Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹28.7 L+₹2.5 L (9.35%)Rejected-Finance 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
13 Sept 2024, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
REPAIR MAINT OF WATER SUPPLY, INTERNAL ELECTRIFICATION, EARTHING, SUMMER APPLIANCES, GEYSER DG SETS AND MISC EM WORKS AT AF STN PATIALA UNDER GE (AF) AMBALA
2024_MES_667682_1
GE AF/ AMB-T-14/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE AF AMBALA
₹84,000
Yes
16 Oct 2024
24 Jul 2024
16 Sept 2024
24 Jul 2024
13 Sept 2024
7 Aug 2024
Amount
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps,cills, sunshades, shelves, lintels, etc.and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed
Taking down existing sub main wiring any size complete all as specified and directed.
M&L for Sub main wiring with two single core 4 Sqmm stranded copper conductor PVC insulated and unsheathed cable ISI marked drawn in 25mm dia, medium grade, PVC conduit concealed in wall for sub main connection including 4Sqmm PVC insulated unsheathed copper conductor ISI marked as earth wire complete all as specified and directed by Engr-in-charge. Note:- (i) Two runs of 04 sqmm cable, one run of 04 sqmm earth conductor cable and one run of PVC conduits shall be measured and paid together as one unit length. (ii) Rate of cutting chasing,Pinning in & making good shall quoted in unit rates.
M&L for Sub main wiring with two single core 6 Sqmm stranded copper conductor PVC insulated and unsheathed cable ISI marked drawn in 25mm dia, medium grade, PVC conduit concealed in wall for sub main connection including 6.0SqmmPVC insulated unsheathed copper conductor ISI marked as earth wire complete all as specified and directed by Engr-in-charge. Note:- (i) Two runs of 06 sqmm cable, one run of 06 sqmm earth conductor cable and one run of PVC conduits shall be measured and paid together as one unit length. (ii) Rate of cutting chasing,Pinning in & making good shall quoted in unit rates.
Taking down carefully any type of battens or conduit point wiring with or without conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, etc removing material from site and making good disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing surface complete all as specified and directed.
M&L for point wiring with PVC insulated and unsheathed cable 1.5 Sqmm (nominal area) ISI marked multi-stranded copper conductor single core including suitable size of PVC casing & caping, concealed terminal boxes not less than 1.6 mm thick of required size with top cover 2.8 mm thick of plastic laminated sheet (Hylum) of required colour complete metal flush terminal boxes with all accessories including 1.5 Sq mm PVC insulated and unsheathed stranded copper wire conductor cable to common earth and connecting to earth dolly including colour coding of cable shall be Phase - Red, Neutral- Black and Earth- Green complete all as specified and directed Note:- (i) Cost of cutting chasing,Pinning in & making good shall be deemed to be included in the quoted rate.
One light/fan point controlled by one, one way switches complete all as specified and directed
One bell point controlled by push button on same board with other switches complete all as specified and directed
One socket outlet point 3 pin 5 Amps on the same board.complete all as specified and directed
One socket outlet point 3 pin 5 Amps on independent board complete all as specified and directed
M&L for point wiring with PVC insulated and unsheathed cable 2.5 Sqmm (nominal area) ISI marked multi-stranded copper conductor single core including suitable size of PVC casing & caping, concealed terminal boxes not less than 1.6 mm thick of required size with top cover 3 mm thick of plastic laminated sheet (Hylum) of required colour complete metal flush terminal boxes with all accessories including 2.5 Sq mm PVC insulated and unsheathed stranded copper wire conductor cable to common earth and connecting to earth dolly including colour coding of cable shall be Phase - Red, Neutral- Black and Earth- Green for 15 Amps socket outlet complete all as specified and directed Note:- (i) Cost of cutting chasing,Pinning in & making good shall be deemed to be included in the quoted rate. .
S&F in repair switch piano, flush type, 05 / 06 Amps, single pole, one way, 240 volts complete all as specified & directed
S&F in repair switch piano, flush type, 15 / 16 Amps, single pole, one way, 240 volts complete all as specified & directed
S&F in repair socket outlet 3 pin, 05 / 06 Amps, flush type, 240 volts complete all as specified & directed.
S&F in repair for socket outlet flush type 2 in 1, 6 pin , 5 and 15 Amps complete all as specified and directed.
S&F in repair bell push flush type switch, 5 Amp complete all as specified and directed by Engr-in-charge.
S&F in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed
S&F in repair 2.5 mfd capacitor suitable for ceiling fan complete all as specified and directed
S&F in repair 3.15 mfd capacitor suitable for exhaust fan complete all as specified and directed
M&L for point wiring with PVC insulated and unsheathed cable 1.5 Sqmm (nominal area) ISI marked multi-stranded copper conductor single core including 20mm dia medium grade PVC conduit concealed in wall / false ceiling, concealed metal flush boxes, including white cover plates with frame for fixing of modular switches/sockets etc with all accessories including 1.5 Sq mm PVC insulated and unsheathed stranded copper wire conductor cable to common earth and connecting to earth dolly including colour coding of cable shall be Phase - Red, Neutral- Black and Earth- Green complete all as specified and directed by Engr-in-charge for:- Note:- (i) Cost of cutting chasing,Pinning in & making good shall be deemed to be included in the quoted rate.
One light/fan point/Exhaust fan controlled by one, one way switch 6 amps. complete all as specified and directed
One bell point controlled by push button on the same board with other switch or independent.complete all as specified and directed
One 5 pin, 5 Amp switch socket out let on the same board with other switches.complete all as specified and directed
One 5 pin, 5 Amp switch socket out let on the independent board. complete all as specified and directed
M&L for point wiring with PVC insulated and unsheathed cable 2.5 Sqmm (Nominal area) stranded copper conductor single core including ISI marked 20 mm dia medium grade PVC conduit for point wiring, concealed in wall / metal flush boxes including white cover plates and frame for mounting switch/socket (modular) with all accessories including 2.5 Sqmm PVC insulated and unsheathed stranded copper wire conductor cable to common earth and connecting to earth dolly for one 5 pin, 15 Amps switch socket out let point on an independent board including colour coding of cable shall be Phase- Red, Neutral- Black and Earth- Green complete all as specified and directed by Engr-in-charge. Note:- (i) Cost of cutting chasing,Pinning in & making good shall be deemed to be included in the quoted rate.
S&F in repair modular switch flush type, 5 Amps, single pole, one way 1 module complete all as specified and directed
S&F in repair modular switch flush type, 16 Amps, single pole, one way 1 module complete all as specified and directed
S&F in repair modular socket , 5 pin, 5 Amps, multipurpose 2module complete all as specified and directed.
S&F in repair modular socket , 5 pin, 6/16 Amps, multipurpose 2module complete all as specified and directed.
S&F in repair ceiling rose, surface bakelite, size as per relevant IS, three terminals complete all as specified and directed.
S&F in repair modular fan step regulator 120W 2 module complete all as specified and directed.
S&F in repair modular bell push switch complete all as specified and directed by Engr-in-charge.
S&F in repair Buzzer, Ding Dong AC 230volts complete all as specified and directed by Engr-in-charge.
S&F in repair lamp holder,insulated body, with back PVC rectangular block for fixing of holder with screw complete all as specified and directed.
M&L for Point Wiring using approved colour coding as per IS with Zerohalogen flame reretardent (ZHFR) smoke free non toxic non corrosive with copper cable 1.5 sqmm (nominal area) single core insulated and unsheathed stranded cable 1100 Volts grade and including (ERW) stove enamelled concealed conduit heavy duty ISI marked complete all as specified and directed for one light point controlled by one way switch complete all as specified and directed. Note:- (i) Cost of cutting chasing,Pinning in & making good including taking down old wiring shall be deemed to be included in the quoted rate.
S&F in repair Switch flame proof rotary type with termination box in LM6,16A ,single pole 250 V complete all as specified and directed. Make: Sudhir, Shyam Switch gears, Crompton Greaves
S&F in repair flame proof switch socket & plug combined in LM6 cable termination box in LM6 ,16 A 250V ,2P+ earth complete all as specified and directed. Make: Sudhir/ Shyaam Switchgear/ Crompton Greaves
S&F in repair LED light fitting 2x16 Watt flameproof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed Make: Sudhir/ Shyaam Switchgear/ Crompton Greaves
Taking down of MCB DB with MCB 's and making good disturbed surfaces of wall complete all as specified and directed
S&F double door VTPN 4 way suitable for 4 pole MCCB as incoming & SP/TP MCB as outgoing, 200 Amps rated busbar, inter connection link, cable ties, earth bar etc complete all as specified and directed. Note:- MCCB & MCB to be measured and paid seperately
S&F double door MCB DB sheet metal enclosure single pole and neutral 240V with 200 Amp suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete confirming to IP 42/43 without MCB and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed.
S&F double door MCB DB sheet metal enclosure single pole and neutral 240V with 200 Amp suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete confirming to IP 42/43 without MCB and with enclosure blank plates for unused way suitable for 8 way complete all as specified and directed.
S&F double door MCB DB sheet metal enclosure single pole and neutral 240V with 200 Amp suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete confirming to IP 42/43 without MCB and with enclosure blank plates for unused way suitable for 12 way complete all as specified and directed.
S&F MCCB 100Amps, 240v, 4pole breaking capacity 16 KA complete all as specified and directed.
S&F MCB, TP 25 To 63 Amp, 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning.complete all as specified and directed
S&F MCB, single pole & neutral, 240 Volts (16 to 32) Amps,10KA complete all as specified and directed.
S&F MCB, single pole, 240 Volts (05 to 32) Amps,10KA complete all as specified and directed .
Taking down light fitting any description complete all as specified and directed .
S&F LED lights fitting 1x 20W, 220V, worm white AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
S&F LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed/ Surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
S&F round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.
S&F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Taking down fan, dismantling blades and removing fan and blades to store, complete all as specified and directed
Hanging only ceiling fan after repair and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed
M&L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and directed
M&L for rewinding of following fans with same gauge of super enameled copper wire complete,varnishing ,baking , connecting properly with sleeves assembling the same including replacement of unserviceable shackle and clamps with nots /bolts/washer /split pin and blade screws etc testing,complete all as specified and directed. NOTE: (a) Spare parts like bearing,capacitor,bushes if required will be measured and paid separately. (b) The rates shall be deemed to included dismantling of fan and reassembling after repair /replacement of worn out parts
Ceiling fan 1200 /1400 mm sweep
Exhaust fan 300 mm sweep
Exhaust fan 450 mm sweep
Wall mounted fans 400 mm /450mm sweep
S&F in repair metal bush bearing made out of gun metal/brass of same size suitable for ceiling fans,wall mounted fan and exhaust fans complete all as specified and directed.
S&F in repair ball bearing suitable Ceiling fan 1200 /1400 mm sweep complete all as specified and directed
S&F in repair ball bearing suitable Exhaust fan 300 mm sweep complete all as specified and directed
S&F new wall mounted fan motor single phase 240 Volt 50Hz complete all as specified and directed
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM five star rated with brushless direct current motor (BLDC) complete all as specified and directed
S&F exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers.complete all as specified and directed
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz RPM 1200, Copper winding of sweep 300m. complete all as specified and directed
S&F electric water heater, storage type steel body with glass line inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.complete all as specified and directed
Dismantling electric/water connection and taking down of storage type water heater,servicing,cleaning of inner tank etc.at site.and replacement of burnout parts etc. and refixing in situ all spd and directed. Note- (a) Detection and rectification of leakage of inner tank of geyser by brazing/welding/soldring. (b) Painting of geyser included in quoted rate. (c)wornout parts shall be measured and paid separately.
S & F in repair Heating element (round/ triangular) of size 1.5KW. complete all as specified and directed
S & F in repair Thermostat for 25 ltrs capacity geyser complete all as specified and directed.
S & F in repair Rubber Gasket for Inner Tank 25 Ltrs Capacity complete all as specified and directed.
S & F in repair Air release Valve for 25 Ltrs capacity . complete all as specified and directed
S & F in repair Fusible lead nut for safety pressure of existing type.complete all as specified and directed
S & F in repair Indicator Lamps for Geyser.complete all as specified and directed
S & F in repair PVC connections 15 mm size with PTMT nuts of up to length 600 mm length (for hot and cold water inlet and outlet ) complete all as specified and directed
Attending compliant for Comprehensive maintainance and servicing of refrigerator / deep freezer of capacity 165 to 310litres including labour for detecting the leakage of gas ,repairing leakage and recharging refrigerant, cleaning of cooling coil, condenser, compressors, with vacuum cleaner and cleaning solution, checking servicibility of electrical / electronic circuits relays, wiring kit, thermostat switches, knobs, etc. and keeping the units in satisfactory working conditions complete all as specified and as directed. Note: (a) Spares / parts / componenets/ refrigerant gas will be measured and paid separately under relevant items hereinafter and labour charges for replacement shall be deemed to be included in this unit rate quoted
S & F in repair thermostat switch with knob complete all as specified and directed
S & F in repair starting relay 1/8HP to 1/6HP with OLP complete all as specified and directed
S & F in repair copper filter, single capillary, pencil type complete all as specified and directed
Attending compliant for Comprehensive maintainance and servicing of water cooler cooling cap 40 litre/storage cap 80 litre cleaning of cooling/condensing coil, oiling of condenser fan motor, cleaning of drain pipe testing for smooth functioning complete all as specified and directed.
All as per BOQ srl item No. 61.00 here-in-above but capacity 150 Ltr complete all as specified and directed
Detection of refrigerent leakage from water cooler cooling cap 40 litre, repair of cooling coil/condensing coil for minor leakage if any flushing of system and gas charging in the system up to required qty, and sealing / brazing/soldering complete all as specified & directed.
Detection of refrigerent leakage from water cooler cooling cap 150litre, repair of cooling coil/condensing coil for minor leakage if any flushing of system and gas charging in the system up to required qty, and sealing / brazing/soldering complete all as specified & directed.
S & F in repair replacement new sealed compressor for water cooler cap 40litre (or nearest cap) single phase 230 volt, 50 HZ water cooler complee all as specified and directed. Note : gas charging will be measured & paid separate
M&L for rewinding of condensor fan motor of 1/32 HP with same gauge of copper insualated winding wire including insulating material complete all as specified and direted.
S&F in repair spare part for water cooler all as specified and directed
Run capacitor 25/36 MFD
Condensor fan blade
Condensor fan motor
Thermostate
CP self closing push cock 15mm dia
M&L for repair of drain tray by brazing/ nickle polishing including replacement of drain pipe of water cooler complete all as specified and directed.
M&L for replacement of legs of same size of water cooler cap 80/150 ltre complete all as specified and directed.
M & L for replacement of steel sheet (SS 304) of same gauge of body of water cooler including welding/ brazing etc , being into shape complete all as specified and directed.
M & L for two coat of spray painting complete outside of water cooler of cap 40/80 or 60/120ltr with harmartone paint over a coat of red oxide including scarping the old painted surface , denting and minor patch works complete all as specified and directed.
Attending compliant for Comprehensive maintainance and servicing of desert cooler of fan motor, water pump cleaning of PVC pipe testing including replacement of wood wool pad (set of three) etc for smooth functioning all as specified & directed.
M & L for rewinding of desert cooler motor of same gauge of copper insulated winding including material complete all as specifed and directed
M&L for fixing in replacement of plywood 6mm thick commercial grade in window of desert cooler, including painting of ply after coat of primer complete all as specified and directed.
S&F in repair following spare parts for desert cooler complete all as specified and directed
Capacitor 4.0 mfd
Fan motor with blade and clamp 106 watt or nearest cap single phase
Tullu pump /Water pump
M&L for preparation of surfaces of desert Cooler by scrapping old paint with sand paper, cleaning inner & outer surfaces of body and spray painting the inner surfaces and grills with two coats of black anticorrosive paint and outer surfaces with two coats of alluminium paint, over one coat of zinc chrome primer complete all as specified & directed.
Attending compliant for Comprehensive maintainance and servicing of split type air conditoner of capacity 1.5/2.0 Ton, cleaning of cooling/condensing coil,oiling of condenser fan motor, cleaning of air filter , detection of defective parts & replacement with new parts testing smooth functioning complete at site all as specified and directed. Note :- (i) Defective parts will be measured and paid separately . (ii) Job includes servicing , rectification of defects as one job (iii) Top up gas if required deemed to be included in unit rate Refrigerant gas will be measured as supply only.
M & L for detection of refrigerent leakage from split type AC repair of cooling coil / condensing coil for minor leakage if any flushing of system and gas charging in the system up to required and sealing / closing of charging value of split type AC / window AC capacity 1.5 TR complete at site all as specified and directed. Note:- (i) Leak detection with Nitrogen (ii) Evacation is carried out by using a vaccum pump and a recovery bottle , one the system evacuates.
M & L for detection of refrigerent leakage from split type AC repair of cooling coil / condensing coil for minor leakage if any flushing of system and gas charging in the system up to required and sealing / closing of charging value of split type AC / window AC capacity 2 TR complete at site all as specified and directed. Note:- (i) Leak detection with Nitrogen (ii) Evacation is carried out by using a vaccum pump and a recovery bottle , one the system evacuates.
S & F in repair replacement new sealed Rotary compressor of capacity 19000 BTU/Hour ( Nearest capacity ) , single phase 230 v , 50 Hz split type conditioner / window type air conditioner complete all as specified and directed. Note - Gas charging will be measured and paid separately .
S & F in repair replacement hermatcally sealed Rotary compressor of capacity 25000 BTU/Hour ( for 2 Ton AC) single phase 230 V , 50 Hz split type air conditioner all as specified and directed. Note - Gas charging will be measured and paid separately .
M & L for rewinding of condensor fan motor of split type AC of capacity 1.5 / 2.0 TR with same gauge of copper insulated winding wire including insulating material complete all as specified and directed.
M & L for taking down unserviceable burnt Indoor blower fan motor of split AC of capacity 1.5 / 2.0 TR , repairing / rewinding the same with super enamelled copper conductor of existing gauge, replacing the set of bearing including lathe work for making bearing seat complete & installing the same & commissioning complete all as specified & directed.
Supply, installing of condenser coils of split AC capacity 1.5 TR in any location / position including disconnecting electrical mains, removing the clutter, wires, cleaning, removing dust / dirt, etc., around and replacing condenser coil and finally put the rest back together and commissioning including disposing of old unserviceable condenser coil complete all as specified and as directed. Note: charging of refrigerant shall be measured & paid separately
Supply, installing of condenser coils of split AC capacity 2 TR in any location / position including disconnecting electrical mains, removing the clutter, wires, cleaning, removing dust / dirt, etc., around and replacing condenser coil and finally put the rest back together and commissioning including disposing of old unserviceable condenser coil complete all as specified and as directed. Note: charging of refrigerant shall be measured & paid separately
S&F in repair spare part for split type AC complete for any make / Model of capacity 1.5 / 2 TR all as specified and directed
Run capacitor 45/36 MFD
PCB with cardless Remote
Condensor motor with Blade
Condenser fan blades for spilt type AC units of capacity 1.5T/2T
Indoor swing motor of capacity 1.5T/2T
Wiring kit for split type AC units 1.5/2TR
Indoor Blower wheel
Suction and discharge valve set for type split AC 1.5/2T
Refrigerant Gas R-22
Refrigerant Gas R-134A
Refrigerant Gas R-32
Refrigerant Gas R-410
Supply, installing and testing in repair outdoor unit comprising of copper Condensor coil , motor with blade ,compressor rotary type of 1.5 Ton Split type Air conditioner in any location / position including disconnecting electrical mains, removing the wires etc. and commissioning including disposing of old unserviceable outdoor unit deposited to MES AC section yard complete all as specified and as directed. Note: charging of refrigerant shall be measured & paid seprately
Supply, installing and testing in repair Indoor unit of 1.5 Ton Split type Air conditioner in any location / position including disconnecting electrical mains, removing the wires etc. and commissioning including disposing of old unserviceable outdoor unit deposited to MES AC section yard complete all as specified and as directed. Note: charging of refrigerant shall be measured & paid seprately
S&F metal clad switch socket outlet with single pole and neutral enclosure with two pin and earth plug socket with 01No. single pole MCB 20Amps 10kA complete all as specified and as directed
Taking down of split type air conditioner from existing location and installation after repair of in same / other location including gas charging , testing , commisioning and comprising of following. Replacement of refrigerant tubing with insulating sleeve upto 6RM with brass flair nut. Drain pipe upto 6RM Air conditioner bracket-1 set interconnecting cable from indoor unit to outdoor unit
M&L for earthing with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 m below normal GL with the top edge of the plate not less then 1.5 m below the normal GL connected to GI wire 4mm dia protected by 15mm GI pipe (light grade) and watering pipe 20mm bore GI pipe (light grade) and chamber with PCC (1:4:8) type D2 using 40mm graded stone aggregate, coping with (1:3:6) type CI using 20mm graded stone aggregate and with RCC pit cover (50 mm thick) in 1:2:4 type B1 using 20mm stone aggregate, reinforced with 8mm for MS bar at 80mm c/c both way in lieu of CI pit cover with angle iron frame including excavation and earth work and removal of surplus soil of earth complete all as shown in electrical plate No 3 of SSR Part I and including charcoal dust, common salt and earth lead connected to earthing test point testing of earthing including taking down/up existing unserviceable earthing accessories and dispose off from site deppsited to MES store yard complete all as specified and directed. Note : (i) On testing, if the desired earth resistance is not obtained, enitre earthing shall be re-done by contractor till the desired earth resistance is obtained without accruing any extra cost to the government.
M&L for earthing with copper earth plate electrode 600 x 600 x3.15 mm thick buried directly in ground earth pit not less than 3.75 m below normal GL with the top edge of the plate not less then 2.50 m below the normal GL connected to copper strip 20x3mm protected by 50mm GI pipe (light grade) and watering pipe 20mm bore GI pipe (light grade) and chamber with PCC (1:4:8) type D2 using 40mm graded stone aggregate, coping with (1:3:6) type CI using 20mm graded stone aggregate and with RCC pit cover (50 mm thick) in 1:2:4 type B1 using 20mm stone aggregate, reinforced with 8mm for MS bar at 80mm c/c both way in lieu of CI pit cover with angle iron frame including excavation and earth work and removal of surplus soil of earth complete all as shown in electrical plate No 3 of SSR Part I and including charcoal dust, common salt, magnesium sulphate in layer 150mm thick in all side of plate and earth lead connected to earthing test point testing of earthing including taking down/up existing unserviceable earthing accessories and dispose off from site deppsited to MES store yard complete all as specified and directed. Note : (i) On testing, if the desired earth resistance is not obtained, enitre earthing shall be re-done by contractor till the desired earth resistance is obtained without accruing any extra cost to the government.
M&L for GI earthing strip 32x6mm laid in trenches / fixed on wall with saddles for inter connecting /extension in earthing including excavation and earth work complete all as specified and directed.
M&L for copper earthing strip 20mm x3mm laid in trenches / fixed on wall for inter connecting /extension in earthing including excavation and earth work complete all as specified and directed.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr deep in soft/loose soil for Erection of pole/laying cables etc., and getting out complete including forming bottom surfaces to required levels/slopes etc complete all as specified and directed.
Excavation in trenches for foundation not exceeding 1.5 meter wide and exceeding. 1.5 meter depth but not exceeding 3 m depth and not exceeding 10 sqm on plan and getting out in soft/loose soil for laying cable of defferent size and errection of pole and assay etc complete all as specified and directed.
Returning, filling-in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material(soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and II) for protection of underground cable of size 50 sqmm outer dia with all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified Note: Excavation and earth work shall be measured and paid separately
Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and II) for protection of underground cable of size 95 sqmm outer dia with all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified Note: Eexcavation and earth work shall be measured and paid separately)
M&L for boring/auguring suitable hole & insertion of 80 mm dia GI pipe including supply and inserting pipe not less than 600 mm below existing PCC/road/hard standing complete all as specified and directed. Notes:-(a) Cost of equipment, tools & plants & material required for boring shall be deemed to be included in the rates quoted
M & L for PCC,1:4:8 type D-2 (using 40 mm graded mechanically crushed stone aggregate) as in foundation, base of pole and in embedding blocks for stays complete all as specified and directed.
M&L for PCC,1:3:6 type C2 (using 40mm graded mechanicall crushed stone aggregate) as in coping/collar of electric poles including use of necessary form work and concrete finished even and smooth without using extra cement complete all as specified and directed.
M&L for PCC, (1:2:4) type B-1, (using 20 mm graded mechanically crushed stone aggregate) as in coping etc including necessary form work complete all as specified and directed.
M&L for crimping type heavy duty copper lugs/ferrule suitable for cable cross sectional area16/25 Sqmm complete all as specified and directed.
M&L for crimping type heavy duty copper lugs/ferrule suitable for cable cross sectional area50/70 Sqmm complete all as specified and directed.
M&L for crimping type heavy duty copper lugs/ferrule suitable for cable cross sectional area95/120 Sqmm complete all as specified and directed.
S&F LT End termination heat shrinkable End joints of size 70 to 120 sqmm 3.5 core complete all as specified and directed.
S&F LT End termination heat shrinkable End joints of size 16 to 50 sqmm 3.5 core complete all as specified and directed.
S&F LT heat shrinkable straight through joints of size 70 to 120 sqmm 3.5 core complete all as specified and directed.
S&F LT heat shrinkable straight through joints of size 16 to 50 sqmm 3.5 core complete all as specified and directed.
Taking UP/down the existing cables any description from trenches /poles/ walls etc complete all as specified and directed. Note :- Earth work measured and paid separetly
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 4.0 core X 10 Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 4.0 core X 16 Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 4.0 core X 25Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 50Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 95Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
S&F as in repair MCCBs 415V,16KA, 4 Pole 63 Amp with Adjustable thermal magnetic release as specified as directed.
S&F as in repair MCCBs 415V,16KA, 4 Pole 100 Amp with Adjustable thermal magnetic release as specified as directed.
S&F as in repair MCCBs 415V,16KA, 4 Pole 125 Amp with Adjustable thermal magnetic release as specified as directed.
S&F in repairs MCB TPN, 415V, 63A, 10kA complete all as specified and as directed
S&F as in repair Voltmeter Digital type suitable for 50-520 VAC(P-P), flush mounting 96x96mm class 0.5 complete all as specified and directed.
S&F as in repair Ampmeter Digital type suitable for 0-200Amps flush mounting 96x96mm class 0.5 complete all as specified and directed.
S & F in replacement of star delta starter suitable for 30 to 40 HP submersible pump with proper electrical connection including additional wiring etc complete all as specified and directed.
S&F in replacement of on load change over switch 415 V, 4 pole, 100 A as per existing make and model suitable complete all as specified and directed.
S&F in replacement of on load change over switch 415 V, 4 pole, 125 A as per existing make and model suitable equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement on load change over switch 415 V, 4 pole, 250 A as per existing make and model suitable equivalent make as per list of make at PScomplete all as specified and directed.
S&F in replacement of Contactor 3 pole 415 volts 200 Amps ML -12 (control voltage 230/415 as per existing model.) complete all as specified and directed.
S&F in replacement aviation obstruction light with all connected accessories to be fixed on GI Pipe 40/50mm bore light grade as per site requirement of existing make and model to be fixed on OHR or any other place complete all as specified and directed.
Comprehensive maintenance & servicing /cleaning of Automatic power factor panel,replacement of worn out part detection of faulty component /wiring & testing complete all as specified and directed . Note: Spare parts shall be measured and paid separately as supply only
S&F in repairs power capacitor for APFC panel, power quality,heavy duty 25kVAR, 440V, 50Hz, double dielectric capacitor, with rated current 32.8A, required phase discharge device with resistance appropriate insulation level and rated current including suitable sized copper conductor cable, thimbles, diode and testing on fixing and connecting up complete all as specified and as directed.
Comprehensive maintainance of oil cooled servo voltage stablizer 200 KVA 3 Phase by isolating ,disconnecting of input/output ,supply cable,opening of top of voltage stablizer,detecting of fault ,U/S component in control panel /dimmerstat /PCB etc,cleaning of serviceable parts/ component ,including replacement of worn out spare parts etc, if required complete all as specified and directed. Note: (i) Cost of replacement of worn out cable for wiring is deemed to included in quoted rates. (ii) Centrifuging and top up of stabilizer oil is deemed to be included in quoted rate.
Comprehensive maintainance of oil cooled servo voltage stablizer 3x50 KVA 3 Phase by isolating ,disconnecting of input/output ,supply cable,opening of top of voltage stablizer,detecting of fault ,U/S component in control panel /dimmerstat /PCB etc,cleaning of serviceable parts/ component ,including replacement of worn out spare parts etc, if required complete all as specified and directed. Note: (i) Cost of replacement of worn out cable for wiring is deemed to included in quoted rates. (ii) Centrifuging and top up of stabilizer oil is deemed to be included in quoted rate.
Comprehensive maintainance of oil cooled servo voltage stablizer 20 KVA 3 Phase by isolating ,disconnecting of input/output ,supply cable,opening of top of voltage stablizer,detecting of fault ,U/S component in control panel /dimmerstat /PCB etc,cleaning of serviceable parts/ component ,including replacement of worn out spare parts etc, if required complete all as specified and directed. Note: (i) Cost of replacement of worn out cable for wiring is deemed to included in quoted rates. (ii) Centrifuging and top up of stabilizer oil is deemed to be included in quoted rate.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engr-in-charge.
Dismantling pre stressed cement concrete poles 9 mtr long complete all as specified and directed.
Supply, erecting and fixing, in true vertical position/as strut, Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type type 410 SP-31 (9.00 metres long) complete with painting on exterior portion of polewith 2 coats of synthetic enamel paint over a coat of primer complete including taking out of existing pole all as specified and directed.
M&L for painting of PCC/steel poles 9/11 m long alongwith road/ peri meter upto 1.5 m height from pedestal, with two coats of synthetic enamel paint in 30 cm height 5 block of each airforce pattern incl painting of pole, coping with black paint and writing pole Numbers with white paint on black circular base incl. marking of HT/LT with Painting of pole cross arms bracket with two coats of aluminum paint over a coat of red oxide primer complete all as specified all as directed
M&L for painting of LT panels of any size and capacity, with two coats of synthetic enamel paint with two coats of aluminum paint over a coat of red oxide primer complete all as specified all as directed
Periodical, preventive and comprehensive maintenance of DG set of Cap 10 to 15 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect, inspection/testing of engine and alternator for smooth functioning of the DG set and including the replacement of following :- (i) Fuel/ lub filter one set (ii) Coolent in radiator (iii) Testing of engine control panel (iv) Cleaning of radiator, minor repair of leakages to be rectified. (v) Hose pipe set (vi) Fuel pipe/lubricant pipe (vii) Engine oil. Note: (i) Worn out parts repair/replacement if any other than above shall be measured and paid separately
Periodical, preventive and comprehensive maintenance of DG set of Cap 40 to 63 by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect, inspection/testing of engine and alternator for smooth functioning of the DG set and including the replacement of following :- (i) service kit for elements of fuel/air/lub filter one set (ii) top up of coolent in radiator (iii) Testing of engine control panel (iv) Cleaning of radiator, minor repair of leakages to be rectified. (v) hose pipe set (vi) fuel pipe/lubricant pipe (vii) Engine oil. Note: (i) Worn out parts repair/replacement if any other than above shall be measured and paid separately
Periodical, preventive and comprehensive maintenance of DG set of Cap 100 by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect, inspection/testing of engine and alternator for smooth functioning of the DG set and including the replacement of following :- (i) service kit for elements of fuel/air/lub filter one set (ii) top up of coolent in radiator (iii) Testing of engine control panel (iv) Cleaning of radiator, minor repair of leakages to be rectified. (v) hose pipe set (vi) fuel pipe/lubricant pipe (vii) Engine oil. Note: (i) Worn out parts repair/replacement if any other than above shall be measured and paid separately
Supply only following spare parts of DG set of kirloskar/Cummins DG set all as specified and directed.
V belt
Battery Terminal
Battery 90AH, maintenance free Genplus 12volts complete all as specified and directed.
Taking down old unservicable any type street lights and refixing after repair of street light /security lights including cleaning of perplex cover where ever required and tightening of loose connection on the pole, Complete all as specified and directed.
S&F PVC 3 core Cord Flexible copper insulated cable 1.5Sqmm/core in size Black/Grey colour complete all as specified and as directed.
Taking down the unserviceable bracket and material & labour for new bracket made out of 40mm GI tubing light grade 1.5m lay bent to shape suitable for fixing of any type street light fitting fixed to steel/concrete pole with two MS clamps made out of 50 x 6 flat iron, 16mm dia bolts nuts and washers of suitable length complete all as specified and directed.
M & L for FRP looping box with hinged cover weather proof with locking arrangement and appropriate size of aluminium bus bar of capacity 100 amps for single phase 230 V, 50 Hz electric supply mounted on PVC insulaters and fixed to pole by means of MS clamps, nuts boltss and washers including cables connection including one MCB SP 6 Amps including taking down existing looping box complete all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty two single core cables PVC insulated stranded aluminium conductor of size 6 sqmm served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular and including taking down old unserviceable wire dispose from site complete all as specified and directed.
S&F LED street light fitting 60 Watt 230 V AC warm white outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and including taking down old unserviceable wire dispose from site complete all as specified and directed.
S&F LED street light fitting 90 Watt 230 V AC warm white outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and including taking down old unserviceable wire dispose from site complete all as specified and directed.
S&F LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and including taking down old unserviceable wire dispose from site complete all as specified and directed.
S&F three phase timer switch -02 EC infra rays sensor with pre-drawn switching off timer, MCB power contractor, glass wool panel of maximum load capacity of 5 KWs, 415 volts, 50 Hz, degree of protection conforms to IP-66 complete all as specified and as directed.
Removing/taking out non clog type submersible sewage pumping set capacity 3 to 5 HP from sewage well after dewatering of sewage water and Rewinding of motor 3 to5HP of Non clog type submersible pumping set with suitable size of copper winding wire incl all insulation material & motor winding with pump dismantling the same for assessing & carrying out the repair/service as involved in subsequent items making good in running condition by repair/replacement of all unserviceable spare parts etc re-assembling, lowering the same into the well and making necessary connections, testing complete all as directed.
Taking up/down steel tubing GI pipelines/connection from trenches/wall / roof incl connected fittings/accessories and cleaning for refixing or removal to store for 15mm bore complete as specified and directed.
Taking up/down steel tubing GI pipelines/connection from trenches/wall /roof incl connected fittings/accessories and cleaning for refixing or removal to store for 20mm bore complete as specified and directed.
Taking up/down steel tubing GI pipelines/connection from trenches/wall /roof incl connected fittings/accessories and cleaning for refixing or removal to store for 25mm bore complete as specified and directed.
Taking up/down steel tubing GI pipelines/connection from trenches /wall incl connected fittings/accessories and cleaning for refixing or removal to store for 40mm or 50mm bore complete as specified and directed.
Supply and laying in trenches / fixing on wall / roof steel water tubing galvanised 15mm bore medium grade ISI marked with all fittings complete all as specified and directed
Supply and laying in trenches / fixing on wall / roof steel water tubing galvanised 20 mm bore medium grade ISI marked with all fittings complete all as specified and directed
Supply and laying in trenches / fixing on wall / roof steel water tubing galvanised 25 mm bore medium grade ISI marked with all fittings complete all as specified and directed
Supply and laying in trenches / fixing on wall steel water tubing galvanised 40 mm bore medium grade ISI marked with all fittings complete all as specified and directed
Supply and laying in trenches / fixing on wall steel water tubing galvanised 50 mm bore medium grade ISI marked with all fittings complete all as specified and directed
Supply, fixing and testing Gun metal Gate valve 50 mm dia screwed body ends and cast iron hand wheel conforming to IS :778 –1984 and ISI marked complete all as specified and directed.
Supply, fixing and testing Gun metal Gate valve 40 mm dia screwed body ends and cast iron hand wheel conforming to IS :778 –1984 and ISI marked complete all as specified and directed.
Supply, fixing and testing Gun metal Gate valve 25 mm dia screwed body ends and cast iron hand wheel conforming to IS :778 –1984 and ISI marked complete all as specified and directed.
Supply, fixing and testing Gun metal Gate valve 20 mm dia screwed body ends and cast iron hand wheel conforming to IS :778 –1984 and ISI marked complete all as specified and directed.
Supply, fixing and testing Gun metal Gate valve 15 mm dia screwed body ends and cast iron hand wheel conforming to IS :778 –1984 and ISI marked complete all as specified and directed.
Supply, fixing, testing and commissioning Double flanged non-rising stem type cast iron sluice valve suitable for 150 mm dia bore pipe with hand wheel and suitable for pressure rating of PN :1.6 duly drilled holes for fixing of nuts and bolts, stem made of high tensile brass ISI marked and conforming to IS : including rubber gasket, nuts, bolts and washers complete all as specified and directed.
Supply, fixing, testing and commissioning Double flanged non-rising stem type cast iron sluice valve suitable for 100 mm dia bore pipe with hand wheel and suitable for pressure rating of PN :1.6 duly drilled holes for fixing of nuts and bolts, stem made of high tensile brass ISI marked and conforming to IS : including rubber gasket, nuts, bolts and washers complete all as specified and directed.
Supply, fixing, testing and commissioning Double flanged non-rising stem type cast iron sluice valve suitable for 80 mm dia bore pipe with hand wheel and suitable for pressure rating of PN :1.6 duly drilled holes for fixing of nuts and bolts, stem made of high tensile brass ISI marked and conforming to IS : including rubber gasket, nuts, bolts and washers complete all as specified and directed.
S& F as in repair for CI/DI any size spigot socketed pipe bends only (any type radius and angle), tappers any type (Straight, bend, increasing, decreasing or double socket etc), Tee pieces single branch double branch, cross (all sockets or socket and spigot ) collars, caps and plugs up to 150 mm capacity.complete all as specified and directed.
M&L for cutting cast iron 200/150/100 mm bore pipe in position for insertion of new Tees, branch and reducing to required length complete all as specified and directed. Note : both sides cut shall be measured as one unit
M&L run lead joints of spigot and socket pipes and fittings for DI/CI pipe 150 mm bore size of pipe including provision of bolts, washers and white lead or mineral oil complete all as specified. Note;- Earth work will be measured and paid separately.
M&L run lead joints of spigot and socket pipes and fittings for DI/CI pipe 100 mm bore size of pipe including provision of bolts, washers and white lead or mineral oil complete all as specified. Note;- Earth work will be measured and paid separately.
Supply only calcium based white to off white free flowing solid granules chemicals having chlorine content of minimum 60% for chlorination in 45 kg packing complete all as specified and directed.
M & L for lifting of column pipe, flanged 100mm bore with submersible cable from bore hole of tube well, pump set of any capacity and lowering after repair in borewell complete all as specified and directed by Engr-in-Charge. Note: (i) Lifting & lowering of pump set upto 120 mtrs deep will be deemed to be included in unit rate. (ii) Lifting & lowering of pump set to be completed out within 24 hrs from intimation. (iv) Rubber gasket, nuts & bolts for replacement deemed to be included in unit rate.
Opening of submersible motor for rewinding with PVC coated copper winding wire as per existing gauge insulation material,after stripping of existing worn out winding, M&L for sealing kit, O- ring, Gasket, water drain plug, sand guard, cable packing ring, cable gland ring, upper/lower bearing, adopter piece, motor key, upper lower flange, neck ring, suction case, Hex bolt, Circlip washer, Motor coupling, thurst plate,motor bush etc complete, reassembling with pump set of the capacity upto 35 HP complete all as specified and directed.
M&L for Repair/Overhauling of submersible pump set including replacement of Hex bolt, Circlip washer, bowl stud, pump shaft, rotor bleach, pump bush etc complete and reassembling pump set of capacity upto 35 HP, complete all as specified and directed Note : Impeller shall be measured and paid seperately however labour rates inclusive of quoted rate.
M&L for rewinding of Induction motor 5HP with Copper winding wire are per exisiting size and type incl all type packing/gaskit/nutbolt along with all insulation material & motor winding provided with thermal switches for protection against excessive temperature rise complete all as specified and as directed.
Supply only galvanized iron column pipe 100 mm medium grade (approximately 3 mtr length) each duly flanged at both ends by welding with slots for housing two Nos submersible cable and holes for fixing nut bolts complete as specified and directed
Design, Supply, installing testing and commissioning factory fabricated outdoor type totally enclosed LT cubical panel board suitable size with busbar, conforming to relevant IS and protection class IP-65 ,dust, vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated ,mounted on 40x40x5mm MS angle iron frame, duly welded in shape and coated with two coats of synthetic enamel paint of approved color over a coat of red oxide primer including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm graded stone aggregate ,panel base to be 500mm above ground level with suitable compartments for controls and Monitors including cable glands for incoming and outgoing cables, locking arrangement, including accommodating, S&F the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed by Engr-in-charge. Including S&F the following :-
M&L for Cleaning, Desludging/ dewatering of valve pit chamber, Bailing out the leakage water and fill the gland packing & rubber packing in sluice valve etc complete all as specified and directed by Engineer-in-Charge.
Potable water chemical analysis testing of water to be conducted by laboratories authosied by NABL, PPCB & CPCB. The test will analysis pH,colour, Odour, Taste, Turbidity, total Hardness, Total Alkalinity, Iron, chloride, Residual Free Chlorine, Fluroide, Total Dissolved Solid, Sulphate, Nitrate, Total Coliform, E.coli etc including collecting of water from the source in a spacilised glass bottel used for this purposel, and collecting the reports from the Lab. Note: Cost of collection of sample, transporting the sample to lab, collection of report and all expense of testing shall be borne by contractor
Cleaning of SWT capacity of 50000 Gln water throughly by removing mud grits etc complete all specified and directed. Notes : rates quoted shall deemed included for followng :- (i) Cleaning inner surfaces of tanks complete with scraping wth steel wire bruses, pressure wash, removing mud, sludge collected inside the tank manualy, removal of mud to a distance not exceeding 50mtrs. (ii) Washing with clean water and bieaching powder or with high streanth calcium chloride mxture thoroughly internally removing left out sludge if any to a distance not evceeding 50 mtrs including writing capacity of SWT, cleaning date, due dated for cleaning with black synthetic enamel paint with existing pattern.
Cleaning of OHT capacity of 75000 Gln water throughly by removing mud grits etc complete all specified and directed. Notes : rates quoted shall deemed included for followng :- (i) Cleaning inner surtaces of tanks complete with scraping wth steel wire bruses, pressure wash, removing mud, sludge collected inside the tank manualy, removal of mud to a distance not exceeding 50mtrs. (ii) Washing with clean water and bieaching powder or with high streanth calcium chloride mxture thoroughly internally removing left out sludge if any to a distance not evceeding 50 mtrs including writing capacity of OHT, cleaning date, due dated for cleaning with black synthetic enamel paint with existing pattern.
M&L for attending of water supply complaints for any leakage / blockage in GI pipe lines of size 20mm / 25mm/40mm /50mm bore taking up serviceable / unserviceable GI water pipe lines all fittings/fixtures from trench including supply and laying GI tubing 20mm / 25mm/50mm bore up to 1 mtr length (max) including necesssary cutting, threading suitable for 20mm / 25mm/50mm including necessary excavation and earth work up to 1 Cum to repair the leakage / clearing the blockage in the pipe line and testing on completion complete all as directed at site NOTE : Excavation more than 1 Cum and GI fittings shall be measured and paid separately under relevent item of this schedule
SWAMI ENGINEERS (BID ID -3075413)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .