| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.5 Cr+₹9,738.61 (0.06%)Rejected-Finance 143 SHASTRI NAGAR LAKHIMPUR KHERI | KHERI | UTTAR PRADESH | 261501 | ₹1.5 Cr+₹9,738.61 (0.06%) | L2 | Rejected-Finance L2 |
| 3 | L3₹1.5 Cr+₹76,891.75 (0.51%)Rejected-Finance | ₹1.5 Cr+₹76,891.75 (0.51%) | L3 | Rejected-Finance L3 |
Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
4 Oct 2024, 3:00 pmClosed
Superintending Engineer
3rd Circle Irrigation Works, 139, Mall Road, Pratappura, Agra
Repair and renovation work of Jiledari Office and staff residence in Irrigation Colony Bah.
2024_UPIDC_950384_4
04/SE/2024-25
Open Tender
Civil Works
Item Rate
180 days
Bah Agra
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
₹3.4 L
23 Oct 2024
29 Sept 2024
4 Oct 2024
29 Sept 2024
4 Oct 2024
29 Sept 2024
Amount
Removing old lime or cement plaster with disposal of refuse within 60 m as per direction of Engineer-in-charge
Dismantling brick work or stone work and cement concrete in cement mortar and including stacking of material with in a distance of 60 M as per direction of Engineer-in-charge
Demolishing RCC work manually/by mechanical means including stacking of Steel bars and disposal of unsurvedable material within 50 M lead as per direction of Engineer-in-charge
Removing dry or oil bound distemper, waterproofing cement paint and the like by scraping as per direction of Engineer-in-charge
Dismantling doors and window leaves including stacking material with in 60 M as per direction of Engineer-in-charge
Dismantling C.C. or brick or granolithic floor including base concrete and including stacking of dismantled material with in 60 M distance as per direction of Engineer-in-charge
Class-150 Brick Work in proportion 1 : 4 in Cement Mortar (1 cement:4 coarse sand) i/c all cost of labour, material, T&P etc complete as per direction of Engineer-in-charge
12 mm thick Cement plaster proportion in 1 : 4 cement mortar (1 cement : 4 coarse sand) i/c all cost of labour, material, T&P etc complete as per direction of Engineer-in-charge
RCC work in proportion 1:1.5:3 (1 cement : 1.5 coarse sand : 3 stone grit) Cement concrete mix with 10-20 mm crushed stone grit i/c all cost labour, material, T&P etc complete
Centering & shuttering for R.C.C./R.B. work including cost of centering & shuttering as per direction of Engineer-in-charge
TMT Steel work in reinforcement in RCC work i/c cutting, bending, binding, curtailment of bars, placing in position etc. for proper completion of work as per direction of Engineer-in-charge
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete i/c curing, cost of all material, labour, T&P etc. complete as per direction of Engineer-in-charge
Finishing walls with acrylic smooth exterior paint (Apex) of approved brand and manufacture and of required curing and cost of all material, labor, T&P etc. required for proper completion of work as per direction of Engineer-in-charge
Providing and fixing ISI marked flush door shutters cofirmimg to IS : 2002 (Part I) non decorative type, core of block board construction with frame of Ist class haed wood and well matched teak 3 mm ply veneering with vertical grains or cross bands and face veneers on both faces of shutter, 35 mm thick i/c ISI marked stainless steel butt hinges with necessary screws (Excluding cost of fittings) as per direction of Engineer- in-charge
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood, 30 mm thick shutters as per direction of Engineer- in-charge
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : Second class teak wood as per direction of Engineer- in-charge
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 30 mm thick shutters as per direction of Engineer- in-charge
Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia wire and 1.4 mm wide apperture with matching wood beading including all cost of labour, material and T&P etc as per direction of Engineer- in-charge
Providing and fixing 25 mm thick shutters for cup board etc. : Panelled or panelled and glazed shutters : Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws as per direction of Engineer- in-charge
Applying ready mix primer including cost of material on new wood surface. (Rates inclusive of repairing surface, preparing of surface by thoroughly cleaning oil, grease, dirt and other foreign material and scour with wire brush etc.) * Painting 1st coat over priming coat (but excluding cost of priming coat) on new wood surface including cleaning the surface of all dirt, dust and other foreign matter, sand papering and stopping including cost of materials labour Tools and Plants etc as required for proper completion of work. Paint shall be used as per standard I.S. specification * Extra for over coat of paint after first coat as per direction of Engineer- in-charge
Applying ready mix primer including cost of material on steel and other metal surface. (Rates inclusive of repairing surface, preparing of surface by thoroughly cleaning oil, grease, dirt and other foreign material and scour with wire brush etc.) * Painting 1st coat over priming coat (but excluding cost of priming coat) on new steel surface including cleaning the surface of all dirt, dust and other foreign matter, sand papering and stopping including cost of materials labour Tools and Plants etc as required for proper completion of work. Paint shall be used as per standard I.S. specification * Extra for over coat of paint after first coat as per direction of Engineer- in-charge
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick as per direction of Engineer- in-charge
Brick on laid flat flooring with bricks of class designation 150 on a bed of 12 mm cement mortar including filling the joints with 1:4 cement mortar (I cement : 4 fine sand), but bricks laid on flat with mortar, non modular bricks as per direction of Engineer- in-charge
Providing and laying vitrified tiles in floor without Lean concrete of 600x600 mm size thickness 10 mm with water absorption less than 0.08 % and confirming to IS : 15622 of approved brand and manufacturer, in desired colours and shade, laid with cement based high polymer modified quick set tile adhesive water-based confirming to IS : 15477, including grouting of joints as per direction of Engineer- in-charge
Black granite polished stone flooring with 18mm thick marble stone, as per sample of marbal approved by engineer in charge, over 20 mm average thick base of cement mortar 1:4 (I cement : 4 fine sand), laid and joined with grey cement slury, including rubbing and polishing complete with : black granite stone quality as per direction of Engineer- in-charge
Steel work welded and built up section of Framed work including cutting hoisting, fixing in position and applying a priming coat of approved Steel primar using a structural steel structure as required in grating, frames, guard bar, ladder, railing, brackets, gates and similar works as per direction of Engineer- in-charge
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
Providing and fixing tiled false ceiling of specified material of size 595x595 mm in true horizontal level, suspended on inerlocking metal grid of hot dipped galvenized steel section consisting of main "T" runner 24x38x0.3, 1200mm c/c, and cross "T" 24x25x0.3 mm, 1200 mm long & 600 mm c/c to form a grid of 1200x600 mm and secondry cross "T" 24x25x0.3 mm 600 mm long to be interlocked at middle of 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles in the grid i/c required cutting/making opening grills, fittings, fixtures etc. Main "T" runner to be suspended from ceiling using GI slotted cleats of size 27x37x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fastener, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x30x0.8 mm spaced at 1200 mm c/c along main T, bottom exposed width of 24 mm of all T sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-Charge. i/c all cost of labour, material and T&P etc. complete
Providing and fixing in wall lining 12 mm thick medium density fibre board prelaminated one side decorative lamination and other side balancing lamination, with necessary fixing arrangement and screws etc. complete as per the direction of Engineer-in-charge.
Providing and fixing nickel plated M.S. pipe curtain rods 1.25 mm thick with nickel plated brackets : 25 mm dia (heavy type) as per the direction of Engineer-in-charge.
Providing and fixing Aluminium extruded section body tubular type Universal hydraulic door closer (having brand logo with ISI, IS : 3564, imposed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc complete as per the direction of Engineer-in-charge.
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm as per the direction of Engineer-in-charge.
Providing and fixing aluminium door tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS-1868) transparent or dyed to required colour for shade with necessary screws etc. complete as per the direction of Engineer-in-charge :100x10 mm
Providing and fixing aluminium door tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS-1868) transparent or dyed to required colour for shade with necessary screws etc. complete as per the direction of Engineer-in-charge :150x10 mm
Providing and fixing aluminium handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS-1868) transparent or dyed to required colour for shade with necessary screws etc. complete as per the direction of Engineer-in-charge :100 mm
Providing and fixing aluminium handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS-1868) transparent or dyed to required colour for shade with necessary screws etc. complete as per the direction of Engineer-in-charge :125 mm
Providing and fixing aluminium hanging floor door stopper ISI marked anodized (anodic coating not less than grade AC 10 as per IS-1868) transparent or dyed to required colour for shade with necessary screws etc. complete :Twin rubber stopper as per the direction of Engineer-in-charge.
PCC in proportion 1:3:6 concrete mix (1 cement : 3 coarse sand : 6 stone ballast) in 45-63 mm stone ballast i/c all cost of labour, material, T&P etc. complete as per the direction of Engineer-in-charge.
PCC in proportion 1:2:4 concrete mix (1 cement : 2 coarse sand : 4 stone grit) with 10-20 mm crushed stone grit i/c all cost of labour, material, T&P etc. complete as per the direction of Engineer-in-charge.
Cement concrete flooring in proportion 1:2:4 concrete mix (1 cement : 2 coarse sand : 4 graded stone grit) finished with the floating Coat of neat cement, including cement slurry but excluding the cost of nosing of steps etc. complete 40 mm thick with 20 mm nominal size stone aggregate
Centering and shuttering of C.C. work including rent of shuttering material, labour and T&P required for proper completion of work for slab, lintels, sun shades, columns & walls etc. as per direction of Engineer-in-charge.
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick including all cost of labour, material and T&P etc as per direction of Engineer- in-charge
Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire as per the direction of Engineer-in-charge.
Earth work in foundation in dry ordinary soil (loam clay or sand) including lift up to 1.5 meter and lead up to 30 meter and including back filling, watering and ramming of excavated earth into the trenches or into the space between the structure and the sides of foundation trenches or into the plinth with removal and disposal or surplus earth as directed by the Engineer-in-charge up to a distance of 30M from the foundation trenches : (Building) as per the direction of Engineer-in-charge.
Providing, laying, spreading and compacting stone aggregates 20-40 mm specific sizes to water bound macadam specification i/c spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density. Grading 3 as per specification clause 405 as per the direction of Engineer-in-charge.
Supply and laying of I shaped (Zigzag) precast interlocking tiles (paver block) of 100 mm thickness (Compressive strength not less than 30Mpa and weight 4.50 Kg) i/c 25 mm thick local sand base levelling and dressing of surface to required level and slope, filling joints with local sand all complete work as per the direction of Engineer-in-charge: grey colour
Supply and laying of I shaped (Zigzag) precast interlocking tiles (paver block) of 100 mm thickness (Compressive strength not less than 30Mpa and weight 4.50 Kg) i/c 25 mm thick local sand base levelling and dressing of surface to required level and slope, filling joints with local sand all complete work as per the direction of Engineer-in-charge : Red/Yellow colour
Supply and laying of I shaped (Zigzag) precast interlocking tiles (paver block) of 80 mm thickness (Compressive strength not less than 30Mpa and weight 4.50 Kg) i/c 25 mm thick local sand base levelling and dressing of surface to required level and slope, filling joints with local sand all complete work as per the direction of Engineer-in-charge : grey colour
Supply and laying of I shaped (Zigzag) precast interlocking tiles (paver block) of 80 mm thickness (Compressive strength not less than 30Mpa and weight 4.50 Kg) i/c 25 mm thick local sand base levelling and dressing of surface to required level and slope, filling joints with local sand all complete work as per the direction of Engineer-in-charge: Red/Yellow colour
Painting & printing signboard including cost of material, labour, T&P etc. as per the direction of Engineer-in-charge.
Ordinary jungle clearance as per the direction of Engineer-in-charge
Wiring point for plug with 1.5 sq. mm. FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 sq. mm. concealed in the wall, complete with 14 SWG copper earth continuity wire, GP Box , piano type switch and socket etc. complete in all respect including matching colour wash. *Add for plug point with modular switch & socket in place of piano type switch & socket. *Add for Invertor Wiring in wiring Point for light/ Fan/ Plug with 1.5 mm Cu Wire as per the direction of Engineer-in-charge
Supply and fixing of power plug with 15 Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt, flush type universal modular socket switch on concealed M.S box including supply of all material, labour T&P etc. required for proper completion of work as per the direction of Engineer-in-charge
Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush type universal modular socket switch on concealed M.S box including supply of all material, labour T&P etc. required for proper completion of work as per the direction of Engineer-in-charge
Supply and Fixing of surface/flush mounting 4ways SPN distribution board with additional metal door without MCB complete in all respects as per the direction of Engineer-in-charge
Supply and Fixing of 0.5 Amp to 5 Amp. SP MCB (10KA) C Curve cat A as per the direction of Engineer-in-charge
Supply and Fixing of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve cat A as per the direction of Engineer-in-charge
Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT- AAA as per the direction of Engineer-in-charge
Supply & Wiring of Submain with two number 4 sqmm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm heavy duty PVC conduit concealed in wall with one no. 2.5 sqmm FRLSH PVC insulated multistrand copper conductor cable as earth contunity wire drawn in conduit as per the direction of Engineer-in-charge
Supply & Wiring of Submain with two number 2.5 sqmm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm heavy duty (2mm thick) PVC conduit with one no. 1.5 sqmm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth contunity wire drawn in conduit as per the direction of Engineer-in-charge
Supply and fixing and concealing of 25 mm dia. 2 mm thick PVC conduit pipe with ISI mark embossed and with PVC accessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin / adhesive to make the complete piping rigid, plastering with cement sand mortar finished to the level with matching colour wash including cost of all material labour and T&P etc required for proper completion of the work as per directions and to the satisfaction of Engineer in charge
Supply and fixing and concealing of 32 mm dia. 2 mm thick PVC conduit pipe with ISI mark embossed and with PVC accessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin / adhesive to make the complete piping rigid, plastering with cement sand mortar finished to the level with matching colour wash including cost of all material labour and T&P etc required for proper completion of the work as per directions and to the satisfaction of Engineer in charge
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required "Group C" as per the direction of Engineer-in-charge
Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12 mm thik) having 3 mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect as per the direction of Engineer-in-charge
Painting of the electric pole with 2 coats of aluminium paint over red oxide primer complete in all respect as per the direction of Engineer-in-charge
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required as per the direction of Engineer-in-charge. * 63/51 mm dia (OD 63 mm and ID 51 mm nominal)
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. as per the direction of Engineer-in-charge. * 6 sq. mm 4 core
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. as per the direction of Engineer-in-charge. * 10 sq. mm 4 core
Supply and fixing of surface/Flush mounting 6 ways VTPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge
Supply and fixing of 63 Amp. 4 Pole Isolator CAT A as per the direction of Engineer-in-charge.
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 30Watt. to 40 Watt. Confirming to IP 66 protection complete in all respect as per the direction of Engineer-in-charge. * CAT- AAA
Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 100 to 120 Watt. Confirming to IP 65 protection complete in all respect as per the direction of Engineer-in-charge. * CAT-AAA
Earthing with GI pipe 4.5 M long, 40 mm including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required as per the direction of Engineer-in-charge.
Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect as per the direction of Engineer-in-charge. * CAT-AAA
Providing and fixing PVC pipe conforming to IS make working pressure 6 Kg/Cm incuding testing labour T&P and all complete fittings (110mm dia) as per the direction of Engineer-in-charge.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipes having thermal stability for hot & cold water supply, i/c all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes and fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same i/c testing of joints complete as per direction of Engineer in charge. Concealed Work, including cutting chases and making good the wall etc. * 32 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipes having thermal stability for hot & cold water supply, i/c all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes and fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same i/c testing of joints complete as per direction of Engineer in charge. Concealed Work, including cutting chases and making good the wall etc. * 25 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipes having thermal stability for hot & cold water supply, i/c all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes and fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same i/c testing of joints complete as per direction of Engineer in charge. Concealed Work, including cutting chases and making good the wall etc. * 15 mm nominal outer dia pipes
Supply and hoisting of Sintex or equivalent high density polyethylene seamless of piece moulded tanks and placing the same in proper position including all taxes, labour and T&P etc. for proper completion of work. Tank should be ISI marked, Sintex or equivalent as per direction of Engineer in charge. (500 lt.)
Providing and fixing PTMT Ball cock of approved quality, colour and make complete with epoxy coated aluminium rod with LP/HP HD plastic ball as per direction of Engineer in charge. * 25 mm nominal bore, 152 mm long weighing not less than 440 g
Providing and fixing PTMT Ball cock of approved quality, colour and make complete with epoxy coated aluminium rod with LP/HP HD plastic ball as per direction of Engineer in charge. * 20 mm nominal bore 120 mm long weighing not less than 198 g
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white PVC flushing cistern, including flush pipe, with manually controlled device(handle lever) confirming to IS:7231, with all fitting and fixtures complete, including cutting and making good the walls and floors wherever required as per the direction of Engineer-in-charge : W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast iron P or S trap, 10 litre low level white PVC flushing cistern, including flush pipe, with manually controlled device(handle) confirming to IS:7231, with all fitting and fixtures complete, including cutting and making good the walls and floors wherever required as per the direction of Engineer-in-charge : White Vitreous china Orissa pattern W.C. pan of size 580x440 with integral type foot rests.
Providing and fixing wash basin with CI bracket, 15 mm C.P. brass pillar taps, 32 mm C.P. Brass waste of standard pattern, including painting of fittings and Bracket, cutting and making good the walls wherever required as per the direction of Engineer-in-charge : * white vitreous China wash basin size 630x450 mm with a single 15 mm CP brass pillar tap
Providing and fixing Vitreous china pedestal for wash basin i/c all cost of labour, material and T&P etc. as per the direction of Engineer-in-charge.
Providing and fixing 600x450 mm beveled edge mirror of superior glass complete with 6 mm thick hard board ground fixed to wooden cleata with CP brass screws and washers complete as per the direction of Engineer-in-charge.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing as per the direction of Engineer-in-charge. * rectangular shape 1500x450 mm
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour as per the direction of Engineer-in-charge. * 600 mm long towel rail with total length of 645 mm, width 78mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms as per the direction of Engineer-in-charge.
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gm as per the direction of Engineer-in-charge. *15 mm nominal bore
providing and fixing CP brass angle valve for basin mixer and geyser points of approved quality confirming to IS:8931 as per the direction of Engineer-in-charge. *15 mm nominal bore
providing and fixing PVC waste pipe for sink for wash basin including PVC waste fitting complete, as per the direction of Engineer-in-charge. * 32 mm dia
Providing and fixing stainless steel A ISI 304 (18/8) Kitchen Sink as per IS 13983 with CI brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required as per the direction of Engineer-in-charge. Kitchen sink without drain board. * 610 x510 mm bowl depth 200 mm
Providing and fixing stainless steel grating of approved quality and colour as per the direction of Engineer-in-charge. * 125 mm dia
Providing and fixing unplasticised PVC connection pipe with brass unions as per the direction of Engineer-in-charge. * 45 CM length : 15 mm nominal bore
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet as per the direction of Engineer-in-charge. * 150 mm diameter
Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements, weighing not less than 106 gms as per the direction of Engineer-in-charge.
Earth work in foundation in dry ordinary soil (loam clay or sand) including lift up to 1.5 meter and lead up to 30 meter and including back filling, watering and ramming of excavated earth into the trenches or into the space between the structure and the sides of foundation trenches or into the plinth with removal and disposal or surplus earth as directed by the Engineer-in-charge up to a distance of 30M from the foundation trenches : (Building) as per the direction of Engineer-in-charge.
providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13592 type A, including jointing with seal ring confirming to IS 5382, leaving 10 mm gap for thermal expansion(i) Single socketed pipes as per direction of Engineer -in-charge. * 110 mm diameter
fixing solid waste Gally trap grade "A" complete with cast iron grating, brick masonry chamber and water tight CI cover frame of 300x300 mm size (inside) square mouth Traps or P or S type traps as per direction of Engineer -in-charge. * 180x150 mm
Supplying and fixing C.I. cover without frame for manholes s per direction of Engineer -in-charge : * 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg
Providing and Engaging through contractor Beldar/Chowkidar/Waterman/Mali/Mazdoor/Lab Man/ Helper / Runner /Sweeper /Bhisti/ Bearer/ Telephone Attendant / Coolie/ Sprayer (for Bitumen,Tar etc.)/ Survey Khalasi//Stone Breaker/White Washer /Rock Breaker/Rock excavator/Rock Breaker/Rock Hole Driller/Ferry Boy/Cleaner
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design as per direction of Engineer-in-charge. * Inside dimensions (600x850x450 mm) for pipe line with three or more inlets : With common burnt clay F.P.S. (Non modular) bricks of class designation M-150
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12 mm dia steel bar conforming to IS : 1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per pecifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design as per direction of Engineer-in-charge.
Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. * All types of soil : 300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. * 100 mm nominal size dia
M/s Sanjay Traders
M/S MAHESHWARI BUILDERS
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .