NOTE:- Panels / infills shall be measured and paid separately under relevant items of this Schedule.
Mild steel framed miscellaneous work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work, steel sections conforming to Fe-290 Gde E-165, complete all as specified and directed.
Dismantling of aluminium partition / windows of any size and any description, complete all as specified and directed.
Dismantling of structural steel work including doors, gates but excluding framed truss etc., complete all as specified and directed.
Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed.
Preparation of new or previously untreated steel and iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.
Prelaminated particle board (IS:12823 marked), interior grade, prelaminated both sides with decorative choice lamination, fixed with screws to timber frame work, 12mm thick, grade 2 quality, complete all as specified and directed.
Sheet glass, 4.80mm thick, ordinary quality and glazing in squares not exceeding 0.5 sq. m in each pane of aluminium window / ventilator etc., with and including provision of neoprene rubber packing and aluminium taper / square channel including fixing arrangement, complete all as specified and directed.
Solar control film 50micron reflective type sticked to glass panes as per instructions of manufacturers, complete all as specified and directed. MAKE:- As approved by GE.
GI tubing medium grade, galvanised with all fittings including short lengths, fixed to ceilings and concealed in walls with and including taking up or down steel tubing and connections, provision of suitable size of clamps including making necessary chases in walls and making good disturbed surfaces to match with the existing or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 15mm bore of pipe, complete all as specified and directed.
GI tubing medium grade, galvanised with all fittings including short lengths, ffixed to ceilings and concealed in walls with and including taking up or down steel tubing and connections, provision of suitable size of clamps including making necessary chases in walls and making good disturbed surfaces to match with the existing or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 20mm bore of pipe, complete all as specified and directed.
Rotational moulded HDPE water storage tanks (cylindrical vertical with closed top), 500 litre capacity (ISI embossed), triple layered, hoisted and fixed in position all as specified in SSR Part I, including dismantling water tanks from roof, or any description, 500 litre capacity, complete all as specified and directed.
Rotational moulded HDPE water storage tanks (cylindrical vertical with closed top), 1000 litre capacity (ISI embossed), triple layered, hoisted and fixed in position all as specified in SSR Part I, including taking down / dismantling existing water tank of any type 1000litre capacity from roof, complete all as specified and directed.
Bib taps (fancy type) with chromium plated wall flange, cast copper alloy, chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed, 15mm bore, fixed in repairs, complete all as specified and directed.
Pillar taps, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, 15mm bore, fixed in repairs, complete all as specified and directed.
Stop valves, cast copper alloy, fancy type, chromium plated (concealed type), with chromium plated wall flange, screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed, 15mm bore, fixed in repairs, complete all as specified and directed.
Ball valve high pressure PTMT with epoxy coated aluminium rod and high density plastic ball secured for iron pipe of dia 20mm (minimum weight shall be 210gram), fixed in repairs, complete all as specified and directed.
Ball valve high pressure PTMT with epoxy coated aluminium rod and high density plastic ball secured for iron pipe of dia 25mm (minimum weight shall be 455gram), fixed in repairs, complete all as specified and directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, 25mm bore of pipe, fixed in repairs, including cutting / threading old pipes and provision of new fittings such as Tee, socket, elbow, union etc., as required, complete all as specified and directed.
Waste coupling of PTMT (half or full threaded) 32mm dia (minimum weight shall be 45gram), including taking down old coupling, complete all as specified and directed.
PVC connections 15mm size with PTMT nuts of length 600mm, both ends having brass coupling nut and PVC washers, fixed in repairs, complete all as specified and directed.
PVC valveless, syphonic action type, flushing cistern, 10 litre capacity, low level, white, with inlet, ball valve, float and handle, jointing with and including provision of 32mm dia long / short flush pipe and connections to pipes and fixing of chain and pull, or lever, if any, fixed in repairs, complete all as specified and directed.
Vitreous China wash hand basin, flat back, size 450mm x 380mm white, excluding taps, waste pipe, chain and plug and porcelain stopper but including brackets, including cutting for and pinning in ends of brackets or erecting stand, with out provision of Waste coupling of PTMT 32mm dia (half or full threaded) (Minimum weight shall be 45gms), provision of waste pipe 32mm dia PTMT with inlet and outlet screwed for pipe including necessary packing, union and cap, fixed in repairs, complete all as specified and directed.
Waste pipe, corrugated, of length 800mm and 32mm dia, fixed in repairs, complete all as specified and directed.
UPVC (SWR) floor trap with and including, plain / single hole chromium plated grating including jointing to waste pipe with solvent cement, 75mm dia, complete all as specified and directed.
UPVC (SWR) multi-floor trap, plain with chromium plated grating including jointing with solvent cement, 75mm dia, including dismantling the damaged trap, complete all as specified and directed.
Vitreous China wash down water closet pan (pedestal pattern) , white (excluding flushing cistern and flushing pipe), including plastic water closet seat and cover, white, closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device, UPVC (SWR) 'P' or 'S' trap and connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc., fixed in repair, complete all as specified and directed.
Vitreous China white squatting pan, ‘Orissa’ pattern, size 580 x 440 mm, with integral foot rests, including UPVC 'P' or 'S' trap, front or back inlet and making connection to trap and to flushing pipe, anti-syphonic pipe, fixed in repair including dismantling existing squatting pan and making good disturbed floor, complete all as specified and directed.
Health faucet, chromium plated, fancy type, brass body with 1.0metre length and 15mm dia stainless steel braided rubber hose pipe and wall hook, fixed in position to wall, complete all as specified and directed.
Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (Minimum weight 60gms), complete all as specified and directed.
Push tap any colour high pressure of PTMT screwed for iron pipe and fixed, suitable for urinals, 15mm bore dia of pipe (Minimum weight 15mm-50gms), fixed in repairs, complete all as specified and directed.
Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe), fixed in repairs, complete all as specified and directed.
Vitreous china urinal partition white of size 310x700 mm, fixed in repairs, complete all as specified and directed.
Toilet paper holder, chromium plated, with flap guard, fixed to wall with chromium plated brass screws and PVC cleat, complete all as specified and directed. .
Soap dish holder, chromium plated, white colour, fixed to wall with chromium plated brass screws and PVC cleat, of size 160mm x 160mm x 90mm, complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for including cutting of reinforcement as required to facilitate demolition, incluidng removal of debris to outside MD land, complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in hard / dense soil, complete all as specified and directed.
Plain cement concrete 1:3:6, type C2 (using 40mm graded stone aggregate), as in foundations, filling in mass concrete, complete all as specified and directed.
Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161- 1979 grade St.-240, complete all as specified and directed.
Rolled mild steel sections as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., sections conforming to Fe 410-W (Gde E-250) quality - A, complete all as specified and directed.
Roof tiles, Mangalore pattern, interlocking at side joints, laid dry, complete all as specified and directed.
Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6, complete all as specified and directed.
Mild steel miscellaneous work as in Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and directed.
Mild steel sheet eaves gutters, galvanised class 3, half round with rounded edges, sheet shall be of 1.25mm thick and 150mm dia, complete all as specified and directed.
Rolled mild steel sections as in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, with riveted, bolted or welded attachment, sections conforming to Fe 410-W (Gde E-250) quality - A, complete all as specified and directed.
Complete removal of existing treatment from surfaces of walls by scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots with wire brushes and removing existing loose particles etc., and applying one coat of cement base paint over a coat of cement primer over two coats of internal grade wall care putty (the total thickness shall not be less than 1.50mm), finished even and smooth, and applying two coat of texture finish of colour as decided by GE. complete all as specified and directed.
Sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed.
Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, with grey cement and no pigment, complete all as specified and directed. MAKE:- As approved by GE
Providing cement concrete 1:3:6 type C1 (20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
Preparation of new plastered surfaces of brick, stone, concrete, asbestos cement or plastered surfaces of walls of any description over 10cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of primer, finished even and smooth, complete all as specified and directed.
Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed.
Point wiring complete with 1.5 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn through in and including 20mm dia rigid PVC conduit medium grade and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, including provision of 1.60mm thick modular metal flush boxes with modular metal frame plate for housing switches, sockets, regulators etc., including 1.5sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for one light / fan point / exhaust fan point / one bell point / one buzzer point controlled by one 6 amps one way modular switch, complete all as specified and directed. NOTE:- (i) The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per requirement etc. (ii) Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting PVC conduits and metal boxes and making good the disturbed surfaces to match with existing
All as per Sl. Item No. 112 here-in-before but for one 3-pin 5/6Amp socket outlet point on independent board controlled by one one-way 5/6Amp switch, complete all as specified and directed.
Point wiring complete with 4.0 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn through in and including 20mm dia rigid PVC conduit medium grade and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, including provision of 1.60mm thick modular metal flush boxes with modular metal frame plate and covered with 3.00mm thick plastic laminated white acrlyic cover including 4.0sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for 3-pin 15/16 Amp socket outlet point on independent board, complete all as specified and directed. NOTE: (i) The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per requirement etc. (ii) Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting PVC conduits and metal boxes and making good the disturbed surfaces to match with existing
Modular switch 6 Amp, one way, one module, 240V, complete all as specified and directed.
Modular switch 16 Amp, one way, one module, 240V, complete all as specified and directed.
Ceiling rose three terminal surface bakelite type AC 50 Hz 230V, fixed in replacement complete all as specified and directed.
Modular socket 6Amp, 2/3 pin combined, two module, 240V, complete all as specified and directed.
Modular socket 3/5-pin, 6/16Amp, flush type, two module, 240V, complete all as specified and directed.
Recess mounted full panel LED luminaire, 36Watt, 2' x 2' with white powder coated housing and frame in CRCA sheet, high efficiency LED grade diffuser, in-built electronic driver duly wired upto terminal block, CRI ≥ 80, ingress protection IP 20, ambient temperature range 0-50 degree centigrade, driver efficieny > 85% power factor > 0.95, THD < 10%, colour temp - 5700K, surge protection in CM - 3KV, 50000 burning hours (minium) as per L70 criteria, multi-stage isolated constant current - constant voltage operated driver with range 150-270V AC and safety extra low voltage safe level < 60V DC as per IEC Standard with LM70 & LM80 certification, complete all as specified and directed. MAKE:- Cat No. LLTLRN-36-FO-CDL of Crompton / Cat No. LULT01S036XN of Jaguar / Cat No. RC380BLED36S-6500 G4L60 IN 60 PSU OD of Philips
LED, 20Watt, high efficient, batten surface / wall mounted with specially designed extruded aluminium housing, high optically efficient poly-carbonate diffuser, in-built electronic driver duly wired upto terminal block, power consumption less than or equal to 20W, luminaire lumen greater than or equal to 2000lm, system efficiency greater than or equal to 100lm/w, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC62471 & electrical insulation class 1, ingress protection IP 20, colour rendering index CRI > 80%, temperature range 0-50 degree centigrade, driver efficieny > 85% power factor > 0.90, THD < 20% as per IEC 61000-3-2, colour temp - 6500K, surge protection 2.5KV, 50000 burning hours (minium) as per L70 criteria, multi-stage isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level < 60V DC as per IEC Standard with LM70 & LM80 certification, complete all as specified and directed. MAKE:- Cat No. ENDURLINEARNEOBS20WLED865SPCWH of Havells / Cat No. LGLZPCXO20XW of Jaguar
Recess mounted circular LED downlighter, 10/11Watt, with housing made up of die-cast aluminium for better heat management, high transmitivity diffuser for better light output and uniform light distribution without glare, driver and accessoires are pre wired for easy installation and long service, CRI > 80, LED efficacy > 130 lm/W, LED make:- Nichia / Cree / Osram / Everlite / Lumiled, ingress protection IP 20, ambient temperature range 0-45 degree centigrade, driver efficieny > 85% power factor > 0.95, THD < 20%, colour temp - 6500K, surge protection in CM - 2.5KV, 50000 burning hours (minium) as per L70 criteria, multi-stage isolated constant current operated driver with range 90-265V AC and safety extra low voltage safe level < 60V DC as per IEC Standard, cutout dia 165mm suitable for replacement of CFL downlighters, complete all as specified and directed. MAKE:- Cat No. INTEGRANEODLR10WLED840S of Havells / Cat No. DW295B LED 10S-4000PSUWH of Philips
Sub main wiring complete with 2 runs of 4 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit 20mm dia and its accessories and connecting terminal ends to DB's including providing 1 run of 4 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down old sub main wiring of any type and any size and making good disturbed surfaces to match with existing, complete all as specified and directed. NOTE:- (i) Two runs of 4 sq.mm copper conductor, one run of 4 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly. (iii) Quoted rate shall deemed to include the cost of making necessary chases in walls for inserting PVC conduit and making good disturbed surfaces to match with existing.
Sub main wiring complete with 2 runs of 6 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit 25mm dia and its accessories and connecting terminal ends to DB's including providing 1 run of 6 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down old sub main wiring of any type and any size and making good disturbed surfaces to match with existing, complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly. (iii) Quoted rate shall deemed to include the cost of making necessary chases in walls for inserting PVC conduit and making good disturbed surfaces to match with existing.
Sub main wiring complete with 4 runs of 10 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit 32mm dia and its accessories and connecting terminal ends to DB's including providing 2 runs of 10 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down old sub main wiring of any type and any size and making good disturbed surfaces to match with existing, complete all as specified and directed. NOTE:- (i) Four runs of 10 sq.mm copper conductor, two runs of 10 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly. (iii) Quoted rate shall deemed to include the cost of making necessary chases in walls for inserting PVC conduit and making good disturbed surfaces to match with existing.
Sub main wiring complete with 4 runs of 16 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit 32mm dia and its accessories and connecting terminal ends to DB's including providing 2 runs of 16 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down old sub main wiring of any type and any size and making good disturbed surfaces to match with existing, complete all as specified and directed. NOTE:- (i) Four runs of 16 sq.mm copper conductor, two runs of 16 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly. (iii) Quoted rate shall deemed to include the cost of making necessary chases in walls for inserting PVC conduit and making good disturbed surfaces to match with existing.
MCCB DB wall mounted vertical type TPN 12 way with provision for MCCB FP 100Amp 25KA rupturing capacity as incomer and SP / TP MCBs / Isolators as outgoing, double door with 200Amp rated bus bars for main distribution DB, including removal of old unserviceable DB in the wall and making good disturbed surfaces to match with the existing, with and including provision of thimble copper lugs complete all as specified and directed. NOTE:- MCBs or Isolators / MCCBs shall be measured and paid separately under respective items of this Schedule.
MCCB DB wall mounted vertical type TPN 8 way with provision for MCCB FP 63Amp 25KA rupturing capacity as incomer and SP / TP MCBs / Isolators as outgoing, double door with 200Amp rated bus bars for main distribution DB, including removal of old unserviceable DB in the wall and making good disturbed surfaces to match with the existing, with and including provision of thimble copper lugs complete all as specified and directed. NOTE:- MCBs or Isolators / MCCBs shall be measured and paid separately under respective items of this Schedule.
MCB DB SPN double door 8-way sheet metal enclosure with category of protection IP-42, 240V, with tinned copper 200Amp rated bus bar suitable for MCBs, including taking down existing unserviceable one and making good disturbed surfaces to match with existing, complete all as specified and directed.
MCB DB SPN double door 12-way sheet metal enclosure with category of protection IP-42, 240V, with tinned copper 200Amp rated bus bar suitable for MCBs, including taking down existing unserviceable one and making good disturbed surfaces to match with existing, complete all as specified and directed.
MCB DB SPN double door 12-way sheet metal enclosure with category of protection IP-42, 240V, with tinned copper 200Amp rated bus bar suitable for MCBs, including taking down existing unserviceable one and making good disturbed surfaces to match with existing, complete all as specified and directed.
Panel board, fixed in repairs, 'A' frame 'CN/CH' frame, factory made, double door suitable for MCCB 400Amp FP - 01 No as incomer and MCCB o100Amp FP - 08 Nos as outgoing and including 400Amp on load changeover switch - 01 No alongwith cable tray on both sides of suitable size and multifunction digital meter with CI's, complete all as specified and directed. NOTE:- MCCBs (incomer as well as outgoing) shall be measured and paid under respective items of this Schedule. MAKE:- Cat No. IHVA040008 of Havells or techno-commercially equivalent model in L&T / Indo-Asian
MCCB 4P, 400A, 50Hz with thermal magnetic release Icu = 36KA at 415Volts, Ics = 100% Icu and with adjustable over load (minimum 70% to 100%), fixed in repairs, complete all as specified and directed.
MCCB 4P, 100A, 50Hz with thermal magnetic release Icu = 25KA at 415Volts, Ics = 100% Icu and with adjustable over load (minimum 70% to 100%), fixed in repairs, complete all as specified and directed.
MCCB 4P, 63A, 50Hz with thermal magnetic release Icu = 25KA at 415Volts, Ics = 100% Icu and with adjustable over load (minimum 70% to 100%), fixed in repairs, complete all as specified and directed.
MCB SP 16 Amp, 240 Volt, 'C' curve, 10KA breaking capacity, including taking down existing unserviceable one and making good disturbed surfaces to match with existing, complete all as specified and directed.
MCB SP 3 Amp, 240 Volt, 'C' curve, 10KA breaking capacity, including taking down existing unserviceable one and making good disturbed surfaces to match with existing, complete all as specified and directed.
MCB SP 32 Amp, 240 Volt, 'C' curve, 10KA breaking capacity, including taking down existing unserviceable one and making good disturbed surfaces to match with existing, complete all as specified and directed.
MCB SPN 32 Amp, 240 Volt, 'C' curve, 10KA breaking capacity, including taking down existing unserviceable one and making good disturbed surfaces to match with existing, complete all as specified and directed.
MCB SPN 40 Amp, 240 Volt, 'C' curve, 10KA breaking capacity, including taking down existing unserviceable one and making good disturbed surfaces to match with existing, complete all as specified and directed.
MCB TP 40 Amp, 415 Volt, 'C' curve, 10KA breaking capacity, including taking down existing unserviceable one and making good disturbed surfaces to match with existing, complete all as specified and directed.
MCB TP 32 Amp, 415 Volt, 'C' curve, 10KA breaking capacity, including taking down existing unserviceable one and making good disturbed surfaces to match with existing, complete all as specified and directed.
Single pole and neutral (SPN) enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A, 240V flush to wall, fixed in repairs, complete all as specified and directed.
Triple pole and neutral (TPN) enclosure with a three pin and earth plug and socket complete with one triple pole MCB 63A, 415V flush to wall, fixed in repairs, complete all as specified and directed.
Supply, Installation, testing and commissioning of high wall Split type air condioning unit (Inverter type), BEE five star rated and EER 3.2, of capacity 2.0 TR complete with drive motor, air cooled condenser with all accessories varied speed and dual rotary compressor, including fixing the outdoor units as per manufacture recommendation and fixing indoor unit on wall, provinding and making interconnection including refrigerant piping (upto 3.0 RM) with nitryle rubber insulation and control cable from indoor to outdoor upto a distance of 3.0 metre, power cabling from isolator / enclosure to unit, first charging of non CFC / non HCFC of refregerant gas including cordless remote, drain piping of 25 mm dia for connecting drain lines from indoor unit to maximum of 3.0 metre to nearest drain points, complete all as directed and specified. MAKE:- VOLTAS / CARRIER / BLUESTAR
Voltage stabilizer, wall mounted, naturally cooled, indoor type, Automatic Boost / Buck for low and high voltage correction equipped with electronic circuit, relays of single phase 50Hz AC supply, complete designed for input voltage of 175 to 250 Volts and output voltage stabilized at 230Volts with an accuracy of ± 2.5%, TDR to 3min ± 20% seconds, of 5KVA capacity, complete all as specified and directed.
Copper tube for refrigerant of size 15.875mm (5/8 inches) - 9.525mm (3/8 inches) with PU insulation run on walls / ceiling duly fixed with clamps including making necessary hole for drawing out the pipes and connecting, complete all as specified and directed.
Microprocessor conrolled based conventional 4 zone fire alarm panel, complete all as specified and directed. MAKE:- HONEYWELL / NOTIFIER (SIEMENS)
SMF lead acid batteries for panel, complete all as specified and directed.
Photo-electric smoke detector with junction boxes and accessories, complete all as specified and directed. MAKE:- SIMPLEX / EDWADS / HONEYWELL / NOTIFIER
Heat detector with junction boxes and accessories, complete all as specified and directed.
Manual call point with junction boxes and accessories, complete all as specified and directed.
Copper Cable, 2 x 1.5sq.mm armoured, complete all as specified and directed.
Copper Cable, 2 x 1.5sq.mm un-armoured with PVC conduit 20mm dia / casing - capping / flexbile conduit with fixing accessories, complete all as specified and directed.
Conventional hooter cum strobe with junction boxes and accessories, complete all as specified and directed.
Response indicator, complete all as specified and directed.
Earthing provided in replacement complete with GI earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth wire of 4mm dia by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 15mm dia GI pipe 'light grade', watering pipe 20mm dia GI pipe 'medium grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:2:4) type B-1 earth chamber, 40mm thick precast RCC cover (1:2:4) type B1 mix with 6mm dia nominal reinforcement @ 100mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciified and as directed. NOTE:- Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate.
Lucky Enterprises
VARGHESECHACKO AND CO
devan enterprises
M.VENKATARAMANAPPA AND COMPANY
SREE BUILDERS
Vinayaka Enterprises
PRAGATHI BUILDERS
M/s JAYPEE ENTERPRISES
N RAJEGOWDA and CO
Meghana and Gowda Enterprises
UNITED ENGINEERS CORPORATION
meenakshi construction
RAMYA CONSTRUCTIONS
C R R CONSTRUCTIONS
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .