| Sl No | Description | Qty | Unit | GROMOS INDIA L1 | AEW ELECTRICAL PVT.LTD L2 |
|---|---|---|---|---|---|
| 1.00Deployment and operation of Pickup van/utility Vehical with 5 seater with back side provision of transporting/shifting material with driver as per TSS 1 | |||||
| 1.10 | Deployment of above said Vehicle | 600 | Day | 2,500 ₹15,00,000 Lowest | 3,000 ₹18,00,000 |
| 1.20 | Operation of above said vehicle | 15,000 | Km | 26 ₹3,90,000 | 15 ₹2,25,000 Lowest |
| 2.00 | Routine, Preventive and Breakdown Maintenance of 415V MV ACB Switchgear Panel as per TSS-2 | 2 | Nos. | 12,500 ₹25,000 Lowest | 30,000 ₹60,000 |
| 3.00 | Routine, Preventive and Breakdown Maintenance of Panels less than or equal to 15 feeders as per TSS-3 | 108 | Each | 6,500 ₹7,02,000 Lowest | 7,500 ₹8,10,000 |
| 4.00 | Routine, Preventive and Breakdown Maintenance of Panels more than 15 feeders as per TSS-4 | 64 | Each | 4,500 ₹2,88,000 Lowest | 7,500 ₹4,80,000 |
| 5.00 | Minor maintenace of PCC panels as per TSS-5 | 172 | Each | 1,500 ₹2,58,000 Lowest | 4,000 ₹6,88,000 |
| 6.00 | Routine, Preventive and Breakdown Maintenance of Distribution boards as per TSS-6 | 700 | Each | 2,450 ₹17,15,000 | 750 ₹5,25,000 Lowest |
| 7.00 | Routine Preventive and Breakdown Maintenance of all type of indoor lighting fixtures as per TSS-7 | 4,700 | Nos. | 580 ₹27,26,000 | 250 ₹11,75,000 Lowest |
| 8.00 | Routine Preventive and Breakdown Maintennance of all type of highbay/mediumbay lighting fixtures as per TSS-8 | 260 | Nos. | 850 ₹2,21,000 | 500 ₹1,30,000 Lowest |
Tender Value
₹1.5 Cr
EMD Value
₹3.0 L
Closing Date
8 Mar 2023, 6:00 pmClosed
Chief Engineer and Head, Technical Services Divisi
Chief Engineer and Head, Technical Services Division, BARC, Trombay, Mumbai-400085
Preventive and breakdown maintenance of electrical system for Common Facility Building, New Animal House, Service Building, Field House, 5ML tank, Nursery, WTP and TVS area, BARC Trombay, Mumbai 85
2023_BARC_741221_1
BARC/TSD/137/2022-23
Open Tender
Electrical Works
Works
730 days
BARC, Trombay
Please refer tender document
5 documents required · 5 mandatory
₹0
₹3.0 L
Conference Room, 2nd FL, TSD
28 Apr 2023
20 Feb 2023
15 Mar 2023
20 Feb 2023
8 Mar 2023
20 Feb 2023
20 Feb 2023 - 8 Mar 2023
1 Mar 2023
Amount
Deployment and operation of Pickup van/utility Vehical with 5 seater with back side provision of transporting/shifting material with driver as per TSS 1
Deployment of above said Vehicle
Operation of above said vehicle
Routine, Preventive and Breakdown Maintenance of 415V MV ACB Switchgear Panel as per TSS-2
Routine, Preventive and Breakdown Maintenance of Panels less than or equal to 15 feeders as per TSS-3
Routine, Preventive and Breakdown Maintenance of Panels more than 15 feeders as per TSS-4
Minor maintenace of PCC panels as per TSS-5
Routine, Preventive and Breakdown Maintenance of Distribution boards as per TSS-6
Routine Preventive and Breakdown Maintenance of all type of indoor lighting fixtures as per TSS-7
Routine Preventive and Breakdown Maintennance of all type of highbay/mediumbay lighting fixtures as per TSS-8
Routine Preventive and Breakdown Maintenance of 16A / 6A switch-socket power points as per TSS-9
Routine Preventive and Breakdown Maintenance of Metal clad industrial socket as per TSS-10
Routine Preventive and Breakdown Maintenance of Three phase points in MS boxs per TSS-11
Routine Preventive and Breakdown Maintenance of earthing stations as per TSS-12
Routine Preventive and Breakdown Maintenance of lightining air terminals/arrestors as per TSS-13
Routine Preventive and Breakdown Maintenance of Push button stations as per TSS-14
Routine Preventive and Breakdown Maintenance of local starter panel as per TSS-15
Routine Preventive and Breakdown Maintenance of ceiling/Padestal/single phase Exhaust fans as per TSS-16
Routine Preventive and Breakdown Maintenance of Exhaust fans of highbay areas as per TSS-17
Routine preventive and breakdown maintenance of signage indicators as per TSS-18
Routine Preventive and Breakdown Maintenance of Telephone terminal box(TTB) as per TSS-19
Routine Preventive and Breakdown Maintenance of Telephone points as per TSS-20
Routine Preventive and Breakdown Maintenance of Data points as per TSS-21
Routine preventive and breakdown maintenance of 350 KVA Lighting transformers as per TSS-22
Routine preventive and breakdown maintenance of VFD panel for chilled water/Hotcell system as per TSS-23
SITC of 400 KW solar plants as per the detailed specifications TSS-24
SITC of Primary lighting point wiring with a switch as per TSS-25
SITC of Looped Secondary lighting point wiring as per TSS-26
SITC of Primary power point wiring with 1 no 6A/16A 5pin combined socket and 16A switch and 1 no of 6A socket and 6A switch in 8 module box in casing caping as per TSS-27
SITC of Secondary power point wiring with 1 no 6A/16A 5pin combined socket and 16A switch and 1 no of 6A socket and 6A switch in 8 module box to be looped from primary power point in casing caping as per TSS-28
SITC of Looped Secondary power point wiring with 6A/16A combined socket and 16A switch in a 4 module box in casing caping as per TSS-29
SITC of Looped secondary power point with a combination of 5 Nos 6/16 A Switch and socket with MCB control in casing caping as per TSS-30
SITC of Primary power point wiring with 20A metal clad socket, top and 1 No. 20A MCB in separate M. S. Box for AC/exhaust fan in casing caping as per TSS-31
Only installation of Cat-6/2 pair telephone wire in casing caping( Cat-6 / 2 pair telephone wire & casing caping shall be provided by dept. free of cost) as per TSS-32
Only Installtion of LT armoured Cables dia 5 mm to 20 mm as per TSS-33
Only Installtion of LT armoured Cables dia 25 mm to 50 mm as per TSS-34
Only Installtion of LT armoured Cable dia 50 mm to 75 mm as per TSS-35
SITC of Glanding and termination of cable upto 10 sq. mm as per TSS-36
SITC of Glanding and termination of cable 10 sq. mm. to 50 sq. mm as per TSS-37
SITC of Glanding and termination of cable above 70 sq. mm. to 150 sq. mm as per TSS-38
SITC of Glanding and termination of cable 240 sq. mm. and above as per TSS-39
SITC of Straight joint of 300 sq. mm Al conductor cable as per TSS-40
SITC of Straight joint of 10/16/25/70 sq mm Al conductor cable as per TSS-41
SITC of End termination of telephone point with RJ-11/RJ 45 socket as per TSS-42
SITC of 32A 4 Pole MCB as per TSS-43
SITC of 63A/40A 4P MCB as per TSS-44
SITC of 32/40 A 3P MCB as per TSS-45
SITC of 10 A SP MCB as per TSS-46
SITC of 20A SP MCB as per TSS-47
SITC of 40 A DP ELCB as per TSS-48
SITC of 63 A DP ELCB as per TSS-49
SITC of 16 A 5 pin socket as per TSS-50
SITC of 6 A 5 pin socket as per TSS-51
SITC of 16 A Switch with indicator as per TSS-52
SITC of 6A Switch as per TSS-53
SITC of 32A HRC Fuse as per TSS-54
SITC of 63A HRC Fuse as per TSS-55
SITC of 100 A HRC Fuse as per TSS-56
SITC of 20 A HRC Fuse as per TSS-57
SITC of 80A HRC Fuse as per TSS-58
SITC of 160 A HRC Fuse as per TSS-59
SITC of 200 A HRC Fuse as per TSS-60
SITC of Overload relay for 5 HP/10 HP motors as per TSS-61
SITC of 70 W copper ballast as per TSS-62
SITC of Exhaust fan 300 mm sweep as per TSS-63
SITC of 63A 4P MCB with metal clad socket and plug in powder coated box as per TSS-64
SITC of 32 A 4P MCB with metal clad socket and plug in powder coated MS box as per TSS-65
SITC of 32/40/63 A 4P RCBO as per TSS-66
SITC of 32/40A 2P RCBO as per TSS-67
SITC of 63 A 2P RCBO as per TSS-68
SITC of 8 SWG copper wire as per TSS-69
SITC of 14 SWG copper wire as per TSS-70
SITC of 25 mm copper earthing strip as per TSS-71
SITC of Fire sealant material as per TSS-72
SITC of Cable terminals Connector 10/25/35 sq.mm as per TSS-73
SITC of 105 x 50 mm DLP trunking as per TSS-74
SITC of casing & capping 35 mm as per TSS-75
SITC of copper ballast for various lighting fixtures as per TSS-76
SITC of 2.5 sq. mm FRLS wire (R/Y/B/black/green) as per TSS-77
SITC of RJ45/RJ11 socket(1 module) with connector as per TSS-78
SITC of 32A 3P Contactor as per TSS-79
SITC of 63A 3P Contactor as per TSS-80
SITC of 20A 3P Contactor as per TSS-81
SITC of 400W SON type lamp as per TSS-82
SITC of 250W SON type lamp as per TSS-83
SITC of 70 W (SON) type lamps as per TSS-84
SITC of 11 W CFL lamp as per TSS-85
SITC of 250 W Metal hallide lamp as per TSS-86
SITC of 400 W Metal hallide lamp as per TSS-87
SITC of 18 W tube light as per TSS-88
SITC of 9 W LED lamp, BC type as per TSS-89
SITC of 36 Watt fluroscent tube lights as per TSS-90
SITC of 36 Watt Flameproof LED lighting fixture as per TSS-91
SITC of Panel door limit switch as per TSS -92
SITC of Digital DC Voltmeter AE Makeas per TSS-93
SITC of Digital DC Ammeter AE Make as per TSS -94
SITC of Ceiling Fan 1200mm as per TSS -95
SITC of Padestal Fan 450mm as per TSS -96
SITC of Wall mounted Fan 450mm as per TSS -97
SITC of 25 mm GI flexible conduit as per TSS -98
SITC of MS item as per TSS -99
SITC of Rubber mat as per TSS -100
SITC of Extension board with 5/15Amps socket and swtich 4nos with 10mtrs cord as per TSS -101
SITC of Obstroscopic timer 24hrs as per TSS-102
SITC of motor operator model no-3VA9267-OHA20 suitable for M0320A as per TSS -103
SITC of 3Pin Top 5Amps as per TSS-104
SITC of 3Pin Top 15Amps as per TSS-105
SITC of 4C TRS 2.5 sq. mm cu wire as per TSS-106
Only installation of SFU/MCCB/OL Relay/Contactor of various rating at site as TSS-107
Manual Excavation in normal soil as per TSS-108
Removal and re-rolling of various size LT cable as per TSS-109
SITC of 70 W LED outdoor fixture as per the specifications as per TSS-110
SITC of 50 W LED outdoor fixture as per the specifications as per TSS-111
SITC of LED Indication lamp for Panel (Red/Yellow/ Blue/Green) as per TSS -112
SITC of hand LED torch as per TSS-113
SITC of Emergency Light as per TSS-114
SITC of 7.5KW VFD as per TSS-115
SITC of 11.0KW VFD as per TSS-116
SITC of 22.0KW VFD as per TSS-117
SITC of 30.0KW VFD as per TSS-118
AEW ELECTRICAL PVT.LTD
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 4.90 MB
BOQ_779370.xls
BOQ • 0.28 MB
Tender_document.pdf
Tender Documents • 1.44 MB
Proforma_of_schedules_BARC_TSD_137_2022_23.pdf
Tender Documents • 0.14 MB
SCHEDULE-A_BARC_TSD_137_2022_23.pdf
Tender Documents • 0.15 MB
Man_Power_Recovery_sheet_BARC_TSD_137_2022_23.pdf
Tender Documents • 0.08 MB
TECHNICAL_BID_BARC_TSD_137_2022_23.xls
Tender Documents • 0.19 MB
CompletespecificationsTSD137.pdf
Tender Documents • 0.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .